External Alarm Validation and Rectification

Acceptance Date 23 FEBRUARI 2024


Project Name 56A0H3G Indonesia IOH Wireless Consolidation Project
Site ID 14CLP0278
Site Name JERUK LEGI_WETAN
System Key -

This page will explain how this validation external alarm implementation in the field
accepted by both party

Review Status
Alarm External alarm (shall be Remarks
Position confirmed with NOC to OK NOT
# monitor the result of OK
alarm test)

1 Main Power Failure V When 2 or all 3 phase fails in 3 phase scenario


2 Rectifier Module V When rectifier module fails due to module internal failure but NOT due to
Failure/Rectifier Fault main power
3 High Temperature V High temperature inside the cabinet
/Indoor Return Vent
Temperature Sensor Fault
4 PLVD Disconnect (RRUs V When RRUs (i.e. Non-Priority Loads) are disconnected due to lack of battery
off)/ DC Under Voltage backup after 4 hours, typically PLVD/LVD1 is set to 46V. Then PLVD/LVD1
Reconnect level is set 49.5V or hysteresis is set to 3.5V.
5 Surge Arrester Failure/AC V When any of the 3 Surge arresters fail
SPD Fault
6 Load Breaker Trip/load V When any DC load breaker trips (i.e. telecom equipment power off) or
fuse break battery breaker trips
7 Door Open V When door is opened
8 Aviation Light Failure When Aviation light fails
9 Fire Smoke Heat Alarm Only for Indoor Shelter
10 Gensets Working If Applicable
11 Gensets Fails If Applicable
12 ATS Fail If Applicable
13 Low Fuel If Applicable
14
Site ID 14CLP0278
Site Name JERUK LEGI_WETAN

Acceptance of Device Alarm Image

Before After Before After

Main Power Failure Main Power Alarm Main Power Failure Alarm Main Power Failure
Failure

Rectifier Module Rectifier Module Alarm Rectifier Module Alarm Rectifier Module
Failure/Rectifier Failure/Rectifier
Fault Fault
failure/Rectifier Fault failure/Rectifier Fault

High High Alarm High Alarm High Temperature/Indoor


Temperature/Indo Temperature/Ind Temperature/Indoor Return Return Vent Temperature Sensor
or Return Vent oor Return Vent Vent Temperature Sensor Fault Fault
Temperature Temperature
Sensor Fault Sensor Fault
PLVD Disconnect/DC PLVD Alarm PLVD Disconnect/DC Under Alarm PLVD Disconnec/DC Under
Under Voltage Disconnect/DC Voltage Voltage
Under Voltage

Surge Arrester Surge Arrester Alarm Surge Arrester Failure/AC Alarm Surge Arrester Failure/AC SPD
Failure/AC SPD Fault Failure/AC SPD SPD Fault Fault
Fault
Before After Before After

Load Breaker Load Breaker Alarm Load Breaker Trip/load fuse Alarm Load Breaker Trip/load
Trip/load fuse Trip/load fuse break fuse break
break break

Door Open Door Open Alarm Door Open Alarm Door Open