AYBEY ELEKTRONİK

GLCD VERTICAL MODULE

USER GUIDE
v3.0

© AYBEY ELEKTRONIK LTD.


Kartal Cad. No:39 81450 Yakacık İstanbul / Türkiye
Tel: (90) (216) 377 08 02-309 06 45-309 06 54-309 07 18
Fax: (90) (216) 451 58 68
E-mail: support@aybey.com Web: www.aybey.com

-1-
1) INSTALLATION OF GLCD PROGRAMMER

TO INSTALL GLCD PROGRAMMER PLEASE FOLLOW THE STEPS BELOW:

1-Firstly insert CD that is given with our product. CD will run automatically and Off-line version of
www.aybey.com will be seen. You can load the GLCD Programmer installation files to your
computer as defined below.

English!Support !PC Connection Programs !GLCD Programmer (V3.X)(version no)

WARNING: IF CD WILL NOT RUN AUTOMATICALLY YOU CAN REACH SOFTWARE


INSTALLATION FILES AS DEFINED BELOW.
My Computer ! CD-ROM ! Programs! English! GLCD_V3.x _en.exe

2-Load the installation files to a suitable directory.( By default it will load to C:\aybey\ directory)

3-Open installation files directory and run setup.exe. Press OK button to skip the questions on the
screen. The Program will be loaded to the C:/Program Files/GLCD directory. To load a different
directory press “change directory” button and then select directory.
4-Program will be loaded with the name of GLCD. You can reach the program by that way:
START! PROGRAMS !GLCD

2) INSTALLATION OF HARDWARE
Please follow the steps below to connect GLCD to PC .

1-Connect the serial cable (that is given with GLCD) to the serial port of your computer (Known as:
COM1, COM2 or RS232 ).

2- Connect GLCD to the power supply. Connect DC power supply between (V+ ve V-). V+ is
positive voltage and the voltage difference between V+ and V- must be in the range of 15 - 24 V .

-2-
3) AREA DEFINITIONS AND SCREENS

GLCD has 2 areas. These areas can be programmed separately. They are shown below.

TEXT
LINES 1-3

NUMBER

TEXT
LINES 4-6

Areas are named as number and text. In these areas you can program GLCD to show icon,
number, full screen picture, text and arrow.

GLCD screen areas can be programmed for 3 cases of cabin :


MOVING, APPROACHING TO FLOOR and AT THE FLOOR.

These cases are defined below.

MOVING: When digital input I2 is active, GLCD is in this case.


APPROACHING TO FLOOR: When I2 input passed passive from active GLCD is in this for 4
seconds. .
AT THE FLOOR: This case starts 4 seconds after I2 input became passive.

4) PROPERTIES OF AREAS
TEXT AREA
Text area has 2 parts, 3 lines at the upper side (1-3), 3 lines at the lower side (4-6),so the total is 6
lines, every line can be programmed separately.
You can set 7 different options for every lines at the text area :

a) General Subtitle : The message that is shown at all floors at the related line.
b) Subtitle special to floor : The message that is shown at the related line special to floor.
c) Time : Time message that is shown at the related line
d) Date : Date message that is shown at the related line
e) Day : Day message that is shown at the related line
f) Arrow : Arrow message that is shown at the related line
g) Empty : Empty message that is shown at the related line

WARNING If an arrow is wanted at the one of the lines, other lines can not show anything and only
an arrow is shown on text area. For example if arrow is selected for the line 2 then line1
and line3 also shows arrow.

-3-
NUMBER AREA
There are 9 different options at the number area.

a) Floor Number : Shows the floor number. 1 or 2 characters can be used for the floor indicator.
b) Special floor icon : Shows special floor icon which can be selected from the icons that are present
in GLCD or prepared by user.
c) General icon : Shows general icon (for all floors) which can be selected from the icons that are
present in GLCD or prepared by user.
d) Arrow : Shows selected arrow symbol.
e) Programmable Picture 0-1-2 : Shows full screen picture that will be shown at all floors. (picture
is prepared by user)
f) Special floor picture : Shows full screen picture that is programmed by user.
e) Empty : Nothing shown at the number area.

WARNING Programmable picture 0-1-2 is the full screen pictures 0,1 and 2. of user according to
GLCD index number.

WARNING To form Special floor pictures and Programmable pictures and to send them to the
2 GLCD is the mission of user. There is no factory loaded pictures.

Separately in the text area


for 7 lines
a) Own text of the floor
b) Global text
c) Time

Number Area
a) Floor Number
b) Floor Icons
c) General Icon
d) Arrow
e) Programmable Picture 0-1-2
f) Full screen picture can be
shown special to floor

d) Date
e) Day
f) Arrow
g)Empty

-4-
5) To Program GLCD by using PC

a) Installation of Programmer Software

1-Run setup.exe file that includes installation


files.
2-Then you will see the message window. Click
Ok Button.
3-Then click computer icon.
4-Accept installation directory and finish
installation.

b) Preparation of GLCD Hardware

1- Connect one end of the RS232 cable to GLCD and other end to the serial communication port
(COM1,COM2 ….) of PC
2- Connect power supply at (V+) (V-) terminals.

c) Running of Programmer

Follow the steps below to run GLCD Programmer :


1- Be sure that supply of GLCD is on and serial connection cable is connected.
2- Enter to GLCD menu by pressing ENT button a few seconds.You will see the MAIN MENU on
the screen.
3- Follow the steps below to run Programmer : START!PROGRAMS!GLCD
4- When GLCD Programmer runs choose the serial port that you connected GLCD to the PC:
File !Select CommPort
5- Transfer the content of GLCD to PC. (This process will be explained below) When the copying
finishes you can program GLCD from PC.

d) Transferring the contents of GLCD to PC

If there are settings on GLCD and you want to


change these settings firstly you have to load the
content of GLCD to PC. At the end of loading
process you can do all changes that you want. To
load GLCD content follow the steps below:

- Enter GLCD menu. To do this you have


to press ENT button (for a few seconds).
GLCD main menu will seem on the
screen.

- Click 'Load fields from GLCD' button


from file.

- Loading procedure of GLCD content will


start and loading status will seem on the
screen of PC.

-5-
e) Saving Content in File

You can keep the content of GLCD in your own PC. You can load lots of GLCD configurations in
your disk, you can reserve, and whenever you want you can load them back to GLCD. Thus you can
use a configuration in lots of GLCD and you can make all changes. To keep the content of GLCD in
file, you have to click 'Save Fields to File' button. Name your file, and choose the directory that you
want to load the file. If a directory is not choosen GLCD Programmer will keep the file in the
eprom_images directory.

f) Loading the Content from File

If you want to load the files that you saved before, you have to click 'Load Fields from File' button.
Click the file that you saved before and click open button from the dialogue box. File will be loaded
to GLCD Programmer content. If you did not determined a directory when you were saving
configuration file , your file will be kept in the eprom_images directory.

g) Preview Window

In this window you can see the GLCD setup. By this property, to programme GLCD becomes very
easy. You can make all changes and can see them on GLCD.

Preview can be done in two way. Firstly you must choose the floor number that you want to preview.
If you want to preview with floor number you have to click 'preview(with floor number)', but if you
want to preview with floor icon you have to click 'preview(with floor icon)' button.

h) Floor Settings

You can do all special settings in that picture(floor texts, icon). You have to choose the floor number
before changing the floor settings. After this, all changes will be special to that floor. The settings you
can change are defined below :

Text : Includes 6 lines and every line can is programmable separately.


Floor Symbol : This character will be saved as floor number. If only one character is written
it will be centred.
Floor Icon : Floor icon will be saved in the number area of GLCD. First 48 icon is in the
GLCD memory. You can find the icon list at the end of the guide. Last 20 icon can be designed by
user. User can send a picture to GLCD as an icon. We will tell about it below. You can see the floor
icons and other texts by clicking preview button.
Floor Picture : You can choose floor picture or user designed picture. User can design 10 full
screen pictures.

WARNING The changes that you made at GLCD Programmer will not be sent if you don't click
save all records button. When you have made all the changes you have to click save
all records button to send and save settings. If you want to save these record only to
file you have to click save fields to file. Saving to file is told above.

i) GENERAL TEXT
In this picture you can organize global text, global icon, global overload and global service mode that
will be seen at all floors.

-6-
j) SYSTEM SETTINGS
You can view moving, approaching to floor, at the floor cases in this picture. You can determine
number and text elements for 3 different conditions ( moving, approaching to floor, at the floor). You
can programme every line for three different cases.

h) OTHER SETTINGS

You can change the settings below by using this picture :


- Floor Enter Mode (Gray Code or Binary)
- Date and Time Setup
- Date and Time Show Font(Monospace, Bankotik, Arabic Font)
- Arrow Animation (With Animation, Static)
- Arrow Style (Classics, Hand, Star, Classics2, Programmable Arrow)
- Number Font (Monospace, Arabic Font)
- Power Saving Mode (Economical, Normal)
- Frame (The Frame that surrounds number area)

5) TO ESTABLISH PICTURE, ICON, ARROW WITH GLCD PROGRAMMER


Aybey Elektronik presented new
properties after Version 3. After Version 3
there are 10 full screen pictures, 20 icons
and an arrow in GLCD that can be
designed by user. You can design your
pictures in Photoshop, MSPaint ,etc and
you can load that pictures GLCD Logo
Editor.
You can view the original picture
from the window named as original and
you can view the form that will be sent to
GLCD from the icon named window.

To do this please follow the steps below.


1- Design a picture by using a picture program. GLCD Logo Editor can work with colourful
pictures but some loses can occur when it is transformed to GLCD Format. If you follow the
below object loses will be minimum.
a) Design pictures white/black(monochrome)
b) Resolution of Full screen pictures must be 240*128, icons
96*93 and arrow 56*72. And also resolution can be multiplied
with an integer(480*256 and192*186)
c) Detailed pictures will have loses in the low resolution.
2- Before running GLCD Programmer please close the windows which are unnecessary. Because
sending logo to GLCD requires processor power and timing is important to do this.
3- Connect GLCD to PC and then run GLCD Programmer. Be sure that hardware is connected
correctly and the serial port is true. Then click ''create logo and send'' button.
4- The Program will contact with GLCD and copy the files to PC that are loaded before(picture,
icon, arrow). You can follow copying process from the state bar that is located under Logo
Editor. If an error occurs please be sure that bellower steps are made truly and than restart
GLCD to do the same procedure.
5- Determine the picture kind(picture, icon, up arrow or down arrow) and picture index.

-7-
6- GLCD uses different algorithms during transforming to GLCD format. The pictures that are
loaded to GLCD will have a new dimension automatically, and colourful pictures becomes
colourless. If details are important we advice you to use sensitivity setup is detailed, and if
details are not important (like graphics,texts,logos) we advice you to use undetailed setup.
Undetailed setup is chosen by default. You can load the same picture with different setup and
see the result from the icon window. Lastly loaded picture will be valid and will be sent to
GLCD.
7- Click ''load picture'' button and choose the picture. Transform will start in the same time. You
can follow the process from the state bar. When the process is okay you will see 'the picture
is transformed successfully' message.
8- Follow the steps from 5 to program picture,icon and arrow again.
Index and format selection > sensitivity selection >loading picture
9-When you finished everything click send to LCD button. Saving period will start and you can
see the period from state bar. If an error occurs click the same button again. If the same error is
continuing you have to restart GLCD (without closing GLCD Logo Editor) and click send to
LCD button
10- If saving period is okay, to view the files on GLCD you can click preview button. If an error
did not occur pictures are ready. You can reach full screen pictures, icons, arrows from the GLCD
Programmer or the menu in GLCD.

6) TO PROGRAMME GLCD BY USING GLCD BUTTONS


There are three buttons on GLCD module. The buttons that are in the back of GLCD are
named as ENT(enter) DEC (decrease) and INC (increment) . You can do settings mostly by using this
buttons. To programme GLCD with buttons is easy but there is a disadvantage: to order writings. If
you are not able to programme it with PC you can do a few settings by using GLCD menu.
To enter the GLCD menu press ENT button until the menu occurs on the screen. Firstly you
will see the sub-menu alternative. You can see GLCD menu by clicking INC and DEC buttons. To
choose an item, click ENT button when the cursor is on that item. If you press ENT button for short
time you enter that menu, but if you press ENT button for a short time you leave that menu.

MAIN MENU
MO EDIT TEXT
M1 GLOBAL TEXT
M2 SETUP
M3 CLOCK/DATE
M4 LANGUAGE
M5 ARROW SET
M6 DEF.SETUP
M7 SIMULATOR
<< EXIT

EDIT TEXT : Floor texts, number, icon and pictures are set by this button and preview can
be done.
GLOBAL TEXT : You can change texts, icons, service mode and overload texts by using this
button.
SETUP : All configuration settings can be done by this button .
CLOCK/DATE : You can set the time and set show font by this button.
LANGUAGE : GLCD menu language can be set (Turkish/English) by this button.
ARROW SET : Arrow animation position and style can be designed by this button.
DEF. SETUP : It returns to the factory settings if you accept.
SIMULATOR : You can reach simulator settings by clicking this button.

-8-
Main Menu

Text Input Global Settings Language Default

Global Text Clock Settings Arrow Setting


Simulator
Which floor?
Text
Text Time Set
At Floor
Line 1 – 6
Number Clock Font
Approaching
Icon Line 1 – 6

Picture Moving
Line 1 – 6 Arrow State
Preview N
Arrow Style
Number
Preview P
At Floor

Approaching

Moving
Subtitle

Side Title Number Font

Icon Variables

Out Of Service Energy Mode

Overload Coding

Frame

-9-
TEXT INPUT MENU OF GLCD MODULE
Before entering menu of text input, you have to choose the floor that you will change and set
writings.

Enter Floor number by using INC and DEC


MAIN MENU buttons and then press ENT.
MO EDIT TEXT
M1 GLOBAL TEXT WARNING: If floor number has one digit,you
M2 SETUP have to choose the first digit 0.
M3 CLOCK/DATE
M4 LANGUAGE
Now you are at the menu of related floor, you
M5 ARROW SET
M6 DEF. SETUP can choose the text that is special to floor, you
M7 SIMULATOR can choose floor icon, you can setup full screen
<< EXIT display and you can see a preview.
Which Floor?: 0_

ENTER TEXT 8.FLOOR If you want to write a text that is special to floor
E0 SUBTITLE you have to follow the steps below. When you
E1 NUMBER enter the 'Text' it will ask you which floor do you
E2 SIDE TEXT want to set. Enter the Floor Number. By using
E3 İCON
E4 PICTURE
INC and DEC buttons we choose the character.
E5 PREVIEW_N Than press enter shortly. The cursor will stop
E6 PREVIEW_P blinking. We choose the character with INC and
<< BACK DEC buttons. Save the character by pressing
ENT shortly. Now again we can see the
characters of underline by pressing INC and
DEC buttons. Until the end of text you have to
follow this steps. To save settings you have to press ENT for a long time,and than go back to uppuer
menu. If you want to exit without saving, press INC and DEC at the same time.

All these steps are valid for floor icon and the pictures that are special to floor.

Furthermore, you can see a preview of floor number by using Preview_P button.

8. FLOOR
5. LINE
ENTER TEXT 8. Floor
E0 TEXT
E1 NUMBER
E2 ICON
E3 PICTURE
E4 PREVIEW_N
E5 PREVIEW_P
<< BACK

Lıne No?: 5
ENT CHANGE

INC FOLLOWING

- 10 - DEC PRECEDING
GLCD Module Global Text Menu
By using GLCD Global Text Menu you can organise Global subtitle, Global side text, Global icon,
Global service text, Global overload text.
Global text and global icon is not related to floor,
GLOBAL TEXT they can be seen at all floors.
E0 SUBTITLE
E1 ICON
E2 SERVICE
E3 OVERLOAD
<< GERİ

GLCD Module Global Settings Menu


Global Settings Menu is used for setting of Subtitle, Side title and Number areas at the floor position,
coming to floor position and movement position.

GLOBAL TEXT G0 At the Floor, G1 Approaching To Floor


and G2 Moving
_TEXT_ Includes show settings for every 6 line:
G0 AT THE FLOOR
G1 COMING TO FLOOR
G2 MOVEMENT a) General Subtitle
G3 NUMBER b) Special to Floor Underline
G4 VARIABLES c) Time
<< BACK d) Date
e) Day
f) Arrow
g) Free

Number
You have to choose number font. Furthermore, for the positions of at the floor, approaching to
floor and movement:
0- For Empty Projection
1-Show floor number.
2-Show floor picture
3-Show general picture
4-Show arrow
5-Programmable Picture 0 ( Full screen picture with 0 index, seem at all floors)
6-Programmable Picture 1 ( Full screen picture with 1 index, seem at all floors)
7-Programmable Picture 2 (Full screen picture with 2 index, seem at all floors)
8-Full screen picture that is special to floor.
WARNING If you choose a full screen picture all other pictures will be closed.

- 11 -
Variables
Energy Mode
0-Economical Mode (GLCD will turn lightning if it does not sense any movement for 12
minutes )
1-Normal Mode (No energy saving)
Signal Mode
0-Binary Code (Uses floor information as Binary Code.)
1-Gray Code (Uses floor information as Gray Code .)
Frame
0-No Frame (No frame is used at the number area)
1-With Frame (Frame is used at the number area )

GLCD Module Language Selection and Arrow Menu


Language:
LANGUAGE SELECTION
L0 LANGUAGE 0
<< BACK By using this buttons you can choose Menu
Language. There are two alternatives:
Turkish/ English.

ARROW CONFIGURATION Arrow:


A0 ARROW STATE 0
A1 ARROW STYLE 0 In the arrow menu you can set arrow show
<< BACK condition. There are 2 different conditions
for arrow: statical show and animated show.

Furthermore, you can choose ( 4+1


Programmable) any arrow styles.
Arrow styles are shown below.

0-Classical 1-Hand Style 2-Star 3-Classical 2

#! " !
- 12 -
GLCD Module Default Settings Menu

ARE YOU SURE


RETURN BACK TO
DEFAULT SETTINGS

NO YES
LEFT RIGHT

GLCD returns to default settings with this menu. Floor numbers are shown with 0-31 numbers. All
the personal settings will be deleted. There will be an arrow on the side title. You can turn back to
fabric settings by pressing right button (DEC) .
GLCD Module Simulator Menu
SIMULATOR
D0 STATE 0 GLCD includes a simulator to see the settings
D1 FLOOR NO 03 without connecting a board. The parameters
D2 MOTION 5 below are used for simulator settings.
D3 WAIT_TIME 10
<< BACK State: On/Off
Floor No: 1-32
Motion: Active time of movement
signal(second).

- 13 -
GLCD Module Icon Catalogue

0:! 16:2 32
1:" 17:3 33:!"
2:# 18:4 34:#"
3:$% 19:5 35:$"
4:&% 20:6% 36:"#
5:' 21:7% 37:$#
6:( 22:8 38:%#
7:)% 23:9% 39:&#
8:* 24:: 40:"#
9:+ 25:; 41:'#
10:, 26:< 42:(#
11:-%% 27:=% 43:)#
12:. 28:> 44:*#
13:/ 29:?% 45:+#
14:0 30:@ 46:,#
15:1 31:A 47:

- 14 -
1 2 3 4

GLCD CONTROL BOARD +12V MODEL (FOR SUPPLY AND SIGNALS) IS ALSO AVAILABLE.

D D
V- GND
V+ +24V DC
GLCD
B
A NOT USED.
GND

VB+
INVERTER + VB-
-
C I2 HS (HIGH SPEED) C
RH (HIGH SPEED)
I1
39 39 OUT OF SERVICE
35 35 OVERLOAD SIGNAL
32 32 UP ARROW
LAMPS
31 31 DOWN ARROW
12 12 BUSY
SC SIGNAL COMMON
M4 M4
BI-STABLE
M3 M3 FLOOR
B B
M2 M2 MAGNETIC
INFORMATION
M1 M1
SWITCHES
M0 M0
MC MAGNETIC COMMON

SIGNAL MAGNETIC
SC LAMPS HS MC SWITCHES
A
OPTION 1 +24 GND GND +24 GND Title
A
GLCD CONTROL BOARD CONNECTION SCHEMATICS
OPTION 2 GND +24V +24V GND +24V
Size Number Revision
A4
GLCD-CON R1
Date: 26-Feb-2004 Sheet of
File: C:\Belgelerim\protel\GLCD SCH\GLCD.DDB Drawn By:
1 2 3 4
1 2 3 4

GLCD CONTROL BOARD


D D
V- 1000(-)
V+ 24V DC
100(+)
GLCD
B
A
GND

INVERTER VB+
+ VB- ***S2O SWLINE
- PROGRAMMABLE
C I2 ***S2A OUTPUTS SWLINE C
POWERTIP I1 CONTROL
39 39 OUT OF SERVICE PANEL
35 35 OVERLOAD
32 32 UP ARROW
31 31 DOWN ARROW
12 12 BUSY
SC
M4 M4
BI-STABLE
M3 M3
B B
M2 M2 MAGNETIC
M1 M1
SWITCHES
M0 M0
MC

***S2O-S2A : SWLINE PROGRAMMABLE OUTPUTS


OUTPUT NO : 00002
OUTPUT CODE : 00012 (FAST OR HIGH MOTION)

Title
A A
GLCD WITH SWLINE CONTROL PANEL
Size Number Revision
A4 GLCD-SW1 R1
Date: 26-Feb-2004 Sheet of
File: C:\Belgelerim\protel\GLCD SCH\GLCD.DDB Drawn By:
1 2 3 4
1 2 3 4

GLCD CONTROL BOARD

D D
V- 1000(-)
24V DC
V+ 100(+)
GLCD
B
A
GND

VB+
INVERTER + VB- AYBEY ELEKTRONIK
-
C I2 (HIGH SPEED) AX or LC C
RH (HIGH SPEED) CONTROL
I1
39 39 OUT OF SERVICE PANEL
35 35 OVERLOAD
32 32 UP ARROW
31 31 DOWN ARROW
12 12 BUSY
SC
M4 M4
BI-STABLE
M3 M3
B B
M2 M2 MAGNETIC
M1 M1
SWITCHES
M0 M0
MC

Title
A A
GLCD WITH AX-LC CONTROL PANELS
Size Number Revision
A4 GLCD&AX-LC R1
Date: 26-Feb-2004 Sheet of
File: C:\Belgelerim\protel\GLCD SCH\GLCD.DDB Drawn By:
1 2 3 4