MODEL

EMT1121U

ENGINEERING CODE COOLING CAPACITY

872AA67 272 W (LBP)

APPROVED REFRIGERANT EFFICIENCY

R-290 1.56 W/W (LBP)

POWER SUPPLY MOTOR TYPE

220-240 V 50 Hz RSCR

STANDARD CONDITIONS STARTING TORQUE


ASHRAE LST
APPROVALS
APPLICATION

LBP

DATA

General Data
Type Hermetic reciprocating

Technology Type On-Off

Displacement 5.56 cm³

Compressor Cooling Static/NotControled/220

Expansion Device Capillary Tube

Horse Power 1/3 hp

Power Supply 220-240 V 50 Hz

Evaporating Temperature Range -40 °C to -10 °C

Electrical Data
Motor type RSCR

Starting Torque LST

Mechanical Data
Oil Charge 180 ml

Oil Type Configuration ESTER

Oil Type Viscosity ISO22

Weight 7.8 Kg
Electrical Components
Description

Run Capacitor 5

Starting Device PTC | V230

Motor Protection T0933/07

External Characteristics
Tray Holder Yes

Connector Internal Diameter Shape

Suction 6.1 mm Slanted 42?/Copper

Discharge 4.94 mm Straight/Copper

Process 6.1 mm Slanted 42?/Copper

PERFORMANCE

Rated Points
Condensing Evaporating Cooling Power Gas Flow
Current Efficiency
Temperature Temperature Capacity Consumption Rate

54.40°C -23.30°C 272 W 174 W 0.87 A 2.76 kg/h 1.56 W/W

Test Condition: ASHRAELBP32, Static/NotControled/220, Return Gas 32.2°C, Evaporation -23.30°C, Condensing 54.40°C, Ambient 32.2°C , Liquid 32.2°C, Subcooling 22.2K. Data in accordance to EN

12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.

Performance Curve Data

Condensing Temperature 35°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-40 133 112 0.63 1.34 1.18

-35 175 125 0.68 1.77 1.4

-30 225 137 0.73 2.27 1.64

-25 282 149 0.78 2.86 1.9

-20 348 160 0.82 3.54 2.17

-15 422 171 0.87 4.31 2.47

-10 504 180 0.93 5.17 2.8

Test Condition: ASHRAELBP32, Static/NotControled/220, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.
Condensing Temperature 45°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-40 121 113 0.63 1.22 1.07

-35 162 129 0.69 1.63 1.26

-30 210 144 0.75 2.13 1.46

-25 267 159 0.81 2.71 1.68

-20 332 174 0.87 3.38 1.9

-15 406 190 0.94 4.15 2.14

-10 488 205 1 5.01 2.39

Test Condition: ASHRAELBP32, Static/NotControled/220, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Condensing Temperature 55°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-40 109 116 0.63 1.10 0.94

-35 148 132 0.7 1.50 1.12

-30 195 149 0.77 1.98 1.31

-25 251 167 0.85 2.55 1.5

-20 315 186 0.93 3.21 1.7

-15 388 205 1.01 3.96 1.9

-10 470 224 1.09 4.82 2.1

Test Condition: ASHRAELBP32, Static/NotControled/220, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Operating Envelope
External Dimensions

Wiring Diagram