NBCP

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 1

NBCP

CHAPTER 7

- GROUP A - RESIDENTIAL DWELLINGS


- GROUP B - RESIDENTIALS, HOTELS AND APARTMENTS
- GROUP C - EDUCATION AND RECREATION
- GROUP D – INSTITUTIONAL
- GROUP E - BUSINESS AND MERCANTILE
- GROUP F – INDUSTRIAL
- GROUP G - STORAGE AND HAZARDOUS
- GROUP H - ASSEMBLY OTHER THAN GROUP 1
- GROUP 1 - ASSEMBLY OCCUPANT LOAD 1000 OR MORE
- GROUP J – ACCESSORY
- “One-Hour Fire Resistive”
- “Two-Hour Fire-Resistive”
- “Three-Hour Fire-Resistive”
- “Four-Hour Fire-Resistive.”
- Eaves over required windows shall not less than 750 millimeters from the side and rear property lines.
- MAX HEIGHT OF BLDGS= 3m, FOR TOWERS = 6m
- EASEMENTS = 2m FROM PROPERTY LINE
- FOUNDATIONS = 250MM THICK, 600MM BELOW SURFACE
- FLOOR = 200KG PER SQ.M. ; 2ND FLOOR = 150KG PER SQ.M.
- ROOF = 120KG PER SQ.M.
- STAIRS 750MM WIDTH, 200MM RISE, 200MM RUN
- AT LEAST 1 ENTRANCE 1 EXIT

CHAPTER 8

- All buildings shall face a street or public alley or a private street which has been duly approved.
- the minimum horizontal dimension of court shall be not less than 2.00 meters.
- INNER COURT = 1.20M
- ARTIFICIAL VENTILATION = MIN. 2,40M
- FIRST STOREY = 2.70M ; 2ND STOREY = 2.40M ; SUC.. STOREYS = 2.1M
- NATURAL VENTILATION = 2.70M
- MEZZANINE FLOORS = 1.80M
- ROOM FOR HUMAN HABITATION = 6 SQ.M.
- KITCHEN = 3 SQ.M. , DIM. ATLEAST 1.50M
- T&B = 1.20 SQ.M., AT LEAST 0.90M
- SCHOOL ROOMS = 3 CU.M. WITH 1SQ.M. PER PERSON
- OFFICES = 12CU.M.
- HABITABLE ROOMS = 14 CU.M.
- No vent shaft shall have its least dimension less than 600 millimeters.

CHAPTER 9
-
CHAPTER 10
- Footings located at least 2.40 meters below grade along national roads or public highway may project not
more than 300 millimeters beyond the property line.
-
CHAPTER 11
CHAPTER12
CHAPTER 13
CHAPTER14
CHAPTER 15

You might also like