2 PARTS KIT

INSTRUCTION MANUAL ●● The following parts are attached to this product. Make sure to check
those before use.
Flexible Wire-saving System S-LINK V Common mode filter: 1 pc. Diode: 1 pc.
S-LINK V Control Module SL-VMC1
MJE-SLVMC1 No.0060-14V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct Ceramic capacitor (blue): 2 pcs. Surge absorber (black): 1 pc.
and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.

●● Never use this product in a device for personnel protection.


●● In case of using devices for personnel protection, use products which Poly switch: 2 pcs. Aluminum electrolytic capacitor:
meet laws and standards, such as OSHA, ANSI or IEC etc., for person- 1 pc.
nel protection applicable in each region or country.
●● Before touching this product, remove any electrostatic charge that may
be present on your body. There is a danger of this product getting dam-
aged due to the electrostatic charge.

●● For details of this product, refer to “Product Specifications” of the product.


For the “Product Specifications” of this product, contact our nearest 3 CAUTIONS
sales office.
●● Please refer to the "S-LINK V User's Manual" for details of the entire In case of designing a board, take care of the bottom of this product that is
S-LINK V system. the area of being prohibited from mounting parts, mounting of the parts kit,
and pattern width.
1 SPECIFICATIONS ●● This product has been developed / produced for industrial use only.
Description S-LINK V control module ●● This product is not equipped with a short-circuit protection circuit. Use a
Item Model No. SL-VMC1 power supply having a short-circuit protection function (e.g. fuse, etc.).
●● Verify that the supply voltage variation is within the rating. Also, check
Supply voltage [S-LINK V system side] 24V DC +10 -5 %

(Note 1)
the voltage variation at the end terminal of the transmission route, since
[Control module side] 5V DC±5%
voltage drop occurs depending on the diameter or the length of the
[24V DC] 60mA or less (Note 2) transmission cable.
Current consumption
[5V DC] 200mA or less ●● If power is supplied from a commercial switching regulator, ensure that
Transmission speed A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps the frame ground (F.G.) terminal of the power supply is connected to an
Connection method “T” branch connection or multi-drop connection actual ground.
Max. 512 points (Using DIP switches, in increments / decre- ●● Do not use during the initial transient time after the power supply is
I/O points
ments of 32 points is also possible.) switched ON. Furthermore, transmission is not possible when the system is
Connectable nodes Max. 256 nodes in Busy state (during switching ON of the power supply or system setting.)
Transmission distance A mode: max. 50m, B mode: max. 200m, C mode: max. 800m ●● Make sure to use an isolation transformer for the DC power supply. If an
Total cable length A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or less auto-transformer (single winding transformer) is used, this product or the
Exclusive 4-core flat cable (0.5mm2) or power supply may get damaged.
Suitable ●● In case a surge is generated in the power supply used, connect a surge
4-core VCTF cable (non-shield) conductor cross section of
transmission cable absorber to the supply and absorb the surge.
0.3 to 2.0mm2
Address occupation: ●● Solder terminals at 260°C or less within 10 seconds.
256 bytes (including area not used) from the specified address ●● Do not run the wires together with high-voltage lines or power lines or put
Specifications for
CPU side
Address specification: them in the same raceway. This can cause malfunction due to induction.
Specified by the CS (chip selection signal) using the external logic ●● Make sure to carry out wiring in the power supply OFF condition.
Data bus width: 8 bits ●● Take care that wrong wiring will damage the product.
Interruption function When the input is changed, or when an error occurs ●● In order to reduce noise, make the wiring as short as possible.
(Note 3) [Validity (valid or invalid) of interruption can be set.] ●● In case noise generating equipment (switching regulator, inverter motor,
Ambient temperature etc.) is used in the vicinity of this product, connect the frame ground (F.G.)
0 to +55°C (No dew condensation), Storage: -20 to +70°C
(Note 4) terminal of the equipment to an actual ground.
Ambient humidity ●● This product does not have a dust-proof or water-proof construction. Do
20 to 85% RH, Storage: 20 to 85% RH
(Note 4) not use it in a place having excessive vapor, dust, etc.
Weight Approx. 20g ●● Take care that the product does not come in contact with water, chemi-
Accessory Parts kit: 1 set (refer to “ PARTS KIT.”) cals or organic solvents, such as thinner, etc. Furthermore, do not use it
Notes: 1) 24V DC and 5V DC are insulated. in an environment having corrosive gas.
2) The current consumption value is the total of the maximum current value (D-G line ●● Do not use the product in places where the ambient temperature or the
only) supplied to the S-LINK V I/O units and the current consumption value of the humidity exceeds the specifications.
S-LINK V control module.
●● Do not touch this product while operation since there are some parts
3) Validity (valid or invalid) of input interruption can be set for every point. The inter-
ruption condition (ON → OFF or OFF → ON), however, should be set in units of whose temperatures become high.
32 points. If the input change interruption signal and the error occurrence interrup-
tion signal are output at the same time, the priority will be given to the error occur-
rence interruption signal.
4) Values of control module single body are shown in these areas. To mount this
product on your device, these values may be subject to change so that the values
can be optimum for both the control module and your device.
4 TERMINAL LAYOUT DRAWING 5 INTENDED PRODUCTS FOR CE MARKING
Top view ● The models listed under “ SPECIFICATIONS” come with CE
Pin No.
Marking.
As for all other models, please contact our office.
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
● Contact for CE
<Until June 30 ,2013>
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany

6 DIMENSIONS (Unit: mm)


54 11±1 3.4

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Pin No. Name Description 37


1 S-LINK V-24V Opration power for S-LINK V side
2 N.C. Not connected
3 D7
4 D6
5 D5 Electronic component
6 D4 mounting area
7 D3 Data I/O
8 D2
9 D1
10 D0
11 *RESET Reset input
12 *RD Read input
No.1 No.16
13 *WAT Wait output
2
14 *WR Write input 15 × 2.54 = 38.1
15 *CS Chip selection input
16 GND Grounding terminal for control module side
17 VDD Operation power for control module side
18 SEND Transmission indicator output
19 A0
33
20 A1
21 A2
22 A3 0.635
Address input
23 A4
24 A5
25 A6
No.32 No.17
26 A7 0.635
27 *INT S-LINK V interruption output
2.54
28 *READY S-LINK V READY output
16 × 2.54 = 40.64 4.37
29 *24V MON. S-LINK V supply voltage detection output
30 N.C. Not connected
31 S-LINK V-D D of S-LINK V side
32 S-LINK V-G G of S-LINK V side and operation power of 0V