Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

CHECKLIST FOR PLUMBING

(EXTERNAL WORKS)
Project Rajyash Regius

Client Rayash Procon LLP

PMC JLL

Contractor Ramya Projects


Date of Inspection:
RFI No:

Ref.Drg.No.

Location:

S.NO. Description YES NO Remarks

PRE-EXECUTION CHECKS
1 Have all the sewer pipes, traps and other fittings free from cracks,
holes and burrs etc., and is checked before being put into use?

CHECKS DURING EXECUTION


1 Is the bottom of gully’s/channels laid in slope at inlet to outlet of
chambers and finished smooth?

POST-EXECUTION CHECKS
1 Are the spacing of inspection chambers and manholes such that
cleaning of sewer lines can be done easily?
2 Are the inlets and outlets of chambers and manholes plugged during
progress of the work?
3 Has it been ensured that gully’s/channels of inspection
chambers/manholes have been given a smooth curve if sewer lines
are intersecting at right angles?
4 Have the joints of sewer pipes been plugged with cotton yarn (packing
rassi) before applying cement slurry over joints?

Corrective action, if any:

Approved With
Approved Not Approved
Comments
Contractor JLL Client
Name: Name: Name:
Sign: Sign: Sign:
Date: Date: Date: