COOLANT ANALYSIS REPORT

GENERAL INFORMATION

Attention : Unit ID EX3184


Customer : PT.THIESS INDONESIA - Serial No & Model : HITACHI EX3600-6
SENGATA
Address : SANGATA SANGATA SANGATA Compartment : RADIATOR
NORMAL
Email : ThiessConditionMonitoring Fluid Type : COOLANT FLEETGUARD
@thiess.co.id PG PLUS

FLUID

Equipment Location : THSSANG THSSANG THSSANG Comments on Elevated Results


Fluid SMU : 64225 64478 65036 Si 151. pH 8.1 Glycol 50 % Nitrite 3200.
Color is Green. Si alarms are based on
Fluid Hrs : 13012 13265 207 New Coolant Reference. Coolant
Fluid Change (S/N) : No No No contamined and a lot of cediment.
Suggest to check the leaking area and
Filter Change (S/N) : make sure contamination is not entering
into coolant system. Change coolant as
DATE per engine manufacturers instructions.
Laboratory Number : 05341401 05347054 05360667 (RA)
Sample Date : 17/11/2021 08/12/2021 02/02/2022
Analysis Date : 19/11/2021 10/12/2021 04/02/2022
Report Date : 19/11/2021 10/12/2021 04/02/2022

ANALYSIS RESULT
NO ANALYSE METHOD RESULT SPECIFICATION*
Normal Caution Action
PROPERTIES
1 Color Visual BROWN BROWN GREEN
2 Odor Visual NO ODOR NO ODOR NO ODOR
3 pH ASTM D1287 7.6 7.5 8.1 8.5 11
4 % Glycol ASTM D3321 47 47 50 30 65
5 Nitrite KIT CC2602M 0.0 0.0 3200.0 1400 6000
6 Molybdate KIT CC2602M 1000.0 1000.0 1000.0
CONTAMINANTS
7 Iron ASTM D6595 1556.7 13.6 27.1
8 Copper ASTM D6595 236.0 69.3 19.6
9 Aluminium ASTM D6595 226.2 1.5 13.7
10 Lead ASTM D6595 318.9 0.1 0.1
11 Zinc ASTM D6595 418.7 20.3 45.5
INHIBITOR
12 Molybdenum ASTM D6595 1310.0 1000.0 1000.0
13 Silicon ASTM D6595 1659.0 151.6 151.8
For enquiries,Tekenomiks Sangata, email : Labsgt@techenomics.com, mobile : 08115817837
CONDITION MONITORING
TECHNICAL ADVANCE FOR ECONOMIC GAIN

Diagnosis on Elevated Results

Diagnosis 1. Sample No: 05360667


Si 151. pH 8.1 Glycol 50 % Nitrite 3200. Color is Green. Si alarms are based on New Coolant Reference. Coolant contamined and a lot of cediment.
Suggest to check the leaking area and make sure contamination is not entering into coolant system. Change coolant as per engine manufacturers
instructions. (RA)
Diagnosis 2. Sample No: 05347054
Si 151. pH 7.5 Glycol 47 % Nitrite 0. Color is Brown. Si alarms are based on New Coolant Reference. Coolant contamined and a lot of cediment.
Suggest to check the leaking area and make sure contamination is not entering into coolant system. Change coolant as per engine manufacturers
instructions. (RA)
Diagnosis 3. Sample No: 05341401
Si 1659. pH 7.6 Glycol 47 % Nitrite 0. Color is Brown. Si alarms are based on New Coolant Reference. Coolant contamined and a lot of cediment.
Suggest to check the leaking area and make sure contamination is not entering into coolant system. Change coolant as per engine manufacturers
instructions. (RA)
Diagnosis 4. Sample No: 05332722
Si 144. pH 7.7 Glycol 45 % Nitrite 0. Color is Brown. Si alarms are based on New Coolant Reference. Suggest to check the leaking area and make
sure contamination is not entering into coolant system. Change coolant as per engine manufacturers instructions.(RA)
Diagnosis 5. Sample No: 05317703
Si 141. pH 8.0 Glycol 47 % Nitrite 0. Color is Brown. Si alarms are based on New Coolant Reference. Suggest to check the leaking area and make
sure contamination is not entering into coolant system. Change coolant as per engine manufacturers instructions.(LR)
Diagnosis 6. Sample No: 05313207
Si 119. pH 7.9 Glycol 53 % Nitrite 1600. Color is Brown. Si alarms are based on New Coolant Reference. Suggest to check the leaking area and
make sure contamination is not entering into coolant system. Change coolant as per engine manufacturers instructions.(LR)