MXY SERIES
MXZ SERIES
SEZ
Unit : mm
MXY-2E20VA MXY-3A28VA
MXZ-2D53VA2
OUTDOOR UNIT
OUTDOOR UNIT
SERIES SEZ-KD25-71VAL
169 500 171
This concealed ceiling-mounted indoor unit series is compact, and fits easily into 400
Drain hole 63.2 233.1 288
17.7
rooms with lowered ceilings. Highly reliable energy-saving performance makes it Air in
31.3
Air in
16.8
a best match choice for concealed unit installations.
44
18.3
304 325
(Bolt Pitch)
344.5
Air in
360.6
396
Air in
17.5
12.3
40
Air out
17.7
Air out Drain holes
2-10x21 Oval hole 4-10 x 21 Oval hole
(Base bolt M10)
handle
240
Indoor and outdoor
connect wiring
550
39 x 27 hole
Liquid pipe B unit
66.3
51 51 51
Gas pipe connection
Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the Gas pipe
710
Liquid pipe
251.1
280
A unit
ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units Gas pipe connection C unit connection
require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.
440
B unit connection
225
360
45
302.5 170.4
10
150 500 A unit connection
Dimension 990
84
800 69
A Air inlet
B Air outlet 299 23.1 Liquid pipe
C Access door
D Ceiling surface
200 E Canvas duct
F Air filter
G Inlet grille
SEZ-KD35VAL
Wide Selection of Fan Speed and Static Pressure Level MXZ-3E68VA MXY-4A28VA
OUTDOOR UNIT OUTDOOR UNIT
Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet
various needs.
169 500 171
63.2 233.1 288
169 500 171
17.7
31.3
Air in
16.8
65.4 207.5 314
17.7
Air in
18.3
34
16.6
(Bolt Pitch)
360.6
18.3
396
Air in
(Bolt Pitch)
The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
360.6
396
12.3
Air in Drain holes
leading to increased installation possibilities.
12.3
Air out
17.7
17.7
Air out 4-10 x 21 Oval hole
(Base bolt M10)
Drain hole 3-ø33
4-10×21 Oval hole
(Foundation bolt M8)
840 30
840 30
200 30 330 13
200 25.8 330 13
27.1 27.1
Connecting
240
Indoor and outdoor
Wire Hole connect wiring 66.3
240
(39×27) 39 x 27 hole
Gas pipe
66.3 D unit connection
710
710
Liquid pipe : ø6.35(flared)1/4 C unit C unit connection
315
Gas pipe : ø9.52(flared)3/8 connection
440
4A
Liquid pipe : ø6.35(flared)1/4 B unit B unit connection
225
440
360
45
360
45
Liquid pipe : ø6.35(flared)1/4 A unit A unit connection
Gas pipe : ø9.52(flared)3/8 connection
84
Optional Optional Optional
84
23.1 299 23.1
299
Type Cooling Only / Heat Pump
Liquid pipe
Model Name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
Air Volume m3/min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0
Cooling Lo-Mid-Hi
SPL dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40
Operating Current (max.) 0.39 0.46 0.63 0.63 0.84
Demensions H×W×D mm 200 - 790 - 700 200 - 990 - 700 200 - 990 - 700 200 - 1190 - 700 200 - 1190 - 700
Weight kg 18 21 23 27 27
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88
External Static Pressure 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50
23 24
MXY
SELECTION
Choose from three types of indoor units and three types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.
MSY-GE(10-18)
PLA-RP SEZ-KD
MSY-GE(24-26)
Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Check Indoor Unit Capacity Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit
Combination selected is connectable. (Combinations not listed cannot be connected.)
If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.
13 14
Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Cooling Only
MXY
Outdoor Unit MXY-
MSY-GE10VA
Outdoor Wall-mounted
SERIES
Unit
MSY-GE18VA
MSY-GE(24-26)
MSY-GE24VA
MSY-GE26VA
PLA-RP50BA
4-way cassette
EXAMPLE SYSTEM
SEZ-KD35VAL
Ceiling-concealed
SEZ-KD50VAL
MSY-GE
PLA-RP SEZ-KD60VAL
SEZ Series
MXY-4A38VA SEZ-KD71VAL
MXY SERIES
4A38 2A/3A 3A/4A
*If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.
15 16