Final Calibration

Date-Time: 10/15/22 13:21 Analysis Time: 230 Cycle Time: 250


Stream: 1 stream 2 MODE: FCAL Cycle Start Time: 13:17
Analyzer: UK22U1405 Strm Seq:2
Company: Daniel Industries

Component Cal Old RF New RF * RF % Old RT New RT * RT %


Name Conc. DEV. DEV.
C6+ 50/50/00 0.04508 1.37862e+7 1.48658e+7 * 7.83 34.3 34.5 * 0.58
PROPANE 0.80300 7.94065e+6 8.4606e+006 * 6.55 46.8 46.8 * 0.00
i-BUTANE 0.10042 9.08106e+6 9.95489e+6 * 9.62 61.3 61.3 * 0.08
n-BUTANE 0.10030 1.11604e+7 1.04413e+7 * -6.44 74.4 70.7 * -4.91
NEOPENTANE 0.05002 58954.76563 67071.39844 * 13.77 79.5 79.8 * 0.38
i-PENTANE 0.05020 54316.36719 51017.08594 * -6.07 111.2 106.6 * -4.14
n-PENTANE 0.05005 50152.54297 47828.50000 * -4.63 126.1 121.3 * -3.85
NITROGEN 3.02860 2.71022e+6 5.82762e+6 *115.02 147.7 148.3 * 0.44
METHANE 90.13300 4.01924e+6 4.48124e+6 * 11.49 154.2 152.8 * -0.88
CARBON DIOXIDE 0.60230 5.84739e+6 6.60486e+6 * 12.95 186.6 185.8 * -0.43
ETHANE 5.03700 6.49411e+6 7.40905e+6 * 14.09 212.1 211.3 * -0.38

ACTIVE ALARMS
None

file://C:\GC\SAVE\tmprpt01.txt 2/11/2023