Exam UTDOMZONWP
Exam UTDOMZONWP
B. 53520 AT/pole
C. 54235 AT/pole
D. 54703 AT/pole
1. A DC shunt generator delivers 360 A at 250 V. The ar- motor is 70 Nm. Neglecting the rotational losses of the
mature and shunt winding resistances are 0.03 Ω and machine, the current drawn by the motor from 230 V
A. 260.800 V A. 29.73 A
B. 239.075 V B. 33.93 A
C. 263.534 V C. 27.25 A
D. 260.925 V D. 29.00 A
2. A 4 pole DC generator, having wave wound armature 5. A short shunt compound generator delivers a current
winding has 30 slots, and 20 conductors per slot. Flux of 440 A at 230 V. The armature, series and shunt field
per pole is 28 mWb. What is the emf generated when resistances are 0.04 Ω, 0.045 Ω and 50 Ω respectively.
motor is driven at 370 rpm. Determine the EMF generated. Allow a brush contact
drop of 1 V per brush.
A. 207.200 V
A. 267.400 V
B. 202.200 V
B. 250.728 V
C. 188.552 V
C. 192.175 V
D. 214.700 V
D. 269.600 V
3. A 31.7 kW, 480 V, 4 pole wave wound DC shunt mo-
tor has 820 armature conductors and 120 commutator 6. A 210 V DC shunt motor takes 2 A at no load. It
segments. Its full load efficiency is 97.0 % and the draws 24 A when running at full load at 1490 rpm.
shunt field current is 1.5 A. If the brushes are shifted The armature and shunt resistance are 0.52 Ω and 220
backward 1.6 segment from geometrically neutral axis. Ω, respectively. The no load speed in rpm is
A. 0.381 A A. 12.88 Nm
B. 0.328 A B. 15.16 Nm
C. 11.06 Nm
C. 0.755 A
D. 13.94 Nm
D. 0.376 A
12. A 500 V DC shunt motor draws a line current of 6 A,
8. A break test is conducted on a DC motor. The spring
on no load. If armature resistanc is 0.3 Ω and field
balance reading are 5 kg and 32 kg. The diameter of
resistance is 230 Ω, determine the efficiency of the ma-
drum is 44 cm. The speed of the motor under these
chine running as a generator delivering a load current
loading is 910 rpm, when supplied at 220 V, taking
of 35 A at 500 V.
current of 30 A from the mains. Find efficiency.
A. 84.987 %
A. 80.951 %
B. 85.187 %
B. 76.961 %
C. 65.000 %
C. 84.111 %
D. 81.000 %
D. 83.031 %
13. A separately excited generator when running at 970
9. A DC generator has armature induced emf of 220 V rpm supplieS 50 A to a resistive load at 240 V. What
when flux per pole is 14 mWb, and speed is 530 rpm. will be the load current when the speed drops to 420
Calculate the emf generated when speed is 1180 rpm rpm, if field current is unchanged. Given armature re-
but flux per pole is 20 mWb. sistance is 0.8 Ω.
A. 692.733 V A. 25.149 A
B. 692.630 V B. 21.649 A
C. 699.730 V C. 23.849 A
D. 709.811 V D. 20.249 A
Page 2
C. 4.646 W A. 1490.000 rpm
D. 11.966 W B. 1850.000 rpm
15. A 4 pole wave wound motor armature has 660 conduc- C. 1480.800 rpm
tors and delivers 115 A. The brushes have been dis-
D. 1390.000 rpm
placed through 1.8 angular degrees from geometrical
axis. Calculate Demagnetising ampere turns per pole. 19. A 8 pole DC generator has induced emf of 210 V
A. 224 AT/Pole when driven at a speed of 260 rpm.The armature is
B. 196 AT/Pole lap wound and has 10 conductors. The armature re-
Page 3