RFI - TS145 - 3 PJTS-30-R0-Coating System For Tower Section
G1002_F08_IN
Form Version: 1.0
Confidentiality: IP
Request for Information Status:released
Anfrage für Informationen
1) For roughness profile after blasting, NX's req. is from 50-70μm acc. to F302_043_EN (p.g 4/12). It 's too strict. We will spend a lot of time/
cost for reaching this req. According to ISO 8503- 2 class Medium (G), it is only 50-85μm.
2) For free paint are at around flange hole/the washer bearing surface, the flange hole diameter of top flange is ø23, but in page 32/40 of
Lieferanten Kommentar
Supplier Comment
NALL02_004536 R21), it doesn't specify outside dia. of spare cap for bore hole diameter ø23.
3) For coating system, our JOTUN supplier highly recommend coating system as below according to. NALL02-004536 V21(p.g 30/40) - -
Interior tower: JOTACOTE UNIVERSAL RAL 9001: 200μm
- Exterior tower: 1st coat: JOTACOTE UNIVERSAL RAL 9001: 190μm, Top coat: HARDTOP FLEXI RAL 7035: 50μm
4) For gloss of surface after painting , NX's requirement is 50-70 for both inside and outside according to NALL01_004539_EN_R04 (p.g
5/12). This requirement is not suitable with JOTUN's recommendation coating system as item 4.
Suggestions / Vorschläge:
Lieferanten Empfehlung
Supplier Suggestion
29.04. NNU
To 1) roughness of 50-85µm is accepted.
to 2) the Min. Diameter of the cover for M20: 39mm and Max. Diameter of the cover for M20: 40mm
to 3) The paint system can be approved. PLease send me the C3/C4 test certificates of the system
to 4) Gloss should be 50-70 as per specification.