Additional Case Study for HGI 46-48 Coal Regarding Units 5 to 7, we added the evaluation result of alternative case of HGI 46-48. (1)In the coal properties of moisture 34.0%, HGI 46, the pulverizer can be operated under the conditions of 200P66% and 6 pulverizers. (Please refer to Case 2 in the following Table for the details.) (2)In the coal properties of moisture 25.0%, HGI 46, the pulverizer can be operated under the conditions of 200P60% and 5 pulverizers. (Please refer to Case 3 in the following Table for the details.) (3)In the coal properties of moisture 25.0%, HGI 46, the pulverizer can be operated under the conditions of 200P70% and 6 pulverizers. (Please refer to Case 4 in the following Table for the details.) Additional Case Study based on PIP coal. Additional Case Study for HGI 46-48 Coal