RP

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 16

INK

Step 1:

Bấm front -> axis -> apply -> kiểu giống như mirror

Step 2: check mesh

Step 3: Scale mesh


Select Specify Scaling Factors -> X=1e-6 and Y=1e-6 -> Scale -> Close

WHAT IS SCALE FACTOR

Step 4:

Unit -> Set Units -> lengt in mm and surface tension in dyn/cm

Step 5

Change to Transient and Axisymmetric

Step 6
Model -> Multiphase – VOF
WHAT IS IMPLICIT BODY FORCE

STEP 7:
Materials -> Fluid -> Air -> Change/Create -> Fluent Database -> Copy -> Close

STEP 8:

Phase

Primary Phase: Air – Phase Material: Air

Secondary Phase: water-liquid – Phase Material: water-liquid


STEP 9:

Phase Interation -> Surface Tension -> Surface Tension Force Modelling -> Wall adhesion -> Constant
(edit) -> 73.5 dyn/cm=0.0735 n/m

STEP 10:

Boundary Conditions -> Operating Conditions -> X=0.1 and Y=0.03

STEP 11:

User Defined -> Functions -> Interpreted -> inlet.1c -> Interpret
STEP 12:

Inlet (velocity-inlet,id=2) -> Velocity Magnitude -> udf membrance _speed

STEP 13

Inlet (velocity-inlet,id=2) -> water-liquid -> Multiphase -> Volume fraction:1


Outlet -> water-liquid -> Multiphase -> Volume fraction:0

Wall no wetts -> Contac Angle: 175

Wall wetts -> Contact Angle: 90

STEP 14:

Methods:

Non-Iterative Time Advancement -> Scheme -> Fraction Step -> Momentum -> QUICK -> Volume fraction
-> Compressive
Step 15:
STEP 16: Initialization

Initialize

STEP 17:

Adapt -> refine/coarsen -> cell register -> new -> region -> name:hexahedron -> Xmax=0.1 and
Ymax=0.03

STEP 18: patch


Phase: water-liquid -> volume Fraction -> Value:1 -> Registers to patch: hexahedron

STEP 19:

Contours -> contour-volume-fraction -> Contours of: Phase -> Phase: water-liquid -> Save and displays

Step 20: Autosave


STEP 21: solution animation
STEP 22: EXPORT
STEP 23: RUN CALCULATIONS

You might also like