FXMQ-P
Ceiling Mounted Duct Type
1. Specifications ......................................................................................222
2. Dimensions .........................................................................................225
3. Piping Diagrams..................................................................................230
4. Wiring Diagrams..................................................................................231
5. Electric Characteristics........................................................................232
6. Safety Devices Setting ........................................................................233
7. Capacity Tables ..................................................................................234
7.1 Cooling Capacity for Te: 6°C................................................................234
7.2 Cooling Capacity for Te: 9°C................................................................234
8. Fan Performances...............................................................................235
9. Airflow Auto Adjustment Characteristics .............................................244
10.Sound Levels ......................................................................................252
11.Centre of Gravity .................................................................................257
12.Accessories.........................................................................................258 11
12.1 Optional Accessories (for Unit).............................................................258
12.2 Optional Accessories (for Controls)......................................................258
FXMQ-P 221
Specifications EDMT341410B
1. Specifications
Ceiling mounted duct type
Model FXMQ20PVE FXMQ25PVE FXMQ32PVE
Power supply 1 phase, 220-240/220V, 50/60Hz 1 phase, 220-240/220V, 50/60Hz 1 phase, 220-240/220V, 50/60Hz
kcal/h 1,900 2,400 3,100
1 2 Cooling capacity Btu/h 7,500 9,600 12,300
kW 2.2 2.8 3.6
6
Cooling 50Hz kW 0.056 0.056 0.060
Power input
Casing / Colour Galvanized steel plate Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×550×700 300×550×700 300×550×700
Model — — —
Type Sirocco fan Sirocco fan Sirocco fan
Motor output × W 90×1 90×1 90×1
Number of units
Fan m³/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7
Airflow rate (HH/H/L) l/s 150/125/108 150/125/108 158/133/116
cfm 318/265/230 318/265/230 335/282/247
External static pressure Pa Rated 50 (100-30 3) Rated 50 (100-30 3) Rated 50 (100-30 3)
Drive Direct drive Direct drive Direct drive
Microprocessor thermostat for Microprocessor thermostat for Microprocessor thermostat for
Temperature control
cooling and heating cooling and heating cooling and heating
Air filter 4 4 4
Liquid pipes mm φ6.4 (Flare connection) φ6.4 (Flare connection) φ6.4 (Flare connection)
Gas pipes mm φ12.7 (Flare connection) φ12.7 (Flare connection) φ12.7 (Flare connection)
Piping
connections VP25 VP25 VP25
Drain pipe mm External dia. 32 External dia. 32
( Internal dia. 25 ) ( Internal dia. 25 ) ( External dia. 32
Internal dia. 25 )
Mass kg 25 25 25
5 Sound pressure level (HH/H/L) dB(A) 33/31/29 33/31/29 34/32/30
Fuse. Fuse. Fuse.
Safety devices
Fan driver overload protector. Fan driver overload protector. Fan driver overload protector.
Refrigerant control Electronic expansion valve Electronic expansion valve Electronic expansion valve
Operation manual. Installation manual. Operation manual. Installation manual. Operation manual. Installation manual.
Drain hose. Sealing pads. Clamps. Drain hose. Sealing pads. Clamps. Drain hose. Sealing pads. Clamps.
Standard accessories Washers. Screws. Insulation for fitting. Washers. Screws. Insulation for fitting. Washers. Screws. Insulation for fitting.
Clamp metal. Air discharge flange. Air Clamp metal. Air discharge flange. Air Clamp metal. Air discharge flange. Air
suction flange. suction flange. suction flange.
Specification C: 3D060388E C: 3D060388E C: 3D060388E
Drawing No.
Sound level C: 4D062535 C: 4D062535 C: 4D062536
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
2. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
kcal/h=kW×860
3. External static pressure is changeable in 7 stages (FXMQ20/25/32PVE), 13 stages (FXMQ40PVE), 14 stages (FXMQ50/63/80/100/ Btu/h=kW×3412
125PVE), 10 stages (FXMQ140PVE) by remote controller. cfm=m³/min×35.3
4. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity l/s=m³/min×1000/60
method) 50% or more.
5. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
6. Power input values are based on conditions of rated external static pressure.
7. Refer to Electric Characteristics for the power input when the airflow rate is maximum at maximum external static pressure.
222 FXMQ-P
EDMT341410B Specifications
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
2. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
kcal/h=kW×860
3. External static pressure is changeable in 7 stages (FXMQ20/25/32PVE), 13 stages (FXMQ40PVE), 14 stages (FXMQ50/63/80/100/ Btu/h=kW×3412
125PVE), 10 stages (FXMQ140PVE) by remote controller. cfm=m³/min×35.3
4. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity l/s=m³/min×1000/60
method) 50% or more.
5. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
6. Power input values are based on conditions of rated external static pressure.
7. Refer to Electric Characteristics for the power input when the airflow rate is maximum at maximum external static pressure.
FXMQ-P 223
Specifications EDMT341410B
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
2. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
kcal/h=kW×860
3. External static pressure is changeable in 7 stages (FXMQ20/25/32PVE), 13 stages (FXMQ40PVE), 14 stages (FXMQ50/63/80/100/ Btu/h=kW×3412
125PVE), 10 stages (FXMQ140PVE) by remote controller. cfm=m³/min×35.3
4. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity l/s=m³/min×1000/60
method) 50% or more.
5. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
6. Power input values are based on conditions of rated external static pressure.
7. Refer to Electric Characteristics for the power input when the airflow rate is maximum at maximum external static pressure.
224 FXMQ-P
EDMT341410B Dimensions
2. Dimensions
FXMQ20PVE / FXMQ25PVE / FXMQ32PVE
Unit: mm
3D062541C
11
FXMQ-P 225
Dimensions EDMT341410B
FXMQ40PVE
Unit: mm
3D060160H
226 FXMQ-P
EDMT341410B Dimensions
FXMQ50PVE
Unit: mm
3D060159G
11
FXMQ-P 227
Dimensions EDMT341410B
FXMQ63PVE / FXMQ80PVE
Unit: mm
3D060161H
228 FXMQ-P
EDMT341410B Dimensions
3D060162H
11
FXMQ-P 229
Piping Diagrams EDMT341410B
3. Piping Diagrams
FXMQ20PVE / FXMQ25PVE / FXMQ32PVE / FXMQ40PVE / FXMQ50PVE / FXMQ63PVE / FXMQ80PVE /
FXMQ100PVE / FXMQ125PVE / FXMQ140PVE
C: 4D034245M
230 FXMQ-P
EDMT341410B Wiring Diagrams
4. Wiring Diagrams
FXMQ20PVE / FXMQ25PVE / FXMQ32PVE / FXMQ40PVE / FXMQ50PVE / FXMQ63PVE / FXMQ80PVE /
FXMQ100PVE / FXMQ125PVE / FXMQ140PVE
C: 3D058783F
11
FXMQ-P 231
Electric Characteristics EDMT341410B
5. Electric Characteristics
FXMQ20PVE / FXMQ25PVE / FXMQ32PVE / FXMQ40PVE / FXMQ50PVE / FXMQ63PVE / FXMQ80PVE /
FXMQ100PVE / FXMQ125PVE / FXMQ140PVE
C: 4D060439D
232 FXMQ-P
EDMT341410B Safety Devices Setting
Model FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE
Printed circuit board fuse 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A
Printed circuit board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A
(Fan driver)
Drain pump thermal fuse °C 145 145 145 145 145 145 145 145 145 145
C: 3D034597M
11
FXMQ-P 233
Capacity Tables EDMT341410B
7. Capacity Tables
7.1 Cooling Capacity for Te: 6°C
Indoor air temp.
Capacity 14°CWB 16°CWB 18°CWB 19°CWB 20°CWB 22°CWB 24°CWB
Model
indication 20°CDB 23°CDB 26°CDB 27°CDB 28°CDB 30°CDB 32°CDB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
FXMQ20PVE 20 1.5 1.5 1.8 1.8 2.1 1.9 2.2 1.9 2.2 1.9 2.3 1.8 2.3 1.8
FXMQ25PVE 25 1.9 1.8 2.3 2.0 2.6 2.3 2.8 2.3 2.8 2.2 2.9 2.1 3.0 2.2
FXMQ32PVE 32 2.4 2.1 2.9 2.4 3.4 2.7 3.6 2.8 3.6 2.7 3.7 2.7 3.8 2.6
FXMQ40PVE 40 3.0 2.9 3.6 3.4 4.2 3.8 4.5 3.8 4.6 3.7 4.7 3.5 4.8 3.6
FXMQ50PVE 50 3.8 3.6 4.5 4.1 5.2 4.5 5.6 4.6 5.7 4.5 5.8 4.3 5.9 3.6
FXMQ63PVE 63 4.8 4.2 5.7 4.9 6.6 5.4 7.1 5.5 7.2 5.4 7.4 5.3 7.5 5.2
FXMQ80PVE 80 6.1 5.3 7.2 6.1 8.4 6.9 9.0 7.0 9.1 6.9 9.3 6.6 9.5 6.6
FXMQ100PVE 100 7.6 6.4 9.0 7.3 10.5 8.3 11.2 8.5 11.3 8.4 11.6 8.1 11.9 7.8
FXMQ125PVE 125 9.4 8.0 11.3 9.2 13.1 10.3 14.0 10.5 14.2 10.4 14.5 10.1 14.9 9.7
FXMQ140PVE 140 10.8 9.0 12.9 10.4 15.0 11.7 16.0 12.0 16.2 11.9 16.6 11.5 17.0 11.3
Notes: 1. These capacity tables are for use when selecting a VRV indoor unit. The actual capacity of the VRV system depends on factors such
as the selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the
VRV system satisfies the required heat load.
2. shows rated condition.
Notes: 1. These capacity tables are for use when selecting a VRV indoor unit. The actual capacity of the VRV system depends on factors such
as the selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the
VRV system satisfies the required heat load.
2. shows rated condition.
234 FXMQ-P
EDMT341410B Fan Performances
8. Fan Performances
FXMQ20PVE / FXMQ25PVE
3D062537A
11
FXMQ-P 235
Fan Performances EDMT341410B
FXMQ32PVE
3D062538A
236 FXMQ-P
EDMT341410B Fan Performances
FXMQ40PVE
3D060456C
11
FXMQ-P 237
Fan Performances EDMT341410B
FXMQ50PVE
3D060457D
238 FXMQ-P
EDMT341410B Fan Performances
FXMQ63PVE
3D060458C
11
FXMQ-P 239
Fan Performances EDMT341410B
FXMQ80PVE
3D060459C
240 FXMQ-P
EDMT341410B Fan Performances
FXMQ100PVE
3D060460C
11
FXMQ-P 241
Fan Performances EDMT341410B
FXMQ125PVE
3D060461C
242 FXMQ-P
EDMT341410B Fan Performances
FXMQ140PVE
3D063787
11
FXMQ-P 243
Airflow Auto Adjustment Characteristics EDMT341410B
3D062539A
244 FXMQ-P
EDMT341410B Airflow Auto Adjustment Characteristics
FXMQ32PVE
3D062540A
11
FXMQ-P 245
Airflow Auto Adjustment Characteristics EDMT341410B
FXMQ40PVE
3D060577D
246 FXMQ-P
EDMT341410B Airflow Auto Adjustment Characteristics
FXMQ50PVE
3D060578D
11
FXMQ-P 247
Airflow Auto Adjustment Characteristics EDMT341410B
FXMQ63PVE
3D060579D
248 FXMQ-P
EDMT341410B Airflow Auto Adjustment Characteristics
FXMQ80PVE
3D060580D
11
FXMQ-P 249
Airflow Auto Adjustment Characteristics EDMT341410B
FXMQ100PVE
3D060581D
250 FXMQ-P
EDMT341410B Airflow Auto Adjustment Characteristics
FXMQ125PVE
3D060582D
11
FXMQ-P 251
Sound Levels EDMT341410B
4D062535
FXMQ32PVE
4D062536
252 FXMQ-P
EDMT341410B Sound Levels
FXMQ40PVE
4D060446B
11
FXMQ50PVE
4D060428B
FXMQ-P 253
Sound Levels EDMT341410B
FXMQ63PVE
4D060447B
FXMQ80PVE
4D060429B
254 FXMQ-P
EDMT341410B Sound Levels
FXMQ100PVE
4D060448B
11
FXMQ125PVE
4D060449B
FXMQ-P 255
Sound Levels EDMT341410B
FXMQ140PVE
4D063786
256 FXMQ-P
EDMT341410B Centre of Gravity
11
C: 4D060438C
FXMQ-P 257
Accessories EDMT341410B
12. Accessories
12.1 Optional Accessories (for Unit)
Model
Item
FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE
65% KAF372AA36 KAF372AA56 KAF372AA80 KAF372AA160
High efficiency filter
90% KAF373AA36 KAF373AA56 KAF373AA80 KAF373AA160
Filter chamber KDDF37AA36 KDDF37AA56 KDDF37AA80 KDDF37AA160
Long life replacement filter KAF371AA36 KAF371AA56 KAF371AA80 KAF371AA160
Long life filter chamber kit KAF375AA36 KAF375AA56 KAF375AA80 KAF375AA160
White KTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160W
Fresh
Service panel KTBJ25K36F KTBJ25K56F KTBJ25K80F KTBJ25K160F
white
Brown KTBJ25K36T KTBJ25K56T KTBJ25K80T KTBJ25K160T
Air discharge adaptor KDAJ25K36A KDAJ25K56A KDAJ25K71A KDAJ25K140A
C: 3D060443D
258 FXMQ-P
EDMT341410B
FXMQ-MA
Ceiling Mounted Duct Type
1. Specifications ......................................................................................260
2. Dimensions .........................................................................................261
3. Piping Diagrams..................................................................................262
4. Wiring Diagrams..................................................................................263
5. Electric Characteristics........................................................................264
6. Safety Devices Setting ........................................................................265
7. Capacity Tables ..................................................................................266
7.1 Cooling Capacity for Te: 6°C................................................................266
7.2 Cooling Capacity for Te: 9°C................................................................266
8. Fan Performances...............................................................................267
9. Sound Levels ......................................................................................269
10.Centre of Gravity .................................................................................270
11.Accessories.........................................................................................271
11.1 Optional Accessories (for Unit).............................................................271
11.2 Optional Accessories (for Controls)......................................................271
12
FXMQ-MA 259
Specifications EDMT341410B
1. Specifications
Ceiling mounted duct type
Model FXMQ200MAVE FXMQ250MAVE
Power supply 1 phase, 220-240/220V, 50/60Hz 1 phase, 220-240/220V, 50/60Hz
kcal/h 19,300 24,100
1 2 Cooling capacity Btu/h 76,400 95,500
kW 22.4 28.0
Casing / Colour Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 470×1,380×1,100 470×1,380×1,100
Model D13/4G2DA1×2 D13/4G2DA1×2
Type Sirocco fan Sirocco fan
Motor output ×
Number of units W 380×2 380×2
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
2. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
kcal/h=kW×860
3. External static pressure is changeable to change over the connectors inside control box, this pressure means Btu/h=kW×3412
"High static pressure-Standard". cfm=m³/min×35.3
4. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity l/s=m³/min×1000/60
method) 50% or more.
5. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. These values are normally somewhat higher
during actual operation as a result of ambient conditions.
6. Refer to Electric Characteristics for the power input.
260 FXMQ-MA
EDMT341410B Dimensions
2. Dimensions
FXMQ200MAVE / FXMQ250MAVE
Unit: mm
C: 3D038851A
12
FXMQ-MA 261
Piping Diagrams EDMT341410B
3. Piping Diagrams
FXMQ200MAVE / FXMQ250MAVE
C: 4D034245M
262 FXMQ-MA
EDMT341410B Wiring Diagrams
4. Wiring Diagrams
FXMQ200MAVE / FXMQ250MAVE
C: 3D039621E
12
FXMQ-MA 263
Electric Characteristics EDMT341410B
5. Electric Characteristics
FXMQ200MAVE / FXMQ250MAVE
4D040330B
264 FXMQ-MA
EDMT341410B Safety Devices Setting
12
FXMQ-MA 265
Capacity Tables EDMT341410B
7. Capacity Tables
7.1 Cooling Capacity for Te: 6°C
Indoor air temp.
Capacity 14°CWB 16°CWB 18°CWB 19°CWB 20°CWB 22°CWB 24°CWB
Model
indication 20°CDB 23°CDB 26°CDB 27°CDB 28°CDB 30°CDB 32°CDB
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
FXMQ200MAVE 200 15.1 13.3 18.0 14.9 21.0 16.3 22.4 16.8 23.6 17.0 24.2 16.1 24.6 15.4
FXMQ250MAVE 250 18.9 16.6 22.5 18.5 26.2 20.4 28.0 20.9 29.5 21.1 30.2 20.2 30.8 19.4
266 FXMQ-MA
EDMT341410B Fan Performances
8. Fan Performances
FXMQ200MAVE
3D035172
12
FXMQ-MA 267
Fan Performances EDMT341410B
FXMQ250MAVE
3D035173A
268 FXMQ-MA
EDMT341410B Sound Levels
9. Sound Levels
FXMQ200MAVE
4D035168
12
FXMQ250MAVE
4D035169
FXMQ-MA 269
Centre of Gravity EDMT341410B
4D035171
270 FXMQ-MA
EDMT341410B Accessories
11. Accessories
11.1 Optional Accessories (for Unit)
Model
Item
FXMQ200MAVE FXMQ250MAVE
Drain pump kit KDU30L250VE
65% KAFJ372L280
High efficiency filter
90% KAFJ373L280
Filter chamber KDJ3705L280
Long life replacement filter KAFJ371L280
C: 3D040334D
12
FXMQ-MA 271
Accessories EDMT341410B
272 FXMQ-MA