Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SLA

SLA Battery Range

FIAMM.COM
F I A M M S L A R A N G E O F VA LV E R E G U L AT E D B AT T E R I E S
H A S B E E N D E S I G N E D F O R A P P L I C AT I O N S D E M A N D I N G
M A I N A P P L I C AT I O N S :

T H E H I G H E S T L E V E L O F R E L I A B I L I T Y A N D S E C U R I T Y.

FIAMM HIGH INTEGRITY SLA RANGE HAS BEEN DESIGNED


FOR THE MOST CRITICAL APPLICATIONS, OFFERING
T E LE COMMU NI CAT I O N
UNSURPASSED PROVEN RELIABILITY, COMPLIANT WITH
THE HIGHEST RECOGNISED INTERNATIONAL STANDARDS.
SLA USES VRLA TECHNOLOGY WITH 99% INTERNAL
RECOMBINATION EFFICIENCY, IS NON-SPILLABLE AND
MAINTENANCE FREE THEREFORE REQUIRES NO TOPPING
UP OF ELECTROLYTE DURING ITS FLOAT- LIFE. SLA
RANGE IS NON-HAZARDOUS FOR AIR/SEA/RAIL/ROAD U PS & D ATA CE NT ER
TRANSPORTATION AND IS 100% RECYCLABLE. SLA HAS
A SELF-DISCHARGE RATE LESS THAN 2% PER MONTH,
GUARANTEEING LONG SHELF-LIFE.

U T I LI T I E S & I ND U STRY

RAI LWAY S

OI L & GAS

SPECIFICATIONS
Special lead calcium tin alloy grid is designed to meet the demanding requirements of telecom and power generation markets

VRLA AGM technology using low resistance high microporous fiberglass separators

Leak resistant post seal, threaded female M6/M8/M10 terminals with high conductivity and maximum torque resistance

One-way safety relief valves allow gas to escape and prevent the ingress of oxygen.
Flame arrestors prevent sparks or flames entering the battery

Flame retardant ABS plastic to IEC 707 FV0 and UL94 FV0 (LOI greater than 28%)

Thick walled plastics designed for superior mechanical strength

Heat sealed box to lid weld for superior integrity

Installation in any orientation (excluding permanently inverted)


TECHNOLOGY
FIAMM SLA RANGE USE
Internal Strap AGM (ABSORBED GLASS
M AT ) T E C H N O L O G Y. THE
Terminal Pillar E L E C T R O LY T E I S A B S O R B E D
I N F I B E R G L A S S S E PA R AT O R S
WITH 99% INTERNAL
Separators GAS R E C O M B I N AT I O N
E F F I C I E N C Y. BLOCS ARE
GRANTS NON-SPILLABLE
AND MAINTENANCE FREE
THEREFORE REQUIRES
NO TOPPING UP OF
E L E C T R O LY T E DURING ITS
Negative Flat Plate WHOLE LIFE. LOW SELF-
The image is for illustrative purposes only. DISCHARGE ALLOWS 6
MONTHS SHELF LIFE.

SHORT CIRCUIT INTERNAL


NOMINAL CAPACITY AT 20°C TYPICAL
BATTERY CURRENT RESISTANCE DIMENSIONS (mm)
VOLTAGE (Ah) WEIGHT
TYPE (A) (mOhm)
(V) (kg)
10 HRS TO 1.8 VPC IEC 60896 21-22 IEC 60896 21-22 Length Width Height

12 SLA 50 L 12 50 1550 8.3 261 174 217 21

12 SLA 80 L 12 80 2144 6.0 302 174 217 29

12 SLA 110 L 12 110 3000 4.2 379 174 217 37

6 SLA 130 L 6 130 4200 1.55 208 174 245 23

6 SLA 180 L 6 180 4000 1.56 308 174 219 30

6 SLA 200 L 6 200 4600 1.35 308 174 245 36

2 SLA 260 L 2 260 3400 0.63 208 174 219 16

2 SLA 340 L 2 340 7900 0.25 208 174 219 21

2 SLA 430 L 2 430 9300 0.19 208 174 245 25

2 SLA 540 L 2 540 10600 0.20 308 174 219 31

2 SLA 620 L 2 620 14500 0.14 308 174 245 36

2 SLA 800** 2 820 9700 0.206 254 210 495 59

2 SLA 1000** 2 1025 12000 0.165 254 210 495 72

2 SLA 1500** 2 1500 16000 0.125 275 210 660 105

2 SLA 2000** 2 2000 20000 0.102 368 218 660 137

** this cell must be installed horizontally

ELECTRICAL CHARACTERISTICS STANDARDS


Float Voltage: 2.27 V/cell at 20°C IEC 60896 Part 21 - VRLA methods of testing
Boost Voltage: 2.40 V/cell IEC 60896 Part 22 - VRLA requirements
Telcordia GR-4228 - VRLA battery string certification
Float Voltage Compensation with Temperature: -2.5 mV/cell/°C
BS 6334 / UL 94 V0 / IEC 707 FV0 materials flammability
Self-Discharge at 20°C: <2%/month Bellcore TR-NWT-000766 - VRLA battery generic requirements
Eurobat “>12 years VERY LONG LIFE”

FIAMM Energy Techology reserves the right to change or revise without notice any information or detail given in this publication SLA Battery Range_2020_12
CERTIFICATIONS ACCESSORIES
ISO 9001 RVS
Quality Management System (remote venting system) for IP rated applications
which require remote gassing
ISO 14001
Environmental Management System Rack for battery installation
(standard and anti-seismic)
ISO 45001
Workplace Safety & Health Cabinets for battery installation
(including electrical protections and disconnection)

Battery monitoring systems

DISCHARGE CURVES at different current / final voltage (at 20°C)

2.2

2.1
Battery Voltage (V/cell)

2.0

1.9

1.8
0.10 C

1.7 0.37 C
0.50 C
1.0 C
1.6 1.5 C

1.5
1 10 100 1.000 10.000
Discharge time (min)
The above discharge curves are typical. For more detailed information please see the specific product sheets.

TYPICAL CHARGE CURVES STORAGE


Battery Voltage and Charge Time for Standby Use (at 20°C) Capacity loss during storage at various temperatures
[A] [V/Cell] [%]
2.4 140 100
Charging Current

Charging Voltage

The battery can be


2.2 120 used without
refreshing charge

Remaining Capacity (%)


2.0 100 90
Recharged Capacity

Refreshing charge at
2.4 Vpc for 24 hours
1.8 80 (at 20-25°C) must be
applied as soon as
possible
1.6 60 80
0.10 C10 5°C
Refreshing charge of
40 2.4 Vpc may be
insufficient to recover 20°C
0.05 C10 the battery capacity. 30°C
40°C
20 It is important to 70
avoid this area <80%

0 0 0
0 5 10 15 20 [hours] 0 2 4 6 8 10 12
Storage Time (months)
Voltage 100% Recharged 100% Current 100%
50% Capacity 50% 50%

FIAMM Asia Pacific PTE LTD infostandby.asia@fiamm.com


www.fiamm.com
21 Toh Guan Road East, #09-08
608609 Singapore - Republic of Singapore in linkedin.com/company/fiammenergytechnology
Tel. +65 68676150 youtube.com/user/FIAMMvideo
Fax +65 68626550 fiamm.batteries
fiammbatteries

You might also like