4 TERMINAL ARRANGEMENT DIAGRAM

INSTRUCTION MANUAL Terminal No. Terminal name Cable color


1 24V Brown
Flexible Wire-saving System S-LINK V 2 0V Blue

Picking Switch for Shutter SL-VPK02 1 2 3 4 3 D White


4 G Black
CMJEC-SLVPK02 No.0079-00V
Thank you very much for purchasing Panasonic products. Read this Instruction Man- 5 CABLE CONNECTION
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference. Be sure to turn OFF the system before starting the wiring work.
● When using the dedicated cables for the
WARNING main line and branch lines of the S-LINK V T-type branching pressure-
system, use the optional dedicated pres- welding connector SL-JK1
● Never use this product as a device for protecting human bodies. (blue) (Optional)
● For protecting human bodies use a device which meets related laws / regulations sure welding connector.
and standards, such as OSHA, ANSI or IEC, in each region or country. ● Make sure that two cables with the same
● Be sure to discharge any static electricity on your body, which may damage this color are connected together when con- This
product, before handling this product. necting the main cable and the branch Main cable and product
branch cables
● This product is equipped with an arm (shutter) moving at a high speed. Limit the cables to the cables of this product. The cables with the same color
movable range so that the arm (shutter) does not contact your face or others. must be connected together.

Refer to the “S-LINK V User’s Manual” for the general information on the S-LINK V system. 6 SETTINGS
● The (optional) dedicated remote controller SL-VAR1 The opening / closing
1 APPLICABLE STANDARDS/REGULATIONS (Ver.1.01 or later) is available to configure the operat- angles of the shutter
ing settings of this product. Complete the configuration
● This product complies with the following standards / regulations. 165° 180°
with this controller before using this product.
<European Directive> Keep in mind that this product cannot be used without 135°
EMC Directive the operating settings.
<RoHS Directive> Setting items 90°
• This product is in compliance with the RoHS Directive.
• The Chinese version of RoHS indicates the contents, regardless of the RoHS regulation values. Item Description
Address offset Select the offset value.
Lamp color Select the color of the lamp. (Green, Red, or Blue)
2 PART NAMES AND FUNCTIONS Input address Select the lever input address. (0 to 255) 45°
Select the opening angle of the shutter.
Shutter opening angle 30°
Name Function (90° / 135° / 165° / 180°) 0°
2. Communication 1. Infrared commu- 15°
Infrared The transmission / reception part of signals to/ Select the closing angle of the shutter.
indicator nication part Shutter closing angle
1 communication from the dedicated configuration remote control- (0° / 15° / 30° / 45°)
part ler SL-VAR1 (Optional) Select the time at which the shutter starts to close.
Shutter closing delay
(0 / 1 / 4 / 7 / 10 seconds)
Communication Illuminates when the power is ON.
2
3. Lamp indicator Blinks with synchronizing signals from the controller. Notes: 1) For the settings, refer to the “SL-VAR1 Instruction Manual.
You can select the LED color (Red, Green, or Blue). 2) Actual opening/closing angles may differ from the configured settings due to the shutter shape, weight, wind
Otherwise 2 step display mode can be selected. and other installation conditions. Be sure to check the operating settings in actual usage conditions.
3 Lamp
* For more information on 2 step display mode,
4. 4-pin type pres-
4-pin type
refer to the "SL-VPK02 specification."
The SL-CP2 connector is included to connect to
7 Error indication by the lamp
sure-welding fe-
male connector pressure- the main cable and branch cables of the S-LINK V.
4
welding female For the terminal arrangement, refer to " 4
● The shutter stops when it is blocked by any obstacle.
6. Movable arm connector TERMINAL ARRANGEMENT DIAGRAM." ● The blinking lamp color depends on the lamp color / mode selection.
5. Lever switch
5 Lever switch Operating the lever switch turns the input ON. <For opening the shutter>
6 Movable arm The shutter is attached to it. • When the Green lamp color or 2-stage indication mode is set: Blinks in red and green alternately.
• When the Red or Blue lamp color is set: Blinks in red and blue alternately.
3 MOUNTING <For closing the shutter>
• Blinks in red
Mounting to the pipe (ø28)
1. Remove the holder-fixing socket head hex bolt [M6(length: 15 mm)], 8 SPECIFICATIONS
and the pipe mounting holder simultaneously.
Designation Picking switch for shutter
2. Align the respective connecting parts of this product and the pipe mounting holder Model name SL-VPK02
so that the pipe is sandwiched between them. Power supply voltage 24V DC ±10% (Supplied from a S-LINK V control unit. A separate power supply is also available.)
3. Insert the socket head hex bolt from the main body side into the mounting hole on Current consumption 24V DC line 25mA or less (when the lamp is ON), Current for shutter operation: 450mA or less
the pipe mounting holder to secure them. Communication specification Complies with S-LINK V protocol.
Communication mode B mode, C mode
1. Hook the tab into the slot. Input address (lever switch): 0 to 255
Address settings
Output address (lamp, shutter): Select an offset of +32, +64, +128, or +256 from the input address.
2. Align the respective connecting parts. Tilting the lever switch at an angle between 15° and 30° turns the input ON.
Input operation
Pipe mounting holder Pulling the lever switch approx. 2mm or more turns the input ON. (Note).
This product Number of I/Os 1 lever input, 1 lamp or shutter output
Protection structure IP40 (IEC) equivalent
Ambient temperature 0 to +50°C (No dew condensation), Storage: -20 to +60°C
3. Tighten the bolt. Ambient humidity 35 to 85%RH, Storage: 35 to 85%RH
Pipe Front cover: Polycarbonate, Lamp cover: Polycarbonate
Material Rear case: ABS, Pipe mounting holder: SPCC
Driving shaft: SUM, Arm: SPCC
Holder-fixing socket head hex bolt
Cable 4-core cabtire cable 0.15m (With SL-CP2 pressure welding type male connector)
[M6(length: 15mm)]
Weight (Main body only) Approx. 250g
ø28 Pipe mounting holder: 1 pc., Arm plate: 1 pc.
Accessories Plate-fixing screws [M4(length: 12mm)]: 2 pcs., Plate-fixing spring washer: 2 pcs.
Attaching the shutter Holder-fixing socket head hex bolt [M6 (length: 15mm)]: 1 pc.
● Attach the shutter to the movable arm Note: Pulling load is 19.6N or less. Make sure that stress by forcible bend or pulling is not applied directly to the lever part.
This product
on this product.
● Use the accessory arm plate, plate- Arm plate (Accessory)
9 CAUTIONS
fixing screws [M4 truss head screws
(length: 12mm)], and plate-fixing ● This product has been developed / produced for industrial use only.
spring washers to attach the shutter. ● Make sure to use an isolation transformer for the DC power supply. If an auto-
Movable arm transformer (single winding transformer) is used, this product or the power supply
may get damaged.

Plate-fixing screw
[M4 truss head screw (length: 12mm)] (Accessory)
Shutter

Plate-fixing spring washer (Accessory)

<Reference dimension of the shutter (Unit: mm)>


10

2-ø6
<Recommended shutter>
40±1

210

• Material: Corrugated plastic


• Max. thickness: 5mm Panasonic Industrial Devices SUNX Co., Ltd.
• Max. weight: Approx. 50g
https://panasonic.net/id/pidsx/global
*: The size and weight of the shutters available depend on the
several factors such as the shape, material, and opening / Please visit our website for inquiries and about our sales network.
300 closing angle of the shutter. Panasonic Industrial Devices SUNX Co., Ltd. 2022
Be sure to check the shutter operation by attaching to the ac-
(Thickness: 5, Density of corrugated plastic sheet: 800g/m2) tual system. April, 2022 PRINTED IN JAPAN

You might also like