Category Type EEF-Pump Saving % Cost(T-AED) per pump

AODDP 10% 30

AODDP Elect-DDP 15% 50

Peristaltic Pump 15% 60


PD Pump

Gear Prograssive Cavity 10% 60

Prograssive Cavity - - -

Centrifugal Monoblock pump 10% 18

Rotary Pump Monoblock pump

Centrifugal Coupled pump 15% 25

Note:
- These are estimated savings and will vary case to case depending upon pump installation layout, application/fluid, NPSH, cha
- These are estimated cost of per unit pump based on experience and past purchases of similar pumps
Assumptions

Flow and pressure requirement known


Optimization of Compressed air pressure and volume based on required output
Material seleciton from Metal to Plastic depending upon fluid characteristics
Use of dampener for uniform continuous flow

Replaces compressed air for electrical motor


Variable speed control for uniform but pulsuating flow
Electric motor driven pump with out seal and less friction
Use of dampener for uniform contineous flow

Required flow and pressure requirement known - For uniform flow


Fluid chracteristics (Density, Solids %, PH, Viscosity) known - Hazardous Chemicals
Electric motor driven pump with out seal and less friction
Variable control drive

Required flow and pressure requirement known - For uniform flow


Fluid chracteristics (Density, Solids %, PH, Viscosity) known - Hazardous Chemicals
BEP against flow and pressure required for each pump know - Characteristic curve
Gear pitch selection
Variable speed drive with gearbox

Required flow and pressure requirement known - For uniform flow


Fluid chracteristics (Density, Solids %, PH, Viscosity) known - Hazardous Chemicals
BEP against flow and pressure required for each pump know - Characteristic curve
Screw pitch selection
Variable speed drive with gearbox

Flow and pressure requirement known - For uniform flow


Fluid chracteristics (Density, Solids %, PH, Viscosity) known - Nonhazardous chemicals
BEP against flow and pressure required for each pump know - Characteristic curve
Correct Impeller Size
Select EEF Class 1 motor

Required flow and pressure requirement known - For uniform flow


Fluid chracteristics (Density, Solids %, PH, Viscosity) known - Hazardous Chemicals
BEP against flow and pressure required for each pump know - Characteristic curve
Correct Impeller Size
Select EEF Class 1 motor

out, application/fluid, NPSH, characteristic curve, motor type, Hazard zone, Environment