PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev.

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 14" class: 150 end FF
Customer P.O.: 130200916 Customer item: 8 VALVE SERIAL NUMBER: R2048400070001

VLT ODV: R20484 VLT ITEM: 7 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35794
TAG.: 01GEH07 AA053 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 5 Satisfactory YES X NO
Recorded leakage No leakage
nd
2 HYDROSTATIC BODY TEST Applied pressure (bar)
with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: N 237 Nm Nm 180 Nm Nm Nm For lever operated valve:
Max allowable running: N Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: N Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,3 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Andrea Gerardi DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID It 1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 09/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 14" class: 150 end FF
Customer P.O.: 130200916 Customer item: 8 VALVE SERIAL NUMBER: R2048400070003

VLT ODV: R20484 VLT ITEM: 7 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35786
TAG.: 01GEH27 AA053 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 5 Satisfactory YES X NO
Recorded leakage No Leakage
nd
2 HYDROSTATIC BODY TEST Applied pressure (bar)
with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: N 237 Nm Nm 192 Nm Nm Nm For lever operated valve:
Max allowable running: N Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: N Nm Nm 5 Nm Nm Nm Satisfactory YES NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,4 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID It 1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 09/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 14" class: 150 end FF
Customer P.O.: 130200916 Customer item: 8 VALVE SERIAL NUMBER: R2048400070004

VLT ODV: R20484 VLT ITEM: 7 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35787
TAG.: 01GEH37 AA053 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 5 Satisfactory YES X NO
Recorded leakage No Leakage
nd
2 HYDROSTATIC BODY TEST Applied pressure (bar)
with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: N 237 Nm Nm 204 Nm Nm Nm For lever operated valve:
Max allowable running: N Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: N Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,3 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID N 14 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(sIT 1047 OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 09/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 14" class: 150 end FF
Customer P.O.: 130200916 Customer item: 8 VALVE SERIAL NUMBER: R2048400070005

VLT ODV: R20484 VLT ITEM: 7 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35788
TAG.: 01GEH47 AA053 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 5 Satisfactory YES X NO
Recorded leakage No leakage
nd
2 HYDROSTATIC BODY TEST Applied pressure (bar)
with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: N 237 Nm Nm 216 Nm Nm Nm For lever operated valve:
Max allowable running: N Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: N Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES NO
Max allowable Opening time: (sec) 50 Opening time (sec) Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,2 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID It 1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 09/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 14" class: 150 end FF
Customer P.O.: 130200916 Customer item: 8 VALVE SERIAL NUMBER: R2048400070006

VLT ODV: R20484 VLT ITEM: 7 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35789
TAG.: 01GEH57 AA053 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 5 Satisfactory YES x NO
Recorded leakage No leakage
nd
2 HYDROSTATIC BODY TEST Applied pressure (bar)
with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES x NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: N 237 Nm Nm 185 Nm Nm Nm For lever operated valve:
Max allowable running: N Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: N Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES x NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES x NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 49 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,3 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Dirito Andrea DYNAMOMETRIC KEY ID


Satisfactory x internal TEST BENCH ID 14-IT 1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Dirito Andrea
DATE: DATE:
DATE: 12/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 14" class: 150 end FF
Customer P.O.: 130200916 Customer item: 8 VALVE SERIAL NUMBER: R2048400070008

VLT ODV: R20484 VLT ITEM: 7 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35791
TAG.: 01GEH77 AA053 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 5 Satisfactory YES X NO
Recorded leakage No leakage
nd
2 HYDROSTATIC BODY TEST Applied pressure (bar)
with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: N 237 Nm Nm 191 Nm Nm Nm For lever operated valve:
Max allowable running: N Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: N Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,1 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID 14 It 1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 12/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 14" class: 150 end FF
Customer P.O.: 130200916 Customer item: 8 VALVE SERIAL NUMBER: R2048400070016

VLT ODV: R20484 VLT ITEM: 7 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35799
TAG.: 02GEH57 AA053 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 5 Satisfactory YES x NO
Recorded leakage No leakage
nd
2 HYDROSTATIC BODY TEST Applied pressure (bar)
with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0ml/min Test duration (min) 2 Test duration (min) YES x NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: N 237 Nm Nm 180 Nm Nm Nm For lever operated valve:
Max allowable running: N Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: N Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES x NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES x NO
Max allowable Opening time: (sec) 50 Opening time (sec) 49 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 49 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,4 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Dirito Andrea DYNAMOMETRIC KEY ID


Satisfactory x internal TEST BENCH ID B14/It1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Dirito Andrea
DATE: DATE:
DATE: 12/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 8" class: 150 end FF
Customer P.O.: 130200916 Customer item: 36 VALVE SERIAL NUMBER: R2048400230003

VLT ODV: R20484 VLT ITEM: 23 Actuator type/brand: SQ07.2-K-Nx4/2-xx-25-F10


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35747
TAG.: 01GEJ38 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 2 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: 87
Nm Nm Nm 50 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 15 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 20 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 25 Opening time (sec) 25 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 25 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,1 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Andrea Gerardi DYNAMOMETRIC KEY ID


Satisfactory X internal X TEST BENCH ID It 1047 NORBAR ID

Not Satisfactory witness PRESSURE GAUGE(s) ID(s) OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Gerardi
DATE: DATE:
DATE: 02/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 8" class: 150 end FF
Customer P.O.: 130200916 Customer item: 36 VALVE SERIAL NUMBER: R2048400230004

VLT ODV: R20484 VLT ITEM: 23 Actuator type/brand: SQ07.2-K-Nx4/2-xx-25-F10


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35748
TAG.: 01GEJ48 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 2 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: 87
Nm Nm Nm 48 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 15 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 20 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 25 Opening time (sec) 25 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 25 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,4 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Gerardi Andrea DYNAMOMETRIC KEY ID


Satisfactory X internal X TEST BENCH ID It 1047 NORBAR ID

Not Satisfactory witness PRESSURE GAUGE(s) ID(s) OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Gerardi
DATE: DATE:
DATE: 30/06/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 12" class: 150 end RF
Customer P.O.: 130200916 Customer item: 37 VALVE SERIAL NUMBER: R2048400240001

VLT ODV: R20484 VLT ITEM: 24 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35805
TAG.: 01GEJ17 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 2 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar bar bar bar Handwheel radius (m)
Max allowable BTO: 132
Nm Nm Nm 100 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,4 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID 14-IT1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s) OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 07/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 12" class: 150 end RF
Customer P.O.: 130200916 Customer item: 37 VALVE SERIAL NUMBER: R2048400240002

VLT ODV: R20484 VLT ITEM: 24 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35806
TAG.: 01GEJ27 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 2 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: 132
Nm Nm Nm 106 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,5 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID 14 -IT1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s) OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 07/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 12" class: 150 end RF
Customer P.O.: 130200916 Customer item: 37 VALVE SERIAL NUMBER: R2048400240003

VLT ODV: R20484 VLT ITEM: 24 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35807
TAG.: 01GEJ37 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 2 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO X


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: 132
Nm Nm Nm 98 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,4 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID 14-IT1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s) OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 08/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 12" class: 150 end RF
Customer P.O.: 130200916 Customer item: 37 VALVE SERIAL NUMBER: R2048400240008

VLT ODV: R20484 VLT ITEM: 24 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35812
TAG.: 02GEJ37 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 2 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 24 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: 132
Nm Nm Nm 102 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm Nm Nm Nm Satisfactory YES x NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,4 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID IT1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s) OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 08/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 12" class: 150 end RF
Customer P.O.: 130200916 Customer item: 37 VALVE SERIAL NUMBER: R2048400240010

VLT ODV: R20484 VLT ITEM: 24 Actuator type/brand: SQ12.2-K-Nx4/2-xx-50-F14


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35814
TAG.: 02GEJ57 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A890
Acceptance: No leakage allowed Applied pressure (bar) 30
Test duration (min) 2 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 22 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 2 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO x


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: 132
Nm Nm Nm 108 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 10 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 10 Nm Nm Nm Satisfactory YES x NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 2 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 50 Opening time (sec) 50 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 50 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,5 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID 14 - IT 1047 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s) OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 08/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 4" class: 150 end FF
Customer P.O.: 130200916 Customer item: 49 VALVE SERIAL NUMBER: R2048400300001

VLT ODV: R20484 VLT ITEM: 30 Actuator type/brand: SQ05.2-K-Nx4/2-xx-9-F07


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35508
TAG.: 00GEA23 AA052 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A351
Acceptance: No leakage allowed Applied pressure (bar) 28.5
Test duration (min) 1 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 20.9 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0ml/min Test duration (min) 1 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 4 bar 4 bar bar bar Handwheel radius (m)
Max allowable BTO: 24
Nm Nm Nm 12 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 1 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 4 bar N.A.
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 9 Opening time (sec) 9 Opening time (sec) N.A.
Max allowable Closing time: (sec) Closing time (sec) 9 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,6 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID B9 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s)IT122 OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 06/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 4" class: 150 end FF
Customer P.O.: 130200916 Customer item: 51 VALVE SERIAL NUMBER: R2048400320001

VLT ODV: R20484 VLT ITEM: 32 Actuator type/brand: SQ05.2-K-Nx4/2-xx-9-F07


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35591
TAG.: 00GEK43 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A351
Acceptance: No leakage allowed Applied pressure (bar) 28.5
Test duration (min) 1 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 20.9 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0ml/min Test duration (min) 1 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 2,5 bar 2,5 bar bar bar Handwheel radius (m)
Max allowable BTO: 24
Nm Nm Nm 13 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 1 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 2,5 bar N.A.
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 9 Opening time (sec) 9 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 9 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,5 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID B9 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s)IT122 OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 06/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 4" class: 150 end FF
Customer P.O.: 130200916 Customer item: 52 VALVE SERIAL NUMBER: R2048400330001

VLT ODV: R20484 VLT ITEM: 33 Actuator type/brand: SQ05.2-K-Nx4/2-xx-9-F07


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS355752
TAG.: 00GEK46 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A351
Acceptance: No leakage allowed Applied pressure (bar) 28.5
Test duration (min) 1 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 20.9 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0ml/min Test duration (min) 1 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 2,5 bar 2,5 bar bar bar Handwheel radius (m)
Max allowable BTO: 24
Nm Nm Nm 14 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 1 Test duration (min) Satisfactory YES NO
Recorded leakage cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 2,5 bar N.A.
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 9 Opening time (sec) 9 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 9 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,5 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID B9 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s)IT122 OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 06/07/2021
PRESSURE TEST CERTIFICATE Nr. Mod. 4.10.2 BVPT Rev. 4

(Ref.Sper. API 598)


Customer: METITO VALVE: type Butterfly size: 4" class: 150 end FF
Customer P.O.: 130200916 Customer item: 53 VALVE SERIAL NUMBER: R2048400340001

VLT ODV: R20484 VLT ITEM: 34 Actuator type/brand: SQ05.2-K-Nx4/2-xx-9-F07


Test procedure No: FATR20484 Rev.: 0 Actuator serial number: 1721NS35593
TAG.: 00GEK10 AA051 Gear : YES NO X
TESTED SEQUENCE: APPLIED/RECORDED VALVES RESULT/NOTES
HYDROSTATIC BODY TEST: Body material: A351
Acceptance: No leakage allowed Applied pressure (bar) 28.5
Test duration (min) 1 Satisfactory YES X NO
Recorded leakage No leakage

2nd HYDROSTATIC BODY TEST Applied pressure (bar)


with external relief valve fitted (95% of set pressure of the relief valve) Applicable: YES NO X
Acceptance: No leakage allowed Test duration (min)
Recorded leakage Satisfactory YES NO

SIDE A SIDE B
HYDROSTATIC SEAT TEST Applied pressure (bar) 20.9 Applied pressure (bar N.A. Satisfactory
Max allowable leakage: 0 ml/min Test duration (min) 1 Test duration (min) YES X NO
Recorded leakage 0 ml/min Recorded leakage

SELF RELIEVING TEST SIDE A SIDE B Applicable: YES NO X

Acceptance: max bar Relief pressure (bar) Relief pressure (bar) Satisfactory YES NO

HYDROSTATIC D.B.B. TEST Applied pressure (bar) Applicable: YES NO X


Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

HYDROSTATIC D.P.E. TEST Applied pressure (bar Applicable: YES NO


(DIB-1; DIB-2) Test duration (min)
Max allowable leakage: Recorded leakage Satisfactory YES NO

OPERATION TORQUE TEST SIDE A SIDE B SIDE A+B BORE For gear operated valve:
Applied pressure (Δp) 6 bar 6 bar bar bar Handwheel radius (m)
Max allowable BTO: 24
Nm Nm Nm 14 Nm Nm Nm For lever operated valve:
Max allowable running: Nm Nm Nm 5 Nm Nm Nm Lever length (m)
Max allowable ETC: Nm Nm Nm 5 Nm Nm Nm Satisfactory YES X NO

PNEUMATIC SEAT TEST Type II (6 Bar) SIDE A SIDE B Applicable: YES X NO


(AIR) Applied pressure (bar) 6 Applied pressure (bar N.A.
Max allowable leakage: 0 cc/min Test duration (min) 1 Test duration (min) Satisfactory YES X NO
Recorded leakage 0 cc/min Recorded leakage

FUNCTIONAL TEST SIDE A SIDE B Applicable: YES X NO


Applied pressure (Δp) bar 6 bar
Actuator Supply 3ph/400V/60Hz Satisfactory YES X NO
Max allowable Opening time: (sec) 9 Opening time (sec) 9 Opening time (sec)
Max allowable Closing time: (sec) Closing time (sec) 9 Closing time (sec)

ANTI-STATIC TESTING Applicable: YES X NO


Applied D.C. supply: 12 (V)
Applied D.C. supply: 10 (Ω) Measured resistance (Ω): 0,6 Satisfactory YES X NO

TEST RESULT OPERATOR NAME Varni Marenco C. DYNAMOMETRIC KEY ID


Satisfactory X internal TEST BENCH ID B9 NORBAR ID

Not Satisfactory witness X PRESSURE GAUGE(s) ID(s)IT122 OTHERS

REMARKS:

VALVITALIA SIGNATURE CLIENT SIGNATURE TPI SIGNATURE

Christian Varni Marenco


DATE: DATE:
DATE: 06/07/2021