Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Building Act 1993

Section 238(1)(a)
Building Regulations 2018
Regulation 126

CERTIFICATE OF COMPLIANCE FOR PROPOSED BUILDING WORK


JOB NUMBER: 2215220
This certificate is issued to Relevant Building Surveyor
postal address

This certificate is issued in relation to the proposed building work at:

LOT 1148, HEGGART CRESCENT, OFFICER SOUTH.


Nature of proposed building work Building classification
Construction of PROPOSED RESIDENCE - CLASSES 1A AND 10A Dwelling Class 1A
Double Storey Garage Class 10A
Brick veneer construction
Version of BCA applicable to certificate Vol 2 2019

Prescribed class of building work for which this certificate is issued:


Design or part of the design of building work relating to Structural matter and Drainage matter.

Documents setting out the design that is certified by this certificate

Type of document (e.g., drawings, Number of


Document no. Document date Prepared by
computations, specifications, calculations etc.) pages
Click Engineering
2215220/1 09 November 2021 Drawings 15
(Aust) Pty Ltd
Click Engineering
2215220 01 October 2021 Computations 17
(Aust) Pty Ltd
Reference/Other documentation sighted but not certified by this certificate
Click Engineering
2214650 28 August 2021 Soil Report -
(Aust) Pty Ltd

The design certified by this certificate complies with the following provisions of Building Act 1993, Building
Regulations 2018 or National Construction Code
Act, Regulation or NCC Section, Regulation, Part, Performance Requirement or other provision
National Construction Code Series Volume One and Two (inc. Part 3.2) - Building Code of Australia, 2019
Building Regulations 2018
Part 7 of the Building Act Section 238(1)(b).
AS1170.1-2002 Structural Design Actions (Inc Amendment 1 and 2), AS1170.2-2011
Structural Design Actions (Inc Amendment 1 and 2), AS4100-1998 Steel Structures Code,
Relevant Australian Standards AS1684-2010 Timber Framing Code, AS1720.1-2010 Timber Structures Code Part 1,
AS2870-2011 Residential Slab and Footing Code, AS3600-2018 Concrete Structures Code,
AS3700-2018 Masonry Code, AS3500.3-2018 Plumbing and Drainage Code

I prepared the design, or part of the design, set out in the documents listed above.
I certify that the design set out in the documents listed above complies with the provisions set out above.
I believe that I hold the required skills, experience and knowledge to issue this certificate and can demonstrate this if requested
to do so.

Enio Sciessere
Click Engineering (Aust) Pty Ltd
Address: Level 1, 25-27 Railway Road, Blackburn, 3130
Email: contact@clickeng.com.au
Endorsed Building Engineer and area of Engineering
CERTIFICATE prepared for
Civil Engineer
Endorsed Building Engineer Registration No. PE0000984 BCTA Homes EAST
Date of issue of certificate: 09 November 2021
Melbourne

CLICK ENGINEERING (AUST) PTY LTD level 1, 25-27 railway road, blackburn vic 3130 P 03 9894 4422 E contact@clickeng.com.au ACN 162 735 917
STRUCTURAL COMPUTATIONS
1 October 2021

PROPOSED RESIDENCE - CLASSES 1A AND 10A


LOT 1148, HEGGART CRESCENT, OFFICER SOUTH.

JOB NUMBER: 2215220 PAGE 1 OF 17 PAGES

Being duly qualified Civil Engineers, we hereby certify that the computations and drawings denoted with Our Reference Number,
as shown above, have been prepared by one of us, or under our direct supervision, and comply with the relevant Regulations
under the National Construction Code Series Volumes One and Two - Building Code of Australia, 2019, and the following
Australian Standard Codes:

1 AS 1170.1 2002 Structural Design Actions (Inc Amd 1 and 2)

2 AS 1170.2 2011 Structural Design Actions (Inc Amd 1 and 2)

3 AS 4100 1998 Steel Structures Code

4 AS 1684 2010 Timber Framing Code

5 AS 1720 2011 Timber Structures Code Part 1

6 AS 1726 Site Investigation Code

7 AS 2870 2011 Residential Slab and Footing Code

8 AS 3600 2018 Concrete Structures Code

9 AS 3700 2018 Masonry Code

10 AS 3500.3 2018 Plumbing and Drainage P3. Stormwater Drainage

For and on behalf of

STRUCTURAL COMPUTATIONS prepared for

BCTA Homes EAST Melbourne


LOT 1148, HEGGART CRESCENT, OFFICER SOUTH.

CLICK ENGINEERING (AUST) PTY LTD level 1, 25-27 railway road, blackburn vic 3130 P 03 9894 4422 E contact@clickeng.com.au ACN 162 735 917
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 2
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

Member: RB1 3.60 m Lateral restraint (Lay) = 1.00 m


P2 (kN)
b P1 (kN)
w1 (kN/m) w2 (kN/m)
a= 0m
x-x b= 0m
d RA a b c RB c= 3.6 m
y-y

Uniform Distributed Loads: UDL, W1 UDL, W2


Dead Loads - Start 0.00 m End 3.60 m Start 3.60 m End 3.60 m
Roofing - 0.90 kPa 1.00 m = 0.90 kN/m 0.00 m = 0.00 kN/m
Stud Wall - 0.50 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Timber Floor - 0.70 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Balcony Floor - 2.00 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
SWT - 0.10 kPa 0.10 kN/m 0.10 kN/m
Q1 = 0.5 kPa 0.00 m 0 kN/m 0.00 m 0 kN/m
Total DL = 1.00 kN/m Total DL = 0.10 kN/m
Live Loads -
Roof - 0.62 kPa 1.00 m = 0.62 kN/m 0.00 m = 0.00 kN/m
Floor 1 - 1.50 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Floor 2 - 2.00 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Total LL = 0.62 kN/m Total LL = 0.00 kN/m
DL + LL = 1.62 kN/m DL + LL = 0.10 kN/m

Point Loading: Point Load, P1 Point Load, P2


Dead Load - 0.00 kN Dead Load - 0.00 kN
Live Load - 0.00 kN Live Load - 0.00 kN
DL + LL = 0.0 kN DL + LL = 0.0 kN

Reactions
Working Ultimate Working Ultimate
Ra DL = 1.80 kN 2.25 kN Rb DL = 1.80 kN 2.25 kN
Ra LL = 1.12 kN 1.67 kN Rb LL = 1.12 kN 1.67 kN
Ra TL = 2.92 kN 3.92 kN Rb TL = 2.92 kN 3.92 kN

Timber Beam Design:

Strength limit states Factors Section Properties


Permanent Term phi = 0.80 k1 = 0.57
M* = 2.03 kNm @ 1.80 m k4 = 1.00 Exx = 13200
phiM = 9.53 kNm ...O.K. k6 = 1.00 Ixx = 101.25
k9 = 1.00 Zxx = 675
Short Term phi = 0.8 k1 = 0.8 k11 = 1.00 j2 = 2
M* = 3.45 kNm @ 1.80 m k12 = 0.74 f'b = 41.885
phiM = 13.38 kNm ...O.K. k7 = 1.00 f's = 4.6
f'p = 12

Deflection
Defl. (long-term) = 3.27 mm @ 1.80 m Allowable 12 mm ...O.K.
Defl. (live load) = 1.01 mm @ 1.80 m Allowable 9 mm ...O.K.

Shear (2/3)As = 9000 mm2 Bearing Ab = 4050 mm2 Bearing length = 90 mm


Dead Load Only phi = 0.80 k1 = 0.57 Dead Load Only phi = 0.80 k1 = 0.57
V* = 2.25 kNm N* = 2.25 kNm
phiV = 18.88 kNm ...O.K. phiN = 22.16 kNm ...O.K.

Dead + Live Load phi = 0.8 k1 = 0.8 Dead + Live Load phi = 0.8 k1 = 0.8
V* = 3.92 kNm N* = 3.92 kNm
phiV = 26.50 kNm ...O.K. phiN = 31.10 kNm ...O.K.

Adopt: 300 x 45 HYSPAN LVL


Date:01/10/2021
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 3
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

Member: RB2 3.10 m Lateral restraint (Lay) = 1.00 m


P2 (kN)
b P1 (kN)
w1 (kN/m) w2 (kN/m)
a= 1.2 m
x-x b= 0m
d RA a b c RB c= 1.9 m
y-y

Uniform Distributed Loads: UDL, W1 UDL, W2


Dead Loads - Start 0.00 m End 1.20 m Start 1.20 m End 3.10 m
Roofing - 0.90 kPa 1.00 m = 0.90 kN/m 2.20 m = 1.98 kN/m
Stud Wall - 0.50 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Timber Floor - 0.70 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Balcony Floor - 2.00 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
SWT - 0.10 kPa 0.10 kN/m 0.10 kN/m
Q1 = 0.5 kPa 0.00 m 0 kN/m 0.00 m 0 kN/m
Total DL = 1.00 kN/m Total DL = 2.08 kN/m
Live Loads -
Roof - 0.30 kPa 1.00 m = 0.30 kN/m 2.20 m = 0.66 kN/m
Floor 1 - 1.50 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Floor 2 - 2.00 kPa 0.00 m = 0.00 kN/m 0.00 m = 0.00 kN/m
Total LL = 0.30 kN/m Total LL = 0.66 kN/m
DL + LL = 1.30 kN/m DL + LL = 2.74 kN/m

Point Loading: Point Load, P1 Point Load, P2


Dead Load - 1.71 kN Dead Load - 0.00 kN
Live Load - 0.48 kN Live Load - 0.00 kN
DL + LL = 2.2 kN DL + LL = 0.0 kN
TGT

Reactions
Working Ultimate Working Ultimate
Ra DL = 3.23 kN 4.03 kN Rb DL = 3.64 kN 4.54 kN
Ra LL = 0.97 kN 1.46 kN Rb LL = 1.13 kN 1.69 kN
Ra TL = 4.20 kN 5.49 kN Rb TL = 4.76 kN 6.24 kN

Timber Beam Design:

Strength limit states Factors Section Properties


Permanent Term phi = 0.80 k1 = 0.57
M* = 3.95 kNm @ 1.24 m k4 = 1.00 Exx = 13200
phiM = 9.53 kNm ...O.K. k6 = 1.00 Ixx = 101.25
k9 = 1.00 Zxx = 675
Short Term phi = 0.8 k1 = 0.8 k11 = 1.00 j2 = 2
M* = 5.36 kNm @ 1.24 m k12 = 0.74 f'b = 41.885
phiM = 13.38 kNm ...O.K. k7 = 1.00 f's = 4.6
f'p = 12

Deflection
Defl. (long-term) = 4.59 mm @ 1.55 m Allowable 10.33 mm ...O.K.
Defl. (live load) = 0.70 mm @ 1.55 m Allowable 8.611 mm ...O.K.

Shear (2/3)As = 9000 mm2 Bearing Ab = 4050 mm2 Bearing length = 90 mm


Dead Load Only phi = 0.80 k1 = 0.57 Dead Load Only phi = 0.80 k1 = 0.57
V* = 4.54 kNm N* = 4.54 kNm
phiV = 18.88 kNm ...O.K. phiN = 22.16 kNm ...O.K.

Dead + Live Load phi = 0.8 k1 = 0.8 Dead + Live Load phi = 0.8 k1 = 0.8
V* = 6.24 kNm N* = 6.24 kNm
phiV = 26.50 kNm ...O.K. phiN = 31.10 kNm ...O.K.

Adopt: 300 x 45 HYSPAN LVL


Date:01/10/2021
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 4
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

BEAM: B1 SPAN = 5.30 m


Le = 1.00 m EFFECTIVE LENGTH

LOADINGS: (U.D.L.)

ROOF DL = 0.00 m x 0.90 kPa = 0.00 kN/m


ROOF LL = 0.00 m x 0.25 kPa = 0.00 kN/m
FLOOR DL = 4.00 m x 1.00 kPa = 4.00 kN/m
FLOOR LL = 4.00 m x 1.50 kPa = 6.00 kN/m
WALL DL = 2.50 m x 0.50 kPa = 1.25 kN/m
BEAM SW = = 0.37 kN/m

Dead load (G) = 5.62 kN/m


Live load (Q) = 6.00 kN/m

TOTAL LOAD = 11.62 kN/m

LOADINGS: (POINT LOAD)

Location of Point load 1 = 0.00 m Location of Point load 2 = 0.00 m


P (G) = 0.00 kN P (G) = 0.00 kN
P (Q) = 0.00 kN P (Q) = 0.00 kN
P (TL) = 0.00 kN P (TL) = 0.00 kN

DESIGN
P 1 kN P 2 kN
W - ULTIMATE = 16.03 kN/m W kN/m
P 1 - ULTIMATE = 0.00 kN mmmmmmmmmmmmmmm
P 2 - ULTIMATE = 0.00 kN Ra Rb

Mu = 56.3 kNm Ra(U) = 42.48 Rb(U) = 42.48


Ra(W) = 30.80 Rb(W) = 30.80
TRY 250 UB 37 Ra(DL) = 14.90 Rb(DL) = 14.90

phi Ms = 140.0 kNm Mmax @ x = 2.65 m

alpha m = 1.00

alpha s = 0.98
SECTION PROPERTIES

phi Mb = 136.6 kNm ..OK Ix = 55.7 E6 mm4


Iy = 5.66 E6 mm4
Zex = 486 E3 mm3
DEFLECTION J = 158 E3 mm4
Iw = 85.2 E9 mm9
l/300 = 17.67 mm Fy = 320 MPa

DL + 0.7LL = 9.06 mm ..OK


DL + LL = 10.72 mm

ADOPT 250 UB 37
Date:01/10/2021
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 5
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

LINTEL GL1 SPAN = 4800 mm

LOADING

BRICKWORK 0.40 m x 2.10 KPa = 0.84 KN/m


LINTEL SW 0.30 KN/m

1.14 KN/m

FABRICATED ANGLE LINTEL

TRY 100 x 10 MS PLATE HORIZONTAL


200 x 10 MS PLATE VERTICAL

SECTION PROPERTIES

Ixx = 12.69 E6 mm^4


Iyy = 2.87 E6 mm^4
Zxx = 96.39 E3 mm^3
ry = 30.91 mm
D/T = 20.00

DESIGN CHECK STRESS

LOAD W= 1.14 KN/m L = 4800 mm


MOMENT M= 3.28 KNm L/ry = 155.28
L/500 I= 4.10 E6 mm^4 B = 109.91 MPa
A = 220.19 MPa
12.69 > 4.10 ..OK FOB = 212.51 MPa
Fy = 250.00 MPa
L/500 = 9.60 mm
=> FOB < FY
Defl (TL) = 3.10 mm ..OK
fb = 34.06 MPa

FB = 98.82 MPa ..OK

ADOPT 100 x 10 MS PLATE HORIZONTAL


200 x 10 MS PLATE VERTICAL
@ 6mm CFW 150 LONG 50% HIT MISS
ALTERNATE BOTH SIDES

Adopt 200 x 110 x 10 EXTERNAL ANGLE Date:01/10/2021


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 6
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

COLUMN C1 H= 2800 mm MAX

TOTAL LOAD = 31 kN B1

TRY 89 x 89 x 5.0 EC LOAD = 100 mm

MOM = 3.1 kNm AREA = 1590 mm^2

f ac = 19.4968553 MPa Z = 40.7 E3mm^3

fbc = 76.1670762 MPa r = 33.7 mm

l/r = 70.6231454
Fac = 149.552411 MPa
Foc = 395.7634 MPa

Fbc = 231 MPa

=> f ac/Fac+ f bc/Fbc= 0.46009565

=> f ac/Fac + Cmx f bc


= 0.48959012

(1- f ac/0.6Foc)Fbc

ADOPT 89 x 89 x 5.0 SHS Date:01/10/2021


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 7
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

TIMBER POST CHECK

P1
LOADING ULTIMATE
F Nc = F k1 x k4 x k6 x k11 x k12 [f'c Ac] DL = 6.79 kN
LL = 3.36 kN
b d TL = 10.15 kN
F = 0.8 Post Size 90 x 90 RB1&RB2
k1 = 0.57 DL ONLY
k1 = 0.8 DL + LL
k4 = 1
k6 = 1 g13 = 0.85 rc = 0.98
k11 = 1 L = 3.1 m
k12 = 0.24 Lax = 3.1 m S3 (1) = 34.444 S4 (1) = 34.444444
f'c = 15 Lay = 3.1 m S3 (2) = 29.278 S4 (2) = 29.277778
Ac = 8100
S3 = 29.278 S4 = 29.277778

F Nc (DL ONLY) = 13 kN OK... S = 29.28


F Nc (DL+LL) = 19 kN OK... rcS = 28.69

Adopt 90 x 90 F7 rcS<10 = 1 FALSE


KD Pine Post 10<rcS<20 = 0.065 FALSE
rcS>20 = 0.243 0.242941
k12 = 0.242941
Date:01/10/2021
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 8
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

SUSPENDED REINFORCED CONCRETE BEAM External - Family

MAX CLEAR SPAN = 1800 mm

LOADING:

WALL "DL" 5.5 m x 2.50 kPa = 13.75 kN/m


ROOF "DL" 5.1 m x 0.90 kPa = 4.59 kN/m
ROOF "LL" 5.1 m x 0.25 kPa = 1.28 kN/m
FLOOR"DL" 2.2 m x 1.00 kPa = 2.20 kN/m
FLOOR"LL" 2.2 m x 1.50 kPa = 3.30 kN/m
SLAB"DL" 1.2 m x 3.20 kPa = 3.84 kN/m
SLAB"LL" 1.2 m x 1.50 kPa = 1.80 kN/m
BEAM "SW" = 2.98 kN/m

33.73 kN/m

=> g= 27.36 kN/m q= 6.38 kN/m

Wu = 43.76 kN/m

M-ve = 0.110 x Wu x L^2 = 15.60 KNm


M+ve = 0.091 x Wu x L^2 = 12.90 KNm

TRY D= 0.31 m X B= 0.40 m RC BEAM

=> Ast -ve = 160 mm^2 MESH "OR" 201 mm^2 BARS
Ast +ve = 143 mm^2 MESH "OR" 179 mm^2 BARS

TRY 1 R11TM(4) TOP => Ast = 356 mm^2

AND 1 R11TM(4) BOTTOM => Ast = 356 mm^2

CHECK MINIMUM STRENGTH REQUIREMENTS

CONCRETE F'c = 20 MPa


DEPTH D = 310 mm => do = 255 mm
WIDTH bw = 400 mm
fsy = 500 MPa
Asc = 356 mm^2 TOP REINFORCEMENT
Ast = 356 mm^2 BOTTOM REINFORCEMENT

Gross Inertia I= 993.03 E6 mm^4

Mcr = 17.19 KNm Mu = 42.96 KNm M +ve => OK


1.2Mcr = 20.63 KNm Mu = 42.96 KNm M -ve => OK

CHECK SERVICEABILITY

k1 = 0.045 k2 = 0.0054 D/LeF = 0.002


g= 27.36 q= 6.38
Us = 0.7 Ul = 0.4 kcs = 0.8 ...OK

=> Fdef = 55.74

Lef/d = 13.92
l/d = 7.20 ...OK
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 9
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

CHECK SHEAR "CONSIDER CONTINUITY OF 3 OR MORE SPANS"

Vu = d" AWAY
35.46 FROM
kN CRITICAL SUPPORT

B1 = 1.47 D= 310 mm do = 260 mm


B2 = 1.00 B= 400 mm
B3 = 1.00

F'c = 20 MPa CONCRETE STRENGTH


Ast = 356 mm^2

Vuc = 62.7 kN & 0.7*Vuc = 43.9 kN

=> 43.9 > 35.46 ...ok no shear reo required

ADOPT 310 X B= 400 RC BEAM

WITH 1 R11TM(4) TOP & 1 R11TM(4) BOTTOM

MAX CLEAR SPAN = 1800 mm

F'c = 20 MPa CONCRETE


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 10
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

SUSPENDED REINFORCED CONCRETE BEAM Stepdown - Garage

MAX CLEAR SPAN = 1800 mm

LOADING:

WALL "DL" 5.6 m x 0.50 kPa = 2.80 kN/m


ROOF "DL" 6.7 m x 0.90 kPa = 6.03 kN/m
ROOF "LL" 6.7 m x 0.25 kPa = 1.68 kN/m
FLOOR"DL" 1.2 m x 1.00 kPa = 1.20 kN/m
FLOOR"LL" 1.2 m x 1.50 kPa = 1.80 kN/m
SLAB"DL" 2.4 m x 3.00 kPa = 7.20 kN/m
SLAB"LL" 2.4 m x 3.00 kPa = 7.20 kN/m
BEAM "SW" = 2.98 kN/m

30.88 kN/m

=> g= 20.21 kN/m q= 10.68 kN/m

Wu = 41.27 kN/m

M-ve = 0.110 x Wu x L^2 = 14.71 KNm


M+ve = 0.091 x Wu x L^2 = 12.17 KNm

TRY D= 0.31 m X B= 0.40 m RC BEAM

=> Ast -ve = 151 mm^2 MESH "OR" 189 mm^2 BARS
Ast +ve = 135 mm^2 MESH "OR" 169 mm^2 BARS

TRY 1 R11TM(4) TOP => Ast = 356 mm^2

AND 1 R11TM(4) BOTTOM => Ast = 356 mm^2

CHECK MINIMUM STRENGTH REQUIREMENTS

CONCRETE F'c = 20 MPa


DEPTH D = 310 mm => do = 255 mm
WIDTH bw = 400 mm
fsy = 500 MPa
Asc = 356 mm^2 TOP REINFORCEMENT
Ast = 356 mm^2 BOTTOM REINFORCEMENT

Gross Inertia I= 993.03 E6 mm^4

Mcr = 17.19 KNm Mu = 42.96 KNm M +ve => OK


1.2Mcr = 20.63 KNm Mu = 42.96 KNm M -ve => OK

CHECK SERVICEABILITY

k1 = 0.045 k2 = 0.0054 D/LeF = 0.002


g= 20.21 q= 10.68
Us = 0.7 Ul = 0.4 kcs = 0.8 ...OK

=> Fdef = 47.26

Lef/d = 14.71
l/d = 7.20 ...OK
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 11
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

CHECK SHEAR "CONSIDER CONTINUITY OF 3 OR MORE SPANS"

Vu = d" AWAY
33.44 FROM
kN CRITICAL SUPPORT

B1 = 1.47 D= 310 mm do = 260 mm


B2 = 1.00 B= 400 mm
B3 = 1.00

F'c = 20 MPa CONCRETE STRENGTH


Ast = 356 mm^2

Vuc = 62.7 kN & 0.7*Vuc = 43.9 kN

=> 43.9 > 33.44 ...ok no shear reo required

ADOPT 310 X B= 400 RC BEAM

WITH 1 R11TM(4) TOP & 1 R11TM(4) BOTTOM

MAX CLEAR SPAN = 1800 mm

F'c = 20 MPa CONCRETE


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 12
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

SUSPENDED REINFORCED CONCRETE BEAM LBW - Guest Ensuite

MAX CLEAR SPAN = 1800 mm

LOADING:

WALL "DL" 5.5 m x 0.50 kPa = 2.75 kN/m


ROOF "DL" 0.0 m x 0.90 kPa = 0.00 kN/m
ROOF "LL" 0.0 m x 0.25 kPa = 0.00 kN/m
FLOOR"DL" 4.0 m x 1.00 kPa = 4.00 kN/m
FLOOR"LL" 4.0 m x 1.50 kPa = 6.00 kN/m
SLAB"DL" 1.8 m x 3.00 kPa = 5.40 kN/m
SLAB"LL" 1.8 m x 3.00 kPa = 5.40 kN/m
BEAM "SW" = 2.98 kN/m

26.53 kN/m

=> g= 15.13 kN/m q= 11.40 kN/m

Wu = 36.01 kN/m

M-ve = 0.110 x Wu x L^2 = 12.83 KNm


M+ve = 0.091 x Wu x L^2 = 10.62 KNm

TRY D= 0.31 m X B= 0.40 m RC BEAM

=> Ast -ve = 132 mm^2 MESH "OR" 165 mm^2 BARS
Ast +ve = 118 mm^2 MESH "OR" 147 mm^2 BARS

TRY 1 R11TM(4) TOP => Ast = 356 mm^2

AND 1 R11TM(4) BOTTOM => Ast = 356 mm^2

CHECK MINIMUM STRENGTH REQUIREMENTS

CONCRETE F'c = 20 MPa


DEPTH D = 310 mm => do = 255 mm
WIDTH bw = 400 mm
fsy = 500 MPa
Asc = 356 mm^2 TOP REINFORCEMENT
Ast = 356 mm^2 BOTTOM REINFORCEMENT

Gross Inertia I= 993.03 E6 mm^4

Mcr = 17.19 KNm Mu = 42.96 KNm M +ve => OK


1.2Mcr = 20.63 KNm Mu = 42.96 KNm M -ve => OK

CHECK SERVICEABILITY

k1 = 0.045 k2 = 0.0054 D/LeF = 0.002


g= 15.13 q= 11.40
Us = 0.7 Ul = 0.4 kcs = 0.8 ...OK

=> Fdef = 38.85

Lef/d = 15.70
l/d = 7.20 ...OK
CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 13
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

CHECK SHEAR "CONSIDER CONTINUITY OF 3 OR MORE SPANS"

Vu = d" AWAY
29.18 FROM
kN CRITICAL SUPPORT

B1 = 1.47 D= 310 mm do = 260 mm


B2 = 1.00 B= 400 mm
B3 = 1.00

F'c = 20 MPa CONCRETE STRENGTH


Ast = 356 mm^2

Vuc = 62.7 kN & 0.7*Vuc = 43.9 kN

=> 43.9 > 29.18 ...ok no shear reo required

ADOPT 310 X B= 400 RC BEAM

WITH 1 R11TM(4) TOP & 1 R11TM(4) BOTTOM

MAX CLEAR SPAN = 1800 mm

F'c = 20 MPa CONCRETE


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 14
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

Screw Pile Capacity External - Family Double

Loads = UDL
m m
DL Roof = 5.1 x 1.8 x 0.9 kPa = 8.3 kN
Wall = 5.6 x 1.8 x 2.5 kPa = 25.2 kN
Floor = 2.2 x 1.8 x 1 kPa = 4.0 kN
Slab = 1.2 x 1.8 x 3.2 kPa = 6.9 kN
E beam = 0.31 x 1.8 x 0.3 x 25 = 4.2 kN

DL = 48.5 kN

LL Roof = 5.1 x 1.8 x 0.25 kPa = 2.3 kN


Floor = 2.2 x 1.8 x 1.5 kPa = 5.9 kN
Slab = 1.2 x 1.8 x 1.5 kPa = 3.2 kN

LL = 11.5 kN

TL = 60.0 kN

DL + LL = 66.0 kN

Screw Piles Driven to a Safe Working Load of 80 kN

Screw Pile Capacity Internal -Kithchen/Dining

Loads = UDL
m m
DL Roof = 0 x 0 x 0.9 kPa = 0.0 kN
Wall = 5.6 x 3.6 x 0.35 kPa = 7.1 kN
Floor = 0 x 0 x 1 kPa = 0.0 kN
Slab = 3 x 3.6 x 3.2 kPa = 34.6 kN
E beam = 0.31 x 3.6 x 0.11 x 25 = 3.1 kN
Pile Cap = 0.31 x 0.4 x 0.4 x 25 = 1.2 kN
DL = 45.9 kN

LL Roof = 0 x 0 x 0.25 kPa = 0.0 kN


Floor = 0 x 0 x 1.5 kPa = 0.0 kN
Slab = 3 x 3.6 x 1.5 kPa = 16.2 kN

LL = 16.2 kN

TL = 62.1 kN

DL + LL = 68.3 kN

Screw Piles Driven to a Safe Working Load of 80 kN Date:01/10/2021


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 15
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

Screw Pile Capacity External - Garage Single

Loads = UDL
m m
DL Roof = 3.3 x 3.1 x 0.9 kPa = 9.2 kN
Wall = 2.9 x 3.1 x 2.5 kPa = 22.5 kN
Floor = 0 x 0 x 1 kPa = 0.0 kN
Slab = 1.7 x 3.1 x 3.2 kPa = 16.9 kN
E beam = 0.31 x 3.1 x 0.3 x 25 = 7.2 kN

DL = 55.8 kN

LL Roof = 3.3 x 3.1 x 0.25 kPa = 2.6 kN


Floor = 0 x 0 x 1.5 kPa = 0.0 kN
Slab = 1.7 x 3.1 x 2.5 kPa = 13.2 kN

LL = 15.7 kN

TL = 71.5 kN

DL + LL = 78.6 kN

Screw Piles Driven to a Safe Working Load of 80 kN

Screw Pile Capacity Internal - Garage

Loads = UDL
m m
DL Roof = 0 x 0 x 0.9 kPa = 0.0 kN
Wall = 0 x 0 x 0.35 kPa = 0.0 kN
Floor = 0 x 0 x 1 kPa = 0.0 kN
Slab = 2.8 x 3.1 x 3.2 kPa = 27.8 kN
E beam = 0.31 x 3.1 x 0.11 x 25 = 2.6 kN
Pile Cap = 0.31 x 0.4 x 0.4 x 25 = 1.2 kN
DL = 31.7 kN

LL Roof = 0 x 0 x 0.25 kPa = 0.0 kN


Floor = 0 x 0 x 1.5 kPa = 0.0 kN
Slab = 2.8 x 3.1 x 2.5 kPa = 21.7 kN

LL = 21.7 kN

TL = 53.4 kN

DL + LL = 58.7 kN

Screw Piles Driven to a Safe Working Load of 80 kN Date:01/10/2021


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 16
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

Screw Pile Capacity Garage Stepdown

Loads = UDL
m m
DL Roof = 6.7 x 1.9 x 0.9 kPa = 11.5 kN
Wall = 5.7 x 1.9 x 0.35 kPa = 3.8 kN
Floor = 2.2 x 1.9 x 1 kPa = 4.2 kN
Slab = 2.4 x 1.9 x 3.2 kPa = 14.6 kN
E beam = 0.31 x 1.9 x 0.3 x 25 = 4.4 kN

DL = 38.4 kN

LL Roof = 6.7 x 1.9 x 0.25 kPa = 3.2 kN


Floor = 2.2 x 1.9 x 1.5 kPa = 6.3 kN
Slab = 2.4 x 1.9 x 2.5 kPa = 11.4 kN

LL = 20.9 kN

TL = 59.3 kN

DL + LL = 65.2 kN

Screw Piles Driven to a Safe Working Load of 80 kN

Screw Pile Capacity LBW - Guest/Ensuite

Loads = UDL
m m
DL Roof = 0 x 1.8 x 0.9 kPa = 0.0 kN
Wall = 5.6 x 1.8 x 0.35 kPa = 3.5 kN
Floor = 4 x 1.8 x 1 kPa = 7.2 kN
Slab = 1.8 x 1.8 x 3.2 kPa = 10.4 kN
E beam = 0.31 x 1.8 x 0.11 x 25 = 1.5 kN
Pile Cap = 0.31 x 0.4 x 0.4 x 25 = 1.2 kN
DL = 23.9 kN

LL Roof = 0 x 1.8 x 0.25 kPa = 0.0 kN


Floor = 4 x 1.8 x 1.5 kPa = 10.8 kN
Slab = 1.8 x 1.8 x 2.5 kPa = 8.1 kN

LL = 18.9 kN

TL = 42.8 kN

DL + LL = 47.0 kN

Screw Piles Driven to a Safe Working Load of 80 kN Date:01/10/2021


CLICK ENGINEERING
Structural Civil Geotechnical & Land Surveying Sheet 17
First Floor 23-27 Railway Road Blackburn Job No. 2215220
Phone: 9894 4222 Designed: AW

Screw Pile Capacity P Load Under B1 TGT

Loads = UDL
m m
DL Roof = 2.4 x 1.3 x 0.9 kPa = 2.8 kN
Wall = 5.6 x 1.3 x 0.35 kPa = 2.5 kN
Floor = 0.45 x 1.3 x 1 kPa = 0.6 kN
Slab = 1.8 x 1.3 x 3.2 kPa = 7.5 kN
E beam = 0.31 x 1.3 x 0.3 x 25 = 3.0 kN
B1 P Load = 15.0 kN
DL = 31.5 kN

LL Roof = 2.4 x 1.3 x 0.25 kPa = 0.8 kN


Floor = 0.45 x 1.3 x 1.5 kPa = 0.9 kN
Slab = 1.8 x 1.3 x 2.5 kPa = 5.9 kN
B1 P Load = 16.0 kN
LL = 23.5 kN

TL = 55.0 kN

DL + LL = 60.5 kN

Screw Piles Driven to a Safe Working Load of 80 kN Date:01/10/2021