Manual Instruction of remote control 2DRA-004

一、Specifications
1. Receiver
Input Voltage:AC200V-250V 50HZ/60HZ Motor Voltage:AC200V-250V 50HZ/60HZ
Protective Tube:250V 10A Output Power:1000W
Temperature:-20℃-65℃
2. Remote
Working Voltage:
White Type(with 3 keys):6V (2016 button battery*2)
Black Type(with 4 keys):12V (23A battery*1)
Working Current:≤15mA Working Frequency: 433MHz Temperature : -20 ℃ -65 ℃
Remote Distance:≤50m

Line Control、Open、Close、COM、Stop(Photocell NC connector)、24V+、24V-、PE GND、Fire Line、Zero Line、


Alarm Light、Open(Motor Line)、COM(Motor Line)、Close(Motor Line)
二、 All functions in Receiver
1、Line Control: Connect with push button switch; Open, stop, close and stop can be controlled
by only one key
2、Open – Signal input end of opening key
3、Close – Signal input end of closing key
4、COM – Signal common end
5、Stop – Signal input end of stopping key: NC connector is valid when connecting with photocell
6、24V positive output
7、24V negative output
8、PE GND ground interface to prevent electric shock due to leakage.
9、AC230V—Fire line L input end
10、AC230V—Zero line N input end
11、Alarm light – Fire line L output end(AC230V)
12、Alarm light – Zero line N output end(AC230V)
13、Output end of tubular motor opening door
14、Common end of tubular motor
15、Output end of tubular motor closing door

三、Key function description:

STUDY-Remote control learning key :

1、Increase the remote control


2、Delete all the remote control keys

四、Dial switch instruction


OFF -- ON
1、Open Inching -- Linkage
2、Close Inching -- Linkage
3、Auto-closing Off -- 15s auto-closing base on limit sudy
mode is on
4、Motor direction control Open、close -- Close、open
5、One-key/multi-key control Multi-key conrol-- One-key control
6、Limit study mode Off -- On

二、Function
Add/delete remote
1、Add remote: Push “study” key and loose it until you hear a sound, now it is study mode.
Push one key on new remote three times continuously, when you hear a sound, then study
successfully. If fail, please follow these steps and study again. You need to finish the study within
8s, if more than 8s, the study mode will be off automatically (you will hear the sound twice)
(Note: For four keys remote, push key 2 and key 3 together, it will be distance studying guidance
mode. If this four keys remote has studied successfully, you can enter/exit the distance studying
mode by push this key).
2、Delete remote: Keep pushing “study” key, don’t loose it when you hear a sound, and
loose it until you hear the sound sounds for a while, it means delete all remotes.
3、Remote storage capacity: 40pcs. If more than 40pcs, the first study remotes will be
deleted.

Limit study

1、If you open the learning function of the trip without learning or cutting off the power,
then the buzzer will keep singing at this time.
2、After limit study mode opens, push key 1 and key 2 (open、close the door) on remote
together, you will hear a sound, then it is limit study mode.
3、During limit study mode, please let door fully open、stop/close、stop/move, the limit
time will be recorded as a standard time to stop automatically. (Note: Only the last limit
study time will be recorded). If you don’t operate more than 8s(motor doesn’t move), then
this mode will be exited.
4、Keep pushing key 1 and key 2 together again, when you hear the sound twice, then limit
study mode is exited.

Auto-closing function
Limit time has been set up, open the door to up limit position, the door will close after 15s
automatically. (Noted: If limit time doesn’t be set up, motor running time is 4min, the door will
close after 4min15s when fully open)

One key/multi-key control


1、For one key control, only the first studied key can control. If change to another key, you
need to study again , push “study” key.
2、One key control is same as line control, open、stop、close、stop.
3、For inching/linkage control, pushing the key is open/close, loose it is stop.

三、Remote instruction
Key 1: Open
Key 2: Close
Key 3: Stop
Key 4: Lock
Push key 1 and key 2 together: Enter/exit limit study mode.
Push key 2 and key 3 together: Enter/exit distance study mode.
Note: For one key mode, distance study and limit study mode can not be entered. If it has
been studied before, then it can still work.
四、Security description:

1、 It has the function of infrared anti pinch. When the door is blocked, it will
automatically rebound 3S.
2、 The normally closed signal is normally used as a trigger signal. Once the line is
disconnected, it can be immediately known and checked.
3、 The boxed button can be used as an emergency stop button and can be stopped
at work.
4、 The use of potting transformer is safer than ordinary transformer.
5、 Boxed fuse protection line
6、 Acousto-optic reminding
7、 In remote control learning, the same button should be pressed 3 times in a
short time to prevent crosstalk.

五、Infrared module wiring diagram:


六、The wiring diagram of the external keyboard is illustrated.: