INSTRUCTION MANUAL ●● The following parts are attached to this product. Make sure to check
those before use.
Flexible Wire-saving System S-LINK V Common mode filter: 1 pc. Diode: 1 pc.
S-LINK V Control Module SL-VMC1
MJE-SLVMC1 No.0060-14V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct Ceramic capacitor (blue): 2 pcs. Surge absorber (black): 1 pc.
and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
(Note 1)
the voltage variation at the end terminal of the transmission route, since
[Control module side] 5V DC±5%
voltage drop occurs depending on the diameter or the length of the
[24V DC] 60mA or less (Note 2) transmission cable.
Current consumption
[5V DC] 200mA or less ●● If power is supplied from a commercial switching regulator, ensure that
Transmission speed A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps the frame ground (F.G.) terminal of the power supply is connected to an
Connection method “T” branch connection or multi-drop connection actual ground.
Max. 512 points (Using DIP switches, in increments / decre- ●● Do not use during the initial transient time after the power supply is
I/O points
ments of 32 points is also possible.) switched ON. Furthermore, transmission is not possible when the system is
Connectable nodes Max. 256 nodes in Busy state (during switching ON of the power supply or system setting.)
Transmission distance A mode: max. 50m, B mode: max. 200m, C mode: max. 800m ●● Make sure to use an isolation transformer for the DC power supply. If an
Total cable length A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or less auto-transformer (single winding transformer) is used, this product or the
Exclusive 4-core flat cable (0.5mm2) or power supply may get damaged.
Suitable ●● In case a surge is generated in the power supply used, connect a surge
4-core VCTF cable (non-shield) conductor cross section of
transmission cable absorber to the supply and absorb the surge.
0.3 to 2.0mm2
Address occupation: ●● Solder terminals at 260°C or less within 10 seconds.
256 bytes (including area not used) from the specified address ●● Do not run the wires together with high-voltage lines or power lines or put
Specifications for
CPU side
Address specification: them in the same raceway. This can cause malfunction due to induction.
Specified by the CS (chip selection signal) using the external logic ●● Make sure to carry out wiring in the power supply OFF condition.
Data bus width: 8 bits ●● Take care that wrong wiring will damage the product.
Interruption function When the input is changed, or when an error occurs ●● In order to reduce noise, make the wiring as short as possible.
(Note 3) [Validity (valid or invalid) of interruption can be set.] ●● In case noise generating equipment (switching regulator, inverter motor,
Ambient temperature etc.) is used in the vicinity of this product, connect the frame ground (F.G.)
0 to +55°C (No dew condensation), Storage: -20 to +70°C
(Note 4) terminal of the equipment to an actual ground.
Ambient humidity ●● This product does not have a dust-proof or water-proof construction. Do
20 to 85% RH, Storage: 20 to 85% RH
(Note 4) not use it in a place having excessive vapor, dust, etc.
Weight Approx. 20g ●● Take care that the product does not come in contact with water, chemi-
Accessory Parts kit: 1 set (refer to “ PARTS KIT.”) cals or organic solvents, such as thinner, etc. Furthermore, do not use it
Notes: 1) 24V DC and 5V DC are insulated. in an environment having corrosive gas.
2) The current consumption value is the total of the maximum current value (D-G line ●● Do not use the product in places where the ambient temperature or the
only) supplied to the S-LINK V I/O units and the current consumption value of the humidity exceeds the specifications.
S-LINK V control module.
●● Do not touch this product while operation since there are some parts
3) Validity (valid or invalid) of input interruption can be set for every point. The inter-
ruption condition (ON → OFF or OFF → ON), however, should be set in units of whose temperatures become high.
32 points. If the input change interruption signal and the error occurrence interrup-
tion signal are output at the same time, the priority will be given to the error occur-
rence interruption signal.
4) Values of control module single body are shown in these areas. To mount this
product on your device, these values may be subject to change so that the values
can be optimum for both the control module and your device.
4 TERMINAL LAYOUT DRAWING 5 INTENDED PRODUCTS FOR CE MARKING
Top view ● The models listed under “ SPECIFICATIONS” come with CE
Pin No.
Marking.
As for all other models, please contact our office.
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
● Contact for CE
<Until June 30 ,2013>
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2017