Fujifilm Technology Advancement

QC Program Stereotactic Biopsy


Lateral Approach Biopsy

CAD
Mobile

2003 2009 2010 2011


Dual Mode
Tomosynthesi
s
S-View Tomo Biopsy ISR (Tomo Excellent)

2013 2014 2015 2016


- New Detector
For Doctor Image Quality - 50μm Pixel
- Tomosynthesis

- I AEC
For - Dose - One hand
Radiographer - User Friendly paddle
attachment

For Women Less Pain Fit Sweet Pad

For Hospital Upgradable


Fujifilm Digital Mammography


Fujifilm Digital Mammography

 Paddle

UPGRADABLE
System Configuration

2D Basic Digital Mammography 2D

Digital Mammography 3D/


3D / Tomo Tomosynthesis

Full Package Digital Mammography


Tomo Biopsy Tomo Biopsy

2D Upgradable to
Tomo, Biopsy Artificial
Intelleogence, CEDM

Ahmad Sholahuddin Firdaus


IMAGE QUALITY
Amorphous Selenium – Direct Detector

Dose
Reduction
20%
Conventional Square Pixel FUJIFILM’s HCP

Dose
Reduction
20%
Distance between the Conventional Fujifilm’s hexagonal Pixels keeps
Square Pixels makes the signal sparse the electrical signal intensity
Low Dose & High Sensitivity, Premium IQ
Comparison between Fujifilm New and Conventional Detector
100μm 70μm 50μm

The smallest 50μm image pixel size in the market offering high resolution
mammography images
100μm 70μm 50μm

The smallest 50μm image pixel size in the market


offering high resolution mammography images
ISC: Image-based Spectrum Conversion

Improvement of Contrast!

Dose reduction
*Compared to Molybdenum exposure

Automatic
correction

Anode: W Anode: Mo
Sample image #1 14% dose reduction
Thickness 35mm compared to Mo/Rh,

・Calcification sharply defined

with ISC

Mo/Rh 28kV 1.20mGy W/Rh 28kV 1.03mGy


DYN II : Better Contrast No Saturation
DYN II: Calcification within Glandular area seen clearly
DYN II: Dense Breast Lesion Within Gland Area
seen clearly
INTELLIGENT AEC Technology developed by FUJIFILM

DENSE? MANUAL?

MAS?
FATTY?

IMPLANT?
Intelligent AEC (iAEC)`

• Determines composition of
breast

• Optimizes dose for all breast


types.

• AEC over entire detector 


not affected by patient
positioning

• OK for breasts with implant


Conventional AEC FUJIFILM’s iAEC
WOMEN CARE
Fit Sweet Paddle fits to the shape of the
breast, allowing pressure to be evenly applied
while holding the breast and ensuring the
breast tissue is adequately separated.

Normal Paddle Fit Sweet Paddle


Tomosynthesis Solution
Low Dose High Res.
Best for Best for
Screening Diagnosis
Standard Mode (+/- 7.5°) High Resolution Mode (+/- 20°)

15° 40°

Depth Resolution

Depth Resolution
Low Dose High Res.
Best for Best for
Screening Diagnosis
Standard Mode (+/- 7.5°) High Resolution Mode (+/- 20°)

15° 40°

Depth Resolution

Depth Resolution
• Standard ST
• High resolution HR
• Fast & Low dose!
• Wider angle (±20°) allows for thinner
• Small angle (±7.5°)
slices
• Fast acquisition and readout
• Separates fine structures for detailed
• Good for assessment of calcification
assessment of breast architecture and
clusters and general assessment of
volumetric display.
breast architecture
2D Image ST mode (15°) HR mode (40°)
Klinik MedicElle Surabaya, Jawa Timur

Mandaya Royal Hospital DKI Jakarta

RS Grand Mitra Medika Medan, Sumatera Utara

RS Pertamina Pusat RS Pertamina Pusat DKI Jakarta

RSUD Kanuyoso Balikpapan, Kalimantan Timur

RSUD AM Parikesit Kutai, Kalimantan Timur

RSUD KMRT Wongsonegoro Semarang, Jawa Tengah

RSUD Lukmonohadi Kudus Kudus, Jawa Tengah

RSUD Kota Dumai Dumai, Riau

RSUD Moewardi Solo Solo, Jawa Tengah

RSUD Kanjuruhan Malang, Jawa Timur


RS Mandaya Royal Hospital
RSUD Tarutung Tapanuli Utara, Sumatera Utara

RSUD Dr. Sobirin Musirawas, Sumatera Selatan

RSUD Dr. Soekardjo Tasikmalaya, Jawa Barat

RSUD Labuang Baji Makassar Makassar, Sulawesi Selatan

RSUD Sayang Cianjur Cianjur, Jawa Barar

RSUD Mangusada Badung Badung, Bali

RSUD Komodo Labuhan Bajo Labuan Bajo, NTT


RSUD dr Moewardi
RSUD Cibinong Cibinong
AMULET Innovality

Amulet Innovality
Rp. 4.032.264.608

Ahmad Sholahuddin Firdaus


Fujifilm Digital Mammography

 Paddle

Fujifilm Digital Mammography
Summary

FUJIFILM CONFIDENTIAL
THANK YOU!