Naked Flame
Controls
Housekeeping
Is the area free of combustible materials, well ventilated and illuminated? YES / NO
If NO, what measures have been implemented to reduce the risk to an acceptable level?
………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………
The operational area must be free of obstructions, debris or spillage that might create a trip/slip hazard
Is the area free of obstructions and the floor in good condition? YES / NO
If NO, what measures have been implemented to reduce the risk to an acceptable level?
………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………
Page 1 of 3
MED RISK
Suitable fire Extinguishers should be available for immediate use at site operation
1 Safety equipment must be used at all times of operation including, heat proof gloves and eye
protection.
2 Before proceeding please check the correct LPG gas bottle is being is used. Must use
either Propane(red), or Butane(blue), Propane is the recommended gas for this operation.
Also check the gas bottle outlet is clean.
3 Connect regulator to gas bottle outlet and gas hose to the other end of regulator, making sure
hose is not tangled and free from obstruction, connect other end of the gas hose to the shrink
gun, tighten using correct size spanners(both hose ends are BSP left hand thread).
4 The Hose and all connections must be checked with either a leak detection aerosol spray or
soapy water.
5 Point the shrink gun towards the floor and squeeze trigger to ignite shrink gun, release trigger to
make sure the dead mans handle is working, the shrink gun should immediately switch off.
Method Of Operation:
1 Prime system by turning the gas bottle supply on, press the red safety valve on the regulator for
3-5 seconds.
3 Never look in burner opening when shrink gun is connected to gas bottle.
4 Always make sure gas hose is either beside or ideally behind operative, never directly in front
of where shrink gun is being operated.
5 Point the shrink gun towards a clear area of the floor and squeeze the trigger slowly. It is
possible that the shrink gun will ignite with only one small squeeze of the trigger, especially
if it is warm and the operator has had a small amount of practice.
Page 2 of 3
MED RISK
2 Never lay shrink gun on floor, always hang the shrink gun up using the eyelet at the rear end of