01 - Outline Drawing E30D477-3
98
45 53 115 FREE SPACE
60 FOR REMOVING
75 FREE SPACE FILTER
FOR REMOVING 64.25
FILTER
WASHABLE FILTER 43.0
10 43.0
F
F
AIR INLET
47.0
AIR INLET 47.0
E E
FOR HOOD
LIFTING ONLY
09
45
52.75
AIR OUTLET BOTH ENDS
50.3
11.50
156
11.25
34.0
USABLE
18.25 06 05 06
01
06 04
08 12 16.0 4.7 101.0
14 8.00 02
03
A
30.0
55.0
2.9
5.8
A
C
C 16.2 1.750 1.25 NPT 1.25 NPT
1.746
27.00 05 8.5
26.94 13
1.75
6.014 07 60°
2
07 5.999
RATING: 1PH, 208/240 VOLTS, 2,000 WATT. 16 SOLE PLATES, QTY: 2 PROVIDED BY TIPCA, MATERIAL: ASTM A36 OR EQUIVALENT. SHEET 1 FOOT DIMENSION 51.5, 25.75 WERE 50.5 & 25.25 AND REVISED BRG
3 C. HAN 6/8/2022
RTD SCHEMATIC ON SHEET 2 By sjiang at 3:01 pm, Jun 13, 2022
04 WINDING RTD - 2 PER PHASE, 100 OHM PLATINUM TYPE, SINGLE ELEMENT. NOTES: RELOCATED BRG THERMO DIAL TO F2 SIDE; ADDED WEATERHPROOF NOTES
ON DEVICES 02 AND 03; CHANGED DWYER DIFFERENTIAL SWITCH/GAGE TO
2 A3001 MODEL, ADDED BALLOON 07 ON MCB AND DEVICES 07; ADDED C. HAN 4/21/2022 N. WEST, S. JIANG
MOTOR MODEL ON SHEET 2 TO SOLE PLATE VIEW FOR CLARITY, ADDED
A. THIS OUTLINE IS NOT TO BE REGARDED AS INDICATING THE EXACT DETAILS OF CONSTRUCTION. IT IS PROPERLY DIMENSIONED FOR ERECTION PURPOSE ONLY. BALLOON 15 AIR FILTER AND 16 SOLE PLATES
05 BEARING RTD - 1 PER BEARING, 100 OHM PLATINUM TYPE, DUAL ELEMENTS.
ISSUE DESCRIPTION ISSUED BY DATE APPROVED
B. EACH FOOT MUST BE MOUNTED ON A BASE EQUAL TO OR LARGER THAN THE PAD AREA.
06 BEARING THERMOMETER - 4.5" DIAL, ONE PER BEARING. REVISIONS
C. MOUNTING BOLTS, DOWEL SHIM PACK, JACK SCREWS & COUPLING ARE NOT SUPPLIED BY TIPCA. UNLESS SPECIFICALLY ORDERED. THESE DRAWINGS ARE PREPARED IN ACCORDANCE WITH THE NORMAL AND ACCEPTED STANDARDS WITHIN
07 2 GROUND PADS ON THE FRAME AND 2 GROUND PADS IN MAIN CONDUIT BOX BOTH INSIDE & OUTSIDE. THE ELECTRICAL INDUSTRY FOR THE PURPOSE OF OBTAINING CUSTOMER APPROVAL AS PART OF THE
D. ANTI-FRICTION BEARINGS MUST BE REGREASED WHILE MOTOR IS RUNNING. GREASE: SHELL GADUSRAIL S2, QTY REFER TO NAMEPLATE & IOM MANUFACTURING OR PRODUCTION PROCESS. ANY USE OR COMMUNICATION OF THE DRAWINGS BY THE
CUSTOMER (OTHER THAN FOR GRANTING APPROVAL) SHALL BE THE SOLE RESPONSIBILITY OF THE CUSTOMER.
08 METRIX VIBRATION SWITCH X & Y ON DE AND NDE BRACKETS ST5484E THE INFORMATION CONTAINED HEREON WHICH IS THE PROPERTY OF TOSHIBA
E. BOTH BEARINGS ARE INSULATED. SKF 6236C3 BOTH, GROUNDING BRUSH ON DE BRACKET. CERTIFIED FOR CONSTRUCTION INDUSTRIAL PRODUCTS CANADA - TIPCA MUST BE MAINTAINED IN
G.O. CONFIDENCE AND NO PORTION OF THIS DRAWING MAY BE REPRODUCED OR
USED WITHOUT THE EXPRESS PERMISSION OF THE COMPANY.
A 09 WPII HOOD WITH EXTERNAL BLOWER: 8910 ACFM, 2" SP, TEMPERATURE 70F, ELEVATION 13779 FT (4200M), 1170 RPM. AIR DENSITY: 0.0445 LB/FT^3. ___2250574___ __________
F. ROTATION: CCW VIEWED FROM NDE, BI-DIRECTIONAL CAPABILITY.
DRAWN DATE A
EXTERNAL BLOWER MOTOR: 7.5HP, 1200RPM, TEFC, 254T FOOT MOUNTED, 3/60/230/460, F1, 1.15SF, 1.25 NPT BOTTOM ENTRY, FL. AMPS. 19.7/9.9, MOTOR MODEL: CUSTOMER ORDER NUMBER C. HAN 04/04/2022
TOSHIBA: Y756SDSR41A-P CHECKED DATE TYPE HS MOTOR FRAME R1089F
G. MOTOR APPROXIMATE WEIGHT: 26,500 LBS WHICH INCLUDES WPII HOOD ESTIMATED WEIGHT: 700 LBS, EXTERNAL BLOWER SYSTEM ESTIMATED WEIGHT: 1850 LBS. __0223654_________________ N. WEST 04/07/22
CUSTOMER CHECKED DATE
10 DWYER SERIES A3000 PHOTOHELIC PRESSURE SWITCH/GAGE, MODEL: A3001 RANGE: 0-1.0" W.C.. OUTLINE- WPII BC ENCLOSURE
H. SET BEARING TEMPERATURE ALARM AT 194 F (90 C) AND SHUT DOWN VALUE TO 212 F (100 C). _KELLER ELECTRICAL
F
LOADS ON FOUNDATION F
E E
PQ PR
DEFINITIONS:
7.50
3.75
3.50
2.00 0.12 3.50
44.75
TYP 2 PLACES
89.50
C
C
B
B
SOLE PLATE
2 PIECES TYP THESE DRAWINGS ARE PREPARED IN ACCORDANCE WITH THE NORMAL AND ACCEPTED STANDARDS WITHIN
THE ELECTRICAL INDUSTRY FOR THE PURPOSE OF OBTAINING CUSTOMER APPROVAL AS PART OF THE
MANUFACTURING OR PRODUCTION PROCESS. ANY USE OR COMMUNICATION OF THE DRAWINGS BY THE
250 CUSTOMER (OTHER THAN FOR GRANTING APPROVAL) SHALL BE THE SOLE RESPONSIBILITY OF THE CUSTOMER.
THE INFORMATION CONTAINED HEREON WHICH IS THE PROPERTY OF TOSHIBA
CERTIFIED FOR CONSTRUCTION INDUSTRIAL PRODUCTS CANADA - TIPCA MUST BE MAINTAINED IN
G.O. CONFIDENCE AND NO PORTION OF THIS DRAWING MAY BE REPRODUCED OR
USED WITHOUT THE EXPRESS PERMISSION OF THE COMPANY.
A
__2250574_ _ DRAWN DATE A
CUSTOMER ORDER NUMBER C. HAN 04/04/2022
TYPE HS MOTOR FRAME R1089F
CHECKED DATE
___0223654__ _ ___ N. WEST 04/07/22
2.93 CUSTOMER CHECKED DATE
OUTLINE- WPII BC ENCLOSURE
46.75 ______KELLER ELECTRICAL
E30D477
DIMENSIONS IN INCHES