Acidizing ESP With HCL Acid
Acidizing ESP With HCL Acid
NOTE!
Use extreme care when working with acid solutions. Wear the proper personal protective
equipment (PPE). Be sure to follow all precautions and guidelines provided by the
chemical supplier.
1.) The maximum concentration of HCl to be used is 15 % and it must have a metal
inhibitor in the solution.
2.) The acid can be spotted in the pump through the tubing or down the backside
(annulus). SEE NOTE
NOTE!
Never acidize down the backside (annulus) if galvanized cable armor is used, as the acid
will attack this armor; potentially leading to fragments of the armor coming off, in the
well, and being sucked into the pump, causing it to lockup.
3.) It is recommended the pressure used to pump the acid solution not exceed 100 PSI
at the surface. If the pump is completely plugged and would have to be pulled
anyway, if it can’t be cleaned up, some customers have applied a higher pressure.
If this is the selected approach the pressure applied at the surface should be
calculated, as follows, to obtain housing burst pressure of the pump series you are
acidizing. The calculation is as follows:
4.) Allow the acid to remain downhole for the amount of time specified by the
chemical company. If a time is not specified allow a minimum of thirty minutes
and a maximum of four hours. We do not recommend exposing the esp
equipment longer than 4 hours.
5.) When treating down the tubing, flush the spent acid from the pump by pumping
filtered water or produced fluid down the tubing. The volume of flushing fluid
should exceed the volume of acid solution by at least 10%.
6.) Some customers flush the spent acid from the pump by isolating the surface flow
line check valve. Then, remove the flapper from the check valve. After replacing
the check valve cover, the flow line valves are opened to allow produced fluid to
flow back down the tubing for the amount of time required to spot at least 10%
more produced fluid than the amount of acid pumped downhole.
7.) When the flushing fluid in the tubing string has equalized with the annulus fluid
level it is OK to start the unit. Before starting the unit, it is recommended that the
unit be check to determine if it is back spinning.
If there is any question as to the length of time it will take to reach equalization,
wait a minimum of 30 minutes.
NOTE !
Follow all electrical safety precautions when disconnecting/reconnecting the cable at
junction box.
Rev. C
6-28-01