แปลงไวเมท

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NEO RC. Design v4.50(WSD.

)
[Project] [Owner]
[Building] [Engineer]
[Location] [Date]
[ WIRE MESH DESIGN ]
2
When : As1 = Require Area Of Wire Mesh(cm. /m.)
As2 = Require Area Of Reinforcedment(cm.2/m.)
Fs1 = Allowable Tensile Strength Of Wire Mesh(kg./cm.2)
Fs2 = Allowable Tensile Strength Of Reinforcedment(kg./cm.2)
#
When Design By Use Reinf. RB 9 mm. @ 0.250 m.
2
As2 = 2.540 cm. /m.
When : Fy1 = 5,500.00 ksc.
Fs1 = 2,750.00 ksc.
Fy2 = 2,400.00 ksc.
Fs2 = 1,200.00 ksc.
From : As1 = As2 x [Fs2/Fs1]
2
So Require As1 = 1.110 cm. /m.
From Calculate : Select To Use Wire Mesh
For : Dia. 4 mm. @ 0.110 m.#
สรุ ป : เลือกใช้ ตะแกรงเหล็กเพือการทํางานดังนีได้
Set 1 : Dia. 4 mm. @ 0.200 m.#
Set 2 : Dia. 4 mm. @ 0.250 m.#

You might also like