Waterproof Pocket Water Quality Meters

Agriculture Aquaculture Arts Food & Health Livestock Manufacturing Water &
Beverage Management Wastewater

A
ARR NT
MADE IN
W

2 YEAR
Y

AR T
JAPA N
Y
W

RAN

www.horiba-laqua.com
Applications
pH, ORP, Ion, Salt, TDS, and Conductivity Pocket Meters

Determination
of Nutrient
Concentrations in Soil
Solution and Tomato
pH and Plant Sap Conductivity and
Conductivity Fertigation management requires
rapid and accurate methods to
Elephant’s Foot
Measurements determine nutrient concentrations Testing
in Coconut Coir in soil solution and plant sap.
Substrate Folegatti et al (2005) found that the
concentrations of NO3-, K+, and Na+ Measurement of pH Elephant’s foot is a physiological
disorder in sweet pepper
Coconut coir testing involves
extracting a sample solution with
in soil solution and tomato plant
sap determined by LAQUAtwin
in Plant Tissue (Capsicum annuum L.), where the
base of the plant’s stem becomes
distilled water and measuring the ion pocket meters showed good An optimal pH value of 6.4 in plant swollen below the cotyledon level
pH and conductivity of the extract. correlations with those obtained tissue will encourage healthy and wounds develop at the base
The acceptable conductivity in soil solution and in leaf dry growth and prevent insects and of the stem’s epidermis because
ranges for 1:2 (v/v) dilution and matter, respectively, determined diseases attacking the plant. To of salt accumulation. LAQUAtwin
pour thru sampling methods are by standard methods in laboratory, measure pH, squeeze the sap conductivity meter can be
0.26-0.75 mS/cm Scan QR Code for link and concluded that Scan QR Code for link of mature leaves Scan QR Code for link used to measure Scan QR Code for link
and 1.0-2.6 mS/ LAQUAtwin ion with garlic press conductivity of soil
cm, respectively. pocket meters are and place the sap and help farmers
The ideal pH range useful low-cost onto the sensor choose the best
is 5.4-6.2 for both tools in fertigation of LAQUAtwin pH land to grow sweet
methods. management. meter. pepper crops.

Soil Nitrate
Measurement for Soil Salinity
Soil pH and Nutrient Impact of Soil
Determination of Measurement in
Availability Salinity on Sugar
Plant-Available Almond Orchard
The desirable soil pH range for
Nitrogen Cane Yield
optimum plant growth varies Crops have different levels of
among crops. Generally, soil pH tolerance to salinity. Testing soil Soil salinity adversely affects the
Nitrate concentration in soil is a salinity is the best way to check growth of sugar cane crops. To
6.0-7.5 is acceptable for most good indicator of available nitrogen
plants as most nutrients become soil condition in the orchard before help optimize sugar cane yield,
to plants. The required soil nitrate- salt damage occurs. The EC1:5 test check the sodium content in soil
available in this pH range. Soil pH nitrogen (NO3-N) for
can be determined Scan QR Code for link is used to estimate Scan QR Code for link by mixing it with Scan QR Code for link
specific crops varies Scan QR Code for link soil salinity (ECe). water in 1:5 ratio
by mixing soil from crop to crop
sample with water The soil salinity and measuring the
but in general, a threshold value for resulting solution
and then measuring concentration range
the resulting almond is 1.5 mS/ with LAQUAtwin
of 10-50 mg/kg is cm. sodium ion meter.
aqueous solution. desired.

| 01
Potassium
Determination in
Measurement of Plant Tissue
Comparison of LAQUAtwin
Potassium in Soil Potassium Ion Meter and ICP
Spectrometry Trials revealed
In laboratories, potassium in soil
close significant correlation (r Measurement of
Measurement of is extracted with 1M ammonium
values were 0.80 and 0.93 for first
acetate and analyzed with Atomic
and second trials, respectively) Potassium in Rice
Calcium in Soil Absorption (AA) or Inductivity
Coupled Plasma-Optical Emission between the LAQUAtwin potassium Potassium is one of the essential
Calcium is one of the essential Spectrometry (ICP-OES). ion meter readings and ICP results plant nutrients supplied via fertilizer
nutrients taken up by plants from LAQUAtwin potassium ion meter obtained from plant’s fresh petiole in most irrigated rice fields.
soil for cell wall development. To showed values higher than those sap and dried tissue, respectively. Extracting sap from the lower
measure calcium concentration in of ICP-OES. However, with 0.01M This suggested that LAQUAtwin stem of plant rice and analysing it
soil, extraction with 1M ammonium ammonium acetate extraction, potassium ion meter could be with LAQUAtwin potassium meter
acetate and filtration Scan QR Code for link good correlation Scan QR Code for link an appealing provide indication Scan QR Code for link
should be performed (r=0.981, r2=0.962) field method Scan QR Code for link of the current
prior to placing was obtained substitute for rapid potassium status
the filtrate onto between ICP-OES determination and help farmers
the flat sensor of and LAQUAtwin of potassium adjust the fertilizer
LAQUAtwin calcium potassium ion concentration in application.
ion meter. meter. plants.

Quick Nutrient
Analysis in pH and Conductivity
Strawberry for Testing Acrylic
Production Paint Films and
Rapid In-Field Paper Supports
Determination of Regular monitoring of nutrient levels
such as nitrate (NO3-), potassium and Formulating
Nitrogen in Onions (K+) and calcium (Ca 2+) in plant Aqueous Cleaning
Fresh root sap analysis with
Nitrate Measurement petioles, soil solution, irrigation
water, and drain water produces Solutions
LAQUAtwin nitrate ion meter offers in Turf Grass not only good yield and fruit quality,
but also reduces fertilizer cost and Isotonic aqueous cleaning solutions
cost-effective, rapid, and easy that match the pH and conductivity
solution to determine nitrogen mitigates environmental hazards.
Nitrate concentration in grasses The LAQUAtwin pocket meters readings of acrylic paint films and
status in onion plants. The nitrate- can be used as an indicator of soil paper supports obtained from
nitrogen (NO3-N) concentrations are the perfect tools for testing
nitrogen (N) availability for their as they directly measure samples agarose gel pellets have been
in onion vary at different growth growth. Research at the University shown to be effective in reducing
stages. The Scan QR Code for link and provide results
of Connecticut Scan QR Code for link in just few seconds Scan QR Code for link or removing Scan QR Code for link
acceptable root sap suggests verdure dirt, dust, active
NO3-N concentration allowing growers
sap nitrate-N to identify and mold growth and
range for 0.5 to 1.5- concentrations at associated stains,
inch onion bulbs is correct any nutrient
200-300 ppm as the deficiency or excess tide line stains, and
350 to 500 ppm. optimum level. discoloration.
immediately.

02 |
Aquarium Water pH Measurement in
Testing the Acidification of pH Measurement to
Fermented Sausages Determine Freshness
Testing aquarium water such as pH of Brine for
freshwater and saltwater (either of Meat Products
natural or artificial seawater) with Lowering pH or increasing acidity Canned Food Testing
reliable instruments is necessary to of meat has become main hurdle Fresh meat must have a pH value
create a clean and safe environment against pathogenic bacteria in For brine of canned acid foods, in the range of 5.5 to 6.2 before
for your aquatic species. The sausage making. pH is used the equilibrium pH value must selling to consumers. LAQUAtwin
LAQUAtwin pocket Scan QR Code for link in the course of Scan QR Code for link be 4.6 or below to Scan QR Code for link pH meter provides Scan QR Code for link
meters require only fermentation process inhibit the growth a simple and cost
few drops of water in order to produce of Clostridium effective way to
and deliver the microbiologically botulinum, the most check the freshness
results in just few stable product that heat resistant of of meat in the local
seconds. has a pH value of 5.3 the food pathogen markets.
or less. microorganisms.

Determination of
pH Measurement Sodium Content in
to Determine pH Measurement of Food Samples Sodium Value Check
Acidification of Sushi Pickled Fruits and Foods contain varying amounts of for Canned Food
Rice Vegetables salt (NaCl), which has 40% sodium.
Determining the sodium content
There is a growing concern on
canned foods with large sodium
The rice used for sushi must be in foods accurately reduces the
Pickling is a process of preserving content as excessive intake of
acidified with acetic acid (vinegar) health risks associated with it.
fruits and vegetables in brine, oil, sodium can cause high blood
to pH less than 4.6 to inhibit the The American Heart Association
water or vinegar. The Australia pressure and hypertension. To
growth of pathogenic bacteria. To recommends consumption of less
New Zealand Food check the sodium content in canned
measure pH, simply Scan QR Code for link than 1500 mg/day
Standard Code Scan QR Code for link food, dilute a sample Scan QR Code for link
place a sample of sodium for most Scan QR Code for link
2.3.1 requires the with DI water in 1:5
rice mixture onto American adults,
preserved fruits and ratio, then place the
the flat sensor of which is the level
vegetables to have resulting solution
LAQUAtwin pH with the greatest
a pH not greater onto the LAQUAtwin
meter. effect on blood
than 4.6 to prevent sodium ion meter.
pressure.
botulism.

| 03
Nitrate Measurement
Measurement of Measurement of in Hybrid
Calcium in Milk and Sodium in Athlete’s Sudangrass and
Sweat Pearl Millet Hays Residual Sodium
Milk Beverages
Determining the calcium content Determining the sodium Determining the nitrate Check During Clean-
of milk and milk beverages helps concentration in sweat and
replacing that with proper
concentrations of sudangrass
and pearl millet before feeding
in-Place Process
consumers accurately gauge their
electrolyte intake prevent fluid and them to livestock prevents nitrate Caustic soda or sodium hydroxide
calcium intake. Unlike atomic
electrolyte imbalances. Sweat can toxicity. Plant sap testing with (NaOH) is the chemical commonly
absorption spectroscopy (AAS)
be easily extracted from sterile LAQUAtwin B-743 nitrate ion meter used in alkaline cleaning solution
and inductively coupled plasma
patches applied on skin and tested offers fast and accurate nitrate for clean-in-place (CIP) in process
atomic emission spectroscopy
with LAQUAtwin sodium ion in-field analysis. Generally, the plants. Measuring the sodium ion
(ICP), the LAQUAtwin calcium
meter. According maximum nitrate concentration on the
ion meter offers a
Scan QR Code for link to Gatorade Sports Scan QR Code for link c o n c e n t r a t i o n s Scan QR Code for link water rinse or swab Scan QR Code for link
simpler method of
Science Institute, considered safe for can indicate whether
measuring calcium
the sodium results all cattle are 820 residual chemical
ion-ionizing protein-
obtained with ppm and 700 ppm has been removed
bound calcium in
HORIBA falls within for sudangrass sap properly from the
sample using acid
15.4 mEq/L 95% of and pearl millet sap, process equipment.
before analysis.
the time. respectively.

Measurement of
pH of Cement for Calcium in Drinking Determination of
Floor Installation Water Potassium in Sea
Testing Measuring Salinity Water
Determining the calcium content
Fresh concrete is usually very
alkaline, above pH 11. When the of Water of drinking water helps consumers
accurately gauge their calcium
Seawater has high ionic strength. To
eliminate matrix effect in measuring
alkalinity in a concrete subfloor intake. Unlike atomic absorption potassium (K+) concentration,
is high, it can stop the floor Measuring the salinity or the spectroscopy (AAS) and inductively standard solutions made with
covering adhesive from bonding dissolved salt content of water is coupled plasma atomic emission the same background as the
properly to the concrete. Australian important as aquatic organisms, spectroscopy (ICP), the LAQUAtwin seawater sample are recommended
Standard 1884 for resilient flooring livestock, and crops thrive at calcium ion meter offers a for calibration. The result of
installation states Scan QR Code for link different salinity Scan QR Code for link simpler method of Scan QR Code for link measurement using Scan QR Code for link
the the pH level of levels. Freshwater measuring calcium the LAQUAtwin
the concrete surface has a salinity value ion - ionizing bound Potassium Ion meter
should be between of less than 0.5 ppt calcium in water is within ±10% of
9 and 10 before while seawater has using acid before typical seawater
the flooring can be an average salinity analysis. concentration.
installed. of 35 ppt.

04 |
Compact Water Quality Meter

Lab in your pocket


LAQUAtwin compact meters
are simple and easy-to-use.
Quick!
10 Water Quality Parameters: pH, ORP, No container is Variety!
Conductivity, Total Dissolved Solids (TDS), needed to calibrate Measurements can
Ions (Na+, K+, NO3-, Ca2+, F-) and Salt or measure. Only few be made in different
drops of standards positions because of
Employing the same test principle as laboratory electrodes, LAQUAtwin and samples are all the sensor design.
compact meters provide a reliable and accurate measurement. Select you need.
your meter that best suits your application from 13 colorful models.

Anyone! Wherever!
Easy & simple Solution! IP67 rated dust/
Discover more waterproof. Carry
operation
with easy, on-site LAQUAtwin and its
makes everyone
measurement. accessories in a
an expert.
carrying case.

Reliable! Cost effective


HORIBA 60 years 1/100 of standard
sensor technology solution and
sample volume is
Accurate reading from a single drop of distilled in HORIBA’s
needed. Sensor is
unique flat sensor.
sample in just a few seconds replaceable.
Incorporating the same parts as standard laboratory electrodes, the
LAQUAtwin compact meters are built with miniaturized components
and unique flat sensor chip, which is less than 1 mm thick—a result of
60 years of HORIBA’s sensor engineering technology. Carrying case comes with calibration
solutions and accessories
pH response membrane
KCI gel Everything you need for measurement is already packed in a carrying
case for portability and storage. Also, you may attach a strap or tag
Approx. 0.8 mm (not included) on the strap hole of the meter for your convenience.

Liquid junction Reference electrode Temperature sensor


Cross-sectional view of the flat pH sensor chip.

Calibrate and measure at the touch of a


button. Read the result when  appears.
Hassle-free operation with single-button calibration and measurement.
Record the reading once a smiley face appears on the display

Attach a strap or tag here.

Fully waterproof and dustproof (IP67


rated)1 with backlight display
The LAQUAtwin compact meters can be used
anywhere and anytime. No need to worry with water
splashes or inclement weather during measurement.
With the meter’s backlight display, you may view the
reading in testing sites with poor light condition.
1
Withstand immersion for 30 minutes at 1m depth. Not suitable for
underwater use.

| 05
Easy measurement for all users

Sensor
IP67 rated waterproof/dustproof. Measurement button
Sensor is easily replaceable. Press to view mV or temperature (Auto Stable mode) Strap hole
or to lock / unlock reading (Auto Hold mode). You can attach a
In Set-up mode, press to scroll or adjust settings. strap or tag here.

Meter Power button


Press to switch on or
IP67 rated
off the meter or exit
waterproof/
set-up mode.
dustproof.
Calibration button
Press to perform
calibration or save
Sensor guard settings in set-up mode.
Protects sensor from damage
and light. Sliding cap—for
scooping water samples. Open
the whole sensor guard when
placing water or solid samples
directly onto the sensor.
Backlight
For easy viewing in the
Open dark. Flashes when
battery is low.

Close

Slide cap
Battery Indicator Stability mark
Appears when Lights up when
battery is low measurement
is complete.

Calibration mark Temperature alarm


Calibration is Flashes when the
complete when it temperature is out
stops flashing. of range.

Measurement mark Measurement value Voltage


Measurement is Flashes when the measurement mode
complete when it measurement value Displays sensor voltage.
stops flashing. is out of the range.

Immersion Scoop
When you're in the lab, you Use as a scoop to test
can test the sample in a water from a river. Vertical
beaker. Ensure the sensor scoop is available with a
guard sliding cap is open. unique sensor guard.

Drops Wipe
Drop a sample with a Unique measurement The sampling sheet allows
dropper; small volumes as options with tiny, trace volumes to be
0.1 mL can be measured. analysed. For example,
Using sampling sheet B,
LAQUAtwin wipe off the surface of the
volumes down to 0.05 mL One meter provides seven flexible skin with a sampling sheet
can be tested. measurement techniques. Simply soaked with pure water
and measure.
choose the method that best fits
your sample and situation.

Solid samples Paper, textiles


Foods containing some
moisture can be tested by
and films
placing a small piece directly To test sheets of paper and
onto the sensor. textiles, cut up the sample
into small pieces and place
them directly onto the sensor
then add a defined amount of
Powders pure water.
LAQUAtwin meters can also test dry
powders. Simply place the powder
sample onto the sensor, and add an
appropriate amount of pure water. All methods applicable to pH measurement. Conductivity models cannot be tested with solids,
powders, and sheet-like samples. Above pictures are for illustration purposes only.

06 |
pH ORP

pH-11 pH-22 pH-33 ORP-11


Model
mV mV mV Temp Temp

WATER MICRO 2 PT WATER MICRO 3 PT WATER MICRO 5 PT WATER MICRO 1 PT


Features PROOF VOLUME CAL
0.1 pH
PROOF VOLUME CAL
0.01 pH
PROOF VOLUME CAL
0.01 pH
PROOF VOLUME CAL

Part No. 3999960122 3999960123 3999960124 3200965260


Measurement
Glass Electrode ORP Electrode
Principle
0.3 ml (0.05 ml with Sampling
Min. Sample 0.1 ml (0.05 ml with Sampling Sheet B)
Sheet B)
pH Range /
0.0 to 14.0 pH / 0.1 pH 0.00 to 14.00 pH / 0.01 pH –
Resolution
mV Range /
-650 to 650 mV / 1 mV -1000 to 1000 mV / 1 mV
Resolution
Accuracy ± 0.1 pH ± 0.01 pH ± 2 mV
Max.
Calibration 2 3 5 1
Points
Calibration USA: 1.68, 4.01, 7.00, 10.01 & 12.46
225 mV
Curves NIST: 1.68, 4.01, 6.86, 9.18 & 12.46
Temperature
Display / – 0 to 50.0 °C / 0.1 °C
Resolution
ORP and Eh Measurements •
Automatic Buffer Recognition Automatic Standard Recognition
Functions • Auto / Custom Calibration Value
Temperature Compensation • Temperature Calibration* • Auto Hold / Auto Stable • Automatic Power Off (30 mins.) • Low Battery Indicator
• IP67 Water / Dust proof • Replaceable Sensor
Display Custom (monochrome) digital LCD with backlight
Operating
Temperature / 5 to 40.0 °C / ≤ 85% in relative humidity (no condensation)
Humidity
Battery Life Approx. 400 hrs. continuous use without backlight
ABS epoxy body / platinum
Materials ABS epoxy body / flat glass sensor
disk sensor
Dimensions 164 x 29 x 20 mm (excluding projections)
Mass Approx. 55g (including sensor and batteries)
225 mV ORP Standard (14 ml)
Accessories pH 7.00 & 4.01 Buffers (14 ml each) • Abrasive Cotton Swab •
included Sampling Sheet B (5 pcs)
CR2032 Batteries (2 pcs) • Dropper • Instruction & Quick Manuals • Storage Case
* Applicable for models with temperature display

| 07
Conductivity (EC) Salt (NaCl)

Model EC-11 EC-22 Temp


EC-33 TDS Temp
Salt-11 Temp

WATER MICRO 2 PT ~19.9 WATER MICRO 3 PT ~199.9 WATER MICRO 3 PT ~199.9 WATER MICRO 2 PT EC
Features PROOF VOLUME CAL mS/com PROOF VOLUME CAL mS/com PROOF VOLUME CAL mS/com PROOF VOLUME CAL CONV

Part No. 3999960125 3999960126 3999960127 3999960128


Measurement
2 Electrode Bipolar AC
Principle
Min. Sample 0.12 ml
Conductivity
Conductivity
0 to 199 µS/cm (1 µS/cm) Salt
0 to 199 µS/cm (1 µS/cm)
200 to 1999 µS/cm (1 µS/cm) 0.0 to 100.0 g/L (0.1 g/L)
200 to 1999 µS/cm (1 µS/cm)
Measurement 2.00 to 19.99 mS/cm (0.01 mS/cm)
2.00 to 19.99 mS/cm (0.01 mS/cm)
Range / 20.0 to 199.9 mS/cm (0.1 mS/cm)
Resolution TDS
0.0 to 99.9 ppm (0.1 ppm) Salt
­—­
100 to 999 ppm (1 ppm) 0.00 to 10.00 % (0.01 %)
1000 to 9990 ppm (10 ppm)
± 2% full scale (0 to 19.99 mS/cm) ± 2% full scale (0.0 to 9.9 g/L)
Accuracy ± 2% full scale (for each range)
± 5% full scale (20.0 to 199.9 mS/cm) ± 4% full scale (10.0 to 100.0 g/L)
Max.
Calibration 2 3 2
Points
1413 µS/cm, 12.88 mS/cm 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
Calibration
TDS Factor (0.4 to 1.0) / NaCl / Sea water
Curves ­—
EN 27888 / 442 / NaCl
Temperature
Display / — 0 to 50.0 ºC / 0.1 ºC
Resolution
Automatic Range • Automatic Standard Recognition • Temperature Compensation (2%/ºC fixed) • Temperature Calibration* • Auto Hold
Functions
/ Auto Stable • Automatic Power Off (30 mins.) • Low Battery Indicator • IP67 Water / Dust Proof • Replaceable Sensor
Display Custom (monochrome) digital LCD with backlight
Operating
Temperature & 5 to 40 ºC, ≤ 85% in relative humidity (no condensation)
Humidity
Battery Life Approx. 400 hrs. continuous use without backlight
Material ABS epoxy body / Titanium coated with platinum black sensor
Dimensions 164 x 29 x 20 mm (excluding projections)
Mass Approx. 50g (including sensor and batteries)
0.5% & 5.0% NaCl Standard
Accessories 1413 µS/cm & 12.88 mS/cm Conductivity Standard Solutions (14 ml each)
Solutions (14 ml each)
included
Conditioning Solution (4 ml) • CR2032 Batteries (2 pcs) • Dropper • Instruction & Quick Manuals • Storage Case
*Applicable for models with temperature display

TDS Calibration Curves


Application Key chemical species TDS selection
Aquaculture, pickling NaCl NaCl
Boiler water, HVAC Na2SO4, NaHCO3, NaCl 442
Environmental EN standard for environmental water EN 27888
General application KCl TDS Factor Linear Default: 0.5 Selectable: 0.4 to 1.0

EN 27888 Curve 442 Curve NaCl Curve


12000 90000 300

80000
10000 250
70000

8000 200
TDS (mg/L)

COND / mS/cm-1

60000
TDS442 / ppm

6000 50000 150

40000
4000 100
30000

2000 20000
50

0 10000 0
0 5 10 15 20 25 0 1000 2000 3000 4000 5000 6000
0
Conductivity (mS/cm) 0 20000 40000 60000 80000 100000 NaCl / mM
Conductivity µS/cm
08 |
Sodium Ion (Na+) Potassium Ion (K+) Nitrate Ion (NO3 -) Calcium Ion (Ca2+) Fluoride Ion (F-)

Na-11 K-11 NO3-11 Ca-11 F-11


Model
Temp Temp Temp Temp Temp

WATER MICRO 2 PT WATER MICRO 2 PT WATER MICRO 2 PT WATER MICRO 2 PT WATER MICRO 2 PT
Features PROOF VOLUME CAL PROOF VOLUME CAL PROOF VOLUME CAL PROOF VOLUME CAL PROOF VOLUME CAL

Part No. 3200689159 3200689160 3200689162 3200689161 3200934412


Measurement
Ion Selective Electrode
Principle
0.3 ml (0.1 ml with
Min. Sample 0.3 ml (0.05 ml with Sampling Sheet B)
Sampling Sheet B)
NO3-: 6 to 9900 ppm
4 to 9900 ppm (mg/L)
(mg/L)
Measurement 2 to 9900 ppm (mg/L) (0.1 to 250 mmol/L) 4 to 9900 ppm (mg/L)
(0.1 to 160 mmol/L) 0.1 to 990 ppm (mg/L)
Range (0.1 to 430 mmol/L) 2 to 5000 kg/10a (soil/ (0.1 to 250 mmol/L)
NO3-N: 1.4 to 2200 ppm
water ratio 1:5)
(mg/L)
0 to 99 ppm: 1 ppm 0.1 to 9.9 ppm: 0.1 ppm
Resolution 100 to 990 ppm: 10 ppm 10 to 99 ppm: 1 ppm
1000 to 9900 ppm: 100 ppm 100 to 990 ppm: 10 ppm
Accuracy ± 10% of actual value ± 20% of actual value ± 2% of actual value
Max.
Calibration 2
Points
Temperature
Display / 0 to 50.0 ºC / 0.1 ºC
Resolution
Automatic Standard Recognition • Changeable Low and High Calibration Values •
Functions Temperature Calibration • Multiplying Compensation (0.01 to 9.90) • Auto Hold / Auto Stable •
Automatic Power Off (30 mins.) • Low Battery Indicator • IP67 Water / Dust Proof • Replaceable Sensor
Display Custom (monochrome) digital LCD with backlight
Operating
Temperature / 5 to 40 ºC / ≤ 85% in relative humidity (no condensation)
Humidity
Battery Life Approx. 400 hrs. continuous use without backlight
ABS epoxy body / LaF3
Material ABS epoxy body / PVC sensor
crystal sensor
Dimensions 164 x 29 x 20 mm (excluding projections)
Mass Approx. 55g (including sensor and batteries)
1 & 10 ppm Fluoride
Standards (14 ml each)
Accessories 150 & 2000 ppm Standard Solutions (14 ml each) • Dropper
• TISAB (14 ml) • 5-ml
included Beaker • Syringe
Sampling Sheet B (5pcs) • CR2032 Batteries (2 pcs) • Instruction & Quick Manuals • Storage Case
* Applicable for models with temperature display

Correlation between LAQUAtwin measurement data and ion chromatography


Crops (NO3-) Isotonic drink, mineral water drinks and
mineral water (Na+, K+, Ca2+)
10000
Spinach, 1000
Komatsuna,
Cabbage,
Measurement data of

Measurement data of

Bok choy,
LAQUAtwin (ppm)

LAQUAtwin (ppm)

Napa cabbage,
Lettuce,
1000 Other
100

Na+ : y=1.127x R 2 =0.941


y = 0.988 x Ca2+: y=0.922x R 2 =0.990
R2 =0.937 K + : y=0.906x R 2=0.954

100 10
100 1000 10000 10 100 1000
Measurement data of ion chromotography (ppm) Measurement data of ion chromotography (ppm)
*When measuring Ca 2+, samples are pretreated in order to match the conditions of the ion chromatography.
| 09
Solutions & Accessories
LAQUAtwin Replacement Sensors
Part No. Model Description
3200459834 S010 pH Sensor (for B-711, B-712, B-713, pH-11, pH-22 & pH-33)
3200459866 S021 Salt Sensor (for B-721)
3200459867 S022 Sodium Ion Sensor (for B-722 & Na-11) LAQUAtwin
3200459868 S030 Potassium Ion Sensor (for B-731 & K-11) Replacement Sensors
Nitrate Ion Sensor (for B-741, B-742, B-743, NO3-11, NO3-11C &
3200459870 S040
NO3-11S)
3200459869 S050 Calcium Ion Sensor (for B-751 & Ca-11)
3200459672 S070 Conductivity Sensor (for B-771, EC-11, EC-22, & EC-33)
3200597237 S071 Salt EC Sensor (for Salt-11)
3200934450 S060-F Fluoride Ion Sensor (for F-11) pH Buffers Conductivity NaCl
Standard Standard
3200997083 S080-ORP ORP Sensor (for ORP-11) Solutions Solutions

LAQUAtwin Standard Solutions (6 x 14ml bottles per pack)


Part No. Model Description
3999960108 514-4 pH 4.01 Buffer
3200691954 514-686 pH 6.86 Buffer
3999960109 514-7 pH 7.00 Buffer Sodium Ion Potassium Calcium Ion
3999960110 514-22 1413 µS/cm Conductivity Standard Solution
Standard Ion Standard Standard
Solutions Solutions Solutions
3999960111 514-23 12.9 Conductivity Standard Solution
3999960112 514-05 0.5% NaCl Standard Solution
3999960113 514-50 5.0% NaCl Standard Solution
3999960114 514-20 Conditioning Solution (For Conductivity & Salt Sensors)
3200457723 Y022H 2000ppm Sodium Ion Standard Solution
3200457724 Y022L 150ppm Sodium Ion Standard Solution
Fluoride Ion TISAB 225 mV ORP
3200457719 Y031H 2000ppm Potassium Ion Standard Solution Standard Solution Standard
Solutions Solution
3200457720 Y031L 150ppm Potassium Ion Standard Solution
3200053433 Y041 5000ppm Nitrate Ion Standard Solution
3200053514 Y042 300ppm Nitrate Ion Standard Solution
3200053532 Y043 2000ppm Nitrate Ion Standard Solution
3200053535 Y044 30ppm Nitrate Ion Standard Solution
3200053536 Y045 150ppm Nitrate Ion Standard Solution
Nitrate Ion
3200457727 Y051H 2000ppm Calcium Ion Standard Solution Standard Solutions
3200457728 Y051L 150ppm Calcium Ion Standard Solution
3200991628 514-F-1 1ppm Fluoride Ion Standard Solution
3200991630 514-F-10 10ppm Fluoride Ion Standard Solution
3200991632 514-F-TISAB TISAB Solution
Sampling Sheet
3200997084 514-ORP-225 225 mV ORP Standard Solution Holder

LAQUAtwin Accessories
Part No. Model Description
3200053858 Y046 Sampling Sheet B (100pcs) for minute samples (≥ 0.05ml)
Sampling Sheet Holder (use with sampling sheet B for samples with Sampling Sheet B
3200459736 Y048
particulates)

10 |
Visit HORIBA’s website!
Water Quality Analyzers www.horiba-laqua.com

With over 60 years of engineering


excellence, HORIBA's diverse range of
water quality analyzers and electrodes
are ideal for everyday laboratory needs
through to the most demanding of
applications. Visit our website for a
wealth of useful information and water
quality measurement tips to help you
obtain the best results in your work.

Benchtop Meters
Developed using extensive
feedback from users, our new
LAQUA meters deliver the
best solution for water quality
analysis. Our LAQUA website
features an online 'Selection
Guide' to enable you to find
the perfect LAQUA meter and
electrode for your need.

Handheld Meters
In the lab, in the field or
anywhere you need it. LAQUA Application Notes
Handheld meters are designed
for use with one hand and with LAQUAtwin pocket meters offer quick
an IP67 waterproof rating and and convenient alternative to analyze
shock-resistant casing. Meters important parameters with high accuracy.
can be used for long periods, Several application notes are available at
even in dark places, making it (http://goo.gl/znwE6j) detailing the use of
ideal for field measurements in LAQUAtwin and the results achieved for the
rivers and lakes. respective applications. Additional application
notes will be added when available.
Electrodes
Various electrodes to match any
application. A wide range of products
for both benchtop and portable systems
are available, including easy and
reliable standard models, application-
focused models for small samples or
large containers, and special electrodes
for specific sample characteristics. Visit the HORIBA LAQUA Singapore
Channel on YouTube and subscribe to see
more of our videos.

• The contents of this catalog are subject to change without prior notice, and without any subsequent liability
to this company.
• The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
• It is strictly forbidden to copy the content of this catalog in part or in full.
• All brand names, product names and service names in this catalog are trademarks or registered trademarks
of their respective companies.
• Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
▄ Asia Pacific ▄ Europe, Middle East, & Africa ▄ Americas
HORIBA Instruments (Singapore) Pte. Ltd. HORIBA UK Limited HORIBA Instruments Incorporated
83 Science Park Drive, #02-02A, Kyoto Close, Moulton Park, 9755 Research Drive, Irvine,
The Curie, Singapore 118258 Northampton NN3 6FL California 92618 USA
Phone: 65 6908-9660 Phone: +44 1604 642500 Phone : +1 949 250 4811
Fax: 65 6745-8155 e-mail: waterquality@horiba.com Fax : +1 949 250 0924, +1 949 468 1890
e-mail: laqua@horiba.com e-mail: labinfo@horiba.com
Brochure PBT-02-2017B

You might also like