SPECIFICATIONS

01. ALL SANITARY WORKS INCLUDE HEREIN SHALL BE EXECUTED ACCORDING TO THE 05. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED FLOOR AND WALL
PROVISIONS OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES, THE NATIONAL OPENINGS.
BUILDING CODE OF THE PHILIPPINES, AND ITS IMPLEMENTING RULES AND REGULATIONS.
06. ALL SLOPE FOR HORIZONTAL DRAINAGE SHALL BE MAINTAIN 1% AS MINIMUM, UNLESS
02. COORDINATE WITH THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS. OTHERWISE NOTED.
THE ARCHITECT AND/OR ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY
FOUND HEREIN. HIS/HER SHALL BE FINAL. 07. SIZE OF WATER SUPPLY PIPES TO THE FIXTURES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
03. ALL PIPES SHALL BE INSTALLED AS INDICATED. ANY RELOCATION REQUIRED FOR
PROPER EXECUTION OF OTHER TRADES SHALL BE WITH APPROVAL OF THE ARCHITECT 08. ALL FIXTURES SHALL BE VENTED, UNLESS OTHERWISE NOTED.
AND / OR ENGINEER.
09. THE WORK THROUGHOUT SHALL BE EXECUTED IN THE BEST AND MOST THOROUGH
04. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH MANNER KNOWN TO THE TRADE AND TO THE S SATISFACTION OF THE ARCHITECT
AND INVERT ELEVATION OF EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE AND / OR ENGINEER.
CONTRACTOR. 10. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE AND C ORDINATE
THE WORKS WITH THE SEWER EFFLUENT DISPOSAL AND WATERLINE SERVICE
CONNECTING POINT.
11. REFER TO TECHNICAL SPECIFICATION FOR DETAILED MATERIAL AND EQUIPMENT
SPECIFICATIONS.

1 2 3 1 2 3 1 2 3

MANHOLE

0.50m.x0.50m. ST MANHOLE

0.50m.x0.50m. ST MANHOLE

0.50m.x0.50m.

SERVICE AREA
CB CB

A DS A BEDROOM 3 A DS

CB

BEDROOM 1 BEDROOM 2
KITCHEN R 10mm Ø RSB
SP. AS SHOWN

CO CO
NOOK LAV FD LAV
WC FD SD
WC

T&B SD T&B DS
B CB DS
B B
25mm Ø DRAIN HOLES
FAMILY HALL SP. AT 0.075m. O.C. B.W.

12mm Ø LIFTING HANDLE


DINING AREA ROOF DECK ON CONCRETE COVER
LANAI FD LAV
CO
FD SD

DS WC
T&B
CB
DS 4" THK. CONCRETE
C C C

VARIABLE (0.30m. MIN.)


HOLLOW BLOCK W/
LIVING AREA
10mm Ø HORIZONTAL
ENTRY PORCH BALCONY MASTER BEDROOM & VERTICAL BARS

DS FD DS
D CB
D D

0.10
0.10m. THK. CONCRETE
CB
SLAB W/ 4-12mm Ø RSB
BOTHWAYS

0.10 0.10
0.10m. THK. COMPACTED
GRAVEL

TO STORM
SEWER

CATCH BASIN DETAIL


GROUND FLOOR PLAN SECOND FLOOR PLAN ROOF DECK SCALE 1:15 MTS.
SCALE 1:100 MTS. SCALE 1:100 MTS. SCALE 1:100 MTS.

SEWER LINE LAYOUT


SCALE 1:100 MTS.

DESIGNER: CIVIL ENGINEER: PROJECT TITLE: OWNER: SHEET CONTENTS: REVISIONS: CAD BY: SHEET NO.:
CORVERA,JP.
cross axis MASTER PLUMBER
PROPOSED TWO (3) STOREY
RESIDENTIAL BUILDING
CECILE T. ANDALIS
APPROVED
AS SHOWN CHECKED:
bartluce
P-1
ENGINEERING SERVICES & CONSTRUCTION
2nd Floor, Magistrado - Estrada Building
Highway - 1, San Miguel, Iriga City
Mobile Nos. 0918-4592510; 0905-2362749
E-mail Add.: bartlucena@yahoo.com
PRC NO.

2705
TIN

903-168-585
PTR

2757015
ISSUED ON

JAN. 9, 2019
ISSUED AT

IRIGA CITY
LOCATION: ADDRESS: DATE: 1 3
SAN MIGUEL, IRIGA CITY FRANCIA, IRIGA CITY

You might also like