TECHNICAL DATASHEET

TITLE
Camur II Alarm

DESCRIPTION For monitoring and alarm triggering

PRODUCT IMAGE

PROTECTOR AS
Ringveien 6 solutions@protector-technology.com Managing Director: Jan Eri
NO-3409 Tranby www.protector-technology.com VAT no: NO 979 640 366
TECHNICAL DATASHEET
Camur II Alarm

1 Description
The Camur II Alarm node has four digital outputs (relay channels) that can be
used to control alarm devices. Alarms may originate from different levels of
the installation: by Project, Controller or Zone in Camur II software, or from
alarm events in the event log. In Camur II software you select the alarm source
and set the digital outputs on and off.

2 Technical Specification

Rated Load 0.5 A at 125 V AC / 1 A at 24 V DC

Rated Carry Current 2A

Max. switching voltage 125 V AC, 60 V DC

Max. switching current 1A

Max. switching power 62.5 VA, 30 W

Power in 12 … 48 V (9 … 38 mA @ 24 V)

Impedance 122 kΩ

Sampling int. ≥1s

Power
consumption Power in 12 … 48 V (9 .. .38 mA @ 24 V)

No alarm 1 alarm 2 alarms 3 alarms 4 alarms

9 mA 17 mA 24 mA 31 mA 38 mA

Dimensions box (WxHxD) 70 x 82 x 34 mm

Dimensions w/connectors 92 x 90 x 40 mm

Weight 130 g

Operating temperature & -40°C to 60°C


humidity range 0% – 95% RH non-condensing

Delivered with DIN-rail mounting clip

www.protector-technology.com - v.20191204 - page 2 / 4


TECHNICAL DATASHEET
Camur II Alarm

3 Connectors

Bus

Via left and right side quick plug bus


connector (must be ordered separately).

(+, - , H , L)

Input

Quick plug connector

C = Common

NC = Normally Closed

NO = Normally Open

SPDT = Single Pole Double Throw

4 Recording Types

The Alarm node supports recording types Monitor and Monitor Extended in
Camur II software, but will not log to make reports.

5 Annotation

HS export code: 9031 8000

Certification Marks:

www.protector-technology.com - v.20191204 - page 3 / 4


TECHNICAL DATASHEET
Camur II Alarm

6 Sample configuration

Alarm on power loss

Objective: Trigger (close) an Alarm node relay channel (digital output) both on
regular alarm events and upon power loss to the Alarm node itself.

1. Select a relay channel which is normally closed for this usage: digital
output 1 (C1-NC1) or digital output 2 (C2-NC2).
● When the system is not properly booted, or there is a power
outage on the bus, the alarm will be triggered (i.e. the relay
will close).
2. Check the Invert Output checkbox for the corresponding relay
channel (Digital output 1 or Digital output 2).

3. Select the Source of alarm events that will cause the relay channel to
close during normal operation (Zone, Controller or Project).
● Note: Only channel 1 and 2 will be suitable for this application
without having to move an internal jumper in the Alarm node.
4. Click Submit to enable the settings.

The digital output is now open until an alarm event or power loss causes it to
close.