Application version: Anton Paar RheoCompass™,
V1.21.825-Release
Licensed for: Indian Institute of Technology
License no. Rh18G7514
Version no. 1.21.0.0
Project: 6/12/2021_ORIGINAL grading (V 1.0)
Input data: 6/12/2021 6:39 PM Original
Binder Grading, <Last
measuring result>, From
interval 1, Point 1
Result data: Asphalt original binder (final)
PREVIOUS RESULTS
Result 1: This sample passed at 70.0 °C with |G*|/sin(delta) = 1.6595 kPa
Result 2: This sample failed at 76.0 °C with |G*|/sin(delta) = 0.7572 kPa
TEST RESULTS:
Mean frequency: 10.0 rad/s = 1.59 Hz
Mean strain: 12.00 %
Mean shear stress: 0.091 kPa
Mean phase shift angle: 88.5 °
Mean complex shear modulus |G*|: 0.757 kPa
Mean temperature lower plate: 76.0 °C
Mean temperature sample: 76.0 °C
ANALYSIS RESULT:
Number of data points: 10
|G*|/sin(delta): 0.7572 kPa
Standard deviation: 0.0017 kPa
Median: 0.7571 kPa
Confidence interval (95 %): 0.7560 ... 0.7584 kPa
AASHTO T315 ORIGINAL BINDER PERF. CRITERION: |G*|/sin(delta) >= 1.0000 kPa
===========================================================================
This sample is found to F A I L at 76.0 °C
===========================================================================
===========================================================================
Pass/fail temperature is 74.0 °C
===========================================================================