MultiPlus II 3KW 120VAC 12VDC 600ah Li Lynx Smart BMS & Distributors Cerbo GX Touch Generator MPPT Orion TR Smarts
MultiPlus II 3KW 120VAC 12VDC 600ah Li Lynx Smart BMS & Distributors Cerbo GX Touch Generator MPPT Orion TR Smarts
PV BREAKER/ISOLATOR
VE.Direct
The GX Touch 50 and the CERBO GX
VE.Can
VE.Bus
are enlarged visible in this drawing. ETHERNET SMART MPPT ORION-Tr SMART-1 ORION-Tr SMART-2
VRM SOLAR ARRAY MAIN FUSES Orion Inputs
CERBO GX WORLD as close to starter
GX TOUCH 50 victron energy
BLUE POWER
victron energy
BLUE POWER
victron energy
BLUE POWER battery as possible
HDMI
0W
victron energy
225W
IMPORTANT INFORMATION ! MPPT 100 | 50 12 I 12 - 30 12 I 12 - 30 285060F
60 AMPERE
285060F
60 AMPERE
CERBO VE.Can
must be programmed for
RE
RE
0 OFF 0 OFF
Li-Ion mode-C and 12 Volt
SE
SE
! IP43 IP43 IP43
T
either through programming i i i
PV-Charger on the device itself or with Battery 12/24V 50A
MCB Input I 8-17V
Output I 10-15V
Input I 8-17V
Output I 10-15V
L
O
L
O
Absorbtion
- + victron energy A A
PV 100Vmax 50A
75% 850W
a Bluetooth enabled Power I 360W (30A) Power I 360W (30A) D D
smartphone or tablet.
Float
Bulk
DC Power on/off on/off
340W
12.8V 13.2A BATTERY PV IN GND OUT IN GND OUT
-255W
victron energy
+ - - + L H + - + L H + - +
Spare - ED
CT
Charge light
TE
RO
ALTERNATOR STARTER-MOTOR
N P
OF F I G N I T I O
ORION's H Conn. ORION's H Conn.
Blue Smart
OFF
CERBO Power - ENGINE Ignition ENGINE Ignition Spare - FROM ALTERNATOR D+ ENGINE
G TO
Charger 12V-5A
HIN
ve
CERBO Power +
mo
I TC
MAIN SWITCH-2
Re
SW
AMI IGNITION
R
E
FO
Starter Battery
D4
Load 5 - MOTOR
31 S
li-ion
recondition
mode
victron energy
BAT_MIN
D5
B L U E P O W E R
D2
xxxA
MS-1 Common ON
400A
MultiPlus-II Batt +
MultiPlus-II Batt-
D1
MEGA
xxxA Load 2 +
CERBO Power +
ENGINE Ignition
CERBO Power -
CERBO VE.Can
ORION's H Conn.
MEGA
www.victronenergy.com
ISOLATION TRANSFORMER
IP22
BMS
OR GALVANIC ISOLATOR
REM
SHOULD BE INSERTED
status
H
lynx smart BMS
HERE IF NEEDED.
NC COM NO
MEGA
RELAY
Load 5 +
victron energy
BREAKERS.
ON/OFF
ATD
ATC
POSITIVE
500
+ -
AUX
VE.Can VE.Can
BUSBAR
CERBO
1A PRE-ALARM PIEZO BUZZER 2 x Lithium
Distributor
12.8V-300Ah
Distributor
0.5A
0
MultiPlus-II
60 AMPERE
285060F
PRE ALARM Shore Gen
A
B
T
0.2A 50A
D
A
name name
L
12 |3000 |120
VOLT
AMP
VA
12 Volt 30mA 125/250V
Smart LiFePO4
AC transfer capacity: 50A | Inverter 120V
SE
T MPPT + Easy Lock
RE i IP21 0 OFF 0 OFF 0 OFF 0 OFF
AC in 1 AC out 1
CONNECTORS CONNECTORS
bulk overload
MCB MCB
60 AMPERE
absorbtion low battery
285060F
Spare
A
B
T
float temperature
Dip switch
D
A
L
Battery
position-A SE
T ORION 1 +
SHORE POWER
D3
RE
Before charging read the instructions. For indoor use only. Disconnect
the supply before making or breaking the connections to the battery.
CONNECTION
Spare
batteries only.
D
A
L
victron energy
BAT_MIN
Current +
K1
BLUE POWER
Sense
-
T ORION 2 + +
BAT_PLUS
Ext.GND
SE
D5
VE.Bus Relay
-
RE +
2
ON
AUX 2
1
VE.Bus -
+
Remote AUX 1
On/Off -
+
T-Sense
-
Drawing BJE-318A
Push
AC-OUT-1 AC-OUT-2 AC-IN button A +
350A
Aux V-Sense
N PE L N PE L N PE L RELAY -
COM
NO
NC
TRICKLE
CHARGE
AC OUT 1 AC OUT 2 AC IN
D2
BLUE POWER
On
350A
Lithium Lithium
Off
Charger
Only
12.8V-300Ah 12.8V-300Ah
D1
MultiPlus-II AC IN
Smart LiFePO4 Smart LiFePO4
MultiPlus-II AC OUT-2
MultiPlus-II AC OUT-1
VE.Bus to CERBO Conn-K VE.Bus
MultiPlus-II Batt + Conn-G Batt+ AC DISTRIBUTION
from MultiPlus-II
MultiPlus-II Batt + Conn-G Batt+ AC Out-1 & AC Out-2 GENERATOR 4KW
KEEP POSITIVE BATTERY CABLES MultiPlus-II Batt - Conn-H Batt- 120V/60Hz AC
ALL AS SHORT AS POSSIBLE AND
MultiPlus-II Batt - Conn-H Batt-
ALL AT THE SAME LENGTH !
Conn-F Case ground
KEEP NEGATIVE BATTERY CABLES
ALL AS SHORT AS POSSIBLE AND IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! WARNING
name :hager :hager name :hager :hager
ALL AT THE SAME LENGTH ! Recommended AC Out-1 cable/breaker size MultiPlus-II Recommended AC IN cable/breaker size MultiPlus-II 120 VOLT AC IS EXTREMELY
HAZARDOUS !!! 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF
With Power assist the MultiPlus-II can add AC IN must be protected by a circuit breaker rated DO NOT TOUCH ANY LIVE WIRED
3KW to the output load when needed. at 50A max or less. This depends heavily on the PARTS OF THE INSTALLATION !!!
Together with the adjustable 50A input this size of the connected power source. The input WHEN IN DOUBT, ALWAYS CONSULT MCB MCB
all adds up to the max sum of input and current must be adjusted to fit the size of the YOUR VICTRON DEALER !!!
output current of 50+25=75A. An Earth connected power source.
leakage device with breaker or a The breaker and cable size for AC IN should be
Lynx Smart BMS combination MCB/RCD must be installed
on the output. Cable size must be adjusted
adjusted accordingly.
MultiPlus-II MultiPlus-II
VE.Can VE.Can BMS BMS AC out-1 AC out-2
Enlarged connections AUX ATC ATD RELAY REM accordingly.
+ - NC COM NO H L
IMPORTANT INFORMATION ! IMPORTANT INFORMATION !
Recommended AC Out-2 cable/breaker size MultiPlus-II Recommended DC cable/fuse size MultiPlus-II
PRE-ALARM PIEZO BUZZER Distributor Distributor AC Out-2 only is available when power is 0-5 m cable length: 4 x 50SQmm, 5-10 m cable
present on AC IN. During battery operation length: 4 x 70SQmm. When used in closed 120V No Break load-1
it will be disconnected. conduits, cable size should double. Cable length 120V No Break load-2
FUSES CERBO Power - AC Out-2 supports up to 50A. stands for the distance between the battery and the 120V Switched load-1
CERBO An Earth leakage device with breaker or a MultiPlus-II connections !!! Recommendations are 120V Switched load-2
BMS ON/OFF 1A CERBO Power + combination MCB/RCD must be installed without other loads in the system and these also
on the output. Cable size must be adjusted should be taken into account for proper main
12 Volt SBP CERBO VE.Can accordingly. battery, main fuse & main switch cables !!!
0.5A Fuse size should be 400A.
Blue Smart charger
30mA SBP H-contact
Pre-Alarm IMPORTANT INFORMATION ! IMPORTANT INFORMATION !
0.2A ORION's H Conn.
The primary Case ground connection from a When operating in inverter mode, the Neutral
ENGINE Ignition inverter charger like a Multi or a Quattro, output of a inverter/charger must be connected to
BTV CABLE must be connected to the Central Negative ground to guarantee proper functioning of a
Busbar of the DC system. Size of this cable GFCI or RCD device. In case of a split phase supply
BTV CABLE must be identical to connected DC negative. the Neutral also must be grounded.