TENDER DOCUMENT
Tender No: H-GS-UBL-09-2023-24-02 Closing Date/Time: 29/04/2024 11:00
CPM/Gati Shakti/UBL acting for and on behalf of The President of India invites E-Tenders against Tender No H-GS-UBL-09-2023-24-02
Closing Date/Time 29/04/2024 11:00 Hrs. Bidders will be able to submit their original/revised bids upto closing date and time only.
Manual offers are not allowed against this tender, and any such manual offer received shall be ignored.
1. NIT HEADER
Hubli Division:- BAY-RDG Section: Provision of New Crossing Station with 03 running lines at
Name of Work
Badnahallu between SLM-RDG (Phase-1) Signalling and General Electrical arrangements
Bidding type Normal Tender
Tender Type Open Bidding System Single Packet System
Tender Closing Date Time 29/04/2024 11:00 Date Time Of Uploading Tender 16/03/2024 17:55
Pre-Bid Conference
No Pre-Bid Conference Date Time Not Applicable
Required
Advertised Value 51828652.24 Tendering Section GATISHAKTI
Bidding Style [ Decision at Schedule level ] Bidding Unit
Earnest Money (Rs.) 409200.00 Validity of Offer ( Days) 60
Tender Doc. Cost (Rs.) 0.00 Period of Completion 8 Months
Contract Type Works Contract Category Expenditure
Are Joint Venture (JV) firms
Bidding Start Date 15/04/2024 No
allowed to bid
Ranking Order For Bids Lowest to Highest Expenditure Type Capital (Works)
2. SCHEDULE
S.No. Item Code Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Unit
Above/
Schedule N-Electrical General 3233552.00
Below/Par
Please see Item Breakup for details. 3233552.00 AT Par 3233552.00
01
Description:- Electrical General
S.No. Item Code Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Unit
Above/
Schedule SA-Signaling (SOR) 3814263.24
Below/Par
Please see Item Breakup for details. 3814263.24 AT Par 3814263.24
01
Description:- Supply and Execution
S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Unit
Code
Above/
Schedule SB-Signaling (Non SOR) 40080812.23
Below/Par
Please see Item Breakup for details. 40080812.23 AT Par 40080812.23
02
Description:- Supply and Execution
S.No. Item Code Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Unit
Above/
Schedule TC-Telecom (Non SOR) 4700024.77
Below/Par
Please see Item Breakup for details. 4700024.77 AT Par 4700024.77
03
Description:- Supply and Execution
3. ITEM BREAKUP
12 12 Supply and making end termination with brass Each 8.00 418.00 3344.00
compression gland and aluminium lugs for 4 x 50 sqmm
size of PVC insulated and PVC sheathed / XLPE
aluminium conductor cable of 1.1 KV grade.
13 13 Supplying and making end termination with brass Each 50.00 370.00 18500.00
compression gland and aluminium lugs for 35 Sqmm
size, 4 core of PVC insulated and PVC sheathed /XLPE
aluminium conductor cable of 1.1 KV grade as specified
and directed.
14 14 Supplying and making end termination with brass Each 12.00 315.00 3780.00
compression gland and aluminium lugs for 25 Sqmm
size, 4 core PVC insulated and PVC sheathed /XLPE
aluminium conductor cable of 1.1 KV grade as specified
and directed.
15 15 Trenchless cutting to cross the cable across the track / RMT 100.00 1001.00 100100.00
road, duly supply and provided with HDPE pipe of size
90.9 x 76.5mm to pull LTUG cable & Fixing/laying of
HDPE pipe of size 90.9mm x 76.5mm as per instruction
of Engr-in-charge
16 16 "Supply, fixing, connecting, testing and commissioning Each 1.00 75550.00 75550.00
of LT Control Panel, cubical type, 125 A, 3 phase 4 wire
system with copper bus bars of size 20 x 5 mm,
opening from both front and rear sides, separate
compartments for each control gear, cable alley and
provision of knock out type entry plates suitable up to
120 sqmm size cables, panel made out of 14 SWG thick
CRCA sheet, epoxy powder coated with grey matt finish
, including base frame made out of 40 x 40 x 6 mm
angle iron sections, embedded in PCC 1:3:6 foundation,
consisting of the following switchgears and metering
devivces:- (i) MCCB 125 A, 4P, 36 KA, with with
Electronic / microprocessor based release - 01 No, (ii)
MCCB 100 A, 4P, 30 KA with electronic /
microprocessor based release. - 03 Nos (ii) MCB 63 A,
TPN, 10 KA, - 02 Nos Multi-function 3 phase meters
reading V, I, W, KVA, PFHz etc, including CTs, pilot
lamps complete all as specified and directed."
17 17 Supplying and fixing following way, horizontal type three Each 4.00 4974.00 19896.00
pole and neutral, sheet steel, MCB distribution board,
415 V, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc.
as required-6 way (4 + 18), Double door
18 18 Supplying and fixing 12 way, Double door, single pole Each 6.00 2315.00 13890.00
and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc.
as required-
19 19 Supplying and fixing 63 A rating, 415 V, 10 kA, "C" Each 12.00 2536.00 30432.00
curve, miniature circuit breaker suitable for inductive
load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as
required-Triple pole and neutral
20 20 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 Numbers 6.00 1228.00 7368.00
kA, "C" curve, miniature circuit breaker suitable for
inductive load of Triple pole and neutral in the existing
MCB DB complete with connections, testing and
commissioning etc. as required.
21 21 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 Each 30.00 656.00 19680.00
kA, "C" curve, Double pole miniature circuit breaker
suitable for inductive load of in the existing MCB DB
complete with connections, testing and commissioning
etc. as required.
36 36 Installation charges for split type air conditioner with Numbers 2.00 4981.00 9962.00
allied works for one indoor and one outdoor unit is to be
mounted on suitable Angle Iron support upto 3.0 Ton
split/cassette type A/C.
37 37 Supplying and installation of insulated refrigerant Metre 6.00 1631.00 9786.00
copper tubing of 5/8" and 3/8" with polythene foam
insulation 3 core 80 stand copper wiring between indoor
and outdoor unit Leak testing oil and gas charging for
additional piping length of tube
38 38 Supply of voltage stabilizer suitable for 1 /1.5 Ton AC Numbers 2.00 2616.00 5232.00
Total 3233552.00
Schedule Schedule SA-Signaling (SOR)
Item- 01 Supply and Execution
S No. Item Description of Item Unit Qty Rate Amount
No
1 1 Excavation of cable trench in all kinds of soil except Metre 4000.00 53.70 214800.00
hard rocky areas including clearing of roots of trees,
rocks, bushes etc. to a depth of 1.0 Mtrs and to a width
of 0.3 Mtrs. Laying of cables is not included in this
schedule.
2 2 Excavation of cable trench in all kinds of soil except Metre 2000.00 66.61 133220.00
hard rocky areas including clearing of roots of trees,
rocks, bushes etc. to a depth of 1.0 Mtrs and to a width
of 0.5 Mtrs. Laying of cables is not included in this
schedule.
3 3 Excavation of trench to a depth of 1 Mtr. for track Metre 100.00 322.94 32294.00
crossing of cables, laying of DWC/ RCC pipes with
collar/coupling, refilling of trench by ramming and
consolidating it as per the instructions of Railway
representative at site. During excavation of trench it has
to be ensured that the excavated soil does not mix with
the ballast available. The depth of 1m trench shall be
from the bottom of sleepers for track crossings. Laying
of cables is not included in this schedule. (Supply of
DWC/RCC pipes with couplers/ collars is not included in
this schedule)
4 4 Excavation of trench to a depth of 1 Mtr. for road Metre 100.00 419.78 41978.00
crossing of cables, laying of DWC/ RCC pipes with
collar/ coupling, refilling of trench by ramming and
consolidating it and resurfacing it to the original
position. Laying of cables is not included in this
schedule. (Supply of DWC/RCC pipes with couplers/
collars is not included in this schedule).
5 5 Provision of GI pipes (50/100mm dia) for cable laying Metre 100.00 282.02 28202.00
with offset at both ends and with couplings over RCC
Bridges/ Drainage/ Culverts with concrete masonry
supports of size 300mm x 300 mm x 300 mm at an
interval of 2m. The ends of the pipes shall be closed
with brick masonry abutments work so that no cable is
exposed, The work shall be carried out as per the
instructions of Railway representative at site. (Supply of
GI pipes with couplings and laying of cables is not
included in this schedule). [Stone jelly of size 20/25mm,
bricks, sand, cement and all other miscellaneous
materials required for the work shall be supplied by the
Contractor].
6 6 Provision of GI pipes-(50/100mm dia) for cable laying Metre 100.00 333.63 33363.00
with offset at both ends and with couplings over girder
bridges by fixing on suitable MS Clamps at an interval
of 2 Mtrs. The ends of the pipes shall be closed with
brick masonry abutments work so that no cable is
exposed, The work shall be carried out as per the
instructions of Railway representative at site. (Supply of
GI pipes with couplings and laying of cables is not
included in this schedule). [MS angles, flats, bolts and
nuts for manufacturing fixing clamps, bricks, river sand ,
cement and all other miscellaneous required for the
work shall be supplied by the Contractor].
7 7 Provision of GI pipes (50/100mm dia) for cable laying in Metre 200.00 260.52 52104.00
hard rocky area with off sets at both ends duly
supported by concrete blocks of size 300mm x 300 mm
x 300 mm at an interval of 2m. The ends of the pipes
shall be closed with brick masonry abutments work so
that no cable is exposed, The work shall be carried out
as per the instructions of Railway representative at site.
(Supply of GI pipes with couplings and laying of cables
is not included in this schedule). [Stone jelly of size
20/25mm, bricks, sand, cement and all other
miscellaneous materials required for the work shall be
supplied by the Contractor].
8 8 Laying of signaling/power/telecommunication cables as Metre 15000.00 15.23 228450.00
per cable plan in cable trenches, masonry ducts, RCC
Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not
included in this schedule).
9 9 Refilling of cable trench 1m depth by 0.3m width Metre 4000.00 12.91 51640.00
throughout, with earth after laying of cables, and
consolidating the trench by ramming and leveling
10 10 Refilling of cable trench 1m depth by 0.5m width Metre 2000.00 16.16 32320.00
throughout, with earth after laying of cables, and
consolidating the trench by ramming and leveling.
11 11 Supply of RCC cable markers as per drawing Numbers 130.00 257.74 33506.20
No.CSTE/CN/OFC/1. The lettering on the cable marker
shall be "SIG" / "TELE" / "OFC" as per the instructions
of Railway representative at site.
12 12 D i g g i n g o f p i t t o a d e p t h o f 8 0 0 m m o f size Numbers 130.00 188.21 24467.30
300mmX300mm, casting of concrete foundation of size
300mmX300mmX300mm a n d Placing of R C C cable
markers on top of the foundation and refilling the pit
and consolidating it by ramming. The cable markers
shall be provided at an interval of 20 Mtrs. within station
limits and 50 Mtrs. outside station limits throughout the
cable route, diversions and also at every track/road
crossing.
13 13 Excavation of cable coil pit to a size of 1.5mx1.5m and cum 20.00 795.15 15903.00
depth as instructed by Railway representative at site,
for coiling the cables in rear of relay rooms/ AFTC huts,
apparatus cases etc. The work includes coiling the
underground cables, and placing closely one layer of
country bricks of size approx. 220mm x 100mm x
60mm breadth wise above the cables to cover all the
cables in the cable pit, closing and consolidating the pit
by ramming and leveling. [Country bricks of size
220mmx100mmx60mm (approximately) shall be
supplied by the Contractor]
14 14 Supply of GI pipes - 50mm dia -3.65mm thick as Metre 100.00 531.96 53196.00
specified in Vol.II of the Tender document
15 15 Excavation of pit, casting concrete foundation and Numbers 30.00 15306.71 459201.30
erection of apparatus case full size as per Drg.
No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks,
one for the front door and another for the back door,
fixing of one hard wood shelf plank 37mm thick and
painting the apparatus case inside and outside with one
coat of red- oxide and two coats of aluminium paints.
(Supply of apparatus case is not included in this
schedule). [Foundation bolts & nuts, 'E' type locks,
cement, river sand, stone jelly of size 20/25 mm,
hardwood plank of 37mm thick, paints, varnish, fixing
bolts & nuts and all other miscellaneous materials
required for the work shall be supplied by the
Contractor.]
16 16 Excavation of pit, casting concrete foundation and Numbers 12.00 10798.23 129578.76
erection of apparatus case half size as per Drg,
No.SG/CN/02/7, fixing one 'E' type lock for the front
door and latching arrangement for the back door, and
fixing of one hardwood shelf plank 37mm thick and
painting the apparatus case inside and outside with one
coat of red-oxide and two coats of aluminium paints.
(Supply of apparatus case is not included in this
schedule). [Foundation bolts and nuts, cement, 'E' type
locks, river sand, stone jelly of size 20/25mm, 37mm
hard wood planks, latching arrangements, paints,
varnish, fixing bolts & nuts and all other miscellaneous
materials required for the work shall be supplied by the
Contractor]
17 17 Termination of main, tail, Signaling and power cables Numbers 2000.00 144.39 288780.00
on PBT Termination 25/60mm on Phynolic sheet and
internal wiring on terminal/ fuse blocks in new
apparatus cases, cable termination boxes and in gate
Lodges excluding cable termination rack at relay room.
The work includes fixing of all new cables by teakwood
clamp on teakwood base plank, fixing of Phynolic
synthetic industrial fibre base fine weave cotton fibre
board 6mm thick for terminal board to suit each
apparatus case, varnishing all teakwood items, fixing of
terminals/ fuse blocks on the terminal board, drilling of
necessary holes, termination of cables, wiring,
identification of cables using aluminium tags with letters
punched neatly, as per approved circuit diagram and
cable plan, painting of particulars on sleeves and also
on the inner side of the doors of apparatus cases. After
terminations are over, the side openings of apparatus
case foundation shall be closed with brick work, cement
plastered, the inter-space filled with river sand up to
base level and the bottom surface shall be sealed with
sealing compound. (Supply of PBT terminals and Fuse
blocks is not covered in this schedule). [Cement,
teakwood cable clamp.
18 18 Termination of main, tail, Signaling and power cables Numbers 200.00 176.01 35202.00
on Fuse blocks on Phynolic sheet and internal wiring on
terminal/ fuse blocks in new apparatus cases, cable
termination boxes and in gate Lodges excluding cable
termination rack at relay room. The work includes fixing
of all new cables by teakwood clamp on teakwood base
plank, fixing of Phynolic synthetic industrial fibre base
fine weave cotton fibre board 6mm thick for terminal
board to suit each apparatus case, varnishing all
teakwood items, fixing of terminals/ fuse blocks on the
terminal board, drilling of necessary holes, termination
of cables, wiring, identification of cables using
aluminium tags with letters punched neatly, as per
approved circuit diagram and cable plan, painting of
particulars on sleeves and also on the inner side of the
doors of apparatus cases. After terminations are over,
the side openings of apparatus case foundation shall be
closed with brick work, cement plastered, the inter-
space filled with river sand up to base level and the
bottom surface shall be sealed with sealing compound.
(Supply of PBT terminals and Fuse blocks is not
covered in this schedule). [Cement, teakwood cable
clamp.
19 19 Manufacture and supply of M.S. relay frames of suitable Set 2.00 4143.53 8287.06
size to hold up to 4 relays plug in type HMU as required
by Railways and fixing them in apparatus cases for all
types of signal control circuits, LC gate control circuit
and Point control circuits, fixing of plug boards, relays,
resistors and electrolytic condensers on Phynolic
synthetic industrial fibre base fine weave cotton fibre
sheet - 6mm thick to IS specification 2036 - 1995 - Type
F5, wiring and termination as per approved circuit
diagram and painting the particulars. (Supply of all
types of relays, plug boards, connectors, retaining clips
and plug in type HMU is not covered in this schedule).
[Wire PVC copper, 3/0.75mm and 16/0.2mm copper,
Phynolic synthetic industrial fibre base fine weave
cotton fibre sheet - 6mm thick to IS specification 2036 -
1995 - Type F5, for fixing resistors and condensers, MS
flats 25mm x 6mm brass bolts and nuts, paints,
soldering materials, resistors, condensers and all other
miscellaneous materials required for the work shall be
supplied by the contractor].
20 20 Manufacture and supply of M.S. relay frames of suitable Set 8.00 7346.00 58768.00
size to hold up to 8 relays plug in type HMU as required
by Railways and fixing them in apparatus cases for all
types of signal control circuits, LC gate control circuit
and Point control circuits, fixing of plug boards, relays,
resistors and electrolytic condensers on Phynolic
synthetic industrial fibre base fine weave cotton fibre
sheet - 6mm thick to IS specification 2036 - 1995 - Type
F5, wiring and termination as per approved circuit
diagram and painting the particulars. (Supply of all
types of relays, plug boards, connectors, retaining clips
and plug in type HMU is not covered in this schedule).
[Wire PVC copper, 3/0.75mm and 16/0.2mm copper,
Phynolic synthetic industrial fibre base fine weave
cotton fibre sheet - 6mm thick to IS specification 2036 -
1995 - Type F5, for fixing resistors and condensers, MS
flats 25mm x 6mm brass bolts and nuts, paints,
soldering materials, resistors, condensers and all other
miscellaneous materials required for the work shall be
supplied by the contractor].
21 21 Manufacture and supply of M.S. relay frames of suitable Set 4.00 9513.66 38054.64
size to hold up to 12 relays plug in type HMU as
required by Railways and fixing them in apparatus
cases for all types of signal control circuits, LC gate
control circuit and Point control circuits, fixing of plug
boards, relays, resistors and electrolytic condensers on
Phynolic synthetic industrial fibre base fine weave
cotton fibre sheet - 6mm thick to IS specification 2036 -
1995 - Type F5, wiring and termination as per approved
circuit diagram and painting the particulars. (Supply of
all types of relays, plug boards, connectors, retaining
clips and plug in type HMU is not covered in this
schedule). [Wire PVC copper, 3/0.75mm and 16/0.2mm
copper, Phynolic synthetic industrial fibre base fine
weave cotton fibre sheet - 6mm thick to IS specification
2036 - 1995 - Type F5, for fixing resistors and
condensers, MS flats 25mm x 6mm brass bolts and
nuts, paints, soldering materials, resistors, condensers
and all other miscellaneous materials required for the
work shall be supplied by the contractor].
22 22 Manufacture and supply of M.S. relay frames of suitable Set 4.00 11392.42 45569.68
size to hold up to 20 relays plug in type HMU as
required by Railways and fixing them in apparatus
cases for all types of signal control circuits, LC gate
control circuit and Point control circuits, fixing of plug
boards, relays, resistors and electrolytic condensers on
Phynolic synthetic industrial fibre base fine weave
cotton fibre sheet - 6mm thick to IS specification 2036 -
1995 - Type F5, wiring and termination as per approved
circuit diagram and painting the particulars. (Supply of
all types of relays, plug boards, connectors, retaining
clips and plug in type HMU is not covered in this
schedule). [Wire PVC copper, 3/0.75mm and 16/0.2mm
copper, Phynolic synthetic industrial fibre base fine
weave cotton fibre sheet - 6mm thick to IS specification
2036 - 1995 - Type F5, for fixing resistors and
condensers, MS flats 25mm x 6mm brass bolts and
nuts, paints, soldering materials, resistors, condensers
and all other miscellaneous materials required for the
work shall be supplied by the contractor].
23 23 Excavation of pit, casting concrete foundation as per Numbers 10.00 7762.71 77627.10
Drg.No.SG/CN/02/9 using metallic templates, for
erection of colour light signals up to 4 aspects.
[Foundation bolts, cement, river sand, stone jelly of size
20/25mm dia and all other miscellaneous materials
required for the work shall be supplied by the
Contractor].
24 24 Erection of surface base, signal pole, mounting of Numbers 10.00 8526.86 85268.60
colour light signal up to 4 aspects complete on Signal
pole/ Off- set bracket, (for LED/ filament bulbs) with
lenses, triple pole lamp holder, filament switching units,
CLS transformer, current regulators (whichever is
applicable), fixing of ladder with platform complete and
concreting of ladder shoe, fixing of number plates,
marker board, lens guard, fixing of speed limit board
wherever necessary, termination of tail cables, wiring of
signal unit with PVC wire 3/0.75mm copper, provision of
EWS locks, and painting of one coat of red oxide and
two coats of aluminium/ enamel paints. When the
aspect is fixed on Offset bracket using 'U' bolts and
nuts, a through bolt shall be provided by drilling a hole
in the signal pole to prevent the offset bracket from
sliding down. (Supply of surface base, Offset bracket,
CLS pole, CLS aspects complete, ladder with shoes
and platform, Speed limit board, LED aspects, current
regulators, lamp holders, lamps, filament switching unit
and CLS transformer is not covered in this schedule).
['U' bolts and nuts, through bolts and nuts, cement,
stone jelly
25 25 Excavation of pit and casting concrete foundation as Numbers 2.00 3903.75 7807.50
per Drg, No.SG/CN/02/10 using metallic templates, for
erection of ground type colour light shunt signal.
[Foundation bolts and nuts, cement, river sand, stone
jelly of size 20/25mm and all other miscellaneous
materials for the work shall be supplied by the
Contractor].
26 26 Erection of Ground type shunt signal complete including Numbers 2.00 3250.35 6500.70
surface base, signal pole, LED aspects/ lenses, bulbs
with holders (whichever is applicable), fixing of lens
guards, number plate, termination of tail cables, wiring
of signal unit with PVC wire 3/0.75mm copper, provision
of EWS locks and painting of one coat of red oxide and
two coats of Aluminium/ enamel paint. (Supply of
Ground type shunt signal complete including surface
base, signal pole, LED aspects, holder, bulbs, and
lenses is not covered in this schedule). [Wire PVC
3/0.75mm copper, lens guards, EWS locks, Enameled
number plates, bolts and nuts, lead wool, paints and all
other miscellaneous materials shall be supplied by the
Contractor].
27 27 Fixing of Offset brackets using 'U' bolts and nuts, Numbers 2.00 2500.53 5001.06
erection of Post type shunt Signals, termination of tail
cables and wiring using wire PVC 3/0.75mm copper,
provision of EWS lock and painting of one coat of
redoxide and two coats of aluminium/ enameled paint.
The work also includes drilling suitable holes on the
CLS post and provision of a through bolt with nut to
prevent the Off-set bracket from slipping down. (Supply
of Post type Shunt Signals, LED aspects and Off set
brackets is not covered in this schedule). ['U' bolts and
nuts, through bolts with nut, wire PVC 3/0.75mm
copper, EWS lock, Enameled number plates, wire
mesh, PVC/Nylon sleeves, paints and all other
miscellaneous materials shall be supplied by the
contractor].
28 28 Fixing of junction type route indicators - 2 way Numbers 2.00 2827.20 5654.40
complete/ fixing of additional limb to the existing route
indicators, termination of tail cables, wiring as per
approved circuits diagram using wire PVC 3/0.75mm
copper, provision of required No of EWS locks, wire
mesh, and painting. (Supply of junction type Route
Indicators - complete and additional limb is not covered
in this schedule). [3/0.75mm wire PVC, fixing bolts and
nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints
and all other miscellaneous materials shall be supplied
by the Contractor].
29 29 Fixing of Offset brackets using 'U' bolts and nuts, Numbers 6.00 2212.23 13273.38
erection of Calling On Signals/ 'A' marker lights,
termination of tail cables and wiring using wire PVC
3/0.75mm copper, provision of EWS lock, number
plates/ marker boards and painting. The work also
includes drilling suitable holes on the CLS post and
provision of a through bolt with nut to prevent the Offset
bracket from slipping down. (Supply of Calling On
Signal/ 'A' marker light, LED aspects/holders & bulbs
and Off set brackets is not covered in this schedule).
['U' bolts and nuts, through bolts with nut, wire PVC
3/0.75mm copper, EWS lock, Enameled number plates,
wire mesh, PVC/Nylon sleeves, paints and all other
miscellaneous materials shall be supplied by the
contractor].
30 30 Supply and provision of Screening arrangement for Numbers 4.00 1575.73 6302.92
Signals in RE area as per standard practice. The work
comprises of providing MS angle frame and wire mesh
in order to avoid close proximity of OHE wires. The
work also includes provision of earthing wire using 4
SWG GI wires from the screening arrangement up to
surface base as per the instructions of Railway
representative at site. [All materials required for this
work shall be supplied by the Contractor
31 31 Provision of earth electrodes as per drawing Numbers 25.00 2788.45 69711.25
No.SG/SN/02/13 and earthing of metallic sheath and
armour of all cables in all apparatus cases, relay room,
equipment room, ASM room for block and control, and
earthing of all equipments in apparatus cases, power
room, relay rack, cable termination rack, control panel,
signals, lever frames with MS flat 35mm X 6mm/19c
cable (MS flat for closer by areas and MS flat/19c cable
combination for farther areas) as per the instructions of
Railway representative at site. The work includes
painting of earth resistance value on the earth pit.
(Supply of 19C cable is not covered in the scope of this
schedule). [MS flat for earthing 35mm X 6mm, cement,
GI earth electrodes, common salt, charcoal, country
bricks, river sand, soldering materials and all other
miscellaneous materials required for the work shall be
supplied by the Contractor].
32 32 Installation of combined type point machine - IRS type Numbers 4.00 13727.03 54908.12
and connecting all ground connections including wiring
and termination in point machine and interconnections
between point machine and CT box through PVC hose
pipe with 3/0.75mm and 7/1.40mm copper wire and
painting. This work includes provision of insulation to
stretcher bars, throw bar lug and "D" bracket wherever
required, cutting of notches on the point machines
covers to suit crank handle configuration. (Combined
type point machine with ground connection, uninsulated
stretcher bar, throw bar lug and 'D' brackets will be
supplied by Railways. [All types of insulations connected
to point work, coal bengal, all type of bolts and nuts,
washers spring/flat wire PVC 7/1.4mm copper, PVC
hope pipe, paints, PVC/nylon sleeves and all other
miscellaneous materials required for the work shall be
supplied by the Contractor].
33 33 Supply of Colour light Signal pole 140mm dia, 4.6m tall Numbers 4.00 5142.90 20571.60
with necessary inspection as per specification/ drawing/
description enclosed in this document.
34 34 Supply of Colour light Signal pole 140mm dia, 3.6m tall Numbers 8.00 4609.70 36877.60
with necessary inspection as per specification/ drawing/
description enclosed in this document.
35 35 Supply of surface base to suit CLS Signal pole 140mm Numbers 12.00 6382.90 76594.80
dia with necessary inspection as per specification/
drawing/ description enclosed in this document
36 36 Supply of ladder with platform and shoes to suit CLS Numbers 4.00 4964.65 19858.60
pole 4.6m tall, with necessary inspection as per
specification/ drawing/ description enclosed in this
document.
37 37 Supply of ladder with platform and shoes to suit CLS Numbers 8.00 4787.95 38303.60
p o l e 3.6m tall, with necessary inspection as per
specification/ drawing/ description enclosed in this
document.
38 38 Supply of post type shunt signal - complete with hood Numbers 4.00 4433.00 17732.00
etc., with necessary inspection as per specification/
drawing/ description enclosed in this document.
39 39 Supply of Ground type shunt signal - complete with Numbers 2.00 6382.90 12765.80
surface base, signal pole, hood etc., with necessary
inspection as per specification/ drawing/ description
enclosed in this document
40 40 Supply of Colour Light Signal Multi Unit type - complete Numbers 6.00 15958.80 95752.80
f o r 3 aspect with mounting socket, with necessary
inspection as per specification/ drawing/ description
enclosed in this document.
41 41 Supply of Colour Light Signal Multi Unit type - complete Numbers 4.00 13299.00 53196.00
f o r 2 aspect with mounting socket, with necessary
inspection as per specification/ drawing/ description
enclosed in this document.
42 42 Supply of Junction type route indicator - 5 unit arm - 2 Numbers 2.00 22165.00 44330.00
way.
43 43 Supply of Calling On Signal l i g h t complete with Numbers 6.00 3191.45 19148.70
necessary inspection as per specification/ drawing/
description enclosed in this document.
44 44 Supply of Off-set brackets Large made of cast iron with Numbers 2.00 3191.45 6382.90
as per specification/ drawing/ description enclosed.
45 45 Supply o f Off-set brackets small made o f cast iron as Numbers 4.00 2304.85 9219.40
per specification/ drawing/ description enclosed.
46 46 Supply of PBT terminals 25mm center as per Numbers 1000.00 68.20 68200.00
specification/ drawing/ description enclosed.
47 47 Supply of PBT terminals 60mm center as per Numbers 300.00 93.00 27900.00
specification/ drawing/ description enclosed.
48 48 Supply of apparatus cases Full size to suit South Numbers 30.00 18618.60 558558.00
Western Railway standard with necessary inspection as
per specification/ drawing/ description enclosed.
49 49 Supply of apparatus cases Half size to suit South Numbers 12.00 13299.00 159588.00
Western Railway standard with necessary inspection as
per specification/ drawing/ description enclosed.
50 50 Supply of QBCA1 - heavy duty contact relays with plug Numbers 10.00 6417.00 64170.00
board ,retaining clip and connectors and with necessary
inspection as per specification/ drawing/ description
enclosed in this document
51 51 Supply and provision of Rubber mat of not less than Square 100.00 121.36 12136.00
6mm thick and with an insulation to withstand 650VAC, Foot
on the floor of relay room etc at places as indicated by
railway representative at site.
52 52 Supply and installation of teakwood glass fronted box of Numbers 2.00 6288.35 12576.70
size 300mm x 600mm x 75mm with hooks to keep
various keys with description engraved on the tags. [TW
Glass fronted box of size 300mmx600mmx 75mm with
built in lock, hooks, engraved tags and all other
miscellaneous materials required for the work shall be
supplied by the Contractor].
53 53 Fixing of EKT instrument with (or) without crank handle Numbers 2.00 4562.81 9125.62
or on suitable fixtures at station/apparatus case,
provision of economiser push switch with locking facility,
wiring with wire PVC 16/0.2mm copper, provision of
teakwood terminal box covered with decolum along with
locking facility and painting. (Supply of electric key
transmitter and crank handles is not covered in this
schedule). [wire PVC 16/0.2mm copper, wire wound
resistance, decolum covered terminal box with locking
facility by using 25mm thick teakwood, bolts and nuts,
paints, push switches, padlocks and other
miscellaneous materials required for this work shall be
supplied by the contractor].
54 54 Designing of Signalling plan in AUTOCAD 2000 or latest Per 1.00 7999.55 7999.55
and submission of negatives in 80/90 gsm tracing paper Station
in 'U' size along with 2 copies and also the soft copy in per
compact disks induplicate. First, 2 sets of prints shall be Month
supplied to Railways for checking. One set will be
returned by Railways to the contractor for making
corrections in AUTOCAD. The final corrected drawings
shall be supplied to Railways on 80/90 gsm tracing
paper and 2 CDs. [2 interlocked sidings will be
considered equal for one loop line] (Approved
permanent way plan will be supplied by ailways).a.For
Stations upto 4 Roads.(Per Station)
55 55 Designing of circuits diagrams/ table of control in Sheet 40.00 912.64 36505.60
AUTOCAD 2000 or latest (including contact numbers on
the circuit) and submission of negatives in 80/90 gsm
tracing paper in 'A3' size along with 2 copies and also
the soft copy in compact disks induplicate. First, 2 sets
of prints shall be supplied to Railways for checking. One
set will be returned by Railways to the contractor for
making corrections in AUTOCAD. The final corrected
drawings shall be supplied to Railways on 80/90 gsm
tracing paper and 2 copies of blue prints and the soft
copy in 2 CDs. (Approved Signalling plan will be
supplied by Railways for preparing table of control.
Approved table of control will be supplied by Railways
for preparing circuits diagrams).Per Sheet.
56 56 Transportation of Signaling materials more than 100 Per Unit 1000.00 11.65 11650.00
Kms. by road as per the instructions of Railway
representative at site. The work also includes loading
and unloading of the materials {Unit: per Ton per KM}
57 57 Engaging mechanical excavators like JCB or other Hour 24.00 1007.50 24180.00
machineries for regarding and levelling the formation,
dismantling any infringing structures, clearing and
removing debris etc., with all leads and lifts etc.,
complete and as per the instruction of Railway
representative at site.
Total 3814263.24
Schedule Schedule SB-Signaling (Non SOR)
Item- 02 Supply and Execution
S No. Item Description of Item Unit Qty Rate Amount
No
1 1 Supply of Cable termination r a c k s s i z e 880mmX2 Numbers 2.00 7825.75 15651.50
M e te r s made out o f 50mmX50mmX6mm t h i c k MS
angle POWDER COATED with stainless steel nuts and
bolts for fixing the racks with suitable holes f o r hylem
sheet complete as per standard practice w i t h tripod
b a s e s a n d reel insulators. C a b l e l a d d e r of
400mmx2000mm be provided at both sides with angle
size 40mmx4mmx5mm w i t h supporting f l a t o f size
25mmx5mm.
2 2 Supply of ARA Terminal block 6 Way, 25 mm Centre, Numbers 1000.00 362.25 362250.00
made up of PBT a s p e r RDSO Drg.No. S A . 23756/
Adv/Alt.3, confirming to Specification No. IRS.S.75/2006
(Rev.2) or latest.
3 3 Supply of High Density Polyethylene Pipes (HDPE) of Metre 200.00 776.25 155250.00
110 mm Outer Dia, 10 m m Wall Thickness, along with
one coupler for every 6 Meters as per specification No.
IS 4984: 2 0 1 6 wit h latest amendments a n d Material
Grade:PE 80.
4 4 Supply of High Availability Single Section Digital Axle Set 1.00 1083024.00 1083024.00
counter( HA- SSDAC) with Dual Track Sensor Devices
as per RDSO specification N o . RDSO/SPN/177/2012
version 3 . 0 or latest (Phase Reversal Type) as per
details given below a) Configuration - 2 DP 1 section b)
Length o f cable required with each track device- 15
mtrs.Should be compatiable with the existing system at
site.
5 5 Supply of Basic material to construct Unit Maintenance Set 15.00 26197.00 392955.00
Free Earth as per RDSO Spec No. RDSO/
SPN/197/2008 or latest and as per relevant Technical
specification
6 6 Supply o f 50x6 m m G I Tape for interconnecting earth Metre 40.00 573.85 22954.00
electrodes
7 7 Supply of 35 S q m m Multi-strand Single C o r e PVC Metre 100.00 512.90 51290.00
insulated Copper Cable as per IS: 694 for connecting
Main Earth Electrode to MEEB in the equipment room.
Color: Green
8 8 Supply of 16 S q m m Multi-strand Single C o r e PVC Metre 100.00 228.85 22885.00
insulated Copper Cable a s per IS: 6 9 4 f o r connecting
MEEB to SEEB and SPDs to MEEB. Color: Green
9 9 Supply of 10 S q m m Multi-strand Single C o r e PVC Metre 100.00 143.75 14375.00
insulated Copper Cable as per IS: 694 for connecting
SEEB to all equipments. Color: Green
10 10 Supply of Earth L e a ka g e detector 1 2 channel (4 Numbers 1.00 150980.05 150980.05
Channels- 110V AC, 2 Channels- 110V DC , 6
Channels- 24V DC) as per RDSO Spec./256/2002 or
latest with 6 digit counter.
11 11 Supply of AC/DC Digital Clamp meter Current Numbers 1.00 6810.30 6810.30
measurement upto 200A AC/DC True RMS
measurement for AC voltage & current.(Large jaw
opsize of 18mm ) Model: FLUKE 362/Rishabh or higher
specification.
12 12 Supply of Steel Almirah (Model : Godrej Store Numbers 2.00 26126.85 52253.70
well/slimline 4S )
13 13 Supply of Step ladder Aluminium made of BATHLA Numbers 1.00 10490.30 10490.30
make or better of App. 5 feet height.
14 14 Supply of Flex printing with Sun board fixing o f various Square 150.00 516.35 77452.50
drawing with Colour (Power board diagram,Relay index Foot
chart,Station Rule Diagram, FTOT Particulars, etc), as
p e r i n s t r u c t i o n s o f S i t e I n - C h a r g e Railway
Representative.
15 15 Supply of Printed a n d b o u n d e d registers including Numbers 100.00 250.70 25070.00
maintanance registers for SSDAC, point machine, track
circuit etc. (100 Pages each of 75 gsm paper)
16 16 Supply of UL standard PPT C fu se s complies t o UL Numbers 50.00 47.15 2357.50
Themistor standard 1434 with rating -2 Amps, make
LITTLE FUSE, FUZETEC, TYCO, BOURN, RAYCHEM
or Better.
17 17 Erection of CT Rack with scaffolding suitably concreting Numbers 2.00 5038.15 10076.30
tri-pod bases and reel insulators with "J" bolts and nuts.
Tripod and other supporings are to be painted in 2
coats with enamel.
18 18 Track crossing b y Horizontal Boring Method based on Metre 100.00 2603.60 260360.00
RDSO Report No. BS - 105. This also includes insertion
of HDPE Pipe o f 110mm Outer dia i n the Bore drilled.
(Supply of HDPE Pipe is not included).
19 19 Termination of Main, Tail, Signalling and power cables Per Unit 1200.00 165.60 198720.00
a n d internal wiring o n terminal/ f u se blocks i n cable
termination Rack at relay room. The work includes
fixing of all new cables by teakwood clamp on teakwood
base plank, fixing o f Hyle m sh e e t 1 0 m m th ick for
terminal board , varnishing all teakwood items, fixing of
terminals/ fuse blocks on the terminal board, drilling of
necessary holes, te r m in a tio n o f c a b l e s , wiring,
identification of cables using aluminium tags with letters
punched neatly, as per approved circuit diagram and
cable plan, painting of particulars o n sleeves . After
terminations are over, cable entry at the bottom shall be
closed with , cement plastered, t h e inter-space filled
with sand upto base level and the bottom surface shall
be sealed with sealing compound. Cable armour t o be
soldered to earth. (Supply of cable termination racks is
not included in this schedule). [All bolts and nuts with
washers, Hylum Sheet 10 m m Thick, cement, sand,
sto n e jelly, T e a k wood base , paints a n d a l l other
miscellaneous materials required for the work shall be
supplied by the contractor]a. Termination o n 25/60mm
PBT terminals {Per Unit-Per Terminal}
20 20 Installation, testing and commissioning of Single Section Set 1.00 58077.30 58077.30
digital Axle counter (SSDAC) with High Availability. HA-
SSDAC to be installed, wired, tested and commissioned
b y O E M a s p e r guidelines issued b y RDSO , wiring
d iscip lin e s h o u l d b e a s p e r R D S O T A N No.
STS/E/TAN/6001 Ve r sio n 1 . 0 o r l a t e s t . T h e pre-
commissioning checklist issued by RDSO for SSDAC to
b e prepared b y O E M a n d jointly signed b y O E M &
Railway. Before commissioning o f HA-SSDAC, OEM
should submit site installation certificate.
21 21 Provision o f 2 Machine c u t grooves i n parallel a t a Metre 100.00 775.10 77510.00
separation of 8 cms each to a depth of 150 mm in the
platform surfaced/tiled floor for laying cable.
22 22 L a y i n g o f H D P E p i p e 1 1 0 m m O u t e r D i a , 10mm Metre 100.00 63.25 6325.00
Thickness along with collars i n trenches a t places of
platform cutting etc., and wherever required as per the
instructions of site engineer.
32 32 Providing services of helping hand man power t o carry Man- 90.00 572.70 51543.00
o u t miscellaneous/sundry w o r k s i n t h e office/field Days
between 0 8 .0 0 h r s a n d 2 0 .0 0 h r s o f t h e d a y and
accompanying Ra ilwa y s t a f f w i t h a l l e xp e n se s of
transportation, accomodation, food, consumables etc.,
w i t h a l l ascents/descents, ta xe s, octroi, c e s s , fees,
duties, w i t h contractors t o o l s a n d plants, materials,
consumables, labour, crew, machineries wit h a l l lead
a n d l i f t e t c . , co m p le te a s p e r sp e cia l conditions,
specification, regulation a n d a s directed b y Railway
Engineer-in-charge.
33 33 Preparation o f Ca b le Ro u te Pla n , Ca b le C o r e Plan, Station 1.00 112740.25 112740.25
C a b l e Termination R a c k Particulars, L o ca tio n Box
Particulars, P o w e r S u p p l y Dia g r a m , T r a c k Circuit
Bonding Diagram and/or a n y other drawing o n Auto-
C A D i n A2/A3/ A 4 , e t c . s i z e ( a s p e r instructions of
Engineer in-charge). Initially Contractor shall submit 2
sets of 'AS PLANNED' documents complete for
approval of Railways. One set is returned either duly
approved for making a fair copy or for re-submission for
approval after incorporating the changes as required by
railways. After preliminary approval, execution o f work
shall be carried out at site. After Completion of work, 2
s e t s of 'AS M ADE' Ch e ck Pr in ts a r e submitted for
Administarative approval. Railways will return one set to
the contractor duly approved with
alterations/corrections if a n y . T h e contractor shall
incorporate Railways alterations/corrections i n the
tracings without any deviation and submit all tracings
complete in all respect along with its soft copies in USB
Pen Drive and 6 sets of final completion drawings in
properly b o u n d booklets. [For Centralized Electronic
Interlocking Stations/Small Stations]
34 34 Supply and fixing of retro-reflective type Goods Warning Numbers 2.00 9053.95 18107.90
Boards a s p e r practice & SEM(Angle/Rail is to be
supplied by Railway).
35 35 Su p p l y a n d f i x i n g o f retro-reflective t y p e Calling- Numbers 4.00 7120.80 28483.20
On/STOP/BSLB/Legend /Axel Counter boards a s per
practice & SEM (Angle/Rail is to be supplied by
Railway).
36 36 Supply and placing of trunking and capping (RCC Duct ) Numbers 2300.00 1469.70 3380310.00
of 500mm width as per Drg.No SDO/Cable laying /007
RDSO/SI/G/2010
37 37 Supply and laying of Split DWC pipe of 120/103 mm dia, Per Unit 200.00 326.60 65320.00
2 meter long in already dug cable trenches. The unit of
RMT means two split pipes of 1 Mtr each. Material shall
be supplied as per specification RDSO/SPN/204/2011
or latest" {Per Unit-RMT}
38 38 Supply and Installation of Pre-wired Crank Handle Cum Numbers 1.00 39873.95 39873.95
Key Lock Relay Box (of MS Sheet) along with LEDs,
with approved t y p e p u s h buttons, W a g o o r similar
Disconnecting type Terminal Blocks inlcuding D I N rail
e tc., a s p e r tentative drawing enclosed. Installation,
fixing and wiring o f boxes f o r Ke y Lock Relays t o be
carried with Contractor's wiring and fixing material. The
wo r k shall b e carried a s p e r t h e instructions o f site
engineer.
39 39 Supply of de-onnizer plant (Aqua Ion model No ACAMB Numbers 1.00 49880.10 49880.10
4 Bed type)
40 40 Supply of Electronic interlocking system excluding Panel Set 1.00 10500000.00 10500000.00
Processor (Hot Standby) for ( Badanahallu) station with
Signaling functions up to 125 units as per Function
table enclosed along with 15% spares, tools, manuals
and Instruments. El to be provided as per RDSO Spec
No.RDSO/SPN/192/2005 or latest. This includes supply
of 55" Maintenance VDU and Maintenance
PC(embedded PC) and all types of indoor relays along
with point contactor relays(QBCA1) required for
points/other indoor purposes.(ref Technical
specificatons /explanatory note in the tender document)
41 41 Incremental rate for signaling functions in El SYSTEM Per Unit 22.00 90000.00 1980000.00
over and above 125 functions under item 1 above.(per
unit = per function)
42 42 Designing of EI application logic and interface circuit as Lumpsum 1.00 600000.00 600000.00
per the SIP & Table of Control supplied by railway for
t h e a b o v e mentioned stations,This includes internal
FAT testing prior to submission for approval of circuits.
43 43 Installation, wiring, testing and commissioning of EI Numbers 1.00 600000.00 600000.00
equipments supplied for the stations, duly carrying out
the required FAT & SAT, including transportation from
consignee depot to site at station T his a lso includes
supply of racks,trays etc,with all the accessories,
trenching, laying & splicing o f 2 4 C OFC supplied by
railways for communication equipments of EI.
44 44 Supply and Installation of Operator VDU. The operator Set 1.00 950000.00 950000.00
VDU consists of industrial grade embedded fanless PC
with 55 inch monitor (2 No.s) . The monitor should be
capable of working on 110 V AC. The embedded PCs
f o r Operator VDU should b e as per RDSO TAN No.
STS/E/TAN/3007 Version 1 . 0 o r latest wit h adequate
storage memory to work in hot-standby mode. The
VDUs should be provided with all necessary software to
work along with EI equipment. Necessary mounting
arrangements also should be provided for operator
VDU.
45 45 Supply, Installation, wiring, testing and commissioning Numbers 1.00 600000.00 600000.00
of Datalogger as per RDSO IRS/99/2006 or latest with
EI interface card (Digital interface cards), for 512 digital
i n p u t s a n d 3 2 a n a l o g i n p u t s . T h i s includes
validation,yard stmiulation ,fault logic configration at
Station & Central and supply of all miscellaneous items
and software for commissioning of datalogger with
networking.( including supply of PC,software,printer,0.6
KVA UPS,mounting table and revolving chair of reputed
firm make as per details in Technical specification).
Data Loggerwith for remote monitoring with net
workfacility of signalling parameters and power supply
arrangements with 64 input digital cord as a spare and
fuse monitoringPCBs for monitoring at least 50 No. of
2Amps Fuses, with inbuilt modem cards for networking.
46 46 Supply of 25x3 mm Cu tape for BRC (Bonding ring Metre 50.00 550.00 27500.00
Conductor).
47 47 Laying of 50x6 mm GI tape for interconnection of earth Metre 40.00 150.00 6000.00
electrodes. (T his includes excavating of trench t o a
suitable depth a s per site requirement and refilling of
same after laying the GI tape as per site requirement).
48 48 Provision 35 sq mm single core CU cable for connecting Metre 200.00 150.00 30000.00
main earth electrode to equipment room (routing
through the GI Pipe/DWC/HDPE/PVC Conduit pipe of
suitable size as per site requirement.
49 49 Provision of 25x3sq m m Cu tape for BRC on walls with Metre 50.00 275.00 13750.00
s u i t a b l e i n s u l a t e d stand-off in s i d e Relay
Room/Equipment room as per site requirement.
78 78 Fencing for location box duly providing foundation (a pit Set 10.00 7440.50 74405.00
of size 400mm x 400mm x 400mm is to be dig and
cement concrete foundation in the pit in the ratio 1:3:6
to be casted) and fixing the frames/doors and E- type
lock to the fencing with supplied material. The rail
post/angular is to be erected up right in the foundation.
All materials are to be arranged and used by the
contractor (Rail post / angular / frames /Fencing/ E type
locks will be supplied by railway). Cutting of rail post /
angular / fencing to the required length, transportation
to the site is to be done by the contractor.
79 79 Supply and provision of MS Cable Tray of thickness 1.6 RMT 8.00 5922.00 47376.00
mm, including top cover for closing, with all required
miscellenous materials for installation. Installation to be
carried out as per the instructions of site engineer. MS
Cable Tray including Cover should be powder coated
with Siemens Gray Color. -MS Cable Tray - 400 * 300
80 80 Supply and provision of MS Cable Tray of thickness 1.6 RMT 8.00 4928.00 39424.00
mm, including top cover for closing, with all required
miscellenous materials for installation. Installation to be
carried out as per the instructions of site engineer. MS
Cable Tray including Cover should be powder coated
with Siemens Gray Color. -MS Cable Tray - 400 * 150
81 81 Supply and provision of MS Cable Tray of thickness 1.6 RMT 8.00 3760.00 30080.00
mm, including top cover for closing, with all required
miscellenous materials for installation. Installation to be
carried out as per the instructions of site engineer. MS
Cable Tray including Cover should be powder coated
with Siemens Grey Color. -MS Cable Tray -250 * 100
82 82 Supply and provision of MS Cable Tray of thickness 1.6 RMT 8.00 2676.00 21408.00
mm, including top cover for closing, with all required
miscellenous materials for installation. Installation to be
carried out as per the instructions of site engineer. MS
Cable Tray including Cover should be powder coated
with Siemens Grey Color. -MS Cable Tray -100 * 100
83 83 Supply of L- angles 75 *10mm a s per required lengths Per Unit 1.00 86966.00 86966.00
f o r various boards like Goods warning/calling on/Axle
counter etc. (UNIT: PER TON).
84 84 Excavation of cross trench to a depth of 1M or as per RMT 100.00 175.50 17550.00
site requirement, for identifying the existing cable path
without damaging the working cables.
85 85 Supply of Office table of Godrej T9 or reputed firm for Numbers 2.00 20100.00 40200.00
keeping circuits/carrying office work.
86 86 Supply of Office table of Godrej T8 or reputed firm for Numbers 2.00 10720.00 21440.00
keeping circuits/carrying office work.
87 87 Supply of Office/executive/computer support Revolving Numbers 2.00 9380.00 18760.00
Chairs (Bravo high back and Cushioned) of Godrej or
reputed firm for seating arrangement .Godrej Interio
Fabric Bravo High Back Chair, Size: 38-43 H X 30 W X
30 D
88 88 Supply of Office/visitor/study/executive/computer Numbers 3.00 5360.00 16080.00
support Chairs (Cushioned) of Godrej or reputed firm
for seating arrangement.
89 89 Supply, fabrication, installation and fixing of panel Numbers 1.00 389212.40 389212.40
operator console in SM room to accommodate 2 VDU s,
SM key box , counter box, BPAC reset etc. The basic
frame structure of the console to be made of MS/Teak
wood and water proof plywood sheet of 30 mm
thickness of reputed make to be used for fabrication of
table duly consisting of required partitions
/compartments for accomodating associated required
equipments/terminals. Interior and exterior to be
covered using lamination/MS sheet of reputed make
and approved colours and drawing as per the
instruction of site engineer. All the materials required for
the fabrication and fixing o f console t o be supplied by
contractor including lead, lift and manpower a s per the
instruction o f s i t e engineer. T h i s i t e m also includes
supply of godrej C13 or better make /model computer
table (1No.) for installation of maintenance VDU and
godrej office executive chair or better make (2No.)As
per the PCSTE/SWR/UBL approved Daigram.
90 90 Supply of Key Lock Relay (KLCR) working o n 24V DC Numbers 2.00 15023.00 30046.00
ACI Type T M A with different ward combination IRS-S-
46, IRS-S@ 45"44@ IRS-S23 with contact configuration
4 F - 4 B ( T M A 1 1 4 4 / 1 1 6 IM-OLD) Accepted Make-
INTEGRA or similar. (Two extra ward plates for point
machines to be supplied with each relay).Ward
combinations shall be decided by the Railway Engineer
at site.
91 91 Tool kit for ESM as recommended in CSTE technical Set 1.00 40200.00 40200.00
instructions and as per technical specn.
92 92 Navtal locks godrej make 75mm with 2 keys with Numbers 8.00 670.00 5360.00
Engraved key chian as per instrucation of Site
Enginner.
93 93 Digging of cable trench to a depth of not less than 30cm RMT 200.00 211.00 42200.00
in rocky terrain, concreting the trench with 150mm x
150mm thick concrete in the ratio 1:2:4 and after proper
curing, back filling with excavated soil.
94 94 Supply of Lightining and surge arrester of class B and C Numbers 1.00 26393.00 26393.00
suitable for single phase supply i n TT network as per
RDSO spec.no.RDSO/spn/1665/2004 amdt .5 or latest
& as recommended by RDSO vide letter
no.STS/S/IPS/Genl. Dated27.01.2006.
95 95 Installation a n d commissioning of class B and C Numbers 1.00 6598.00 6598.00
arrestors as supplied. These din rail mountable devices
along with 63 amps HRC input fuse and fuse base shall
b e f i x e d i n a w a l l m o u n t a b le c a b i n e t o f size
450x250x150 mm made as MS steel of 20 gauge or
better with IP31 protection and power coating.All the
internal power wiring shall be made by using 10sq.mm
cu cable.the PF contract of the class C arrestor shall
also be wired using cable thickness of 2,5 sq.mm and
terminated on a suitable terminal block.
96 96 Universal Fail Safe Block Interface (UFSBI) complete Pair 1.00 1114357.86 1114357.86
and Block panel for Single line operation as per RDSO
Spec. No. IRS:S-105/2012 or latest
97 97 Automatic Media changeover of modems working on Pair 3.00 33617.92 100853.76
redundant channels for data transmission on
OFC/Quad
98 98 MODEM compatable with existing UFSBI system (for Pair 3.00 56841.72 170525.16
use with secondary/backup media i.e 4-wire OFC VF
Channel form station Primary mux or UFSBI E1
modem)
99 99 Supply of CPU card suitable to work with UFSBI (as per Numbers 1.00 30619.53 30619.53
IRS:S-104/2012)
100 100 Supply of CCC card suitable to work with UFSBI (as per Numbers 1.00 25867.36 25867.36
IRS:S-104/2012)
101 101 Supply of Hot-Standby DC-DC Converter type Power Numbers 1.00 47277.34 47277.34
Supply to work with UFSBI (as per IRS:S-104/2012)
102 102 Installation, testing and commissioning of UFSBI Per Unit 2.00 75280.12 150560.24
complete and Block panel for Single line/Double line
operation as per RDSO Spec. No. IRS:S-105/2012. [All
misc items required for commissioning shall be supplied
by contractor] (Per Unit=Set Per Block Section)
103 103 Installation, testing and commissioning of Automatic Per Unit 2.00 22443.39 44886.78
Media changeover modems working on redundant
channels for data transmission on OFC/Quad. This
included installation & configuration of Industrial grade
modem, wraping of E1 connections etc. (Per Unit=Set
Per Block Section)
104 104 Multi Section Digital Axle Counter(MSDAC): Supply, Per DPR 20.00 375801.00 7516020.00
design, installation, testing and commissioning of Multi
Section Digital Axle Counter (MSDAC) complete system
as per RDSO Specification No. RDSO/SPN/176/2013
version.3 with latest amendments STR No. SIQ 0001
Ver.2.0 or latest. Tentative signal and Interlocked Plan
of Badanahalu is enclosed in Technical Specifications..
MSDAC Reset procedure shall be as per SWR MSDAC
Reset policy. Tenderer shall design the scheme for
provision of required number of evaluators, reset
equipment's, trackside junction boxes, detection points
and track clearance relays etc and shall be submitted
along with the offer. Length of the cable required for
each DP and Rail Type will specified at the time of
issuing call Letter. [This schedule also includes supply
of 10% all types of cards, LV Boxes, Wheel sensors and
other essential modules as specified in RDSO Spec, it
shall be rounded to nearest integer subjected minimum
of one item. For calculating the 10% spares, total
quantities of schedule DPs to be considered. It shall
contain 16 DPs and 14 Track Sections. Suitable for
commissioning of yard replacement as per SIP (copy
enclosed).Hardware requried for 20 DPs. Inculdeing
supply and installation of maintiance free earth.
Tenderer shall design the scheme for provision of
required number of evaluators, trackside junction
boxes, detection points and track clearance relays etc
to be submitted along with the offer. MSDAC should
have facility to reset track sections. System shall be with
cooperative type design and the total cost breakup shall
be given against the Tender for OEM components
along with the offer or before issue of LOA and all the
cables of required lengh,accessories should be
supplied as per site requirement. [This schedule also
includes supply of 10% all types of cards, LV Boxes,
Wheel sensors and other essential modules as
specified in RDSO Spec, it shall be rounded to nearest
integer subjected minimum of one item. One set of
Specialized Tool and Measuring equipment's as per
RDSO specifications shall be supplied. Signaling
Plans(SIPs) of Badanahal may be collected from office
of Dy.CPM/GS/UBL. For any clarifications with regard to
drawings/ technical details please contact
Dy.CPM/GS/UBL
105 105 Supply of Diagnostic system for Remote diagnostics Numbers 1.00 350000.00 350000.00
106 106 Tool set for wheel sensor mounting and maintenance of Numbers 1.00 105000.00 105000.00
MSDAC consisting of torque wrench, ratchet, testing
plate, measuring tape, screw driver, and gloves and
multi meter fluke 115
107 107 Supply of Electric Point Machine - IRS type 220 mm Numbers 5.00 120360.00 601800.00
throw, High thrust (AC Immunity 160V AC) Non trailable
to operate on 110V DC complete with Lock and
detector, Slides, Cable termination box, Telescopic
pipes point insulation set, Ground connection set,
Clamp point lock 60 kg, TWS for B.G, Tools and
complete accessories as per Drg. No. RDSO/S-11000
and RDSO/S-3454, ALT-A, RDSO/S-3395 and all as per
RDSO Specn. IRS : S-24/2002 with amendment 01 or
latest.
108 108 Supply of Nylon insulations for Crompton/high Set 10.00 710.08 7100.80
thrust/TWS for 220mm Point Machine, consists of a)
Insulating washer Drg. No. S-8640: 12 Nos b) Insulating
washer Drg. No. S-8640/1: 04 Nos. c) Insulating washer
Drg. No. S-8640/2: 02 Nos. d) Insulating bush. Drg. No.
S-23199: 12 Nos e) Insulating bush. Drg. No. S-3463:
01 No. f) Insulating bush. Drg. No. 22179: 02 Nos. g)
Insulating bush. Drg. No. S-8912: 02 Nos. h) Insulating
plate. Drg. No. S-3404 02 Nos i) Insulating bush. Drg.
No. S-8813: 04 Nos.
109 109 Supply, Installation, testing and commissioning of SMPS Set 1.00 1550000.00 1550000.00
based Integrated Power Supply (IPS) upto 4 Lines in
RE area confirming to RDSO Specification No.
RDSO/SPN/ 165/2012 (Ver. 3.0) with latest amendment
with STR No:- SIQ 0110 Ver. 3.0 or latest along with
status monitoring panel as per Drawing
No.B/SG/Proj/BNC/ IPS /PI-4L/RE/01 of dated 06-10-
2021 enclosed as Annexure A and B. IPS should be
supplied with (55+5@61<41@ Nos. of charged
Secondary Cells 2V-300AH as one set for one IPS Lead
Acid Stationary Secondry Cells For S&T Installations
along with 16 Sqmm cable for each IPS set is (50 Mtrs
Red + 50 Mtrs Black + 50 Mtrs Green) = 150 Mtrs.
SPECIAL CONDITIONS:- 1. (The supplier shall take up
installation , wiring, testing and commission with
minimum one month prior notice period from Railways.
2.All the required cables/ Miscellaneous items for
commissioning shall be supplied as part of this tender.
3.Supply, installation, testing and commissioning of
SPDs (class B&C) are covered in scope of this tender,
Supply items shall be inspected by RDSO.)
110 110 Transportation errection and wireing of IPS to the Set 1.00 64000.00 64000.00
power distrubation panel This includes transportation of
IPS and IPS Batteries from UBL Stores to the site
,Erection of IPS Panel on teak Wood Planks inter
connection between panel and wireing the IPS to power
distrubation panel and wireing the IPS TO POWER
DISTRUBATION PANEL USING 10 Sq mm multi strand
copper cables.The wireing should be done neatly
using(This includes supply and installtion of Aluminium
ladder with phenlic sheet of thickness 6mm ,Teak wood
plank width of 150mm and thickness 25mm 10 sq mm
multi strands will be supplied by contracter)
111 111 Supply o f tools kit comprising o f the followinq tools: 1, Set 1.00 58696.74 58696.74
Kronne insertion t o o l - 5 N o s . 2 . Digital multimeter
(Rishabh) - 1 No. 3. Electronic insulation tester 100
volts dual range Model No lT/100/ll orequivalent - 1 No,
4. Blow torch working on LPG with following accessories
(a)Universal Handle - 1 No (b)Burner - 8 No (c)Neck
Tubes -2 No (d)Gas hose pipe - 2 Mtrs (e)Spanner - 1
N o (f)SwivetTypeRegulatingValve 1 N o . (g)Branded
Cylinder of 2Kg. Capacity 2Nos 5. Screw driver set -
Taparia make - 1 No, 6. Double ended spanner set of
12 Nos-Taparia make- 1 set, 7. Cutting Piler - 6" -
Taparia make - 2 Nos. B. Nose Plier - 6" - Taparia
make - 2 Nos 9. Wire stripper - 2 Nos. 10. Cable
joinlerq Collapsible toot kit CompiEing the foilowing (a)
Hacksaw frame - 1No. (b)Hacksaw Blade - 5 No. (c)Hot
chisel 12 inches - 1 No (d)Adjustable Spanner 2inches
jaw - 1 No (e)Scissors 15 inches - 1 No (f)Din Cutter 15
inches - 1 No (g)Ball pean Hammer 1 1/2 tbs - 1 No
(h)File Flat 5 inches - 1 No (i)Triangular File smooth - 1
No 0)Steeltape 3M - 1 No (k)Steel tape 30M - 1 No
(l)Soldering iron soldron S0watts - 1 No (m)Knife 8
inches - 1 No (n) Knife 12 inches - 1 No
112 112 Manufacture and Supply of Power Distribution Panel for Numbers 1.00 57635.92 57635.92
IPS using Hylem sheet 10 mm as per site requirement
and erecting it using MS angle clamp 65mm X 65mm X
8mm, HRC fuse block, Mains control switch, ammeter
by-pass switch, voltmeter, ammeter, PBT terminals
60mm and wiring the same using wire PVC 7/1.40mm
as per approved power diagram. This also includes
termination of power cables using teakwood clamp of
size 25mm X 60mm X 150mm on a base plank of
25mm thick 150mm width. (MS angles 65mm X 65mm
X 8mm, Hylem sheet of 10 mm Thickness, as per site
requirement, bolt and nuts required for manufacture of
power panel, HRC fuses, box and carriers, teak wood
clamp, wire 7/1.40mm, PVC casing and capping and all
other miscellenous materials will be supplied by the
contractor, Supply of PBT terminals 60mm is not
included in the schedule.)
113 113 Supply and Provision of Power Supply Change over Numbers 1.00 68838.84 68838.84
arrangement at SM room. CLS panel of size
800x500x275mm powerd coated of MS sheet thickness
1.6mm as per RDSO specification No
TI/SPC/PSI/CLC/0020 .
114 114 Supply of Double Walled corrugated pipe-103.5mm Metre 100.00 407.96 40796.00
inner dia & 120mm outer dia conforming to specification
No. IS 14930(Part 2): 2001 with one coupler for every
6m of pipe as specified in Vol.II of the Tender
document.
115 115 Supply of Relay Non-AC immune, plug in type style Numbers 120.00 3127.00 375240.00
QN1, DC neutral line, 24V,8F,8B contacts, front and
back contacts metal to carbon with plug board retaining
clip and connectors confirming to BRS 930, IRS-S34,
IRSS23 (as applicable). The interlocking code for this
unit shall be ABCDF (with ATC clips). A
116 116 Supply of AC immune plug in type style QNA1 DC Numbers 50.00 3658.00 182900.00
Neutrel line 24 V 8F/8 B contacts front and back
contacts metal to carbon with plug board ,retaining clip
and connectors to BRS :931A,IRS:S@ 58<44@
IRS:S:34 & IRS:S:23 (as applicable) the interlocking
code for this shall be ABDGH
117 117 Supply of Relay, Plug-in Type, QL1, magnetically Numbers 10.00 4217.32 42173.20
latched, neutral line, 24 VDC, 11F.4B contacts and back
contacts, Metal to Carbon with Plug board, retaining
clips and connectors conforming to BRS 935/A, IRS S@
45"44@ IRS S23 as applicable. The interlocking code
for this unit shall be ABDEG
118 118 Supply of Relay AC immunized, plug in type, style Numbers 45.00 4925.90 221665.50
QNA1K, DC neutral line, 24V1000 ohms, 6F.6B
contacts, front contacts metal to carbon and back
contacts metal to metal / carbon, complete with
plugboard, retaining clip and connectors conforming to
BRS 931A, IRS IRS.S60;IRS.S34; IRS.S23 and RDSO
specification STS/E/Relays/UEA (PI), dated 30-6-
97(Annexure - II) (as applicable). The interlocking code
for this unit shall beCDEKY.(with ATC clips).
119 119 Supply of Relay Plug in type AC LED all aspects AC Numbers 50.00 4560.70 228035.00
lamp proving relay unit with inbuilt current transformer
type slow to release neutral line Relay with 4F/4B
contacts metal to carbon, shall be suitable for working
with 110V AC LED signal lamp proving rates at 15W
conforming to RDSO spec. no. STS/ E/ Relay/ AC lit
LED Signal/09- 2002, Amendment- 1, BRS 941A,
IRS:S-34 and IRS:S-23 (as applicable). The interlocking
code for this unit shall be ABDHK.
120 120 Supply of LED signal lighting Unit with built in current Numbers 12.00 8968.00 107616.00
regulator, retrofittable in existing CLS units as per
RDSO specification RDSO/SPN/199/2010 or latest.
Main Signal aspect Red
121 121 Supply of LED signal lighting Unit retrofittable in existing Numbers 12.00 8732.00 104784.00
CLS units as per RDSO specification RDSO/SPN/
199/2010 Rev 1.0 with latest amendments for Yellow
Aspect- Main signal
122 122 Supply of Main LED signal lighting Unit working on 110V Numbers 11.00 10620.00 116820.00
AC as per RDSO specification RDSO/SPN/ I99/2010 rev
1 .0 retofittable in existing CLS housing
(SA23002S2324/M) Green Aspect RDSO specification
RDSO/SPN/I99/2010 rev 1.1;
123 123 Supply of LED Signal lighting unit for route indicator ( Numbers 12.00 5640.40 67684.80
110V AC LED signal) As per RDSO/SPN153/2011 (REV
4.1)
124 124 Supply of LED signal lighting unit 110V AC for Calling Numbers 12.00 6932.50 83190.00
on signal in Railway signaling as per
RDSO/SPN/153/2011 (REV. 4.1)
125 125 Supply of SHUNT LED Signal lighting unit working on Numbers 16.00 5681.70 90907.20
110V AC As Per RDSO Specn. No.
RDSO/SPN/153/2011 (REV.4.1) Retrofittable in existing
CLS Housing
126 126 Supply of Permanently Lubricated High Density Kilometre 4.00 102471.90 409887.60
Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along
with End Cap, End Plug, Cable Sealing Plug and
Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 (upto
Amdt.2) or latest
127 127 Laying of PLB HDPE duct, 40/33 mm Dia, in the Kilometre 6.00 13000.00 78000.00
trenches and in the protective works already provided
including in HDD portion and supply pulling of Nylone
rope through it at different places as per direction of
engineering charge or site engineer.
Total 40080812.23
Schedule Schedule TC-Telecom (Non SOR)
Item- 03 Supply and Execution
S No. Item Description of Item Unit Qty Rate Amount
No
1 1 Supply, Installation and Commissioning of 3 KVA Online Numbers 1.00 134890.70 134890.70
UPS with 2 Hrs SMF BatteryBackup. This also includes
supply of one set MF battery of suitable AH capacity
Rack and one set compatible MCBs complete with
cover & fixing materials, one earth leakage circuit
breaker arrangement [Detailed Specification in
Technical Document]
2 2 Supply of Telecom Termination panel with Numbers 1.00 52718.30 52718.30
WAGO/Pheonix/Elmex make or similar disconnecting
Terminals blocks o f size 1500mm x 500mm x 200mm
t h i c k n e s s 1 . 6 m m (16 SWG) 150 numbers of
disconnecting terminal block with accessories. (The box
should be divided in to two compartments 500 m m from
T O P w i t h door arrangement including locking, and
b o t t o m 1000mm closed fully with screws
WAGO/Pheonix/Elmex terminals suitable f o r cable
dimensions maximum o f 2.5 sq.mm. Provision of easy
and ensuring aesthetics.
3 3 Supply of 20 pair CT box with Disconnecting erminals of Numbers 20.00 4766.75 95335.00
Wago/Pheonix/Elmex make or similar
4 4 Supply of 10 pair C T box with Disconnecting terminals Numbers 4.00 3095.80 12383.20
of Wago/Pheonix/Elmex make or similar
5 5 Supply o f Joint k i t conforming t o RDSO specificaiton Numbers 10.00 4474.65 44746.50
No.IRS-TC 77/2006 Revision1 or latest for quad cable
6 6 Fixing of 'Telecom Termination Panel' and termination Numbers 1.00 5876.50 5876.50
of cables o n Wago/krone connectors a s p e r the
instructions of the site Engineer.
7 7 Fixing of 20 pair CT box with disconnecting terminals of Numbers 4.00 3527.05 14108.20
wago/phonix/elmex make o r similar and termination of
cable at the station/LC gates etc. This includes fixing of
Quad/PIJF cables and CT box on the wall.
8 8 Fixing of 10 pair CT box with disconnecting terminals of Numbers 4.00 3078.55 12314.20
wago/phonix/elmex make o r similar and termination of
cable at the station/LC gates etc. This includes fixing of
Quad/PIJF cables and CT box on the wall.
9 9 Provision o f n o r m a l j o i n t o f H e a t Shrinkable type Numbers 5.00 4085.95 20429.75
complete for 6 quad cable. After the jointing the through
cable has to be tested for insulation resistance and loop
resistance in presents of Railway Engineer and in case
of any defects the jointing has to be done at free of cost
b y t h e contr actor . [ H e a t Sh r in ka b le j o i n t i n g kit
conforming t o RDSO specificaiton No.IRS-TC 77/2006
covered i n the supply portion h a s t o b e used f o r this
purpose.] The Contractor should supply all other small
items free of cost which are required for making a joint.
Only gas blower to be used for blowing
10 10 Supply of Online UPS of 1 KVA capacity input voltage Numbers 1.00 29000.00 29000.00
160V AC - 280 V AC, output voltage 230V AC,
Operating Freq 47-63 Hz with back up time 120 min
(APC or Emerson)
11 11 Excavation of jointing pit without damaging the fiber and Numbers 2.00 6500.00 13000.00
provision of joint chamber of 1.2 mtr dia , 60 Cm height
a n d 5 0 m m thickness wit h t w o piece t o p cover and
bottom cover with holes for drainage and cable entry (
T h e reinforcement drawing enclosed ) . T h is includes
backfilling and ramming o f the trench after placing the
joint closure a n d cable lo o p i n t h e chamber without
causing any damage to the same and consolidation of
so il a s we ll a s disposal o f so il a s p e r p l a n a n d as
advised by RailTel Representative.
12 12 Supply, transport and filling of the RCC joint chambers Numbers 2.00 1000.00 2000.00
w i t h d r y s a n d m i x e d w i t h anti-termite chem ical as
required i n specification u p t o 400mm height a n d the
cover is refixed in position.
21 21 Supply of Programmable Primary Digital drop insert Numbers 1.00 180000.00 180000.00
Multiplexer complete with all accessories as per RDSO
Specification IRS: TC: 68/20 12,Rev.0 (Amdt. No. -1),
including Connectors and cables required for
installation including 100 Pair Krone type MDF. Each
channel card shall have minimum four channels per
card. The single sub rack shall be capable of being
equipped up to min. 60 Channels without additional
power supply unit.The MUX shall be wired & equipped
for 30 channels, with following circuits:- 20 Nos of VF
2W/4W E&M Circuits; 4 Nos of 2 Wire FXO/Exchange
Interface Circuits; 6 Nos. of 2W Subscriber/Hotline
circuits along with ringer cards. Make/ BrandWEBFIL
LTD/KOLKATA
22 22 Wiring of SDH ADMs, PDMUX with accessories, surge Numbers 1.00 40000.00 40000.00
protection arrangement, FDF, racks, DDF, runway
ladder etc. this includes connecting all pig tails and
optical patch cards etc. to SDH and primary mux
equipment with all interface cards to 48V bus including
supply of wires and connectors, terminations of all E1s
on DDF, termination of VF interface circuits to krone
type MDF at both ends including taking PVC cable over
runway or a wall, krone type DP with all surge and
lighting protection complete for all the circuits derived
from PD mux. This work includes wiring and connection
of telephones in SM's room and extension of generator
supply equipment. All miscellaneous materials like
power wires conduit and accessories etc. shall be
supplied by the contractor. Suitable link panel should be
provided on this rack for testing and isolation of fault.
23 23 Supply and installation of SMPS charger 230V AC 50Hz Numbers 1.00 154400.00 154400.00
input and 48V DC/25 Amps output in (2+1
configuration) suitable for VRLA battery as per RDSO
specs: RDSO/SPN/TL/23/99 ver.4
24 24 Supply and installation of 48V,200AH VRLA battery Numbers 1.00 144750.00 144750.00
bank as per specification No.IRS-S-93/96A[One set
battery bank contains 24 nos of 2v/200AHcells].
25 25 Supply and installation of 19"- 42U Rack complete with Numbers 2.00 47720.98 95441.96
fittings for housing LER,LSR,SDH equipment, FDMS,
DDF and other equipment like cable managers,
completely wired using krone module and other
equipment's like runaway ladders etc., as per technical
specification below. It should be able to lock all the
equipment with only order wire telephone outside the
rack , the rack should of APW President/ Rittal make
etc., The components of the rack are specified below.
this includes transportation and installation of rack in
prefab/building at specified stations. a. Rack S33 42U
600WX600D -1 no. b.fixed side panels 42U x 600 D -
2nos. c.Front glass door plain 42U/600W -1 no. d. Rear
MS door plain 42 U/600W-1 no. e. Caster with brakes-
2nos. f.Fans directly mounted on the top 48v Dc
90CFM - 2NOS. g.Krone mounting bracket -01 No. h.
MCB mounting panel with MCBS a)32 Amps MCBs (DP)
- 2 nos. b) 6 Amps MCBs (DP) -6 nos. i) earth continuity
kit -o1 nos j. Equipment trays-5 nos. k. channel with
cable loops 42U-2 Nos.
26 26 Supply ,installation, termination and testing of Rack/Wall Numbers 2.00 27135.00 54270.00
mountable FDMS and termination IN and OUT 24 fiber
OFC cables (with all connecting materials)
routing/dressing fiber as per direction of
engineer/InCharge. this work includes
termination/splicing of fibers and testing of fibers in the
section/block and report of fiber to be submitted in hard
and soft copy.
27 27 Supply and Installation Testing and Commissioning of Numbers 1.00 36000.00 36000.00
Isolated DC-AC Inverter 1+1HA input 48 V DC,
Output:220V AC 1000VA or higher, with all required
Protection Circuits.
28 28 Supply of OFC Pigtail patch cord, Single Mode, 5 mtr or Numbers 8.00 1058.76 8470.08
10 mtr as per RDSO/SPN/TC/69/2007, Rev.0 or latest
29 29 Supply of RJ 45 connector suitable for STP/UTP cable. Numbers 100.00 3.00 300.00
30 30 Supply of CAT 6 UTP Patch Cord-2 meters length. Numbers 10.00 90.00 900.00
31 31 Supply of CAT-6 Patch Cord-5mtrs length. Numbers 10.00 400.00 4000.00
32 32 Supply and Termination of 12 Fiber 12 SC Type Rack Numbers 2.00 7700.00 15400.00
Mountable FDMS loaded with SC '0' DB & Adaptor SC
SM Pigtail 1.5 meters with all the accessories required
for installation.
33 33 Supply and Fixing o f PVC Trunking o f 50X50mm with Metre 50.00 580.00 29000.00
c o v e r o f 2 m m thick and 2mtr length each. (This
includes all materials like clamps, bends, couplers,
fixing required forlaying).
34 34 Supply and Installation of Standard 19- inch Rack Numbers 1.00 253000.00 253000.00
Mountable Layer 3, 24 Port Managed Switch with 24
Nos of 10/100/1000 Ethernet Ports with POE + Support
and Redundant AC Power Supply, Dedicated Stacking
Module 4 x 10 GE SFP+ Ports for uplink including 4 Nos
of 10 GE BX SM SFP+ Modules, as per para number
4.0 of RDSO SPECIFICATION
NO.RDSO/SPN/TC/83/2020 Rev 2.1 or latest. Mounting
Kit with all necessary accessories to be supplied as per
specification.
35 35 Supply, Installation and Commissioning for 4 Port Numbers 1.00 18000.00 18000.00
Gateway to support 4 Port Concurrent Emergency
Communication at HQ/Way station to support 4 wire
ports/ 4 Port Gateway with built in 2 wires to 4 wire
Hybrid convertor to support 4 wire output as Per Clause
13 of RDSO/SPN/TC/99/2023 Ver. 3.0 or latest as per
specification
36 36 Supply and Installation of Station License of TCCS Numbers 2.00 17000.00 34000.00
Communication Server of 1+2 Configuration as per
RDSO/SPN/TC/99/2023 Ver. 3.0 or latest.
37 37 Supply and Installation of Port License of TCCS Numbers 2.00 2500.00 5000.00
Communication Server in 1+2Configuration as per
RDSO/SPN/TC/99/2023 Ver. 3.0 or latest.
38 38 Wiring and Termination for IP Phones up to last point Numbers 1.00 46000.00 46000.00
(includes supply,installation, configuring, fixing of I/O
box, Drawing of UTP/OF Cable, Fixing of PVC Pipe
/Casing capping. All materials cable,box,pipes items
required for connection to be supplied by Contractor as
per site requirement)
39 39 Supply and Installation of Control IP Telephones with Numbers 1.00 22000.00 22000.00
Hands Free and Gooseneck Operation for Way Side
Station as Per Clause 11 of RDSO/SPN/TC/99/2023
Ver. 3.0 or latest as per specification.
40 40 Supply and installation of SIP Based Basic IP Phone Numbers 1.00 5100.00 5100.00
with 128x64 Pixel Graphical LCD as per Specification.
41 41 Supply of universal DTMF way station control telephone Numbers 1.00 7504.00 7504.00
conforming to spec., No.IRS.TC-82/2005 or latest
42 42 Supply of power supply unit for universal DTMF way Numbers 1.00 6030.00 6030.00
station control phone conforming to spec.No.IRS:TC-
72/97 Amdt. 1 or latest with 12V/7AH MF battery.
43 43 Supply of light weight portable control telephone Numbers 2.00 5628.00 11256.00
(4Wire/2Wire) as per RDSO specification IRS: TC-
78/2020 Ver. 1.1 or latest.
44 44 Supply of Caller Id phone similar to Binatone Concept Numbers 5.00 870.00 4350.00
700 or better.
45 45 Supply of station telephone (master telephone) for Numbers 5.00 52000.00 260000.00
electronic LC gate telephone system as per RDSO
specification IRS TC RDSO SPN TC/51/2021 Rev 1.0 or
latest.
46 46 Supply of electronic LC gate telephone (slave Numbers 5.00 5200.00 26000.00
telephone) for Electronic LC Gate System as per RDSO
Specification No.RDSO/SPN/TC/51/2021 Ver. 1.0 or
latest
47 47 Supply of Centralized power supply system 24V DC Numbers 5.00 7000.00 35000.00
power pack with 7AH MF battery for electronic LC gate
Telephone as per RDSO specification No
RDSO/SPN/TC/51/2021 Ver. 1.0 or latest
48 48 Supply of 100 pair krone box with modules & mount Numbers 2.00 5360.00 10720.00
assembly wall mounting type powder coated with surge
and lighting arrester and locking facility.
49 49 Installation testing and commissioning 0f 100/50/20 pair Numbers 2.00 804.00 1608.00
Kronection box ,fitting the same wall as directed by
Railway Representative
50 50 Supply of switch board cable 3 pair annealed tinned Metre 100.00 15.00 1500.00
copper conductor PVC insulated of size 0.51mm dia.
51 51 Supply of 10 pair switch board telephone cable 0.5mm Metre 100.00 74.00 7400.00
dia, annealed copper conductor PVC insulates as per
IPS TC-24/91
52 52 Supply of Emergency Socket boxes of FRP make Numbers 10.00 5500.00 55000.00
conforming to specification RDSO/SPN/TC/44/2002 Ver.
3.0 or latest.
53 53 Supply of 6 pin socket flat as per RDSO Spec. No. Numbers 10.00 871.00 8710.00
IRS/TC/42/20 Ver. 1.0 with latest
54 54 Provision of emergency communication along the Numbers 2.00 6432.00 12864.00
railway track. Fabrication of emergency post as per
drawing No. UBL/SG/CON/6/2004 and fixing of
emergency socket post and burying the post to a depth
of 1m after entry of cable. The post to be painted with
red oxide before installation. This includes termination
of derivation cables on termination strip inside the
emergency socket, painting of emergency socket post
with alternate black and white strips of 6'' width. The
paint used should be of standard quality and two coats
of aints should be applied. The EMC post should be
painted with red oxide base before painting. (rails will
be supplied by railways for the fabrication of emergency
post)
55 55 Blowing/Drawing of OFC 24F/12F/6F Power Cable and Metre 2000.00 7.71 15420.00
CAT Cable (including crimping) through PVC Conduit
already installed.[Detailed Specification in Technical
Document].
56 56 Drawing of Switch Board/Power cable through PVC Metre 100.00 15.00 1500.00
pipe/Casing capping fixed on the walls ,as directed by
site InCharge. This work includes termination of cables
in the krone connector and fixing of IPM and extending
earthing to krone box.
57 57 Description:- Supply of 2T VF transformer 470:1120 Numbers 4.00 2412.00 9648.00
ohms impedance conforming to Spec. IRS-TC-76/2000.
58 58 Supply of 2T VF transformer 470:600 ohms impedance Numbers 10.00 913.06 9130.60
conforming to Spec. IRS/TC- 76/2021 or latest.
59 59 Supply of transceiver VHF module 25 Watts Numbers 1.00 15000.00 15000.00
synthesized configuration VM-04 of bandwidth 136-174
MHz with DTMF microphone, of Motorola make model
GM338/XiRM- 3688 or kenwood TK7360 as per
specification enclosed.
60 60 Installation, testing and commissioning of 25 Watt VHF Numbers 1.00 7423.00 7423.00
set with GP antenna and antenna cable of length 30 M,
power supply and battery of 12V 65AH. This includes
supply and fixing of GI pipe of suitable dia to the
required hight as per the guidance of the field engineer,
wiring of antenna cable through PVC conduit. All the
materials required for installation to be supplied by the
contractor.VHF equipment, SMPS power
supply,Antenna &antenna cable will be supplied by the
Railways.
61 61 Supply of 0dB gain adjustable GP antenna for VHF set Numbers 2.00 2680.00 5360.00
Model No: GM300/GM338/GM950 etc.
62 62 Supply of low loss RF coaxial cable RG 217U with silver Numbers 2.00 8710.00 17420.00
tipped connectors on both ends, 30 meters length.
63 63 Supply of Power supply, SMPS, 12V-For Equipment: Numbers 2.00 5092.00 10184.00
Transreceiver HF/VHF/UHF, Mobile/Static, Output
Current:15A, Charging:Float and Boost.
64 64 Supply and installation of Maintenance Free Battery Numbers 2.00 17420.00 34840.00
12V/100AH. Similar to Amar Raja make or better.
65 65 Supply & installation of Audio Amplifier of Make: AHUJA Numbers 2.00 16500.00 33000.00
Model: SSA-250DP or similar, workable on 230V
AC/12VDC supply with protection. Detail specification as
per GeM product ID No.5116877-1226735898.
66 66 Supply and installation of Column Speakers similar to Numbers 4.00 2632.35 10529.40
Ahuja model ASC-20T including necessary fixtures
required for the work and fixing the same.
67 67 Supply and Installation of Unidirectional Speakers Numbers 8.00 1911.30 15290.40
similar to Ahuja model UHC-30XT along with necessary
fixtures required for the work and fixing the same.
68 68 Supply and fixing of Microphone similar to Ahuja model Numbers 2.00 3364.21 6728.42
PRO-2200SC DX, with suitable stand to the control
console cabinet, as directed at site.
69 69 Supply of Twin Core Multi Strands Screened Cable, Metre 1000.00 24.97 24970.00
cotton braided of reputed make, suitable for speakers.
70 70 Supply and installation of Digital office clock with GPS Numbers 2.00 25000.00 50000.00
synchronisation (stand alone mode) as per RDSO
spec.No. RDSO/SPN/TC / 62 /2008 Rev 3.0 or latest
with RED/Blue LED with complete installation including
all necessary accessories as directed by Railway Site
Engineer.(RED LED)
71 71 Supply of Digital Platform Double Sided Clock with GPS Numbers 2.00 25349.60 50699.20
synchronization as per RDSO Specification No
RDSO/SPN/TC / 62 /2008 Rev 3.0 or latest.Includeing
all the accessories required for the installations.
72 72 Installation, Testing & Commissioning of Digital Clocks Numbers 2.00 4921.60 9843.20
as per Specification.
73 73 Local service terminal portable intel core i7 10th Gen Numbers 1.00 95000.00 95000.00
with windows 10 pro ( 8GB) MAKE-Dell or equivalent as
per Gem specification attached.
74 74 Supply of Digtal transmission set to suit as per Numbers 1.00 42000.00 42000.00
Specification.
75 75 Supply of Cross talk meter of Anu Vidyut Similar. Numbers 1.00 40000.00 40000.00
76 76 Supply of Digtal Earth Tester Det-1 with carrying metal Numbers 1.00 7200.00 7200.00
box and auxiliary earthing net Make Wago or Similar.
77 77 Supply of insulation Tester 10 ( Rishabh or equivalent) Numbers 1.00 5000.00 5000.00
78 78 Supply of Cable fault locator. Numbers 1.00 174900.00 174900.00
79 79 Supply of Rodometer (Distance Recorder) similar to Numbers 1.00 4199.73 4199.73
Bosch Make Model No: 1011662 or better.
80 80 Supply, Installation, Testing and Commissioning of Full Numbers 1.00 69692.45 69692.45
HD PTZ type IP Colour Camera along with 128 GB or
Higher SD Card, housing and mount and all
accessories required for installation purposes as per
RDSO Spec No RDSO/SPN/TC/65/2021, Rev 6.0 Amdt
1 or latest.
81 81 Supply, Installation, Testing and Commissioning of Full Numbers 6.00 18744.86 112469.16
HD Fixed Bullet type IP Colour Camera along with 128
GB or Higher SD Card, includeing housing and mount
and all accessories required for installation purposes
per RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0
Amdt 1 or latest.
82 82 Supply, Installation, Testing and Commissioning of Full Numbers 3.00 17783.59 53350.77
HD Fixed Dome type IP Colour Camera along with 128
GB or Higher SD Card, Housing & Mount and all
accessories required for installation purposes as per
RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0 Amdt
1 or latest.
83 83 Supply and installation of Bracket/Fixture/Angle for Numbers 10.00 7714.36 77143.60
fixing of Cameras at Stations along with all accessories
required.[Detailed Specification in Technical Document].
84 84 Supply Installation, Testing and Commissioning of Numbers 10.00 4742.75 47427.50
Software for VMS and Video Recording software. (Per
camera Licence means Video Management and Video
Recording at multiple locations such as Station, RPF
Post & DC Server room covered by the same license)
asper technical spec and functional requirement as per
RDSO Spec No.RDSO/SPN/TC/65/2021 Rev.6 Amdt 1
or latest.
85 85 Supply of Video Analytic Server software complete with Per Unit 10.00 5211.82 52118.20
all accessories (License per camera means Video
analytic at multiple locations such as Station, RPF Post
& Security control by same license)as per RDSO Spec
No.RDSO/SPN/TC/65/2021 Rev.6 Amdt 1 or latest.
86 86 Supply, installation Testing, integration & Lot 1.00 11987.19 11987.19
Commissioning of Storage System for 30 days
recording at Existing/New Station/ RPF/GRP
Thane/Post/Sites for recording of Cameras from station
along with all accessories required for installation
purposes .Note Bidders are required to quote price for
complete storage and intergration as a LOT at RPF
Thana of Division for all types of Cameras mentioned in
the Schedule. as per RDSO Spec No
RDSO/SPN/TC/65/2021, Rev 6.0 Amdt 1 or latest.
87 87 Supply, installation Testing & Commissioning of Storage Lot 1.00 11987.19 11987.19
System for 15 days recording at one Data Center each
per Division for recording of Cameras from cluster of
station along with all accessories required for
installation purposes .Note Bidders are required to
quote price for complete storage as a LOT for all types
of Cameras mentioned in the Schedule as per RDSO
Spec No RDSO/SPN/TC/65/2021, Rev 6.0 Amdt 1 or
latest. Detailed Specification in Technical Document.
88 88 Supply, installation, Testing, Integration and Lot 1.00 14132.40 14132.40
Commissioning of Command & Control Center
Software, Perpetual Licenses & Hardware and all
accessories required for their Installations and
Integration. It includes Video Management/GUI
Software and Video Analytics/FRS licences of cameras
required for integration ) as per RDSO Spec No
RDSO/SPN/TC/65/2021, Rev 6.0 Amdt 1 or latest.
89 89 Supply and installation of Layer 2 Switch as per Numbers 2.00 43928.22 87856.44
RDSO/SPN/TC/65/2021, Rev.6.0 orlatest. Minimum 8+2
Port Manageable with 8 Nos 10/100/1000 Mbps
Ethernet port, POE+ & Single Fiber 2 Nos 1G SFP Port
with BX SM SFP Optical Modules loaded. with all
accessories etc. As per RDSO/SPN/TC/65/2021,
Rev.6.0 or latest.
90 90 "Supply of Single Mode Patch Cord length 3 meters Numbers 8.00 205.76 1646.08
(LC-SC/SC-SC/LC-LC/FC-LC) asper site requirement .
[Detailed Specification in Technical Document].
91 91 Supply and Installation of 19" 9U Rack Wall/Pole Mount Numbers 1.00 10826.76 10826.76
,with all accessories Like Electrical fitting, Fan Tray,
Patch Panel, Cable Manager, PDU . [Detailed
Specification in Technical Document]
92 92 Supply of 12 Core Metal Strengthened Outdoor Metre 800.00 15.18 12144.00
Unarmoured Optic Fiber Cable (ITUTG-652-D) and all
the accessories required for installation.[Detailed
Specification in Technical Document]
93 93 Supply of STP CAT- 6 Cable compliant with latest Metre 915.00 38.83 35529.45
EIA/TIA-568-C.2 Standard for CAT 6 Cable 305 Mtrs
Roll /Bundle. [Detailed Specification in Technical
Document
94 94 Supply of PVC insulated armored 3 Core 2.5 Sqmm, 14 Metre 500.00 103.52 51760.00
AWG,1.1 KV Grade Outdoor Strengthen Copper for
UPS Power Supply Distributions per BIS/ISI Standards
and all accessories required for installation.[Detailed
Specification in Technical Document]Confirming to
IS:1554 Part-1.
95 95 Supply and Fixing of PVC Conduit Pipe minimum 35 Metre 1000.00 48.03 48030.00
mm Dia ISI Mark.Installation ofPVC Pipe, clamping of
the same on Wall, Pole etc. including with required
clamps & and all theinstallation materials required.
[Detailed Specification in Technical Document]
96 96 Supply and Erection of 15 Feet GI pipe of 100 mm dia Numbers 4.00 5217.00 20868.00
4.5m thickness of mediumquality ISI no: 1230(Part 1)
1990. Having an iron base plate 10 mm thick x 30 cmx
30cm welded atthe bottom of the pipe with four
supports of iron bars of sizes 10 mm dia. The 3 feet
pipe shall beburied in the ground and 12 feet shall be
above the ground. The work includes digging of the pit
onPlatform, laying of cable in between poles in suitable
underground GI pipes, erection of pole andfilling the pit
with 1:3:4 cement, concrete and sand. Final plastering
should be done on the surface.The iron bracket on the
top of the pole shall be provided to fix the CCTV
camera, Protection cover and junction box. The work
includes supply of all the materials required in this item.
[Detailed Specification in Technical Document].
Total 4700024.77
4. ELIGIBILITY CONDITIONS
A) Technical eligibility criteria for non-composite works costing above Rs.50.00 lakhs As
per clause 10.1(a) of IRGCC-2022 ( part-1) :The tenderer must have successfully
completed or substantially completed any of the following categories of work(s) during
last 07 (seven) years, ending last day of month previous to the one in which tender is
invited: 1.Three similar works each costing not less than the amount equal to 30% of
advertised value of the tender, Or 2.Two similar works each costing not less than the
amount equal to 40% of advertised value of the tender or 3.One similar work each
costing not less than the amount equal to 60% of advertised value of the tender (B) In
case of tenders for composite works As per clause 10.1(b)(1) of IRGCC-2022 ( part-
1)1.tenderer must have successfully completed or substantially completed any one of
the following categories of work(s) during last 07(seven) years, ending last day of month
previous to the one in which tender is invited: (i) Three similar works each costing not
less than the amount equal to 30% of advertised value of each component of tender, or
Allowed
1 (ii) Two similar works each costing not less than the amount equal to 40% of advertised No No
(Mandatory)
value of each component of tender, or (iii) One similar work each costing not less than
the amount equal to 60% of advertised value of each component of tender. 2.The
technical eligibility for major component [As per para 10.1(b)(1) of IRGCC April2022]
shall be satisfied by the tenderer or by the JV (in its own name and style) or by lead
member of the JV. 3.The technical eligibility for other components[As per para 10.1(b)(1)
of IRGCC April2022] shall be satisfied by the tenderer or by the JV (in its own name and
style) or by any member of the JV(OR) The technical eligibility for other components [As
per para 10.1(b)(3) of IRGCC-April2022) and 7(a) of IRGCC April2022 (Part-II)]shall be
satisfied by sub contractor. 4.Further details are given in sub paras as under. Tenderer
should go through the Para-10 of the tender form (Second Sheet) for Explanation
including Para 10.1 to 10.5- and other clauses regarding eligibility criteria.The tenderer
shall submit the details and work experience certificates from client for compliance of
technical eligibility criteria.
In case single completion certificate containing more than one component is submitted
by the tenderer, value of each component is to be specified in that completion
certificate. In case tenderer fails to submit completion certificate with component wise
1.1 No No Not Allowed
value bifurcation of work for evaluation of technical eligibility, the certificate shall be
treated Incomplete and invalid and shall not be considered for evaluation of technical
eligibility.
Separate completed works of minimum required values for each component shall also be
1.2 No No Not Allowed
considered for fulfillment of technical eligibility criteria
Work experience certificate from private individual shall not be considered. However, in
addition to work experience certificates issued by any Govt. Organisation, work
experience certificate issued by Public listed company having average annual turnover
of Rs 500 crore and above in last 3 financial years excluding the current financial year,
listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered
at least 5 years prior to the date of closing of tender, shall also be considered provided
1.3 the work experience certificate has been issued by a person authorized by the Public No No Not Allowed
listed company to issue such certificates. In case tenderer submits work experience
certificate issued by public listed company, the tenderer shall also submit along with
work experience certificate, the relevant copy of work order, bill of quantities, bill wise
details of payment received duly certified by Chartered Accountant, TDS certificates for
all payments received and copy of final/last bill paid by company in support of above
work experience certificate
In case of JV firms are participated, Technical, financial eligibility and Bid capacity of
1.4 the JV shall be adjudged based on satisfactory fulfillment of Clause no.17.15.1,17.15.2 No No Not Allowed
& 17.15.3 respectively of Part-I of IRGCC-April-2022 with up-to-date correction slips
Defination of Similar Work :- Execution of signalling work (EI/RRI/PI/Auto Block
1.5 No No Not Allowed
Sig/IBS/IBH) either indoor or outdoor or both.
The Tenderer shall be eligible only if he fulfils the following Standard Financial Eligibility
Criteria FOR WORKS COSTING ABOVE Rs.50.00 LAKHS: The tenderer must have
minimum average annual contractual turnover of V/N or 'V' whichever is less, where V=
Advertised value of the tender in crores of Rupees N= Number of years prescribed for
completion of work for which bids have been invited. The average annual contractual
turnover shall be calculated as an average of "total contractual payments" in the
previous three financial years, as per the audited balance sheet. However, in case Allowed
1 No No
balance sheet of the previous year is yet to be prepared/ audited, the audited balance (Mandatory)
sheet of the fourth previous year shall be considered for calculating average annual
contractual turnover.The tenderers shall submit requisite information as per Annexure-
VIB, along with copies of Audited Balance Sheets duly certified by the Chartered
Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance
Sheet. Client certificate from other than Govt Organization should be duly supported by
Form 16A/26AS generated through TRACES of Income Tax Department of India.
Bidders shall confirm and certify on the behalf of the tenderer including its constituents as under:
S.No. Description
1 I/we the tenderer (s) am/are signing this document after carefully reading the contents.
2 I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have
verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the
3
tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment
of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and
4
attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and
5
same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully
6
responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt.
7 of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the
partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for
evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract
8
including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our
offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the
award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and
9
Performance guarantee and may also lead to any other action provided in the contract including banning of business for a
period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India
and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent
10
Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of
valid registration by the competent authority is enclosed)
Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.
S.No. Description
Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. Please
submit a certificate in the prescribed format (please download the format from the link given below). Non submission of the
1 certificate, or submission of certificate either not properly filled in, or in a format other than the prescribed format shall lead to
summary rejection of your offer.
( Click here to download the Format of Self Certification)
5. COMPLIANCE
Check Lst
Commercial-Compliance
In case of Proprietary Firm / Proprietary Concern, the tenderers shall scan and
submit with his offer (i)An undertaking that he is not blacklisted or debarred by
Railways or any other Ministry / Department of Govt. of India from participation
in tender on the date of opening of bids, either in individual capacity or as a
member of the partnership firm or JV in which he was / is a partner/member. Allowed
1 No Yes
Concealment / wrong information in regard to above shall make the contract (Optional)
liable for determination under Clause 62 of the General Conditions of Contract.
(ii)All other documents in terms of explanatory notes in clause 10 of IRSGCC -
April-2022-Part-I. (iii)All other documents as per Clause 14 of IRSGCC - April-
2022- Part-1.
In case of Partnership Firm, the tenderer(s) shall scan and submit with their
offer, the following documents: (i)A notarized copy of partnership deed or a
copy of partnership deed registered with registar . (ii)A notarized or registered
copy of Power of Attorney in favour of the individual to tender for the work,
sign the agreement etc. and create liability against the firm. (iii) An undertaking
by all partners of the partnership firm that they are not blacklisted or debarred
by Railways or any other Ministry / Department of the Govt. of India from
Allowed
2 participation in tenders / contracts as on the date of submission of bids, either No Yes
(Optional)
in their individual capacity or in any firm/LLP in which they were / are
partners/members. Any Concealment / wrong information in regard to above
shall make the bid ineligible or the contract shall be determined under Clause
62 of the Standard General Conditions of Contract (iv)Other documents as
mentioned in terms of para 10 tender form (2nd sheet) of IRSGCC April-2022-
Part I. (v) All other documents as per Clause 14 and Clause 18 of IRSGCC -
April -2022- Part 1.
In case, the Tenderer is a Company, the tenderer(s) shall scan and submit
with their offer, the following documents: (i)The copies of MOA (Memorandum
of Association) / AOA (Articles of Association) of the company (ii)A copy of
Certificate of Incorporation (iii)A copy of Authorization/Power of Attorney
issued by the Company (backed by the resolution of Board of Directors) in
favour of the individual to sign the tender on behalf of the company and create
liability against the company. (iv)An undertaking that the Company is not
Allowed
3 blacklisted or debarred by Railways or any other Ministry / Department of No Yes
(Optional)
Govt. of India from participation in tender on the date of opening of bids, either
in individual capacity or as a member of the partnership firm or JV in which the
Company was / is a partner/member. Concealment / wrong information in
regard to above shall make the contract liable for determination under Clause
62 of the General Conditions of Contract. (v)All other documents in terms of
para 10 of tender form (2nd Sheet) of IRSGCC-2022 (vi) All other documents
as per Clause 14of IRSGCC -April -2022- Part 1
If the tenderer is a JV Firm, the tenderer(s) shall submit with their offer the Allowed
4 No Yes
following documents: (Optional)
A copy of Memorandum of Understanding (MoU) duly executed by the JV
members on a stamp paper, shall be submitted by the JV along with the
tender. The complete details of the members of the JV, their share and
responsibility in the JV etc. particularly with reference to financial, technical
and other obligations shall be furnished in the MoU. Joint Venture members in
the JV MoU shall authorize Lead member on behalf of the Joint Venture to
Allowed
4.1 deal with the tender, sign the agreement or enter into contract in respect of the No Yes
(Optional)
said tender, to receive payment, to witness joint measurement of work done,
to sign measurement books and similar such action in respect of the said
tender/contract. All notices/correspondences with respect to the contract would
be sent only to this authorized member of the JV. The tenderer shall also
submit a copy of notarized Power of Attorney to submit the tenderer on behalf
of JV.
General Instructions
Special Conditions
An offer shall become invalid get summarily rejected if the tenderer adds any
6 condition on his/their own (anywhere in the e-offer), which is in violation of the No No Not Allowed
Railway's Tender Conditions.
An offer shall become ineligible for award of the tendered work if the tenderer
does not fulfil the Eligibility Conditions, (both the Standard Financial Eligibility
7 No No Not Allowed
Criteria and the Standard Technical Eligibility Criteria) prescribed in the Tender
Documents and bid capacity if applicable
IN CASE OF ADVERTISED TENDER VALUEIS MORE THAN Rs.50 Crores,
Electronic Reverse Auction(e-RA) method will be applicable as per guidelines
8 No No Not Allowed
issued by Railway Board vide Lr.No.2017/Trans/01/Policy/Pt-D dated
28.03.2018 (Copy attached in the list of documents)and amendment thereof
Technical-Compliances
Undertakings
Custom
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by
Department of Induswww Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no.
2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017 and amendments/ revisions thereof.
As a Tender Inviting Authority, the undersigned has ensured that the issue of this tender does not violate provisions of
GFR regarding procurement through GeM.
Designation : Dy.CPM/SnT/GS/UBL