8 7 6 5 4 3 2 1

F
E
D
C
B
A B Analogue output text amended A.C 10/01/2017
A First Issue A.C 23/08/2016
ISSUE REVISION INTLS. Date
The following conditions apply except where otherwise stated, Remove all burrs and sharp edges
1) Welded Steel Reservoirs 1.4) Branch Penetrations :- 2) Base Frames
1.1) Overall Dimensions :- Hole Ø ± 1mm 2.1) Overall Dimensions :- Projection DRAWN A.C 23/08/2016 TITLE Revision A Denco Lubrication Ltd a company of: -
£ 3m ± 3mm 1.5) Bolt Centres :- £ 2m ± 3mm
> 3m To < 6m ± 5mm PCD ± 0.5mm > 2m To < 4m ± 5mm
/ 6m ± 7mm Centres ± 0.5mm / 4m ± 7mm 23/08/2016
1.2) Diagonal Check Dimensions :- 1.6) Face Of Flange :- 2.2) Diagonal Check Dimensions :- Scale N/A - A3 CHECKED A.C
£ 3m ± 3mm Distance Off Tank Wall ± 3mm £ 3m ± 3mm I N T ER N ATI O N AL
> 3m To < 5m ± 8mm
Control Panel Sheet 5 of 12
> 3m To < 6m ± 5mm Out Of Alignment-Spirit... ALL DIMENSIONS IN MILLIMETRES
/ 6m ± 7mm Bubble Lines ± 3mm / 5m ± 10mm P.K XXXXXX
1.3) Branch Connections :- 1.7) Face Or Centre Lines Of Level... 3) Base Frames This drawing is private and confidential and is the property of Denco APPROVED LUBRICATION
Measured To One Side ± 3mm Gauge Nozzle Pairs :- ± 1.5mm 3.1) Pipework Termination Points :- Lubrication Ltd and must not be copied or lent without the consent of Tel: +44 (0)1432 365000 info@bijurdelimon.co.uk
Centres Of Branches ± 3mm Distance Off Tank Wall ± 3mm Position ± 5mm
Out Of Alignment ± 5mm
Denco Lubrication Ltd and must be returned with tender and/or on Drg. No. HLS 30234-05-01
TL 976/1/R0/Jan 13 3.2) Base Frames ± 2° completion of order. BOM XX
Denco Lubrication Ltd., Ramsden Road, Hereford, United Kingdom. HR2 6LR. Tel : +44(0)1432 365000 Facsimile : +44(0)1432 365001