TEST REPORT

Customer Name & Address: SHIVA Report No. SUES –DT- Report Issue Dt: 5/1/2023
SHAKTI AERO MECH, H.NO : 11- Unique Lab Report No. :
144/85, A.P.H.B COLONY, MIG 2, Sample Registration No. : SUES –DT-
ROAD NO 1, IDPL, HYDERABAD – Sample Received On : 4/1/2023
500037. Test Start Date : 4/1/2023
D.C No. & Date: letter, 4/1/2023 Test Completion Date : 5/1/2023
Sample Description: S1 CP TBU MANDREL Sample Specification : IS 2062 E 275
STRUCTURE Ø 630X790 mm long
DRAWING NO: 02B -0090-MT-00-001
Equipment Used: Quanta-Emission Equipment Used, MODEL:

Calibration Date On : 07.10.2022 Calibration Date : 17.11.2022


Calibration Due On : 06.10.2023 Calibration Due On : 17.11.2023
I) TENSILE : Equipment Used, MODEL :
Test Method:

Test Observations:

Sl. No Particulars UTS, Yield Stress Elongation, %


N/mm^2 N/mm^2
Specifications Min
Limits Max
01 Tensile Specimen
II)CHEMICAL ANALYSIS:
Equipment Used: Quanta-Emission

Test Method: : ISO 630 - 1995

Test observations:

Sl. No. Particulars C% Mn% Si% S% P%

Specifications Min - - - - -
Limits
Max 0.21 1.4 0.35 0.045 0.045

01 S1 CP TBU 0.16 1.3 0.30 0.041 0.038


MANDREL
STRUCTURE Ø
630X790 mm
long

Result: The tested sample(s) confirms to the requirements of above mentioned specification with respect to the
tests conducted.

Tested BY For sriujjwala Engineering Services


Authorised Signtory

*****END OF THE REPORT*****