insulated enclosures for the protection of electrical and telecommunications equipment under all
types of environmental conditions.
Himel’s logistics centres in Barcelona and Sarre Union cover an area of 25,000
m2 and are highly automated. Their flexible organization allows processing and
delivery of order to be adapted according to demand thus ensuring
guaranteed delivery times.
Bringing the best to your business, from project definition to customer satisfaction
CMO-CMOX
accessories 34
Warranty
The most prestigious international quality certifications, together with a state-of-the-
art production process, enables us to guarantee the reliability and durability of our
products which have been exported extensively during years of total dedication to
our customers, guaranteed by our more than one million enclosures manufactured
a year.
PHOSTHATIZING
DRYING KILN
PAINTING CABIN
wall fixing and floor standing metal enclosures
canopies c c c
plinths
page 14 - 23 14 - 23 14 - 23 24 - 27
12 HIMEL
CRSX enclosures are particularly The main feature of OLN enclosures is that The PC applications stands out among the
recommended for corrosive environments or it is possible to suit them to form larger units. usual installation systems available with
those where a high degree of cleanliness is OLN enclosures.
required, such as in the pharmaceuticals or
food industries, etc.
c c c c c
c c c c
6 to 47 6 to 47 7 to 40
c c c
c
c c c
c c c c
c c c
c c c
c c c c
c c c c c
28 - 53 28 - 53 28 - 53 54 - 59 60 - 63
HIMEL 13
metal wall mounting enclosures
From 250 x 200 x 150 to 1200 x 1000 x 400 you
have more than 45 sizes to choose ... Wall fixing brackets fixed from
1• the outside and can be placed ○ ○ ○ ○ ○ ○ ○ ○
both horizontally or vertically.
Not included as standard
supply.
○ ○ ○ ○
and protects the inside
surface when opening ○ ○ 13
the door.
12
○ ○ ○ ○ ○ ○ ○ ○
A complete range
of mounting plates
suitable for most
12• types of installations. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
The fullest variety of
accessories in the
market.
○ ○ ○ ○ ○ ○
Insulated cable gland plates with
prepunched holes for easy cable
entry available as accessory.
11
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
10• Back of enclosure with
four M8x15 welded
studs with built-in
spacers for fixing of
mounting plate and
adjustable support.
14 HIMEL
Foamed-in
polyurethane
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 2•
gasket
guarantees
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
watertightness
for years.
○ ○ ○ ○ ○ ○ ○ ○
3• Perforated door
reinforcement profiles
allowing fixing of
equipment in up to
2 500 mm high enclosures.
1
○ ○ ○
3 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Transparent tempered
4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 4• glass door and fully
watertight, maintaining
IP-55 protection.
7
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○
10 5 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
8
6○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○
HIMEL 15
wall mounting steel enclosures CRN-CRS-CRSX
IP-55 (EN 60.529) IP-65 (EN 60.529)
FIG. 1 FIG. 2
B C B C
21 21
50
50 130
125
0
A-125
60
A-44
10 10
A-125
62
B-145
A-75
A-50
A-5
A
A-75
83
A-44
B-44
A-50
A-5
83
25*
A
B-133
B-44
125
B-50
B-75
B - 50 800
B - 75
B-5
B - 90* B-90*
B-5 B-5
FIG. 3 FIG. 4
B B C
22
A-125
10
83
B-145
A-75
A-50
A-44
A-44
A-5
A
A
25
B-44 B-44
B-50 B-50
B-75 B-75
16 HIMEL
wall mounting steel enclosures CRN-CRS-CRSX
IP-55 (EN 60.529) IP-65 (EN 60.529)
B C B C
50 20 50 20
125
10 10
A-43
A-125
A-125
H
A-50
A-75
B-43
A
A-5
B-43
25
83
A-50
A-75
A-43
A-5
A
B-133
83
B-145
B-50 I
125
B-75
FIG. 1
B-50
B-75
B-5
FIG. 2
J
KT doors do not fit
reinforcement profile.
B-87
B-5
25
HIMEL 17
selection guide for CRN-CRS-CRSX
wall mounting steel enclosures
18 HIMEL
fixed and
adjustable metallic insulating swing 19'' internal
metal insul. perf. univer.
supports chasis chasis racks doors
BRF-8/CRN
MM-46 MB-46 MF-46 MR-46 SDCR-300 - - BRP-7/CRN -
BRF-12/CRN
MM-66 MB-66 MF-66 MR-66 SDCR-300 DLM-84P - -
BRP-11/CRN
BRF-21/CRN
MM-106 MB-106 MF-106 MR-106 SDCR-300 DLM-168 - PIN-106
BRP-20/CRN
MM-108 MB-108 MF-108 MR-108 SDCR-250 DLM-240 DLA-240 BRP-20/CRN-800 PIN-108
MM-108 MB-108 MF-108 MR-108 SDCR-250 DLM-240 DLA-240 BRP-20/CRN-800 PIN-108
MM-108 MB-108 MF-108 MR-108 SDCR-300 DLM-240 DLA-240 BRP-20/CRN-800 PIN-108
MM-108 MB-108 MF-108 MR-108 SDCR-400 DLM-240 DLA-240 BRP-20/CRN-800 PIN-108
MM-1010 MB-1010 MF-1010 MR-1010 SDCR-300 - - - -
MM-1012 MB-1012 MF-1012 MR-1012 SDCR-300 - - - -
MM-128 MB-128 MF-128 MR-128 SDCR-300 - - BRP-25/CRN-800 PIN-128
MF-128 MR-128 SDCR-400 - - BRP-25/CRN-800 PIN-128
MM-128 MB-128
MF-1210 MR-1210 SDCR-300 - - - -
MM-1210 MB-1210
MM-1210 MB-1210 MF-1210 MR-1210 SDCR-400 - - - -
HIMEL 19
accessories for enclosures CRN-CRS-CRSX
mounting plates
A complete range of mounting plates
MM MB MF MR
comprising 4 versions able to provide all the
mountings required for this installation
system.
■ galvanized steel plates with drill holes for
fitting accessories and an earthing strip.
■ insulating plates in bakelite. P P P D
■ perforated plates in galvanized steel,
drilled with 3,6 mm Ø holes, 12,5 mm apart.
4,2 Ø self-tapping or M4 three-lobe screws
can be used.
■ universal plates for rapid fitting of switch
gear, manufactured in bichromated zinc-
coated steel. The arrangement of the drill S S S E
holes combined with the positioning of the
nuts cover all the fixing point distances.
to be fitted
metal insulating perforated universal
to enclosures
height width reference thick- weight reference thick- weight reference thick- weight P S
ness (Kg) ness (Kg) ness (Kg) reference D E
(A) (B) (mm) (mm) (mm)
250 200 MM-2520 2 0,4 MB-2520 4 0,13 MF-2520 2 0,3 215 150 - - -
300 250 MM-3025 2 0,6 MB-3025 4 0,2 MF-3025 2 0,5 265 200 MR-3025 253 228
300 300 MM-33 2 1,2 MB-33 4 0,3 MF-33 2 1,1 265 250 MR-33 255 251
300 400 MM-34 2 1,6 MB-34 4 0,5 MF-34 2 1,5 265 350 MR-34 255 351
400 300 MM-43 2 1,6 MB-43 4 0,5 MF-43 2 1,5 365 250 MR-43 348 251
400 400 MM-44 2 2,2 MB-44 4 0,7 MF-44 2 2,1 365 350 MR-44 345 351
400 600 MM-46 2 3,1 MB-46 4 1,1 MF-46 2 3 365 550 MR-46 345 551
500 400 MM-54 2 2,5 MB-54 4 0,9 MF-54 2 2,4 465 350 MR-54 450 351
500 500 MM-55 2 3,7 MB-55 4 1,2 MF-55 2 3,5 465 450 MR-55 450 451
600 400 MM-64 2 3,1 MB-64 4 1,1 MF-64 2 3 565 350 MR-64 555 351
600 500 MM-65 2 4 MB-65 4 1,4 MF-65 2 3,8 565 450 MR-65 555 451
600 600 MM-66 2 5,5 MB-66 4 1,7 MF-66 2 5,2 565 550 MR-66 555 551
600 800 MM-68 2,5 9,9 MB-68 4 2,3 MF-68 2,5 9,3 565 750 MR-68 555 751
700 500 MM-75 2 4,6 MB-75 4 1,7 MF-75 2 4,3 665 450 MR-75 645 451
800 600 MM-86 2,5 9,9 MB-86 4 2,3 MF-86 2,5 9 765 550 MR-86 750 551
800 800 MM-88 2,5 13,6 MB-88 5 4,5 MF-88 2,5 12 765 750 MR-88 750 751
800 1000 MM-810 2,5 16,9 MB-810 5 5,7 MF-810 2,5 16 765 950 MR-810 750 951
1000 600 MM-106 2,5 12,6 MB-106 5 4,2 MF-106 2,5 12 965 550 MR-106 945 551
1000 800 MM-108 2,5 16,9 MB-108 5 5,7 MF-108 2,5 16 965 750 MR-108 945 751
1000 1000 MM-1010 2,5 18,6 MB-1010 5 7,1 MF-1010 2,5 17 950 950 MR-1010 945 951
1000 1200 MM-1012 2,5 21,7 MB-1012 5 8,3 MF-1012 2,5 20 950 1150 MR-1012 945 1151
1200 800 MM-128 2,5 17,8 MB-128 5 6,8 MF-128 2,5 17 1150 750 MR-128 1145 751
1200 1000 MM-1210 2,5 21,7 MB-1210 5 8,3 MF-1210 2,5 20 1150 950 MR-1210 1145 951
20 HIMEL
accessories for enclosures CRN-CRS-CRSX
SDCR
(300)
(500)
(700)
steel.
■ cover plate and metal frame, colour
RAL 7035. Rapid screw-free assembly.
■ connector block for neutral and earth DLM 66 DLM 88 DLM 84
(1000)
(600)
■ see insulating chassis on page 74.
(800)
HIMEL 21
accessories for enclosures CRN-CRS-CRSX
22 HIMEL
accessories for enclosures CRN-CRS-CRSX
canopies
Metal canopies, protected internally
and externally with textured light grey
to fit to CRN-CRS enclosures
polyester-epoxy resin RAL 7032.
reference width depth F
(B) (C)
to fit to CRN-CRS enclosures
TJ-5020 500 200 36
reference width depth F
TJ-5025 500 250 42
(B) (C)
TJ-6020 600 200 36
TJ-2015 200 150 36 TJ-6025 600 250 42
TJ-2015 250 150 36 TJ-6030 600 300 42
TJ-2020 250 200 36 TJ-6040 600 400 42
TJ-3015 300 150 36 TJ-8020 800 200 36
TJ-3020 300 200 36 TJ-8025 800 250 42
TJ-4015 400 150 36 TJ-8030 800 300 42
TJ-4020 400 200 36 TJ-8040 800 400 42
TJ-4025 400 250 42 TJ-10030 1000 300 42
TJ-5015 500 150 36 TJ-10040 1000 400 42
v 6 mm LT-8 TT 6/CRN
v 7 mm LT-8 TT 7/CRN TT 7/ML TET 7/ML
v 8 mm LT-8 TT 8/CRN TT 8/CSX TT 8/ML TET 8/ML
safety - - - -
cylinder lock TER/ML
lock with
padlock - CBC/CRN - - -
bar
stainless
steel - KPLM - - -
padlock
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 23
control boxes CM
General description:
wide range
■ eight sizes of control boxes plus one box
for the keyboard.
control box based on the standard box Rear door enabling acces to the inside of the
■ the new control box is based on our CRN control box. Double bar lock
box.
rear door
■ the rear door opening 120° allows an easy
access to the inside of the box.
interior profiles
■ two profiles can be fitted inside, using the
bolts welded to the sides.
trim frame
■ the ergonomic design of the trim frame
makes it very easy to handle.
The trim frame is ready for fitting
accessories either when installing or later.
It is not necessary to foresee them from the
beginning.
Ergonomic frame trim for the manipulation of
accessories the box.
■ a wide range of easy to fit accessories,
lamp, diagram support, keyboard holder tray
and PC tray.
suspension system
■ a wide range of accessories to assemble
the suspension system, available in two height width depth reference
sizes, covering a large number of (mm) (mm) (mm)
applications.
design
■ the neutral design of the control boxes
300 300 200 HHHCM3030/200 50 80 50 80
allows them to be used in a large number of
applications. 300 400 200 HHHCM3040/200 ■ ■
24 HIMEL
control boxes CM
Colours available on request. Plastic trim cover to protect the aluminium Easy to fit accessories on the aluminium
section. profile with bolts.
Set of profiles to fit elements inside. Reinforcement designed to avoid Aluminium front plate, for fitting the dialogue
deformation of the box when suspended. elements.
50 80 50 80 50 80 50 80 50 80 50 80 50 80 50 80
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■
HIMEL 25
accessories for control boxes CM
IP-55 (EN 60.529)
turning coupling
reference
■ to fix the box to vertical tube. Box
suspended or supported. 50 HHHCM/UPC50
■ turning angle limited mechanically to about 30°. 80 HHHCM/UPC80
■ material use for manufacture: cast iron
and aluminium.
■ colour: RAL 7040.
vertical coupling
■ to join the system to a horizontal or vertical reference
surface. 50 HHHCM/UMR50
■ material use for manufacture: cast iron 80 HHHCM/UMR80
and aluminium.
■ colour RAL 7040.
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
26 HIMEL
accessories for control boxes CM
IP-55 (EN 60.529)
for joining the suspension system to a ■ color tapa registro RAL 7035.
horizontal surface ■ IP-54.
tubes reference
low power consumption lamp (11W) document pocket support PC and keyboard support trays
■ provides lighting and a 16 A power socket ■ holds plans or other documents in view ■ tray on which to place a laptop computer.
at the work station. easily. ■ tray on which to place a PC.
■ colour of support: RAL 7035. ■ colour of support: RAL 7035. ■ colour of support: RAL 7035.
■ colour of articulations: RAL 7040. ■ colour of articulations: RAL 7040. ■ colour of articulations: RAL 7040.
Reference: HHHCM/LAG Reference: HHHCM/SSP Reference: HHHCM/BPC (for folding PC)
Reference: HHHCM/BPT (for keyboard tray)
HIMEL 27
metal floor standing enclosures
○ ○ ○ ○ ○
1
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
6• For cable entry through 2• Standar handle lock
the cubicle bottom. system for OLN
Painted to RAL 7032. enclosures. Different
Available with one, two lock transformations
or more entrees. available.
Closing mechanism
outside of the sealed
zone.
2
○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○
5 3• Detail of self-centering
7 hanger.
7• Detail of displacement
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
every 25 mm.
28 HIMEL
○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
1• A complete range of
full or partial mounting
plates suitable for ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○
most types of
2• Inside view of the 2 mm
installations.
thick door with detail of
15 x 20 cross section
reinforcement frame
2 with ø 5 and ø 10 mm
drilling every 25 mm.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 5
○ ○ ○ ○
3 ○ ○ ○ ○ ○ ○
5• Detail of templated
glass fixing.
3• Standard flat lock
system for CMO
enclosures. Different
lock transformations
available.
4
○ ○ ○ ○ ○ ○ ○
Two doors
enclosures with an
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ internal locking
system to ensure the
thightenning.
4• A complete system to
earth the enclosure and
components.
1,5 mm thick back and side panels, following the process: degreasing, easy acces
2 mm for the door with reinforce- phosphating, passivating, driying, To the inside of the cubicle through
ment profiles. pouder exposy resin painting and removable uprights (even with the
polymerization. unit already assembled) wich
material, treatment and finish All this treatment ensures a perfect ensures a great level of accessibility
Enclosure profiles made of 1,5 mm adherance of the paint and ensures and makes working inside the
thick galvanised steel. for all the cubicle a greater cubicle easier.
Plain sheet for panels on the protection in harsh environments
painted with polyester-epoxy resin, and whenever drilling are done.
HIMEL 29
monobloc metal enclosures CMO - CMOX
IP-55 (EN 60.529)
Ease of fitting:
■ front frame has 11×13 mm holes
spaced 25 mm apart for fitting accessories,
modular distribution chassis, 19" racks, etc.
■ perforated profiles with holes every 25 mm
to enable depth adjustment of the mounting
plate and other accessories.
■ front door, opening 120o to left or right,
includes a perforated reinforcing frame
suitable for mounting de accessories.
Mini 105
Maxi C - 45
A - 90
A - 90
25 25
B - 90 18 x 18 B - 90
Ø10
Ø5
12,5
A - 150
A - 150
A - 66
A-
reference enclosure D
CMO 1610/40SB PM 400
CMO 1812/40SB PM 400
B -150
24
B - 66 B - 66 B - 66
B - 164* B - 164* B - 164*
B - 280 B/2 - 280
C - 164*
C - 164*
C - 164*
C - 130
C - 130
C - 130
30 HIMEL
monobloc metal enclosures CMO - CMOX
IP-55 (EN 60.529)
B - 66
B - 164*
B/2 - 280
C - 164*
C - 130
1200
A-70
730 B -70
A - 150
A - 150
A
20
M8 × 18 M8 × 18
650 650 B/2 - 150 B - 150
800 B C
636* B-164 *
67
67
67 C-164*
236*
F
E E
67
M8 × 18 M8 × 18
30
30
HIMEL 31
selection guide for CMO - CMOX
monobloc metal enclosures
external
dimensions (mm)
n° of ref. enclosures without ref. enclosures ref. enclosures ref. enclosures
height width depth doors mounting plate with mounting plate with glazed door made of stainless steel
1600 800 400 1 CMO 168/40 CMO 168/40 PM CMO 168/40 KT CMOX 168/40
1800 800 400 1 CMO 188/40 CMO 188/40 PM CMO 188/40 KT CMOX 188/40
2000 800 400 1 CMO 208/40 CMO 208/40 PM CMO 208/40 KT CMOX 208/40
32 HIMEL
plinths
HIMEL 33
accessories for enclosures CMO - CMOX
eyebolts
M12 lifting eyebolts bolted directly to the
enclosure.
reference: TMO/12
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
34 HIMEL
industrial cubicle system OLN
Basic configuration:
■ welded top frame.
■ welded bottom frame.
■ upright vertical profiles.
■ removable top.
■ removable rear panel.
■ plain door with lock.
■ mounting plate fixing supports. For enclosures with a mounting plate, use the For enclosures with transparent door, use the
■ mounting plate (ref. with PM). same reference but with the PM at the end. same reference but with the KT at the end (except
■ mounting plate slide rail. for 2 doors enclosures).
■ glazed tempered glass door on one-door
enclosures (ref. with KT) available.
A-90
A-90
ø10 ø10 25
ø5 ø5
■ 18x18 ■ 15x20
A-150
A-150
A-150
A-150
A+11
A
A
12,5
12,5
C-90
min.80
B-90 B-90 máx.C-90
B-150 B-150
B-247* B-247
C-164*
C-164*
C-110
C-110
1
C
C
B-110 B-110
ø12,5 90 ø12,5 1 Central crossbar for the 1200 mm with
enclosures.
* ground or plinth fixing dimensions
B B
HIMEL 35
selection guide for OLN
industrial cubicle system
panels
external
dimensions (mm) reference cubicle side panels back panels
height width depth n° of without with external internal quick external internal
doors mounting plate glazed door fixing fixing fixing fixing
1200 600 400 1 OLN 126/40 OLN 126/40 KT 2 PLOL 124 2 PLIOL 124 - PPION 126
1200 600 600 1 OLN 126/60 OLN 126/60 KT 2 PLOL 126 2 PLIOL 126 2 PLROL 126 PPION 126
1200 600 800 1 OLN 126/80 OLN 126/80 KT 2 PLOL 128 2 PLIOL 128 2 PLROL 128 PPION 126
1200 800 400 1 OLN 128/40 OLN 128/40 KT 2 PLOL 124 2 PLIOL 124 - PPION 128
1200 800 600 1 OLN 128/60 OLN 128/60 KT 2 PLOL 126 2 PLIOL 126 2 PLROL 126 PPION 128
1200 800 800 1 OLN 128/80 OLN 128/80 KT 2 PLOL 128 2 PLIOL 128 2 PLROL 128 PPION 128
1400 600 400 1 OLN 146/40 OLN 146/40 KT 2 PLOL 144 2 PLIOL 144 - PPION 146
1400 600 600 1 OLN 146/60 OLN 146/60 KT 2 PLOL 146 2 PLIOL 146 2 PLROL 146 PPION 146
1400 600 800 1 OLN 146/80 OLN 146/80 KT 2 PLOL 148 2 PLIOL 148 2 PLROL 148 PPION 146
1400 800 400 1 OLN 148/40 OLN 148/40 KT 2 PLOL 144 2 PLIOL 144 - PPION 148
1400 800 600 1 OLN 148/60 OLN 148/60 KT 2 PLOL 146 2 PLIOL 146 2 PLROL 146 PPION 148
1400 800 800 1 OLN 148/80 OLN 148/80 KT 2 PLOL 148 2 PLIOL 148 2 PLROL 148 PPION 148
1600 600 600 1 OLN 166/60 OLN 166/60 KT 2 PLOL 166 2 PLIOL 166 2 PLROL 166 PPION 166
1600 600 800 1 OLN 166/80 OLN 166/80 KT 2 PLOL 168 2 PLIOL 168 2 PLROL 168 PPION 168
1600 800 600 1 OLN 168/60 OLN 168/60 KT 2 PLOL 166 2 PLIOL 166 2 PLROL 166 PPION 166
1600 800 800 1 OLN 168/80 OLN 168/80 KT 2 PLOL 168 2 PLIOL 168 2 PLROL 168 PPION 168
1800 600 400 1 OLN 186/40 OLN 186/40 KT 2 PLOL 184 2 PLIOL 184 - PPION 186
1800 600 500 1 OLN 186/50 OLN 186/50 KT 2 PLOL 185 2 PLIOL 185 - PPION 186
1800 600 600 1 OLN 186/60 OLN 186/60 KT 2 PLOL 186 2 PLIOL 186 2 PLROL 186 PPION 186
1800 600 800 1 OLN 186/80 OLN 186/80 KT 2 PLOL 188 2 PLIOL 188 2 PLROL 188 PPION 186
1800 800 400 1 OLN 188/40 OLN 188/40 KT 2 PLOL 184 2 PLIOL 184 - PPION 188
1800 800 500 1 OLN 188/50 OLN 188/50 KT 2 PLOL 185 2 PLIOL 185 - PPION 188
1800 800 600 1 OLN 188/60 OLN 188/60 KT 2 PLOL 186 2 PLIOL 186 2 PLROL 186 PPION 188
1800 1000 400 1 OLN 1810/40 OLN 1810/40 KT 2 PLOL 184 2 PLIOL 184 - PPION 1810
1800 1000 400 2 OLN 1810/40/2P - 2 PLOL 184 2 PLIOL 184 - PPION 1810
1800 1000 500 1 OLN 1810/50 OLN 1810/50 KT 2 PLOL 185 2 PLIOL 185 - PPION 1810
1800 1000 500 2 OLN 1810/50/2P - 2 PLOL 185 2 PLIOL 185 - PPION 1810
1800 1000 600 1 OLN 1810/60 OLN 1810/60 KT 2 PLOL 186 2 PLIOL 186 2 PLROL 186 PPION 1810
1800 1000 600 2 OLN 1810/60/2P - 2 PLOL 186 2 PLIOL 186 2 PLROL 186 PPION 1810
1800 1200 400 2 OLN 1812/40/2P - 2 PLOL 184 2 PLIOL 184 - PPION 1812
1800 1200 500 2 OLN 1812/50/2P - 2 PLOL 185 2 PLIOL 185 - PPION 1812
1800 1200 600 2 OLN 1812/60/2P - 2 PLOL 186 2 PLIOL 186 2 PLROL 186 PPION 1812
2000 800 500 1 OLN 208/50 OLN 208/50 KT 2 PLOL 205 2 PLIOL 205 - PPION 208
2000 800 600 1 OLN 208/60 OLN 208/60 KT 2 PLOL 206 2 PLIOL 206 2 PLROL 206 PPION 208
For enclosures with mounting plate ask same reference with PM at the end.
•models without PM version.
36 HIMEL
mounting universal chassis internal door
plate
HIMEL 37
selection guide for OLN
industrial cubicle system
panels
external
dimensions (mm) reference cubicle side panels back panels
height width depth n° of without with external internal quick external internal
doors mounting plate glazed door fixing fixing fixing fixing
2000 800 800 1 OLN 208/80 OLN 208/80 KT 2 PLOL 208 2 PLIOL 208 2 PLROL 208 PPION 208
2000 1000 400 1 OLN 2010/40 OLN 2010/40 KT 2 PLOL 204 2 PLIOL 204 - PPION 2010
2000 1000 400 2 OLN 2010/40/2P - 2 PLOL 204 2 PLIOL 204 - PPION 2010
2000 1000 500 1 OLN 2010/50 OLN 2010/50 KT 2 PLOL 205 2 PLIOL 205 - PPION 2010
2000 1000 500 2 OLN 2010/50/2P - 2 PLOL 205 2 PLIOL 205 - PPION 2010
2000 1000 600 1 OLN 2010/60 OLN 2010/60 KT 2 PLOL 206 2 PLIOL 206 2 PLROL 206 PPION 2010
2000 1000 600 2 OLN 2010/60/2P - 2 PLOL 206 2 PLIOL 206 2 PLROL 206 PPION 2010
2000 1000 800 1 OLN 2010/80 OLN 2010/80 KT 2 PLOL 208 2 PLIOL 208 2 PLROL 208 PPION 2010
2000 1000 800 2 OLN 2010/80/2P - 2 PLOL 208 2 PLIOL 208 2 PLROL 208 PPION 2010
2000 1200 400 2 OLN 2012/40/2P - 2 PLOL 204 2 PLIOL 204 - PPION 2012
2000 1200 500 2 OLN 2012/50/2P - 2 PLOL 205 2 PLIOL 205 - PPION 2012
2000 1200 600 2 OLN 2012/60/2P - 2 PLOL 206 2 PLIOL 206 2 PLROL 206 PPION 2012
2000 1200 800 2 OLN 2012/80/2P - 2 PLOL 208 2 PLIOL 208 2 PLROL 208 PPION 2012
2200 600 600 1 OLN 226/60 OLN 226/60 KT 2 PLOL 226 2 PLIOL 226 2 PLROL 226 PPION 226
2200 600 800 1 OLN 226/80 OLN 226/80 KT 2 PLOL 228 2 PLIOL 228 2 PLROL 228 PPION 226
2200 800 600 1 OLN 228/60 OLN 228/60 KT 2 PLOL 226 2 PLIOL 226 2 PLROL 226 PPION 228
2200 800 800 1 OLN 228/80 OLN 228/80 KT 2 PLOL 228 2 PLIOL 228 2 PLROL 228 PPION 228
2200 1000 600 1 OLN 2210/60 OLN 2210/60 KT 2 PLOL 226 2 PLIOL 226 2 PLROL 226 PPION 2210
2200 1000 800 1 OLN 2210/80 OLN 2210/80 KT 2 PLOL 228 2 PLIOL 228 2 PLROL 228 PPION 2210
2200 1000 800 2 OLN 2210/80/2P - 2 PLOL 228 2 PLIOL 228 2 PLROL 228 PPION 2210
2200 1200 600 2 OLN 2212/60/2P - 2 PLOL 226 2 PLIOL 226 2 PLROL 226 PPION 2212
2200 1200 800 2 OLN 2212/80/2P - 2 PLOL 228 2 PLIOL 228 2 PLROL 228 PPION 2212
For enclosures with mounting plate ask same reference with PM at the end.
• models without PM version.
38 HIMEL
mounting universal chassis internal door
plate
HIMEL 39
selection guide for flat pack OLN
industrial cubicle system
Basic configuration:
OLMV:
■ hinged uprights, panel mounts and locking
elements assembled.
OLSI:
■ welded top frame with top.
■ welded bottom frame.
■ mounting plate slide rail.
■ mounting plate fixing support.
OLPP:
■ plain door with lock.
■ plain rear panel.
OLPU:
■ plain door with lock.
OLPU...KT:
■ glazed door with lock.
OLPO:
■ plain rear panel.
ADPUPOL:
■ back single door adaptation kit.
ADZPUPOL:
■ 2 back doors adaptation kit.
dimensions (mm) n° of vertical to and back panel back panel plain door glazed door
height width depth doors uprights base and door
(A) (B) (C)
1200 600 400 1 OLMV 12 OLSI 64 OLPP 126 OLPO 126 OLPU 126 OLPU 126KT
1200 600 600 1 OLMV 12 OLSI 66 OLPP 126 OLPO 126 OLPU 126 OLPU 126KT
1200 600 800 1 OLMV 12 OLSI 68 OLPP 126 OLPO 126 OLPU 126 OLPU 126KT
1200 800 400 1 OLMV 12 OLSI 84 OLPP 128 OLPO 128 OLPU 128 OLPU 128KT
1200 800 600 1 OLMV 12 OLSI 86 OLPP 128 OLPO 128 OLPU 128 OLPU 128KT
1200 800 800 1 OLMV 12 OLSI 88 OLPP 128 OLPO 128 OLPU 128 OLPU 128KT
1400 600 400 1 OLMV 14 OLSI 64 OLPP 146 OLPO 146 OLPU 146 OLPU 146KT
1400 600 600 1 OLMV 14 OLSI 66 OLPP 146 OLPO 146 OLPU 146 OLPU 146KT
1400 600 800 1 OLMV 14 OLSI 68 OLPP 146 OLPO 146 OLPU 146 OLPU 146KT
1400 800 400 1 OLMV 14 OLSI 84 OLPP 148 OLPO 148 OLPU 148 OLPU 148KT
1400 800 600 1 OLMV 14 OLSI 86 OLPP 148 OLPO 148 OLPU 148 OLPU 148KT
1400 800 800 1 OLMV 14 OLSI 88 OLPP 148 OLPO 148 OLPU 148 OLPU 148KT
40 HIMEL
selection guide for flat pack OLN
industrial cubicle system
dimensions (mm) n° of vertical to and back panel back panel plain door glazed door
height width depth doors uprights base and door
(A) (B) (C)
1600 600 600 1 OLMV 16 OLSI 66 OLPP 166 OLPO 166 OLPU 166 OLPU 166KT
1600 600 800 1 OLMV 16 OLSI 68 OLPP 166 OLPO 166 OLPU 166 OLPU 166KT
1600 800 600 1 OLMV 16 OLSI 86 OLPP 168 OLPO 168 OLPU 168 OLPU 168KT
1600 800 800 1 OLMV 16 OLSI 88 OLPP 168 OLPO 168 OLPU 168 OLPU 168KT
1800 600 400 1 OLMV 18 OLSI 64 OLPP 186 OLPO 186 OLPU 186 OLPU 186KT
1800 600 500 1 OLMV 18 OLSI 65 OLPP 186 OLPO 186 OLPU 186 OLPU 186KT
1800 600 600 1 OLMV 18 OLSI 66 OLPP 186 OLPO 186 OLPU 186 OLPU 186KT
1800 600 800 1 OLMV 18 OLSI 68 OLPP 186 OLPO 186 OLPU 186 OLPU 186KT
1800 800 400 1 OLMV 18 OLSI 84 OLPP 188 OLPO 188 OLPU 188 OLPU 188KT
1800 800 500 1 OLMV 18 OLSI 85 OLPP 188 OLPO 188 OLPU 188 OLPU 188KT
1800 800 600 1 OLMV 18 OLSI 86 OLPP 188 OLPO 188 OLPU 188 OLPU 188KT
1800 1000 400 2 OLMV 18 OLSI 104 OLPP 1810 OLPO 1810 OLPU 1810 OLPU 126KT
1800 1000 400 1 OLMV 18/2P OLSI 104 OLPP 1810/2P OLPO 1810 OLPU 1810/2 -
1800 1000 500 2 OLMV 18 OLSI 105 OLPP 1810 OLPO 1810 OLPU 1810 OLPU 1810KT
1800 1000 500 1 OLMV 18/2P OLSI 105 OLPP 1810/2P OLPO 1810 OLPU 1810/2 -
1800 1000 600 2 OLMV 18 OLSI 106 OLPP 1810 OLPO 1810 OLPU 1810 OLPU 1810KT
1800 1000 600 2 OLMV 18/2P OLSI 106 OLPP 1810/2P OLPO 1810 OLPU 1810/2 -
1800 1200 400 2 OLMV 18/2P OLSI 124 OLPP 1810/2P OLPO 1812 OLPU 1812/2 -
1800 1200 500 2 OLMV 18/2P OLSI 125 OLPP 1810/2P OLPO 1812 OLPU 1812/2 -
1800 1200 600 1 OLMV 18/2P OLSI 126 OLPP 1810/2P OLPO 1812 OLPU 1812/2 -
2000 300 500 1 OLMV 20 OLSI 35 OLPP 203 OLPO 203 OLPU 203 OLPU 203KT
2000 300 600 1 OLMV 20 OLSI 36 OLPP 203 OLPO 203 OLPU 203 OLPU 203KT
2000 300 800 1 OLMV 20 OLSI 38 OLPP 203 OLPO 203 OLPU 203 OLPU 203KT
2000 400 500 1 OLMV 20 OLSI 45 OLPP 204 OLPO 204 OLPU 204 OLPU 204KT
2000 400 600 1 OLMV 20 OLSI 46 OLPP 204 OLPO 204 OLPU 204 OLPU 204KT
2000 600 400 1 OLMV 20 OLSI 64 OLPP 206 OLPO 206 OLPU 206 OLPU 206KT
2000 600 500 1 OLMV 20 OLSI 65 OLPP 206 OLPO 206 OLPU 206 OLPU 206KT
2000 600 600 1 OLMV 20 OLSI 66 OLPP 206 OLPO 206 OLPU 206 OLPU 206KT
2000 600 800 1 OLMV 20 OLSI 68 OLPP 206 OLPO 206 OLPU 206 OLPU 206KT
2000 800 400 1 OLMV 20 OLSI 84 OLPP 208 OLPO 208 OLPU 208 OLPU 208KT
2000 800 500 1 OLMV 20 OLSI 85 OLPP 208 OLPO 208 OLPU 208 OLPU 208KT
2000 800 600 1 OLMV 20 OLSI 86 OLPP 208 OLPO 208 OLPU 208 OLPU 208KT
2000 800 800 1 OLMV 20 OLSI 88 OLPP 208 OLPO 208 OLPU 208 OLPU 208KT
2000 1000 400 1 OLMV 20 OLSI 104 OLPP 2010 OLPO 2010 OLPU 2010 OLPU 2010KT
2000 1000 400 2 OLMV 20/2P OLSI 104 OLPP 2010/2P OLPO 2010 OLPU 2010/2 -
2000 1000 500 1 OLMV 20 OLSI 105 OLPP 2010 OLPO 2010 OLPU 2010 OLPU 2010KT
2000 1000 500 2 OLMV 20/2P OLSI 105 OLPP 2010/2P OLPO 2010 OLPU 2010/2 -
2000 1000 600 1 OLMV 20 OLSI 106 OLPP 2010 OLPO 2010 OLPU 2010 OLPU 2010KT
2000 1000 600 2 OLMV 20/2P OLSI 106 OLPP 2010/2P OLPO 2010 OLPU 2010/2 -
2000 1000 800 1 OLMV 20 OLSI 108 OLPP 2010 OLPO 2010 OLPU 2010 OLPU 2010KT
2000 1000 800 2 OLMV 20/2P OLSI 108 OLPP 2010/2P OLPO 2010 OLPU 2010/2 -
2000 1200 400 2 OLMV 20/2P OLSI 124 OLPP 2010/2P OLPO 2012 OLPU 2012/2 -
2000 1200 500 2 OLMV 20/2P OLSI 125 OLPP 2010/2P OLPO 2012 OLPU 2012/2 -
2000 1200 600 2 OLMV 20/2P OLSI 126 OLPP 2010/2P OLPO 2012 OLPU 2012/2 -
2000 1200 800 2 OLMV 20/2P OLSI 128 OLPP 2010/2P OLPO 2012 OLPU 2012/2 -
2200 600 600 1 OLMV 22 OLSI 66 OLPP 226 OLPO 226 OLPU 226 OLPU 226KT
2200 600 800 1 OLMV 22 OLSI 68 OLPP 226 OLPO 226 OLPU 226 OLPU 226KT
2200 800 600 1 OLMV 22 OLSI 86 OLPP 228 OLPO 228 OLPU 228 OLPU 228KT
2200 800 800 1 OLMV 22 OLSI 88 OLPP 228 OLPO 228 OLPU 228 OLPU 228KT
2200 1000 600 1 OLMV 22 OLSI 106 OLPP 2210 OLPO 2210 OLPU 2210 OLPU 2210KT
2200 1000 800 1 OLMV 22 OLSI 108 OLPP 2210 OLPO 2210 OLPU 2210 OLPU 2210KT
2200 1000 800 2 OLMV 22/2P OLSI 108 OLPP 2210/2P OLPO 2210 OLPU 2210/2 -
2200 1200 600 2 OLMV 22/2P OLSI 126 OLPP 2210/2P OLPO 2212 OLPU 2212/2 -
2200 1200 800 2 OLMV 22/2P OLSI 128 OLPP 2210/2P OLPO 2212 OLPU 2212/2 -
HIMEL 41
industrial cubicle system for OLNM
motor control centre application
Basic configuration:
c welded top frame.
c welded lower frame.
c upright sections.
c removable top.
c removable rear panel.
c top and bottom front panels for modularity.
ext. dimensions
in (mm)
height width depth reference supplied in kit form
(A) (B) (C)
2000 600 600 OLNM 206/60 OLVP206M + OLSI66
2000 600 800 OLNM 206/80 OLVP206M + OLSI68
2000 800 600 OLNM 208/60 OLVP208M + OLSI86
2000 800 800 OLNM 208/80 OLVP208M + OLSI88
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
42 HIMEL
industrial cubicle system for OLNP
PC application
Detail of glazed door for monitor. Optional printer tray support. Compartment with adjustable tray for
keyboard and mouse.
590
590
195
1803,5
195
195
1603,5
1500
1300
747
747
900
HIMEL 43
accessories for enclosures OLN
44 HIMEL
accessories for enclosures OLN
eyebolts
M12 lifting eyebolts bolted directly to the
cubicle structure.
reference: TLN/12
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 45
accessories for enclosures CMO - OLN
mounting plate
Manufactured in galvanized steel. It includes
Ø10
a perimeter reinforcing rib and the vertical
edges are strengthened with a double edge
50
Depth adjustable in 25 mm intervals. Ø22
23
5
with mounting plates, it is possible to use
intermediate plates to obtain a continuous 11,5
plate surface. 23,5
Max. load 600 Kg (with plate right at the
back) and 500 Kg if placed on the middle.
46 HIMEL
accessories for enclosures CMO - OLN
HIMEL 47
accessories for enclosures CMO - OLN
enclosure
dimensions (mm) max. no column
height width modules assembly reference
(A) (B) 18 mm wide
1200 600 144 600 AF/COL 126
1200 800 192 800 AF/COL 128
1400 600 168 600 AF/COL 146
1400 800 256 800 AF/COL 148
1400 1000 168 600 + 400 AF/COL 1464
1400 1200 256 800 + 400 AF/COL 1484
1400 1200 336 600 + 600 AF/COL 1466 + DCOL*
1600 600 183 600 AF/COL 166
1600 800 288 800 AF/COL 168
1600 1000 189 600 + 400 AF/COL 1664
1600 1200 288 800 + 400 AF/COL 1684
1600 1200 378 600 + 600 AF/COL 1666 + DCOL*
1800 600 210 600 AF/COL 186
1800 800 320 800 AF/COL 188
1800 1000 210 600 + 400 AF/COL 1864
1800 1200 320 800 + 400 AF/COL 1884
1800 1200 420 600 + 600 AF/COL 1866 + DCOL*
1800 1600 640 800 + 800 AF/COL 1888
2000 600 252 600 AF/COL 206
2000 800 384 800 AF/COL 208
2000 1000 252 600 + 400 AF/COL 2064
2000 1200 384 800 + 400 AF/COL 2084
2000 1200 504 600 + 600 AF/COL 2066 + DCOL*
* order top/bottom adjustment rails separately stock code:
2000 1600 768 800 + 800 AF/COL 2088 DCOL…
B/2
A B/2
A
■ 1 busbar blanking fascia (300 mm wide). 1800 1200 800 AF/COL 1884
A - 200
48 HIMEL
accessories for enclosures CMO - OLN
metal covers
■ plain or cut-out in fixed and hinged
versions.
■ manufactured in sheet steel painted with
polyester-epoxy paint RAL 7032.
■ combinable by 150 or 200 mm module in
the same upright.
■ blank covers may be cut-out by user to
protect control apparatus or non-modular
protective devices.
■ cut-out covers for modular switch gear and
suitable for fitting blanking plugs.
reference: ATPUND.
■ hinged covers.
■ adjustable covers designed to fill the front
in multiple combinations.
HIMEL 49
accessories for enclosures CMO - OLN
C - 164
C - 145
C - 34
1000 500 ZUN 105/100 ZUN 105/200
1000 600 ZUN 106/100 ZUN 106/200
C - 106
1000 800 ZUN 108/100 ZUN 108/200
1200 300 ZUN 123/100 ZUN 123/200
1200 400 ZUN 124/100 ZUN 124/200
1200 500 ZUN 125/100 ZUN 125/200
1200 600 ZUN 126/100 ZUN 126/200 B - 228
1200 800 ZUN 128/100 ZUN 128/200 B - 164
1600 400 ZUN 164/100 ZUN 164/200 B-2
1600 500 ZUN 165/100 ZUN 165/200
1600 600 ZUN 166/100 ZUN 166/200
castors
Set of 4 rapid fitting castors (plinth fitting),
two of which have an automatic brake.
reference: RUT/ZUN.
mounting profiles
Profiles punched every 25 mm for fixing of
equipment inside the cubicle. Allow for depth
adjustment of the various installation
systems (partial mounting plates, 19" Racks,
etc.)
50 HIMEL
accessories for enclosures CMO - OLN
1400 800 27 BRPC27/OL BRPC27/OL 180 BRP 27/OL 1200 600 24 BRF24/OL
1600 800 31 BRPC31/OL BRPC31/OL 180 BRP 31/OL 1400 600 29 BRF29/OL
1800 800 36 BRPC36/OL BRPC36/OL 180 BRP 36/OL 1600 600 31 BRF33/OL
2000 800 40 BRPC40/OL BRPC40/OL 180 BRP 40/OL 1800 600 36 BRF38/OL
354 800 6 BRP 6/OL 2000 600 42 BRF42/OL
354 800 9 BRP 9/OL
621 800 12 BRP 12/OL
621 800 15 BRP 15/OL
887 800 18 BRP 18/OL
1021 800 21 BRP 21/OL
■ door tray.
■ door retainers.
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 51
locks for enclosures CMO - OLN
TM24/OLN 2 x 4 coin
TCOR/OLN crown (tube)
TAUSA/OLN channelled
TBENZ/OLN Daimler Benz
52 HIMEL
locks for enclosures CMO - OLN
EMP/OLN
CMO standard lock system. Also suitable
for OLN.
TPDT7/OLN 7 mm triangular key
Standard double bar mechanism TPDT8/OLN 8 mm triangular key
(supplied as standard).
c operated by:
v LDB 5 key
(in accordance with DIN 43668)
TPDC6/OLN 6 mm square key
TPDC7/OLN 7 mm square key
TPC8/OLN 8 mm square key
EMP/OLN
c for conversion to locking mechanisms for
internal doors PIL see enclosure locking
TPDES/OLN screwdriver slot
mechanisms for CRN.
c for conversion of locking mechanisms of
enclosures for PC applications or motor
control centres see panel locking
mechanism for PK.
locking mechanisms for CMOX optional lock inserts to transform handle lock
enclosures
Directly operated standard locking system characteristics key reference reference
retractable handle.
HIMEL 53
Monobloc control desks for customised solutions
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○
chassis back-to-back is
2 ○ ○ ○ ○ ○ very easy and provides
space for maximum of
equipment.
○ ○ ○ ○ ○ 1
3 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 1•
○ ○ ○ ○ ○ ○
54 HIMEL
The principle of construction of the Himel control desks (patent applied for) enables total access
to the equipment together with unhindered equipment installation.
This range of monobloc control desks includes versions with or without console.
○ ○ ○
2• And accessory is available
○ ○ ○ ○ ○ ○
to support the screen.
○ ○ ○ ○ ○
2
○ ○ ○ ○ ○ 1
○
○ ○ ○ ○ ○ ○ ○
securing the cables.
1 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
2
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
2• ○ ○
HIMEL 55
control desks PK-PKN-PKP
IP-55 (EN 60.529)
479
B-121 435
B-121
355
65°
463
B-150 B-150
126
195
70
60 70
1024
1024
900
723
650
650
764
764
396
B B
c double-bar locks fitted to doors, easily
25
25
93,5 93,5
panel to ease fitting switch gear. Drilled with
4,25 mm Ø holes at 25 mm intervals
B-187 B-187
B-57 B-57 c earth connection in the door, body and
mounting plate.
B-280 B-280
47,5
47,5
Basic configuration:
66
66
270
236
ø12
ø12
1
2 M8X1 1
2 M8X1
c 4 plate support brackets.
c mounting plate (only with PK..-PM).
B-164 B-164
c cable gland plate.
1 Maximum opening 56 mm.
Basic configuration:
c plain front door.
*These measurements show the usable c double-bar locking system.
dimensions. c 4 plate support brackets.
M6 x 15 earthing stud.
c mounting plate (only with PK/N..-PM).
c cable gland plate.
56 HIMEL
control desks PK-PKN-PKP
IP-55 (EN 60.529)
479
435
355
B-121 B-121 65°
100
562
126
B-150 B-150
70
195
60 70 min. 126
1025
max. 476
1025
min. 45
900
831
max. 395
750
723
650
650
764
764
24,5
B 527
200 B
150 165 150 200 165
24,5
94,5
79
79
25
597
78,5
1 1
c removable rear panel.
370
370
336
336
B-164 B-164
c mounting plate (only with PK..-PM).
B-50 B-50 c cable gland plate.
1 Maximum opening 56 mm.
compact metal control desk with top Painted internally and externally with
front panel and rear door PKP.../F textured light grey polyester epoxy resin to
RAL 7032.
Compact metal control desk with top front
c pneumatic retaining support on the control
panel.
module panel and mechanical support on
Rear door with triple action lock.
the console door.
25
4
447
80 80
482
407
390
1310
1372
299
299
2
132
B-93 B-93 b
min. 143
89 60
650
650
a max.
368/568
min. 53
526
566
477
566
477
max. 278/478
21
B-150 B-150
24,5
B B 427/627
845/1045
273/473 78
1 1
ø12 ø12
c double-bar locking system.
1
2 M8X18 1
2 M8X18 c 4 support brackets for bottom plate..
B-164 B-164
c bottom mounting plate, removable plate
NOTE: 2 cable entries on 1600-mm-wide
desks. and upper brackets (only with PK../F..-PM).
c cable gland plate.
HIMEL 57
accessories metal control desks PK-PKN-PKP
selection guide
mounting plates B
Bottom, total and front plates of the console D
manufactured in galvanized steel and
universal plates in dichromated galvanized E
steel.
With a strengthening rib around the
perimeter. Depth adjustable versions
adjustable in 25 mm intervals.
A C
58 HIMEL
modular consoles for PKP control FE
desks with removable rear panel
IP-55 (EN 60.529)
Modular consoles for PKP control desks c fitted with door holding retainer support.
with a removable rear panel, manufactured c the 300 mm depth console has a
in steel sheet, painted internally and removable rear panel and the mounting
externally with textured RAL 7032 light plate is depth adjustable.
grey epoxy polyester resin. c the locking mechanism is outside the
c two widths (400 and 600 mm) and two usable door area, allowing maximum use of
depths (200 and 300 mm), the latter fitted available space.
with a depth adjustable mounting plate and
screw-on removable rear panel to allow
easy access to the inside of the front panel.
c double bar lock mechanism in upper part
of front panel, easily interchanged with
a triangular or square key lock or standard
key lock.
assembly options
control desk
dimensions
(width)
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 59
metal enclosures for EMC
electromagnetic protection
IP-55 (EN 60.529)
Metal monobloc enclosures made from c closed body, without cable gland plates or
ALU-ZIN 150 special plate. Body made from openings.
a single folded and welded sheet. c earthing braid connecting body and door,
The presence of aluminium over 55% of the providing quality earthing and consequently
surface gives good reflection of good EMC.
electromagnetic waves. c metal lock with earth continuity helping to
Painted externally with textured polyester- improve general shielding.
epoxy resin, colour grey RAL 7032 .
outside dimensions (mm)
c supplied with galvanised mounting plate. height width depth reference fig.
Its low resistivity facilitates compensation of (A) (B) (C)
mass potentials. 400 300 200 CRAF 43/200PM 1
c special body-door gasket (IP + EMC) 400 600 200 CRAF 46/200PM 1
500 400 200 CRAF 54/200PM 2
provides electrical continuity between door 600 400 200 CRAF 64/200PM 2
and body, necessary for such installations, 600 600 250 CRAF 66/250PM 2
as well as watertightness and environmental 700 500 250 CRAF 75/250PM 2
800 600 300 CRAF 86/300PM 2
seal. 1000 800 300 CRAF 108/300PM 2
1200 800 300 CRAF 128/300PM 2
B C B C
21 21
50
50
125
A-44
10 10
A-75
A-50
A-5
A
A-75
A-44
B-44
A-50
A-5
25*
A
B-44
125
B-50
B-75
B-50
B-75
FIG. 1 FIG. 2
B-5
B-95/135*
Nivel de atenuación
Attenuation levelsen
in armarios
CRN-EMC CRN-CEM
enclosures
100
atenuación(dB)
(dB)
90
80
Attenuation
70
60
50
40
30
20 Magnetic
Campo magnético field
Electric field
Campo eléctrico
10
0
0,1 1 10 100 1000
frecuencia (MHz)
Frequency (MHz)
Detail of earthing braid built into the Special body-door gasket (IP + EMC)
enclosure between body and door, provide electrical continuity between door
guaranteeing good connection to earth and and body, necessary for such installations,
therefore good EMC. as well as watertightness and environmental
seal.
60 HIMEL
metal enclosures for EMC
electromagnetic protection
IP-55 (EN 60.529)
Mini 105
Maxi C - 45
A - 90
25 25
B - 90
A - 66
A-
100
Atenuación (dB)
90
Attenuation
80
70
60
B - 150 B - 150 C + 6,5
50
B - 66 40
B - 164* 30 Magnetic
Campo magnético field
Campo eléctrico
B - 280 20
Electric field
10
0
C - 164*
Frecuencia (MHz)
Frequency (MHz)
Detail of mounting rail for depth adjustement Detail of special IP + EMC gasket and door Lock outside the gasketed area.
of mounting plate anf earthing between reinforcement.
door, body and back of enclosure.
HIMEL 61
metal enclosures for EMC
electromagnetic protection
IP-55 (EN 60.529)
¿5 100
atenuación (dB)
90
Attenuation
■ 18x18 80
70
A-150
A-150
60
A+11
A
50
40
12,5
30
20 Magnetic
Campo field
magnético
10 Electriceléctrico
Campo field
C-90
min.80 0
m x.C-90 0,1 1 10 100 1000
B-90
frecuencia (MHz)
Frequency (MHz)
B-150
B-150 C+16
24
B-169* C+60
B-247*
C-164*
C-110
B-110
¿12,5
Detail of mounting rail for depth adjustement Detail of special IP + EMC gasket and door Lock outside the gasketed area.
of mounting plate anf earthing between reinforcement.
door, body and back of enclosure.
62 HIMEL
accessories for metal enclosures EMC
for electromagnetic protection
IP-55 (EN 60.529)
HIMEL 63
glass-reinforced polyester boxes
and enclosures
Mounting plates
Metal plates for heavy equipment, insulating for easy machining and perforated
together with a great array of fittings for an easy mounting.
Distribution chassis
Fitted with insulating and metal cover plates, mounting plates and DIN rail adjustable
depth supports.
Internal doors
For Polymel enclosures, mounting of signalling and control devices.
Plinths
Plinths can be an indispensable element for the correct use of the enclosure.
glass-reinforced polyester boxes
and enclosures
wall mounting polyester enclosures
selection guides 66 - 67 PLM 74 - 79
modular insulated boxes floor standing polyester cabinets
System 27 68 - 70 PLA 80 - 83
polyester meter cabinets din-distribution cabinets and
PN 71 - 73 pedestals PLD-ZD 98 - 99
Waterproofness: The Polyester L/S enclosure fits a polyurethane gasket and other systems
avoiding ingress of water and dust thus protecting the internal installation. The protection
degree of all enclosures is IP 66.
Easy machining: The easy machining of polyester L/S enclosures based both on its
mechanical rigidity and the features of the polymers facilitates basic opertaions such as cut-
outs, drillings, etc. required for the installation of components (push buttons, switches, fans,
etc.).
Self-extinguishing: Even though polymers generally do not perfom well under fire conditions
because of their organic origin the addition of fireproof additives to the SMC L/S composition
mekes the enclosure self-extinguishing, which is an essential feature of every electrical
installation.
Tamper proof: The design of the polyester L/S enclosure helps to avoid aggressions and/or
manipulations by unauthorised personnel.
Wheater proof: The properties of the SMC itself and the additives which strengthen its
resistance to sun radiation make polyester L/S enclosures particularly suitable for aoutdoor
applications or highly corrosive environments.
Double insulation: The SMC non-electrical consuctivity as a feature of the base raw material
along with the designof the components of the enclosure ensures a full protection to the end
users in case of accident. Double insulation is guaranteed.
Lightness: Polyester enclosures are between 25 and 45% lighter than their metal equivalents
in size but provide the same mechanical resistance.
glass reinforced polyester boxes
and enclosures
wall mounting
system 27 PN
degree of protection IP-65 IP-43
enclosure
features
insulated c c
universal
distribution frames
18 mm modules up to 48
internal doors
acces-
sories
canopies
plinths c
page 68 - 70 71 - 73
66 HIMEL
PN enclosures designed to house electrical PLD cabinet with ZD pedestal fitted, in a PLM has a wide range of accessories
material in general, and meters in particular, typical railway power distribution application. specially designed for the electrical
including electricity, gas and water meters. distribution applications.
The Dinimel chassis and other components
facilitate the assembly and installation of the
enclosures for this application.
c c
c c c
c c
up to 240 up to 364
c c
c c
c c
74 - 79 80 - 95 96 - 99
HIMEL 67
modular insulated boxes system 27
IP-65 (EN 60.529)
M6 inserts for fixing the mounting plate or Security sealable screwdriver operated join Insulated mounting plate fixed to base.
various switch gear. between the lid and base (supplied as Option of metal or bakelite plate.
standard).
180 540
1827… 110 138 45 3654… 200 70 200 138 45 95
2 1 2
249
200
270
249
1 3 2,3
290
360
339
339
159 12 122,2 2 6 3
4 2,7
519
159 12 122,2 3 3
5 4
260 260
270
2727… 200 138 45 95
1
540
249
249
4 2 2,3
249 12 122,2 2 3* 2
1 2
3
200
249
260
8 3
519
540
70
360
2736… 290 138 45 95 2,7
260
200
7 4
519
1 12 122,2 3 3
249
6 5
200
270
249
4 2 2,3
339 260 260
12 122,2 2 3* 2
3
339
720
3672… 290 70 290 138 95
360
3636… 290 138 45
1 2
1
290
360
339
339
6 3
2,7
290
360
339
339
4 2 699
2,7 12 122,2 3,5
339 5 4
12 122,2 3
3 350 350
339
720
5472… 290 70 290 138 95
540
2754… 200 70 200 138 45 95 1 2
200
260
1 2 8 3
249
200
270
249
6 3 2,7
519
540
70
519
12 122,2 2,5 3* 2,5
5 4 2,7
260
200
260 260 7 4
699
12 122,2 4
6 5
* The 3 mm thickness is for polyester lids. 350 350
68 HIMEL
modular insulated boxes system 27
IP-65 (EN 60.529)
selection guide
transparent opaque polyester bases transparent opaque polyester mounting
lid boxes lid boxes lid boxes lids lids lids plates
external
dimensions low low
(mm.) lid ref. lid ref. steel polyester bakelite
180 270 180 PLS 1827 PLSO 1827 PLSP 1827 FPLS 1827 TPLS 1827 TPLSO 1827 TPLSP 1827 PMM 1827 PMA 1827 PMA/B 1827
270 270 180 PLS 2727 PLSO 2727 PLSP 2727 FPLS 2727 TPLS 2727 TPLSO 2727 TPLSP 2727 PMM 2727 PMA 2727 PMA/B 2727
270 270 230 PLS 2727 A• PLSO 2727A• - FPLS 2727 TPLS 2727 A• TPLSO 2727 A• - PMM 2727 PMA 2727 PMA/B 2727
270 360 180 PLS 2736 PLSO 2736 PLSP 2736 FPLS 2736 TPLS 2736 TPLSO 2736 TPLSP 2736 PMM 2736 PMA 2736 PMA/B 2736
270 360 230 PLS 2736 A• PLSO 2736 A• - FPLS 2736 TPLS 2736 A• TPLSO 2736 A• - PMM 2736 PMA 2736 PMA/B 2736
270 540 180 PLS 2754 PLSO 2754 PLSP 2754 FPLS 2754 TPLS 2754 TPLSO 2754 TPLSP 2754 PMM 2754 PMA 2754 PMA/B 2754
270 540 230 PLS 2754 A• PLSO 2754 A• - FPLS 2754 TPLS 2754 A• TPLSO 2754 A• - PMM 2754 PMA 2754 PMA/B 2754
360 360 180 PLS 3636 PLSO 3636 PLSP 3636 FPLS 3636 TPLS 3636 TPLSO 3636 TPLSP 3636 PMM 3636 PMA 3636 PMA/B 3636
360 540 180 PLS 3654 PLSO 3654 PLSP 3654 FPLS 3654 TPLS 3654 TPLSO 3654 TPLSP 3654 PMM 3654 PMA 3654 PMA/B 3654
360 540 230 PLS 3654 A• PLSO 3654 A• - FPLS 3654 TPLS 3654 A• TPLSO 3654 A• - PMM 3654 PMA 3654 PMA/B 3654
540 540 180 PLS 5454 PLSO 5454 PLSP 5454 FPLS 5454 TPLS 5454 TPLSO 5454 TPLSP 5454 PMM 5454 PMA 5454 PMA/B 5454
540 540 230 PLS 5454 A• PLSO 5454 A• - FPLS 5454 TPLS 5454 A• TPLSO 5454 A• - PMM 5454 PMA 5454 PMA/B 5454
360 720 230 PLS 3672 A• PLSO 3672 A• - FPLS 3672 TPLS 3672 A• TPLSO 3672 A• - PMM 3672 PMA 3672 PMA/B 3672
540 720 230 PLS 5472 A• PLSO 5472 A• - FPLS 5472 TPLS 5472 A• TPLSO 5472 A• - PMM 5472 PMA 5472 PMA/B 5472
• High lid boxes.
boxes,
bases
and lids
180 × 270 270 × 270 270 × 360 270 × 540 360 × 360 360 × 540 540 × 540 360 × 720 540 × 720
dims. 180×270×180 270×270×180 270×360×180 270×540×180 360×360×180 360×540×180 540×540×180 - -
reference PLS 1827 PLS 2727 PLS 2736 PLS 2754 PLS 3636 PL 3654 PLS 5454 - -
transparent
lid boxes
reference PLSP 1827 PLSP 2727 PLSP 2736 PLSP 2754 PLSP 3636 PLSP 3654 PLSP 5454 - -
weight 1,4 2,2 2,4 3,3 2,9 4,5 6,3 - -
dims. 180×270×135 270×270×135 270×360×135 270×540×135 360×360×135 360×540×135 540×540×135 360×720×135 540×720×135
bases
reference FPLS 1827N FPLS 2727N FPLS 2736N FPLS 2754N FPLS 3636N FPLS 3654N FPLS 5454N FPLS 3672N FPLS 5472N
weight 0,94 1,3 1,4 1,8 1,6 2,4 3,5 3 3,9
dims. 180×270×45 270×270×45 270×360×45 270×540×45 360×360×45 360×540×45 540×540×45 - -
reference TPLS 1827 TPLS 2727 TPLS 2736 TPLS 2754 TPLS 3636 TPLS 3654 TPLS 5454 - -
transparent
TPLSP 1827 TPLSP 2727 TPLSP 2736 TPLSP 2754 TPLSP 3636 TPLSP 3654 TPLSP 5454 - -
lid
reference
weight 0,5 0,9 1 1,4 1,3 1,7 2,8 - -
mounting plates
dims. 140×230×2 230×230×2 230×320×2 230×500×2 320×320×2 320×500×2 500×500×2 320×680×2,5 500×680×2,5
metal
reference PMM 1827 PMM 2727 PMM 2736 PMM 2754 PMM 3636 PMM 3654 PMM 5454 PMM 3672 PMM 5472
weight 0,5 0,8 1,1 1,8 1,5 3 4 4,2 6,7
dims.
polyester
weight 0,2 0,3 0,4 0,6 0,5 1,1 1,9 1,6 2,5
dims. 133×223×4 230×230×4 230×320×4 230×500×4 320×320×2 320×500×4 500×500×4 320×680×4 500×680×4
bakelite
reference PMA/B 1827 PMA/B 2727 PMA/B 2736 PMA/B 2754 PMA/B 3636 PMA/B 3654 PMA/B 5454 PMA/B 3672 PMA/B 5472
in
weight 0,18 0,3 0,4 0,6 0,5 0,9 1,4 1,2 1,9
HIMEL 69
accessories for modular system 27
insulated boxes
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
70 HIMEL
polyester meter cabinets PN
IP-43 (EN 60.529)
PN-53/ML enclosure
Glass-fibre reinforced polyester hot
moulded enclosures. Light grey colour
similar to RAL 7032 (weatherproof).
■ self-extinguishing; high resistance to
impact and temperature.
■ self-ventilated; excellent outdoor
performance; flush or embedded mounting.
■ unlosable lid with a triangular key lock
seal.
■ available with a mounting plate for single
or triple phase meter.
Ref.: PN-53/P1TM.
■ designed as general enclosure for
electrical material and particularly for
electricity meters.
Single-part body with M6 inserts for fixing of mounting plate or other equipment.
208
wall fixing
540
550
410
163
270
212
15
156
HIMEL 71
polyester meter cabinets PN
IP-43 (EN 60.529)
external
dimensions
(mm.)
72 HIMEL
polyester meter cabinets PN
IP-43 (EN 60.529)
TJPN-34 PN-34
TJPN-55 PN-55
TJPN-57 PN-57
pole fixing
Pole fixing supports for each model in zinc
passivated steel are available.
BF-4 PN-34
BF-5 PN-55
BF-7 PN-57
BF
meter windows
Provided with sealing gasket. U.V. rays
resistant.
reference features
Other accessories available for PN range: ■ cable cover for PN-55 and PN-57.
■ coupling frame. ■ wall fixing suite.
■ cross-beam and cable gland plate for PN-55. ■ joining gasket.
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 73
wall mounting polyester enclosures PLM
Seven sizes and several models that can be customised in
order to provide the most suitable enclosure for each
application.
Highly reinforced desing with ribs. 1• External attachment
to wall by means of
stainless steel or
○
polyester fixing lugs.
○
○
○
15• Built-in canopy which
○
protects the door and its
○
○ ○
○
gasket.
○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
15
14• A complete range of
mounting plates suitable
for most types of 7 ○
installations. ○
○ ○
○ ○
○ ○
The fullest variety of ○ ○
○ ○
accessories in the ○
○
○
market. ○
○
○
○
○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 14
74 HIMEL
2• The 25 mm pitched moulded
locations in the back of the
enclosure, allow the direct
○ ○ 3• Cabinet with
attachment of mounting rails or
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○
4• Built in standard
○
○
○
points locking for
○
○ PLM 108.
○
○
6 Different lock
○
○
transformations
○
○
○
○ ○ ○
available.
○
○
2 4
○ ○ ○
3
○
○
○
○
○
○
○ ○ ○
○
○
○
○ 5• Maximum usable 6• 4 moulded bosses
○ ○ ○
○
○ space, door on inside of the door
○
○
○ 5 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ provided with a grid for inserts help to
○
○ pattern for centreing assemble accessories.
○
○ of equipment.
○
○ ○ ○ ○ 13 ○
○
○
○ 11 ○ ○ ○12 ○
8 ○
○
○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○
○
○
10 ○
○
○
○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○
○
○
○
○
○
○
○ 7• Self-ventilation
○
○ windows at the rear
○
○ ○ ○ ○ ○ ○ ○ ○ ○ of the cabinet.
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
○ ○
8• The moulded in
polyrethane sealing gasket
10• Reversible internal door
ensures the IP-66.
grid patterned, on the
○ ○
inside for quicker
Internal stainless steel
positioning of equipment.
hinges, built in the door
with safety pins, easily
removable. Door opening
over 180°.
HIMEL 75
wall mounting polyester enclosures PLM
IP-66 (EN 60.529)
Hot pressed glass-fibre reinforced polyester ■ resistant to the main chemical and
enclosures. atmospheric agents.
■ single-piece body: monobloc. ■ corrosion resistant.
■ colour: grey to RAL 7032. ■ stable under ultraviolet rays.
■ fully reversible. ■ suitable for double insulated control panels
■ intended for use in both indoor and in accordance with IEC 439-1(EN 60.439.1)
outdoor environments. standard.
■ wide range of accessories permitting use ■ high mechanical impact strength IK-10
in distribution, control and measurement (20 J) in accordance with EN 50.102.
panels for industrial and recreational ■ IP-66 in accordance with IEC 529
facilities. (EN 60.529).
■ inserts on front of enclosure for fixing ■ UL type approval in accordance with
distribution frames and interior door. UL 50, Nema 4 x and 12.
■ self-extinguishing. ■ IMQ type approval in accordance with
■ extreme operating temperatures from IEC C. 431 for extreme operating
-50 to 150ºC. temperatures (-25 to 60ºC).
reference PLM-... B 5 C
M8
32 43 54 64 75 86 108
Ø8
A 310 430 530 647 747 847 1056
B 215 330 430 436 536 636 852
D
G S
H
R
A
L 8 13 13 13 15 15 15
L
M
16
76 HIMEL
wall mounting polyester enclosures PLM
IP-66 (CEI-529)
selection guide
plain door glazed door mounting plates DINIMEL
enclosures enclosures chassis
external
dimensions mm.
depth adjustable
height width depth lock lock insulating metal perforated universal reference internal pole fixing
supports
normal three-point normal three point door set
310 215 160 PLM-32** - PLM-32/KT - MB-32 MM-32 MF-32 MR-32 - - - -
308 255 160 PLM-3025 - PLM-3025/KT - MB-3025 MM-3025 MF-3025 MR-3025 - DL/PLM18 PI-3025/PLM -
430 330 200 PLM-43 PLM-43/CME PLM-43/KT PLM-43 KT/CME MB-43 MM-43 MF-43 MR-43 DPLM-200 DLA-24 PIP-43 SFP-300
530 430 200 PLM-54 PLM-54/CME PLM-54/KT PLM-54 KT/CME MB-54 MM-54 MF-54 MR-54 DPLM-200 DLA-48 PIP-54 SFP-400
647 436 250 PLM-64 PLM-64/CME PLM-64/KT PLM-64 KT/CME MB-64 MM-64 MF-64 MR-64 DPLM-250 DLA-48P PIP-64 SFP-400
747 536 300 PLM-75 PLM-75/CME PLM-75/KT PLM-75 KT/CME MB-75 MM-75 MF-75 MR-75 DPLM-300N DLA-66 PIP-75 SFP-500
847 636 300 PLM-86 PLM-86/CME PLM-86/KT PLM-86 KT/CME MB-86 MM-86 MF-86 MR-86 DPLM-300N DLA-84 PIP-86 SFP-600
DLA-112
1000 800 350 PLM-108(1) - PLM-108/KT* - MB-108 MM-108 MF-108 MR-108 DPLM-350 DLA-240 PIP-108 SFP-800
** PLM-32 model in polycarbonate, PLM-32 KT model with transparent polycarbonate door. (1) 3 points lock system enclosures.
mounting plates
A complete range of plates which can be
directly fixed to the enclosure supports or to
the depth adjustable supports provides the
solution to this type of installation.
■ made of galvanized steel.
■ insulating plates in bakelite.
■ perforated plates in galvanized steel,
drilled with 3,6 mm Ø holes, 12,5 mm apart.
■ universal plates for rapid fitting of switch
gear, manufactured in dichromated zinc-
plated steel.
dimensions (mm.)
metal insulating perforated universal
S S S E 15
D
P
P
P
10,5 10,5
12.5
12.5
ø6.5 ø3.6
A-75
A-75
12.5
ø8.5
25
20 25
12.5
HIMEL 77
accessories for enclosures PLM
78 HIMEL
accessories for enclosures PLM
locks
optional standard lock inserts for models PLM-32 to PLM-86 three points locks
TT6/CRN ∆ 6 mm triangular
TT7/CRN ∆ 7 mm triangular
TT8/CRN ∆ 8 mm triangular
optional lock transformation for model PLM-108 into a handle
KPLM stainless steel padlock lock
TEDB/PL double bar lock
TEC6/PL v 6 mm square
DBP double back wing key TEC7/PL v 7 mm square
TEC8/PL v 8 mm square
optional standard lock inserts for model PLM-108 TEL-JIS/PL lock with JIS lock
TEL-FAC/PL lock with FAC lock
TC6/PL v 6 mm square
TC7/PL v 7 mm square
TC8/PL v 8 mm square TER/PL lock with reinforced lock
TT7/PL ∆ 7 mm triangular
TT8/PL ∆ 8 mm triangular TE/PL handle without lock
TEM/PL manual lock
BC/PL stainless steel padlock
BCME/PL padlock
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 79
reinforced polyester cabinets PLA
PLA cabinets offer superior mechanical resistance against impacts, which
makes them suitable for urban applications.
A compact structure of the different components of the cabinet, the design
of the reinforcements along with the thickness of the material guarantee an
1• ○ ○ ○
excellent rigidity and resistance.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
The IP-65 rating ensured through a gasket which shape and material have
been specially designed. PLA cabinets are particularly suitable for industrial
applications where the exposure to corrosive chemical agents, weather,
etc... is constant.
The top opening provides the
enclosure self ventilation, thus
PLA range: preventing internal
- from 500 to 1500 mm height. condensations while still
providing an IP-44 rating without
- from 500 to 1250 mm width.
any gasket and IP-54 rating with
- 320 and 420 mm depth. gasket. A canopy prevents the
foreign matter entry.
○
○
○
○
○
○
○
○
○
○
○
○
14
○
13• Wall fixing brackets. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 13
○
○
○ 12
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
12• Pole fixing set.
○ ○ ○ ○ ○ ○ ○ ○ Inner door ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ 11
○ ○ ○
○
○ ○
○ ○ ○
○ ○
○ ○ ○ 9
○ ○ ○
○
○ ○
○ ○ ○ 10
○ ○
○ ○
11• Metal, insulating and
○
○
perforated mounting ○ ○ ○
○
○ ○ ○
○
○ ○ ○
○
supports. ○
○
○
○
○
○
○
○
○
○
○ ○ ○
○
○
○
○
○
○
○ ○ ○
○
10• Open bottom for ○ 9• Mounting plate
○
access of underground ○ depth adjustable
○
○
80 HIMEL
2• Detail of 120° hinge with
○ ○ ○ ○ stainless steel safety pin
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○
cabinets. RET/PLA or
○
○
RET/PLAZ.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
2
○
○
○
3
○
○
○
○
○
○
4
○
Highly reinforced
○
○ ○ ○
○ ○ ○
○
○
○
5 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
8 Reinforcement to
○
○
○
prevent forcing of
○
○
the door.
○
6• Detail of
○
fixing of
○
6○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○
glazed door.
○
○
○
○
○
7○ ○
○
○ ○ ○ ○○
○
○
○
○
○
○
○
○
○
○
○
○
8• Detail of bosses on ○
○ 7• 180° door opening for
○
the doors lateral and ○ improved access to the inside.
○
bottom part of the ○ The plinth bottom allows fixing
○
enclosure for fixing of ○ ○ ○ to floor through MFPLAZ
various equipment ground fixing frame.
through M8 inserts
TEX8.
HIMEL 81
floor standing polyester cabinets PLA
IP-65 (EN 60.529)
2 2 2 2 C-42
1
1 1 1 1
A-95
A-95
A-95
A-95
A-253
A-253
4 4 4 4
A-200
1 1 1 1
A-150
A-150
A-150
A-150
260
A
C-13
C-140
A-255
37,5 37,5 75 75
25
25
25
25
28,5 28,5
B-150 B-150 B-150 B-150
21
C
3
B-120 3 B-120
17 / 28*
* for reinforced
37
mounting plates
1 1
C-140
C-140
M8 1 M8
3
C-125 3
40
C-125
B-295 B-295
1 1 1
4
B = 500 / 750 405 4 405/655
500 500/750
B =1000/1250
1 Bosses on the back of cabinets as from 1000 mm wide allow fixing of partial 2 Bosses with M8 inserts for fixing of mounting plate.
mounting plates (see relevant section). Bosses at the top and bottom are for fixing
3 Centres for floor or plinth fixing.
of depth adjustable supports, internal doors, 19 " racks. In general, all bosses
including those on sides and doors are prepared for M8 inserts ref.: TEX 8 for fixing 4 Centres of door opening.
of various equipment.
82 HIMEL
floor standing polyester cabinets PLA
IP-65 (EN 60.529)
2 2 C-42
1
A-95
A-95
1 1
4 4
A-200
B-95 B-95 C-170
1 1
A+55
A-150
A-150
260
C-8
C-140
37,5
A-255
75
25
25
55
1 Bosses on the back of cabinets as from 1000 mm wide
B-150 B-150 28,5 28,5
21
allow fixing of partial mounting plates (see relevant
C
section). Bosses at the top and bottom are for fixing of
3 3
* for reinforced depth adjustable supports, internal doors, 19 " racks.
B-60 B-60
23 / 28*
mounting plates In general, all bosses including those on sides and
37
M8
C-160 3
M8
C-160
C-68
B-81 B-81
2 Bosses with M8 inserts for fixing of mounting plate.
PLAZ...TR ribbed door and back ■ wide range of operating temperatures -50
polyester cabinets, self-ventilated canopy to 150oC.
topand open plinth bottom IP-44 ■ resistant to main chemical agents and
Hot-moulded reinforced polyester cabinets corrosive environments.
■ door and back with curved surfaces ■ resistant to ultraviolet light.
making difficult to stick posters. ■ suitable for double insulation assemblies
■ grey RAL 7032. conforming to standard IEC 439-1
■ self-ventilated cabinet. (EN 60.439.1).
■ conforms to general rules for empty ■ prepared for outside applications and
enclosures established by standard public sites according to IEC 439-5
EN 50298. (EN 60.439.5) standard.
■ IP-44 according to IEC-529 (EN 60.529). ■ reversible door with 1200 opening. Max.
Possibility to upgrade to IP-54 through JPLA load 30 kg/m2.
gasket. ■ lock outside the gasketed area with 2-point
■ high degree of resistance to mechanical locking system on cabinets up to 750 mm
■ bosses for M8 inserts inside of the cabinet
impacts IK10 (20J) according to EN 50.102. high an 4-point as from 1000 mm.
for direct fixing of mounting plates,
■ self-extinguishing, according to ■ allow direct fixing to root burying plinths
accessories, etc.
IEC 695-2-1(960o). ZHPLA.
■ wall fixing through FMPLA brackets.
Composition
38
2 2 C-42
1
1
■ open top with canopy.
A-95
1
A-95
A-150
260
C-8
forcing of the door.
C-140
■ double bar standard lock. Other lock
37,5
transformations are available.
A-255
75
55
* for reinforced
mounting plates. are prepared for M8 inserts ref.: TEX 8 for fixing of
40
various equipment.
C-68
M8
3
M8
C-160
C-160
C-68
B-81
B-81
2 Bosses with M8 inserts for fixing of mounting plate.
6.5 B = 500/750 6.5 405 4 405/655 4 3 Centres for floor or plinth fixing.
500 500/750
HIMEL 83
selection guide for PLA
polyester cabinets
nominal
n°.
dimensions (mm).
doors
height width depth
500 500 320 1 PLA 553 PLA 553 R PLA 553 KT PLA 553 T PLA 553 TR
420 1 PLA 554 PLA 554 R PLA 554 KT PLA 554 T PLA 554 TR
750 320 1 PLA 573 PLA 573 R PLA 573 KT PLA 573 T PLA 573 TR
420 1 PLA 574 PLA 574 R PLA 574 KT PLA 574 T PLA 574 TR
1000 320 2 PLA 5103 PLA 5103 R PLA 5103 KT PLA 5103 T PLA 5103 TR
420 2 PLA 5104 PLA 5104 R PLA 5104 KT PLA 5104 T PLA 5104 TR
1250 320 2 PLA 5123 PLA 5123 R PLA 5123 KT PLA 5123 T PLA 5123 TR
420 2 PLA 5124 PLA 5124 R PLA 5124 KT PLA 5124 T PLA 5124 TR
750 500 320 1 PLA 753 PLA 753 R PLA 753 KT PLA 753 T PLA 753 TR
420 1 PLA 754 PLA 754 R PLA 754 KT PLA 754 T PLA 754 TR
750 320 1 PLA 773 PLA 773 R PLA 773 KT PLA 773 T PLA 773 TR
420 1 PLA 774 PLA 774 R PLA 774 KT PLA 774 T PLA 774 TR
1000 320 2 PLA 7103 PLA 7103 R PLA 7103 KT PLA 7103 T PLA 7103 TR
420 2 PLA 7104 PLA 7104 R PLA 7104 KT PLA 7104 T PLA 7104 TR
1250 320 2 PLA 7123 PLA 7123 R PLA 7123 KT PLA 7123 T PLA 7123 TR
420 2 PLA 7124 PLA 7124 R PLA 7124 KT PLA 7124 T PLA 7124 TR
1000 500 320 1 PLA 1053 PLA 1053 R PLA 1053 KT PLA 1053 T PLA 1053 TR
420 1 PLA 1054 PLA 1054 R PLA 1054 KT PLA 1054 T PLA 1054 TR
750 320 1 PLA 1073 PLA 1073 R PLA 1073 KT PLA 1073 T PLA 1073 TR
420 1 PLA 1074 PLA 1074 R PLA 1074 KT PLA 1074 T PLA 1074 TR
1000 320 2 PLA 10103 PLA 10103 R PLA 10103 KT PLA 10103 T PLA 10103 TR
420 2 PLA 10104 PLA 10104 R PLA 10104 KT PLA 10104 T PLA 10104 TR
1250 320 2 PLA 10123 PLA 10123 R PLA 10123 KT PLA 10123 T PLA 10123 TR
420 2 PLA 10124 PLA 10124 R PLA 10124 KT PLA 10124 T PLA 10124 TR
1250 500 320 1 PLA 1253 PLA 1253 R PLA 1253 KT PLA 1253 T PLA 1253 TR
420 1 PLA 1254 PLA 1254 R PLA 1254 KT PLA 1254 T PLA 1254 TR
750 320 1 PLA 1273 PLA 1273 R PLA 1273 KT PLA 1273 T PLA 1273 TR
420 1 PLA 1274 PLA 1274 R PLA 1274 KT PLA 1274 T PLA 1274 TR
1000 320 2 PLA 12103 PLA 12103 R PLA 12103 KT PLA 12103 T PLA 12103 TR
420 2 PLA 12104 PLA 12104 R PLA 12104 KT PLA 12104 T PLA 12104 TR
1250 320 2 PLA 12123 PLA 12123 R PLA 12123 KT PLA 12123 T PLA 12123 TR
420 2 PLA 12124 PLA 12124 R PLA 12124 KT PLA 12124 T PLA 12124 TR
1500 500 320 1 PLA 1553 PLA 1553 R PLA 1553 KT PLA 1553 T PLA 1553 TR
420 1 PLA 1554 PLA 1554 R PLA 1554 KT PLA 1554 T PLA 1554 TR
750 320 1 PLA 1573 PLA 1573 R PLA 1573 KT PLA 1573 T PLA 1573 TR
420 1 PLA 1574 PLA 1574 R PLA 1574 KT PLA 1574 T PLA 1574 TR
1000 320 2 PLA 15103 PLA 15103 R PLA 15103 KT PLA 15103 T PLA 15103 TR
420 2 PLA 15104 PLA 15104 R PLA 15104 KT PLA 15104 T PLA 15104 TR
1250 320 2 PLA 15123 PLA 15123 R PLA 15123 KT PLA 15123 T PLA 15123 TR
420 2 PLA 15124 PLA 15124 R PLA 15124 KT PLA 15124 T PLA 15124 TR
84 HIMEL
plinth type, open at bottom self-ventilating top with canopy
and open plinth-type bottom
transparent plain embossed transparent plain embossed transparent
door door door door door door door
handle flat flat flat handle handle handle
120o 180o
IP-54 IP-44
PLA 553 TKT PLAZ 553 PLAZ 553 R PLAZ 553 KT PLAZ 553 T PLAZ 553 TR PLAZ 553 TKT
PLA 554 TKT PLAZ 554 PLAZ 554 R PLAZ 554 KT PLAZ 554 T PLAZ 554 TR PLAZ 554 TKT
PLA 573 TKT PLAZ 573 PLAZ 573 R PLAZ 573 KT PLAZ 573 T PLAZ 573 TR PLAZ 573 TKT
PLA 574 TKT PLAZ 574 PLAZ 574 R PLAZ 574 KT PLAZ 574 T PLAZ 574 TR PLAZ 574 TKT
PLA 5103 TKT PLAZ 5103 PLAZ 5103 R PLAZ 5103 KT PLAZ 5103 T PLAZ 5103 TR PLAZ 5103 TKT
PLA 5104 TKT PLAZ 5104 PLAZ 5104 R PLAZ 5104 KT PLAZ 5104 T PLAZ 5104 TR PLAZ 5104 TKT
PLA 5123 TKT PLAZ 5123 PLAZ 5123 R PLAZ 5123 KT PLAZ 5123 T PLAZ 5123 TR PLAZ 5123 TKT
PLA 5124 TKT PLAZ 5124 PLAZ 5124 R PLAZ 5124 KT PLAZ 5124 T PLAZ 5124 TR PLAZ 5124 TKT
PLA 753 TKT PLAZ 753 PLAZ 753 R PLAZ 753 KT PLAZ 753 T PLAZ 753 TR PLAZ 753 TKT
PLA 754 TKT PLAZ 754 PLAZ 754 R PLAZ 754 KT PLAZ 754 T PLAZ 754 TR PLAZ 754 TKT
PLA 773 TKT PLAZ 773 PLAZ 773 R PLAZ 773 KT PLAZ 773 T PLAZ 773 TR PLAZ 773 TKT
PLA 774 TKT PLAZ 774 PLAZ 774 R PLAZ 774 KT PLAZ 774 T PLAZ 774 TR PLAZ 774 TKT
PLA 7103 TKT PLAZ 7103 PLAZ 7103 R PLAZ 7103 KT PLAZ 7103 T PLAZ 7103 TR PLAZ 7103 TKT
PLA 7104 TKT PLAZ 7104 PLAZ 7104 R PLAZ 7104 KT PLAZ 7104 T PLAZ 7104 TR PLAZ 7104 TKT
PLA 7123 TKT PLAZ 7123 PLAZ 7123 R PLAZ 7123 KT PLAZ 7123 T PLAZ 7123 TR PLAZ 7123 TKT
PLA 7124 TKT PLAZ 7124 PLAZ 7124 R PLAZ 7124 KT PLAZ 7124 T PLAZ 7124 TR PLAZ 7124 TKT
PLA 1053 TKT PLAZ 1053 PLAZ 1053 R PLAZ 1053 KT PLAZ 1053 T PLAZ 1053 TR PLAZ 1053 TKT
PLA 1054 TKT PLAZ 1054 PLAZ 1054 R PLAZ 1054 KT PLAZ 1054 T PLAZ 1054 TR PLAZ 1054 TKT
PLA 1073 TKT PLAZ 1073 PLAZ 1073 R PLAZ 1073 KT PLAZ 1073 T PLAZ 1073 TR PLAZ 1073 TKT
PLA 1074 TKT PLAZ 1074 PLAZ 1074 R PLAZ 1074 KT PLAZ 1074 T PLAZ 1074 TR PLAZ 1074 TKT
PLA 10103 TKT PLAZ 10103 PLAZ 10103 R PLAZ 10103 KT PLAZ 10103 T PLAZ 10103 TR PLAZ 10103 TKT
PLA 10104 TKT PLAZ 10104 PLAZ 10104 R PLAZ 10104 KT PLAZ 10104 T PLAZ 10104 TR PLAZ 10104 TKT
PLA 10123 TKT PLAZ 10123 PLAZ 10123 R PLAZ 10123 KT PLAZ 10123 T PLAZ 10123 TR PLAZ 10123 TKT
PLA 10124 TKT PLAZ 10124 PLAZ 10124 R PLAZ 10124 KT PLAZ 10124 T PLAZ 10124 TR PLAZ 10124 TKT
PLA 1253 TKT PLAZ 1253 PLAZ 1253 R PLAZ 1253 KT PLAZ 1253 T PLAZ 1253 TR PLAZ 1253 TKT
PLA 1254 TKT PLAZ 1254 PLAZ 1254 R PLAZ 1254 KT PLAZ 1254 T PLAZ 1254 TR PLAZ 1254 TKT
PLA 1273 TKT PLAZ 1273 PLAZ 1273 R PLAZ 1273 KT PLAZ 1273 T PLAZ 1273 TR PLAZ 1273 TKT
PLA 1274 TKT PLAZ 1274 PLAZ 1274 R PLAZ 1274 KT PLAZ 1274 T PLAZ 1274 TR PLAZ 1274 TKT
PLA 12103 TKT PLAZ 12103 PLAZ 12103 R PLAZ 12103 KT PLAZ 12103 T PLAZ 12103 TR PLAZ 12103 TKT
PLA 12104 TKT PLAZ 12104 PLAZ 12104 R PLAZ 12104 KT PLAZ 12104 T PLAZ 12104 TR PLAZ 12104 TKT
PLA 12123 TKT PLAZ 12123 PLAZ 12123 R PLAZ 12123 KT PLAZ 12123 T PLAZ 12123 TR PLAZ 12123 TKT
PLA 12124 TKT PLAZ 12124 PLAZ 12124 R PLAZ 12124 KT PLAZ 12124 T PLAZ 12124 TR PLAZ 12124 TKT
PLA 1553 TKT PLAZ 1553 PLAZ 1553 R PLAZ 1553 KT PLAZ 1553 T PLAZ 1553 TR PLAZ 1553 TKT
PLA 1554 TKT PLAZ 1554 PLAZ 1554 R PLAZ 1554 KT PLAZ 1554 T PLAZ 1554 TR PLAZ 1554 TKT
PLA 1573 TKT PLAZ 1573 PLAZ 1573 R PLAZ 1573 KT PLAZ 1573 T PLAZ 1573 TR PLAZ 1573 TKT
PLA 1574 TKT PLAZ 1574 PLAZ 1574 R PLAZ 1574 KT PLAZ 1574 T PLAZ 1574 TR PLAZ 1574 TKT
PLA 15103 TKT PLAZ 15103 PLAZ 15103 R PLAZ 15103 KT PLAZ 15103 T PLAZ 15103 TR PLAZ 15103 TKT
PLA 15104 TKT PLAZ 15104 PLAZ 15104 R PLAZ 15104 KT PLAZ 15104 T PLAZ 15104 TR PLAZ 15104 TKT
PLA 15123 TKT PLAZ 15123 PLAZ 15123 R PLAZ 15123 KT PLAZ 15123 T PLAZ 15123 TR PLAZ 15123 TKT
PLA 15124 TKT PLAZ 15124 PLAZ 15124 R PLAZ 15124 KT PLAZ 15124 T PLAZ 15124 TR PLAZ 15124 TKT
HIMEL 85
selection guide for PLA
polyester cabinets
external
n°. metal insulating perforated set of 2 modular distribution
dimensions (mm)
of mounting mounting mounting uprights for chassis
doors plate plate plate universal chassis
height width depth reference
86 HIMEL
n°. of
18 mm. fixed swing internal
bases (1) plinths (2) canopies
units doors
HIMEL 87
accessories for PLA
polyester cabinets
10,5 25 25 10,5 25 25 e
25
25
Ø 6,5
Ø6,5 Ø6,5
Ø8,5 Ø8,5 Ø 8,5
25
25
25
Ø 8,5 Ø 6,5
25
10,5
25 25
D
F
100
100
10,5
75
75
150
G 350 150 H-87,5 12,5
E 437,5 H
E
as from
fig. 1 fig. 2 PMM1010
(1) Cabinets 1000, 1250 and 1500 mm high allow the following partial mounting plates: 2 PMM 500 mm high; 1 × 500 + 1 × 750 or 2 × 750 mm. high respectively, all
fixed to the back of the cabinet.
88 HIMEL
accessories for PLA
polyester cabinets
10,5 10,5 e
10,5
D
F
100
100
75 10,5
75
150
G 350 150 H-87,5
E 437,5 H
E
fig. 1 fig. 2
(1) Cabinets 1000, 1250 and 1500 mm high allow the following partial mounting plates: 2 PMB 500 mm high; 1 × 500 + 1 × 750 or 2 × 750 mm. high respectively, all
fixed to the back of the cabinet.
HIMEL 89
accessories for PLA
polyester cabinets
15
perforated mounting plates
Specially designed for quick fixing of
equipment through nuts TFP. Made of
bichromated zinc steel.
Fit directly to the back of the cabinets on the
depth adjustable supports. On 2-door
cabinets, a full or 2 partial plates can be
fitted (see chart).
Cabinets as from 1000 mm high are
provided with bosses in the middle for fitting
PMR plates shorter than the nominal height
D
F
G
E
(1) Cabinets 1000, 1250, and 1500 mm high allow the following partial boards; 2 PMR (500); 1 off 500 + 1 off 750 or 2 off 750 mm + height (respectively), all
fixed to the back of the cabinet.
mounting plate depth adjustable On models with open plinth bottom a set of
supports PTZ plates must be ordered as well as the
Allow for depth adjustement of PMM, PMB DPLA supports.
and PMR mountings plates in any cabinet.
On models with closed bottom PLA...
supports can be fitted directely.
90 HIMEL
accessories for PLA
polyester cabinets
DLP distribution frame kit for modular switch ■ distances between symmetrical switch ■ connector block for neutral and earth
gear, designed for attachment to all PLA gear fixing profile and interior protective connections reference RBLZ/21656
enclosure models. cover plate of 40 to 85 mm, adjustable (included in the standard order).
■ insulating cover plate and frame in self- depending on user requirements. ■ option of fitting mounting plates and blank
extinguishing material, colour RAL 7032. fascias for installation of a variety of items.
(500) (500)
for fitting individual row layout blind cover plate mounting plate blanking plate
to enclosures frames for
circuit breaker rails
two-door enclosures
height width n°. chasis total reference* n°. qty. model n°.
(A) (B) doors reference* rows n°. plates
18 mm.
750 500 1 DLP 76 - 4 4 76 - CTL500/DLP PMP500/DLP
750 500 1 DLP 57 - 4 3 57 1 CTL5002/DLP
750 750 1 DLP 132 - 4 4 132 - CTL750/DLP
PMP750/DLP
750 750 1 DLP 99 - 4 3 99 1 CTL7502/DLP
750 1000 2 - DLP 76+DLP 76 4+4 4+4 152 - CTL500/DLP + CTL500/DLP
PMP500/DLP + PMP500/DLP
DLP 57+DLP 57 4+4 3+3 114 1+1 CTL5002/DLP + CTL5002/DLP
750 1250 2 - DLP 76+DLP 132 4+4 4+4 208 - CTL500/DLP + CTL750/DLP ATP-6/DTM
PMP500/DLP + PMP750/DLP
DLP 57+DLP 99 4+4 3+3 156 1+1 CTL5002/DLP + CTL7502/DLP (108 mm)
1000 500 1 DLP 114 - 6 6 114 - CTL500/DLP 6 modules
PMP500/DLP
1000 500 1 DLP 95 - 6 5 95 1 CTL5002/DLP
1000 750 1 DLP 198 - 6 6 198 - CTL750/DLP
PMP750/DLP
1000 750 1 DLP 165 - 6 5 165 1 CTL7502/DLP
1000 1000 2 - DLP 114+DLP 114 6+6 6+6 228 - CTL500/DLP + CTL500/DLP
PMP500/DLP + PMP500/DLP
DLP 95+DLP 95 6+6 5+5 190 1+1 CTL5002/DLP + CTL5002/DLP
1000 1250 2 - DLP 114+DLP 198 6+6 6+6 312 - CTL500/DLR + CTL750/DLP
PMP500/DLP + PMP750/DLP
DLP 95+DLP 165 6+6 5+5 260 1+1 CTL5002/DLP + CTL7502/DLP
1250 500 1 DLP 133 - 7 7 133 - CTL500/DLP
PMP500/DLP
1250 500 1 DLP 114P - 7 6 114 1 CTL5002/DLP
1250 750 1 DLP 231 - 7 7 231 - CTL750/DLP PMP750/DLP
1250 750 1 DLP 198P - 7 6 198 1 CTL7502/DLP
1250 1000 2 - DLP 133+DLP 133 7+7 7+7 266 - CTL500/DLP + CTL500/DLP
PMP500/DLP + PMP500/DLP
DLP 114P+DLP 114P 7+7 6+6 228 1+1 CTL5002/DLP + CTL5002/DLP
1250 1250 2 - DLP 133+DLP 231 7+7 7+7 364 - CTL500/DLP + CTL750/DLP ATP-24/DTM
PMP500/DLP + PMP750/DLP (432 mm)
DLP 114P+DLP 198P 7+7 6+6 312 1+1 CTL5002/DLP + CTL7502/DLP
1500 500 1 DLP 171 - 9 9 171 - CTL500/DLP 24 modules
PMP500/DLP
1500 500 1 DLP 152 - 9 8 152 1 CTL5002/DLP
1500 750 1 DLP 297 - 9 9 297 - CTL750/DLP
PMP750/DLP
1500 750 1 DLP 264 - 9 8 264 1 CTL7502/DLP
1500 1000 2 - DLP 171+DLP 171 9+9 9+9 342 - CTL500/DLP + CTL500/DLP
PMP500/DLP + PMP500/DLP
1500 1000 2 - DLP 152+DLP 152 9+9 8+8 304 - CTL5002/DLP + CTL5002/DLP
1500 1250 2 - DLP 171+DLP 297 9+9 9+9 468 1+1 CTL500/DLP + CTL750/DLP
PMP500/DLP + PMP750/DLP
1500 1250 2 - DLP 152+DLP 264 9+9 8+8 416 1+1 CTL5002/DLP + CTL7502/DLP
* For fitting to enclosures with open bottom part, stock code PLAZ, adaptor plates should be ordered separately. Reference: PTZ 320 or PTZ 420, for one-door
enclosures 320 or 420 mm deep. For two-door enclosures, PTZ 320/2P or PTZ 420/2P should be ordered.
HIMEL 91
accessories for PLA
polyester cabinets
plinths
Designed to attach to enclosures with an B
open bottom, reference PLAZ...
Constructed in glass reinforced pressed
polyester. C
■ colour: grey similar to RAL 7032.
■ self-extinguishing; shockproof and high
temperature resistance.
■ double insulation; excellent weather
resistance.
■ 200 mm front accessible from inside.
200
92 HIMEL
accessories for PLA
polyester cabinets
internal door
constructed in RAL 7032 grey painted In models with open plinth-type base
aluminium. Double bar closing mechanisms. reference PLAZ... PTZ adaptor plates
For models with closed base reference should be ordered separately.
PLA... PIPLA internal doors attach directly.
for fitting internal door individual internal doors for two- dimensions
n°. door enclosures weight
to enclosures total
doors (Kg)
height (A) width (B) reference* reference* D E
500 500 1 PIPLA 55 - 398 398 1.6
500 750 1 PIPLA 57 - 398 648 2,2
500 1000 2 - PIPLA 55 + PIPLA 55 - - -
500 1250 2 - PIPLA 55 + PIPLA 57 - - -
750 500 1 PIPLA 75 - 648 398 2,2
750 750 1 PIPLA 77 - 648 648 3,1
750 1000 2 - PIPLA 75 + PIPLA 75 - - -
750 1250 2 - PIPLA 75 + PIPLA 77 - - -
1000 500 1 PIPLA 105 - 898 398 2,8
1000 750 1 PIPLA 107 - 898 648 4,1
1000 1000 2 - PIPLA 105 + PIPLA 105 - - -
1000 1250 2 - PIPLA 105 + PIPLA 107 - - -
1250 500 1 PIPLA 125 - 1148 398 3,4
1250 750 1 PIPLA 127 - 1148 648 5
1250 1000 2 - PIPLA 125 + PIPLA 125 - - -
1250 1250 2 - PIPLA 125 + PIPLA 127 - - -
1500 500 1 PIPLA 155 - 1398 398 4
1500 750 1 PIPLA 157 - 1398 648 6
1500 1000 2 - PIPLA 155 + PIPLA 155 - - -
1500 1250 2 - PIPLA 155 + PIPLA 157 - - -
* For fitting to enclosures with open bottom part, reference PLAZ... adapter plates should be ordered separately. Reference:
PTZ 320 or PTZ 420, for one-door enclosures 320 or 420 mm deep, respectively. For two-door enclosures, PTZ 320/2P or
PTZ 420/2P should be ordered.
cabinets.
187.5
26
B+52
HIMEL 93
accessories for PLA
polyester cabinets
standard lock for cabinets with transformations from standard lock to other versions
canopy
reference characteristics
Double bar handle lock supplied as
standard. Various inserts available.
TT7/OLN 7 mm triangular insert LT8 key.
TT8/OLN 8 mm triangular insert LT8 key..
standard lock for closed top transformations from standard lock to other versions
cabinets
reference characteristics
5 mm double bar lock with LDB5 key.
BC/PLA padlock
94 HIMEL
accessories for PLA
polyester cabinets
Robust system of 19" rack frame, intended ■ both fixed and swing racks can be 1 Fixed BRF 17 PLA rack, attached by
for direct mounting on all PLA enclosure installed as partial rack in higher than means of a set of two vertical supports
versions. normal enclosures. SPLA 100.
■ maximum load: 3 kg per unit up to a
■ fixed and swing racks permitting direct maximum of 40 kg for swing racks. 2 Pivoting BRF 16 PLA rack, attached by
installation of all types of 19" modular switch ■ finish: polyester-epoxy paint RAL 7032. means of a set of two vertical supports
gear using the standardized holes. ■ swing racks opening to 120°, 5 mm double SPLA 100.
■ fixing at the top and sides of enclosure bar key closing mechanism.
using SPLA vertical supports, which should 3 Pivoting BRP 7 PLA rack installed as a
be ordered separately. partial rack in the enclosure.
For enclosures 750 mm high or more. PLA 1074 rack, attached by means of a
set of two vertical supports SPLA 100.
1 2 3
For enclosures over 750 mm tall the set of 2 500* 750/1250 8 BRF 8PLA* 7 BRP 7PLA* -
SPLA vertical supports indicated in the table 750* 750/1250 12 BRF 12PLA* 11 BRP 11PLA* SPLA 75
should be ordered. 1000* 750/1250 17 BRF 17PLA* 16 BRP 16PLA* SPLA 100
1250* 750/1250 21 BRF 21PLA* 20 BRP 20PLA* SPLA 125
1500 750/1250 26 BRF 26PLA 25 BRP 25PLA* SPLA 150
19" pivoting frame
BRP rack designed to be fitted to all 750 and * Can be fitted in taller enclosures as a partial rack using the vertical supports corresponding to the desired height of the
enclosure. In all cases SPLA vertical supports must be ordered separately.
1200 mm wide 420 mm deep PLA models of
* For enclosures 1250 mm wide, the set of two supports must be ordered SPLA.
enclosure.*
For enclosures over 750 mm tall the set of 2
SPLA vertical supports indicated in the table
should be ordered.
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 95
din-distribution cabinets PLD - ZD
and pedestals in polyester
IP-43 self-ventilated
IP-54 watertight (EN 60.529)
1 M10 inserts for fixing of busbars, fuse bases 3 M8 inserts for fixing the supports of the depth 5 Lock on left and right door in model
and other equipment. adjustable plate ref.: TEX 8. PLD-812/2C.
2 M6 inserts for fixing the mounting plate, rails 4 Housing for the installation of ground mounting
and other equipment. supports ref.: SPLD. They allow for the insertion of
M8 nuts ref.: TE/PLD-M8 for fixing of equipment.
96 HIMEL
din-distribution cabinets PLD - ZD
and pedestals in polyester
IP-43 self-ventilated
IP-54 watertight (EN 60.529)
selection guide
enclosures mounting frame plinth
plates
mounting plates
For direct coupling to rear of PLD cabinet.
Possibility to adjust depth. See note about
using projections 3 on page 96.
■ insulating plates of black bakelite
RAL 9005.
HIMEL 97
din-distribution cabinets PLD - ZD
and pedestals in polyester
IP-43 self-ventilated
IP-54 watertight (EN 60.529)
PLD-85/00 ZD-53/00
PLD-86/0 ZD-63/0
PLD-88/1 ZD-83/1
PLD-812/2 and 2C ZD-123/2
98 HIMEL
din-distribution cabinets PLD - ZD
and pedestals in polyester
IP-43 self-ventilated
IP-54 watertight (EN 60.529)
cabinet L M
reference K max. max.
BCME/PL padlock
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 99
metal and insulated unction and modular distribution boxes
Junction boxes
This family of products covers a range of uses such as cable connections
and protection of electronic components.
metal insulated
D-DX DP-DPC CI-CIP-CIE CB
degree of protection IP-55 IP-55 IP-55/66 IP-65
n°. sizes/models 20/40 10/26 33/91 3/3
dimensions (mm) 85 × 85 × 49 to 83 × 83 × 50 to 105 × 105 × 66 to 295 × 195 × 128 to
357 × 307 × 210 389 × 310 × 128 350 × 280 × 164 495 × 195 × 128
type of construction
insulated ABS PVC/Polycarbonate Polyester/Polycarbonate
enclosure
mechanical c
features
side walls
with cones c
with knockouts c c c
plain c c
covers c
opaque c c c c
transparent c c
mounting plates c c c c
page 104 105 106 - 107 106 - 107
102 HIMEL
modular distribution boxes
sealed boxes
DTH DSUN DTUN
degree of protection IP-55 IP-40/42 IP-40/55
n°. sizes/models 3/3 6/17 10/20
characteristics
18 mm modules up to 12 up to 30 up to 36
enclosure
fixing c
system
recess mounting c c
surface c c c
door
transparent c c c
opaque c c
n°. door c
page 108 109 108 - 109
HIMEL 103
metal junction boxes D - DX
IP-55 (EN 60.529) except models with knockouts
metal boxes D
Constructed in sheet steel protected
internally and externally with textured
epoxy-polyester paint, RAL 7032.
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
104 HIMEL
insulated junction boxes DP - DPC
IP-55 (EN 60.529)
C
B
tubes.
To fit to DP... plastic junction boxes.
Ø max.
reference ØA ØB ØC ØD E F tube
ECDPC 1 28 24 20,8 8,8 2,3 15,4 20
ECDPC 2 35 28 24,7 8,8 2,3 15,4 25
ECDPC 3 43,6 38 33,1 8,9 3,2 18,4 32
ECDPC 4 56,5 47 45,6 24,3 3,4 18,4 45
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 105
insulated industrial boxes CI - CIP
IP-66 (EN 60.529)
CIE - CB
106 HIMEL
accessories for CI - CIP
insulated industrial boxes
CIE - CB
internal hinges
Reference: BICI for fitting to CI 1710 - 1713
- 2216 models.
Reference: BICI 2722 for fitting to CI 2722 -
3125 models.
CB boxes specially designed for industrial ■ wall fixing brackets ref.: FM/DTH.
use. ■ double insulated.
■ IP-65, IK-9. ■ halide-free material.
■ glass-fibre reinforced polyester base and ■ heat resistant (incandescent wire test
lid for greater rigidity. at 960°C).
■ sides and cable glands in glass-fibre 3 modes of wall mounting:
reinforced polycarbonate. ■ directly on the inside of the box.
■ removable cable gland plates for ease of ■ using the 4 holes in the corners under
access to terminals thus simplifying cabling. the lid holding screws.
■ captive plastic screws security sealable ■ using wall brackets.
to lid. ■ tapped rails ref.: RT/CB, set of 2 tapped
■ polyurethane seal between the base and rails designed for a quick fixing to the
the lid. self-positioning slots.
■ elastomer seal ensuring seal between
side cable gland plates of the box.
■ drill holes 25 mm apart in the base and
50 mm apart in the lid for fixing accessories models, dimensions and references
(mounting plates, etc.)
external dimensions (mm) mounting symmetrical asymmetric coupling
■ height adjustment slots for accessories. reference plate rails rails rack
■ lid holder supplied as standard. height width depth
■ coupling rack to join two boxes while 295 195 128 CB3020 PMCB3020 COCB3020 CACB3020 CU3020/CB
maintaining the IP degree of the unit as a 395 195 128 CB4020 PMCB4020 COCB4020 CACB4020 CU4020/CB
495 195 128 CB5020 PMCB5020 COCB5020 CACB5020 CU5020/CB
whole.
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 107
sealed modular distribution DTH - DTU
IP-55 (EN 60.529)
HM 24 H8
175 83 111 H3 3 1 - - - 1 - - - - -
175 125 111 H5 5 1 - 2 - 2 - - - 2 -
175 215 111 H8 8 1 - - - 3 - - - 2 -
200 287 119 H12 12 1 2 2 1 - - - - - -
250 285 136 HM12 12 1 - - - 4 1 - 2 - PM12
375 285 136 HM24 24 2 - - - 4 1 - 3 - PM24
500 285 136 HM36 36 3 - - - 4 - 1 4 - PM36
375 285 136 HM24C 12 1 - - - 4 1 - 3 - PM24
500 285 136 HM36C 12 1 - - - 4 - 1 4 - PM36
125 285 136 HMC 12 1 - - - - - - - - -
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
108 HIMEL
sealed insulated distribution boxes DTUN - DSUN
IP-40 (EN 60.529)
207 244 1 9 AE 9/N AEP 9/N AEP 9/N PT - ASP 9/N ASP 9/N PT
207 352 1 15 AE 15/N AEP 15/N AEP 15/N PT - ASP 15/N ASP 15/N PT
332 352 2 30 AE 30/N AEP 30/N AEP 30/N PT - ASP 30/N ASP 30/N PT
175 200 1 9 - - - AS 9/N - -
175 310 1 15 - - - AS 15/N - -
350 310 2 30 - - - AS 30/N - -
Look up these and other accessories at the Himel general catalogue and at our web site www.himelenclosures.com.
HIMEL 109
thermal control products
Environmental friendliness
The miniaturisation of components, the widespread use of electronics and
the appearance of new power electronic base products make temperature
management a constraint similar to IP, which must more and more
frequently be taken into account in the design of electrical and/or electronic
switchboards.
Reliability and minimum failure rates are two determining factors in process
industries in which the hourly cost of installation operations is extremely
high; any failure immediately creates losses which may reach considerable
amounts.
The life of the component itself depends upon temperature and humidity
conditions in the enclosure: the ideal temperature is between + 10 to +
40 ºC with a relative humidity (RH) of 30 to 90 %.
cool
ventilate
cooling units
VF CLT… CLL…
no models 16 9 9
functions exterior fan top mounting side panel mounting
interior fan
19" rack fan
characteristics
power
electrical (W) 11 to 155 380 to 1850 290 to 1000
refrigeration (W) 600 to 3100 290 to 1800
3
flow rate (m /h) 24 to 1200
112 HIMEL
The high degree of protection (IP-54), their The CLT-CLL air-conditioning units
ease of installation and efficient operation provide optimal performance in industrial
mean the VF fans prolong and protect the installations thanks to the possibility of
life of the components installed in the interior installing them in environments with a
of the enclosure. temperature of up to 55°C.
cool heat
control devices
exchangers
(air- (air-
ICT/ICL water) ICT/ICL air) RC TS
2 5 10 5
top mounting top mounting 2 models with built-in fans thermostat: temperature adjustable
side panel mounting top mounting from 0° to 60°C
hygrometer: temperature adjustable
from 0° to 60°C
relative humidity adjustable
from 50 to 90 %
hygrostat: relative humidity adjustable
from 30 to 100 %
90 150 10 to 500
1800 15 to 70
HIMEL 113
thermal control for electrical guide for calculating a
thermal auxiliary
switchboards
calculation method for determining Thermal equilibrium consists of comparing auxiliary to be determined and makes it
thermal management of an electrical the power dissipated by the components possible to decide whether it is necessary
panel. of the installation and that released to install a unit, bearing in mind the desired
spontaneously by the walls of the enclosure. internal and external temperatures.
This allows the internal temperature A simple technique is described below:
obtained in the enclosure with a thermal
intermediate in case of juxtaposition, located S = 1.4 × B × A +0.7 × B × C + C × A Type of installation: Enclosure placed
against a wall and with top covered against a wall.
S= m2 . S = 4.13 m2.
Condensation temperature. Tr = o
C Tr = 29oC
5.- Final temperature inside the enclosure with no auxiliary thermal unit:
It is necessary to cool
114 HIMEL
thermal control for electrical guide for calculating a
thermal auxiliary
switchboards
Td min. < Ti min. Td min. > Ti min. Td max. < Ti max. Td max. > Ti max.
There is no need for a thermal auxiliary as It is necessary to install a thermal auxiliary: It is necessary to install a thermal auxiliary. There is no need for a thermal auxiliary:
a fan can be used if necessary to keep the heating resistor This could be either a fan, a heat if necessary a fan can be used for air
temperature uniform. exchanger or a air-conditioning unit. circulation so as to avoid hot spots.
1/ permanent operation of the panel:
Psis= KxS (Td min − Te min) − Pd Psis = Pd − KxS (Td max − Te max)
ventilate
Avoid hot spots Install air-circulation fans A maintenance-free, low-cost The amount of heat removed is
inside the enclosure solution, which is easy to install and relatively little.
preserves the IP rating of the
installation.
cool
temperature conditions solution advantages of the solution disadvantages
Over-dimension the A maintenance-free, low-cost solution, which The amount of heat removed is relatively
enclosure. is easy to install and preserves the IP rating slight. The dimensions are not always
of the installation. compatible with the installation.
The final temperature Td max
desired in the enclosure is at least
5ºC lower than the maximum Fit ventilation louvres. Low-cost maintenance-free solution. The amount of heat removed is slight
ambient temperature Te. Easy to install. and depends on the arrangement of
the components. Reduces the IP rating
(dust penetration).
Install fans to draw in An economical solution which is easy to Maintenance and periodic cleaning
cool air. install. It removes a greater quantity of heat of the filters. Can reduce the IP
and temperature control is possible. rating in some cases.
Use an air/air heat exchanger. Simple to install. The IP rating of the installation Maintenance and periodic cleaning
is maintained. Temperature control is a of the filters.
standard feature. Easy to maintain.
Use an air-conditioning Simple to install, this solution allows large Maintenance and periodic cleaning of
The final temperature Td max unit. quantities of heat to be removed even when the the filters. It cannot be used when the
desired in the enclosure is ambient temperature is high. The IP rating of ambient temperature is above 55ºC.
lower than the maximum the installation is preserved and temperature
ambient temperature Te. control is standard.
Use an air/water heat Simple to install, this solution allows large A water circuit is needed and the
exchanger. quantities of heat to be removed even when water consumption is high.
the ambient temperature is high. The IP rating
of the installation is preserved and temperature
control is standard.
Td max ≤ Te max + 5oC.
Heat
Exterior temperature below the Economical, reliable, and allows the Power consumption. Occupies
Heat using a heating resistor. temperature of the panel to be controlled.
minimum temperature permissible space inside the enclosure.
for the components.
Heat with a heating resistor to Economical, reliable, and allows the Power consumption. Occupies
Condensation risk. maintain the temperature above humidity of the panel to be controlled. space inside the enclosure.
the condensation temperature.
HIMEL 115
forced and natural ventilation devices VF
The range of forced ventilation devices Determining the fan + outlet grill unit
offers a wide range of solutions adapted to with the aid of a graph.
all industrial applications.
fans: VF. 4
2
Surface de
Enclosure
l’enveloppe
surface
en m2 in
30
c full range of louvres and natural aeration
windows for cases where only a small
amount of power needs to be dissipated.
A variety of economic solutions to the (W) 2000 1500 1000
800 W
500 0 100 200 300
425m3/h
400
switchboards.
116 HIMEL
forced and natural ventilation devices VF
;@Q
QQ
@@
;;
230 - 17 V 65 - - FS 65 F 65 -
115 - 17 V 65/115 - - FS 65 F 65 -
230 - 11 VF 24 - - FS 24 F 24 -
- 24 2.4 VF 24/24 DC - - FS 24 F 24 -
230 - 18 VF 56 - - FS 56 F 56 FF 56
- 24 5 VF 56/24 DC - - FS 56 F 56 FF 56
- 48 5 VF 56/48 DC - - FS 56 F 56 FF 56
115 - 20 VF 56/115 - - FS 56 F 56 FF 56
230 - 18 VF 130 - - FS 130 F 130 FF 130
115 - 18 VF 130/115 - - FS 130 F 130 FF 130
- 24 4.7 VF 130/24 DC - - FS 130 F 130 FF 130
- 48 4.7 VF 130/48 DC - - FS 130 F 130 FF 130
230 - 46 VF 250 - - FS 130 F 130 FF 130
115 - 46 VF 250/115 - - FS 130 F 130 FF 130
- 24 12 VF 250/24 DC - - FS 130 F 130 FF 130
- 48 12 VF 250/48 DC - - FS 130 F 130 FF 130
230 - 70 VF 460 - - FS 460 F 460 FF 460
115 - 70 VF 460/115 - - FS 460 F 460 FF 460
230 - 155 VF 625N - - FS 460 F 460 FF 460
115 - 155 VF 625N/115 - - FS 460 F 460 FF 460
400 - 155 VF 625N/400 - - FS 460 F 460 FF 460
230 - 17 VC 150 - - - - -
230 - 34 - VR 312 - - - -
230 - 45 - VR 400 - - - -
230 - 68 - VR 624 - - - -
230 - 90 - VR 800 - - - -
230 - 135 - VR 1200 - - - -
230 - 37 - VTR 300 - - - -
230 - 85 - - VFT 400 - - -
HIMEL 117
natural ventilation systems VF
340 90 6
270 68 22
190
ø7
6
VET 12
découpe
cutting et
surface
entr'axe de fixation
and fixing axis.
228
290,5
270
270
340
228
A
F F
=
U
B
=
Ø5,3
D
E
air-vents
To connect the interior of the enclosure with
the outside in order to prevent condensation.
Can be fitted on the outside, ref.: VM-25 and
VM-27, or on the internal side walls that
connect with the rear self-ventilation
windows of POLYMEL enclosures,
ref.: VM-35.
reference characteristics
118 HIMEL
forced ventilation systems VF
fans
Turbine type motor fan for ventilation/
extraction. For fitting to the cable entries of
the various enclosure models.
ø4,2
ø4,2
ø1
14
104,8
ø7
71,5
8
104,8 71,5
HIMEL 119
cooling units CLT - CLL
general characteristics:
c desired interior temperature can be
controlled from +20°C to 50°C.
c automatic reset pressurestat which
detects overpressure, cuts off the fan from
the external circuit and the compressor and
connects an alarm.
c exterior and interior air circuits separated
(IP-54). The interior circuit fan runs
permanently to prevent hot spots forming
in the installation.
c included in the standard order: drilling
template, instructions for assembly and
installation, seal, condensation outlet pipe.
c convenient and easy to dismantle,
enabling cleaning and maintenance of the
unit.
120 HIMEL
cooling units CLT - CLL
reference
CLT 760 CLT 1050 CLT 1460 CLT 1650 CLT 1650T CLT 2450T CLT 3100T
external dimensions height × width × depth 340 × 600 × 350 400 × 700 × 400 400 × 700 × 400 430 × 700 × 400 430 × 700 × 400 470 × 800 × 450 470 × 800 × 450
refrigerating power DIN 3168 L 35 - L 35* 720 W 1050 W 1460 W 2000 W 1650 W 2450 W 3100W
refrigerating power DIN 3168 L 35 - L 50* 600 W 840 W 1180 W 1650 W 1400 W 1960 W 2500 W
air flow in internal circuit 350 m3/h 430 m3/h 430 m3/h 550 m3/h 550 m3/h 750 m3/h 750 m3/h
air flow in external circuit 350 m3/h 570 m3/h 570 m3/h 620 m3/h 620 m3/h 1200 m3/h 1200 m3/h
maximum pressure reached 1,6 MPa 1,8 MPa 1,8 MPa 1,8 MPa 1,8 MPa 1,8 MPa 1,8 MPa
weight of apparatus 33 kg 41 kg 45 kg 47 kg 60 kg 65 kg 65 kg
temperature control range 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC
operating temperature range 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC
3 × 400V - 50 Hz 3 × 400V - 50 Hz 3 × 400V - 50 Hz
supply voltage* 230V - 50/60 Hz 230V - 50/60 Hz 230V - 50/60 Hz 230V - 50/60 Hz 3 × 440V - 60 Hz 3 × 440V - 60 Hz 3 × 440V - 60 Hz
nominal/starting current 8 / 2,4 A 11 / 2,9 A 16 / 4,2 A 18 / 4,6 A 10 / 2,3 A 14,5 / 2,8 A 14,5 / 3,4 A
electrical power consumption L 35 - L 35 380 W 500 W 700 W 800 W 800 W 1200 W 1500 W
electrical power consumption L 35 - L 50 450 W 650 W 900 W 1000 W 1000 W 1500 W 1850 W
IP internal / external circuit IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34
* Air-conditioning units comply to standard DIN 3168 and European standard EN 814.
reference
CLL 240 CLL 370 CLL 760 CLL 1050 CLL 1650 CLL 1650T
external dimensions height × width × depth.5 450 × 350 × 140 620 × 300 × 170 800 × 350 × 195 900 × 400 × 195 1000 × 400 × 220 1000 × 400 × 220
refrigerating power DIN 3168 L 35 - L 35* 240 W 370 W 760 W 1050 W 1650 W 1800 W
refrigerating power DIN 3168 L 35 - L 50* 170 W 290 W 600 W 840 W 1400 W 1500 W
air flow in internal circuit 180 m3/h 160 m3/h 350 m3/h 350 m3/h 550 m3/h 550 m3/h
air flow in external circuit 330 m3/h 210 m3/h 350 m3/h 510 m3/h 620 m3/h 620 m3/h
maximum pressure reached 1,8 MPa 1,8 MPa 1,8 MPa 1,8 MPa 1,8 MPa 1,8 MPa
weight of apparatus 11 kg 21 kg 33 kg 39 kg 42 kg 46 kg
temperature control range 20 - 45oC 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC
operating temperature range 20 - 50oC 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC
3 × 400V - 50 Hz
supply voltage* 230V - 50/60 Hz 230V - 50/60 Hz 230V - 50/60 Hz 230V - 50/60 Hz 230V - 50/60 Hz 3 × 440V - 60 Hz
nominal/starting current 0,8 / 3,5 A 6 / 1,6 A 8 / 2,4 A 11 / 2,9 A 18 / 4,6 A 10 / 2,3 A
electrical power consumption L 35 - L 35 140 W 290 W 380 W 500 W 800 W 800 W
electrical power consumption L 35 - L 50 180 W 340 W 450 W 650 W 1000 W 1000 W
filter in external circuit optional yes yes yes yes yes
IP internal / external circuit IP-54 /IP-34 IP-54 /IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34
* Air-conditioning units comply to standard DIN 3168 and European standard EN 814.
for fitting
reference
to units
HIMEL 121
electronically controlled CLLMP
cooling units
CLTMP
general characteristics:
c the operating temperature can be
controlled between 20°C and 50°C.
c exterior and interior air circuits IP-54.
The interior air circuit fan runs permanently
to avoid hot spots in the installation.
c electronic microprocessor control allows:
- operating temperature control.
- management of the door contact.
c control over the following parameters:
- minimum duration of compressor
operation.
- minimum duration of compressor rest time.
- compressor connection at a temperature
of +1°C more than preset.
- compressor disconnection at a temperature
of -5°C less than preset.
- types of alarms: bell and dry contact.
- manual alarm reset.
operating conditions:
c operating temperature: between 20°C and
55°C.
c optional filter required in the case of
installations in difficult environments.
c the coding unit has two handles to
aid transport.
c do not obstruct the air inlets or outlets.
c the apparatus must be installed more than
30 cm from the nearest wall and 10 cm from
the floor.
* Data at 50 Hz
122 HIMEL
electronically controlled CLLMP
cooling units
CLTMP
references for side panel mounting references for top cover mounting
CLLMP 1100 CLLMP 1400 CLLMP 1400T CLLMP 1800T CLTMP 1400 CLTMP 1800T
external dimensions height × width × depth 1030 × 400 × 235 1030 × 400 × 235 1030 × 400 × 235 1030 × 400 × 235 410 × 752 × 412 410 × 752 × 412
refrigerating power DIN 3168 A 35 - A 35 1100 W 1400 W 1400 W 1800 W 1400 W 1800 W
refrigerating power DIN 3168 A 35 - A 50 900 W 1120 W 1120 W 1440 W 1120 W 1440 W
air flow in internal circuit 340 m3/h 450 m3/h 450 m3/h 450 m3/h 320 m3/h 400 m3/h
air flow in external circuit 240 m3/h 320 m3/h 320 m3/h 400 m3/h 450 m3/h 450 m3/h
weight of apparatus 47 kg 48 kg 49 kg 51 kg 48 kg 51 kg
temperature control range 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC 20 - 55oC
operating regulation range 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC 20 - 50oC
supply voltage 230V - 50/60 Hz 230V - 50/60 Hz 3 × 400V - 50/60 Hz 3 × 400V - 50/60 Hz 230V - 50/60 Hz 3 × 400V - 50/60 Hz
nominal/starting current 14,8 / 3,5 A 19,7 / 4,5 A 12 / 1,8 A 12 / 2 A 19 / 4,5 A 12 / 2 A
electrical power consumption A 35 - A 35 700 W 800 W 700 W 900 W 800 W 1000 W
electrical power consumption A 35 - A 50 900 W 1000 W 900 W 1100 W 900 W 1100 W
external IP - internal IP IP-54 /IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 / IP-34 IP-54 /IP-34 IP-54 / IP-34
recommended electrical protection (PIA) 6A 6A 4A 4A 6A 4A
filter unit
For installation in the external climate
control circuit. Reference: CLLMP...
Reference: CFCLL
replacement filter:
Reference: FCLL
CFCLL FCLL
to it.
HIMEL 123
air-water exchangers ICT - ICL
general characteristics
c main components: control system,
exchange cassette, fan for interior circuit in
enclosure, security device against possible
water leaks.
c the desired interior temperature can be
controlled from +25°C to +50°C.
c air/water exchangers have a detection
device which closes a contact on detecting a
water circuit leak. This device can be used
to: power an indicator light, alarm or the
input to a PLC which automatically cuts off
the water supply.
c the interior circuit (which moves the air in
the enclosure) runs constantly to prevent hot
spots in the electrical installation and
components.
c it includes a device to discharge water
collected from condensation to the exterior
as standard.
conditions of use:
c air/water exchangers can be used in all
cases regardless of whether the exterior
temperature is higher or lower than that
required inside the enclosure.
c the enclosure must be sealed to prevent
penetration by exterior air.
dimensions mounting
refrigeration electrical weight
reference depth width height power voltage power (Kg)
(A) (B) (C) (W/oC) (W) roof side
124 HIMEL
air-air heat exchangers ICT - ICL
replacement filters
characteristics reference
HIMEL 125
resistance haters RC
general characteristics
c extruded aluminium body.
c surface temperature limited to 60°C in
ambient temperature conditions -5°C.
c 500 mm power cable with silicone
insulation (except RCV-400, R-55, 90
and 150 models which have connection
terminals-blocks).
conditions of use
c the use of a temperature controller
together with heating resistors is advisable
(thermostats TS 140, TS 141 or hygrostat
HS 300).
c the enclosure must be sealed to prevent
penetration by exterior air.
c electrical protection devices must be fitted
between the power source and the
resistance heaters.
Psis = k × S (Td min − Te min) − Pd Select one or more resistors with a total
power rating higher than the calculated
if the electrical panel is used continuously. value.
126 HIMEL
control devices TS
thermostat TS 140
The contacts of this thermostat are normally
closed (NC), such that the power supply to
a heater is disconnected when the
temperature exceeds the displayed preset
value. load
Charge
2
This device is particularly recommended
υ
V
to avoid a sudden increase in the internal
temperature of the panel during warm
periods so as to enable the useful life of 1
the heater to be extended.
L N
c DIN rail mounting.
1 = connexion d’une résistance
c IP-30. 2
Load = Resistor
c V0 self-extinguishing thermoplastic
material conforms to UL-94.
c temperature adjustable from 0 to 60°C.
c connection: 2 x 2,5 mm2 terminals.
TS 140 60 × 33 × 35 6A to 250 V 40
thermostat TS 141
The contacts of this thermostat are normally
open (N0) making it suitable for use with a
fan such that the power supply to the fan is
connected when the temperature exceeds
the displayed preset value. load
Charge
This device permits control over the interior 2
TS 141 60 × 33 × 35 2A to 250 V 40
thermostat TS 170
This thermostat has switched contacts
making it suitable for use controlling a fan
or heater when the temperature exceeds the
displayed preset value.
2
This device allows the interior temperature load
HIMEL 127
control devices TS
hygrostat HS 300
This device only measures the humidity
inside the enclosure. Used to control the
functioning of a heater when the humidity
exceeds the preset displayed value.
3
c DIN rail mounting. load 11
Charge
c IP-30. 1
c V0 self-extinguishing thermoplastic V
128 HIMEL
thermal control products
HIMEL 129
certificates and official type approval
Both national bodies such as the Laboratorio Det Norske Veritas, etc., have certified the for the electrical industry. This, in turn, has
Oficial J.M. Madariaga, Laboratori General quality of our products after subjecting them allowed us to meet our main objective, which
d´Assaigs i Investigacions and prestigious to rigorous tests. is to offer the national and international
international bodies such as Bureau Veritas, market a wide range of reliable and up-to-
C.S.A. (Canadian Standards Association), This has enabled us to export extensively date products able to fulfil the needs of any
I.M.Q. (Istituto Italiano del Marchio di over a period of many years, and has type of application related to our business.
Qualità), Lloyd´s Register, Germanischer bolstered our experience in the design and
Lloyd, U.L. Underwriters Laboratories Inc, manufacture of insulated metal enclosures
degrees of protection
which it is exposed, will determine the choice Sealed metal enclosures CRN c
of the model to be used.
metal enclosures
130 HIMEL
degrees de protection of enclosures used for low voltage
(1000 Va and 1500 V=) electrical equipment
EN-60529 (IP) and EN-50102 (IK)
UNE-20324
IP IP IK
0 Sin protección
Unprotected
0 Unprotected 0 Unprotected
20
0g
7,5 cm
Provides protection Energy of
against solid
Provides
protection from
01 blow 0,150 J.
1 bodies larger than
50 mm (e.g. 1 water droplets
falling vertically
inadvertent contact
(condensation)
with hand)
20
0g
10 cm
Energy of
Provides protection
02 blow 0,200 J.
Provides protection
against solid bodies
2 larger than 12 mm
(e.g, contact with
2 from water falling
at up to 15o from
vertical 20
0g
fingers)
17,5 cm
Energy of
03 blow 0,350 J.
Provides
protection against Provides protection
3 solid bodies larger
than 2,5 mm (e.g.
3 from water falling
at up to 60o from
20
0g
Energy of
04
25 cm
tools, wires, etc.) vertical
blow 0,500 J.
Provides 20
0g
protection against
4 solid bodies larger
than 1 mm (e.g.
4 Provides protection
from water 05
35 cm Energy of
blow 0,700 J.
fine tools or wires, splashed from
etc.) all directions.
50
0g
20 cm Energy of
5
Provides protection
against dust 5 Provides
06 blow 1,00 J.
(without harmful protection from
sediments) water jet from all
directions 50
0g
Energy of
07 40 cm
blow 2,00 J.
Provides protection
6 Provides total
protection from 6 from temporary
submersion, such
dust as waves 1,7
kg
29,5 cm Energy of
08 blow 5,00 J.
7
15 cm mínimo
1m Provides protection 5k
g
from extended
periods of immersion 20 cm
Energy of
09 blow 10,00 J.
...m 5k
g
m Provides
8 protection from 40 cm
Energy of
prolonged effects
of immersión 10 blow 20,00 J.
under pressure
HIMEL 131
classification of electrical enclosures in accordance
with NEMA, UL and CSA standards
■ Type 1: Indoor use. Provides protection from personnel from accidental contact with the
equipment and protection of the equipment against dirt.
■ Type 2: Indoor use. Provides protection for personnel from accidental contact with the
equipment and protection of the equipment against dirt and slight drips and splashing with non-
corrosive liquids.
■ Type 3: Indoor or outdoor use. Provides protection for personnel from accidental contact with
the equipment and protection of the equipment against dirt, rain, slush, snow, dust clouds and
external ice formation.
■ Type 3R: Indoor or outdoor use. Provides protection for personnel from accidental contact
with the equipment and protection of the equipment against dirt, rain, slush, snow, dust clouds
and external ice formation.
■ Type 3S: Indoor or outdoor use. Provides protection for personnel from accidental contact
with the equipment and protection of the equipment against dirt, rain, slush, snow, dust clouds.
The external mechanism must continue to be operable when layers of ice form.
■ Type 4: Indoor or outdoor use. Provides protection for personnel from accidental contact with
the equipment and protection of the equipment against dirt, rain, slush, snow, dust clouds,
splashing and direct jets of water, and is not damaged by external ice formation.
■ Type 4X: Indoor or outdoor use. Provides protection for personnel from accidental contact
with the equipment and protection of the equipment against dirt, rain, slush, snow, dust clouds,
splashing and direct jets of water, corrosion and is not damaged by external ice formation.
■ Type 5: Indoor use. Provides protection for personnel from accidental contact with the
equipment and protection of the equipment against dirt, build-up in the environment of dust, fluff,
fibres, floating particles and drips and splashing with non-corrosive liquids.
■ Type 6: Indoor or outdoor use. Provides protection for personnel from accidental contact with
the equipment and protection of the equipment against dirt, rain, slush, snow, direct jets of
water, temporary immersion to a limited depth, and is not damaged by external ice formation.
■ Type 6P: Indoor or outdoor use. Provides protection for personnel from accidental contact
with the equipment and protection of the equipment against dirt, rain, slush, snow, direct jets of
water, corrosion, temporary immersion to a limited depth, and is not damaged by external ice
formation.
■ Type 12: Indoor use. No knockouts. Provides protection for personnel from accidental contact
with the equipment and protection of the equipment against dirt, build-up in the environment of
dust, fluff, fibres, floating particles and drips and splashing with non-corrosive liquids, slight
splashing or spillage of oil and non-corrosive refrigerants.
■ Type 12K: Indoor use. No knockouts. Provides protection for personnel from accidental
contact with the equipment and protection of the equipment against dirt, build-up in the
environment of dust, fluff, fibres, floating particles and drips and splashing with non-corrosive
liquids, slight splashing or spills of oil and non-corrosive refrigerants.
■ Type 13: Indoor use. Provides protection for personnel from accidental contact with the
equipment and protection of the equipment against dirt, build-up in the environment of dust, fluff,
fibres, floating particles, against spray, splashing or spills of water, oil and non-corrosive
refrigerants.
132 HIMEL
type of enclosure
protection against
1 2 3 3R 3S 4 4X 5 6 6P 12 12K 13
Dirt c c c c c c c c c c c c c
Ice* c
Dust cloud c c c c c c
Corrosive agents c c
*It is not necessary that the external mechanisms function when the enclosure is covered in ice.
**It is necessary that the external mechanisms function when the enclosure is covered in ice.
type of enclosure
1 2 3 3R 3S 4 4X 5 6 6P 12 12K 13
HIMEL 133
reference
index
134 HIMEL
BRF 24/OL 37 CBC/CRN 23 CM/UCC50 26 CMO 1612/40 32
BRF 26 PLA 95 CBCM/PLA 94 CM/UCC50 27 CMO 1612/40 PM 32
BRF 26PLA 87 CC/PN 73 CM/UCC80 26 CMO 166/30 32
BRF 29/OL 37 CDB/PLM 79 CM/UCC80 27 CMO 166/30 KT 32
BRF 31/OL 37 CDP 100 47 CM/UCP50 26 CMO 166/30 PM 32
BRF 33/OL 37 CDP 120 47 CM/UCP80 26 CMO 166/40 32
BRF 38/OL 37 CDP 200 47 CM/UCR50 26 CMO 166/40 KT 32
BRF 42/OL 37 CDP 200 47 CM/UCR50 26 CMO 166/40 PM 32
BRF 5/CRN 22 CDP 60 47 CM/UCR80 26 CMO 168/30 32
BRF8 PLA 95 CDP 80 47 CM/UCR80 26 CMO 168/30 KT 32
BRF 8/CRN 19 CI 1010 106 CM/UIA50 27 CMO 168/30 PM 32
BRF 8/CRN 22 CI 1010 A 106 CM/UIA80 27 CMO 168/40 32
BRF 8PLA 87 CI 117 106 CM/UMA50 27 CMO 168/40 KT 32
BRP 11 PLA 95 CI 117 A 106 CM/UMA80 27 CMO 168/40 PM 32
BRP 11/CRN 19 CI137 106 CM/UMC50 26 CMO 1810/40 PM 32
BRP 11/CRN 22 CI 137 A 106 CM/UMC50 27 CMO 1810/50 32
BRP 12/OL 51 CI1710 106 CM/UMC80 26 CMO 1810/50 PM 32
BRP 15/OL 51 CI 1710 A 106 CM/UMC80 27 CMO 1812/40 32
BRP 16 PLA 95 CI 1710 BI 106 CM/UMR50 27 CMO 1812/40 PM 32
BRP 16/CRN 19 CI 1713 106 CM/UMR80 27 CMO 1812/40 PM 32
BRP 16/CRN 22 CI 1713 A 106 CM/UTC50 27 CMO 1812/50 32
BRP 17/CRN 22 CI 1713 B 106 CM/UTC80 27 CMO 1812/50 PM 32
BRP 18/OL 51 CI 1713 BI 106 CM3030/200 24 CMO 1816/40 32
BRP 20 PLA 95 CI 1713 BIT 106 CM3030/200 26 CMO 1816/40 PM 32
BRP 20/CRN 19 CI 2216 106 CM3040/200 24 CMO 1816/50 32
BRP 20/CRN 22 CI 2216 A 106 CM3040/200 26 CMO 1816/50 PM 32
BRP 20/CRN 800 22 CI 2216 B 106 CM4040/200 24 CMO 186/30 32
BRP 20/CRN 800 19 CI 2216 BI 106 CM4040/200 26 CMO 186/30 KT 32
BRP 21/CRN 19 CI 2216 BIT 106 CM4060/250 24 CMO 186/30 PM 32
BRP 21/OL 51 CI 2722 106 CM4060/250 26 CMO 186/40 32
BRP 25 PLA 95 CI 2722 BI 106 CM5050/250 24 CMO 186/40 KT 32
BRP 25/CRN 800 22 CI 2723 A 106 CM5050/250 26 CMO 186/40 PM 32
BRP 25/CRN 800 19 CI 3125 106 CM6060/200 24 CMO 186/50 KT 32
BRP 27/OL 37 CI 3125 A 106 CM6080/200 26 CMO 186/60 KT 32
BRP 27/OL 51 CI 3125 BI 106 CM6080/300 24 CMO 188/30 32
BRP 27/OL 180 37 CI 3528 106 CM6080/300 26 CMO 188/30 KT 32
BRP 31/OL 51 CI 3528 A 106 CM8060/300 24 CMO 188/30 PM 32
BRP 31/OL 180 37 CI 3528 BI 106 CM8060/300 26 CMO 188/40 32
BRP 36/OL 37 CIE 2322 106 CMO 1010/30 32 CMO 188/40 KT 32
BRP 36/OL 51 CIE 2322 A 106 CMO 1010/30 PM 32 CMO 188/40 PM 32
BRP 36/OL 180 37 CIE 2413 B 106 CMO 1210/30 32 CMO 188/50 32
BRP 40/OL 51 CIP 137 106 CMO 1210/30 PM 32 CMO 188/50 KT 32
BRP 40/OL 180 37 CIP 1710 106 CMO 1212/40 32 CMO 188/50 PM 32
BRP 6/OL 51 CIP 1710 A 106 CMO 1212/40 PM 32 CMO 188/60 32
BRP 7 PLA 95 CIP 1713 106 CMO 128/30 32 CMO 188/60 KT 32
BRP 7/CRN 19 CIP 1713 A 106 CMO 128/30 KT 32 CMO 188/60 PM 32
BRP 9/OL 51 CIP 1713 B 106 CMO 128/30 PM 32 CMO 188/60 PUP 32
BRPC 27/OL 37 CIP 2216 106 CMO 1410/40 32 CMO 2010/40 32
BRPC 27/OL 51 CIP 2216 A 106 CMO 1410/40 PM 32 CMO 2010/40 PM 32
BRPC 27/OL 180 51 CIP 2216 B 106 CMO 1412/40 32 CMO 2010/50 32
BRPC 31/OL 37 CIP 2216 B 106 CMO 1412/40 PM 32 CMO 2010/50 PM 32
BRPC 31/OL 51 CIP 2722 106 CMO 146/30 32 CMO 2012/40 32
BRPC 31/OL 180 51 CIP 2722 B 106 CMO 146/30 KT 32 CMO 2012/40 PM 32
BRPC 36/OL 37 CIP 2723 A 106 CMO 146/30 PM 32 CMO 2012/50 32
BRPC 36/OL 51 CIP 3125 106 CMO 146/40 32 CMO 2012/50 PM 32
BRPC 36/OL 180 51 CIP 3528 106 CMO 146/40 KT 32 CMO 2012/60 32
BRPC 40/OL 37 CIP 3528 A 106 CMO 146/40 PM 32 CMO 2012/60 PM 32
BRPC 40/OL 51 CL-27 70 CMO 148/30 32 CMO 2012/60 PUP 32
BRPC 40/OL 180 51 CL/CRN 23 CMO 148/30 KT 32 CMO 2016/40 32
CACB 3020 107 CL/CSX 23 CMO 148/30 PM 32 CMO 2016/40 PM 32
CACB 4020 107 CL/PN 73 CMO 148/40 32 CMO 2016/50 32
CACB 5020 107 CLL-27 70 CMO 148/40 KT 32 CMO 2016/50 PM 32
CAON 100 47 CLL/CR-CRS-CRN 23 CMO 148/40 PM 32 CMO 2016/60 32
CAON 120 47 CLLMP 1100 122 CMO 1610/30 32 CMO 2016/60 PM 32
CAON 60 47 CLLMP 1400 122 CMO 1610/30 PM 32 CMO 206/30 32
CAON 80 47 CLLMP 1400 T 122 CMO 1610/40 32 CMO 206/30 KT 32
CB 3020 107 CLLMP 1800 T 122 CMO 1610/40 PM 32 CMO 206/30 PM 32
CB 4020 107 CM/ACS50 27 CMO 1612/30 32 CMO 206/40 32
CB 5020 107 CM/ACS80 27 CMO 1612/30 PM 32 CMO 206/40 KT 32
HIMEL 135
reference
index
136 HIMEL
DANX-35/30 104 DLM 66 21 DTH 8 108 FS 20 E 117
DAX-20/15 M 104 DLM 84 19 ECDPC 105 FS 24 117
DAX-25/20 M 104 DLM 84 21 ECDPC 105 FS 260 E 117
DAX-30/25 M 104 DLM 84 P 19 ECDPC 105 FS 35 119
DAX-35/30 M 104 DLM 84 P 21 ECDPC 105 FS 460 117
DB-10/10 M 104 DLM 88 19 ECON 104/1 45 FS 56 117
DB-15/10 M 104 DLM 88 21 ECON 104/1 45 FS 65 117
DB-20/15 M 104 DLP 114 91 ECON 105/1 45 FS 66 E 117
DB-25/20 M 104 DLP 114+DLP114 91 ECON 105/1 45 FSAF 130 63
DB-30/25 M 104 DLP 114+DLP114 P 91 ECON 106/1 45 FSAF 460 63
DB-8/8 M 104 DLP 114+DLP198 91 ECON 106/1 45 FSAF 56 63
DBN-10/10 104 DLP 114P 91 ECON 106/2 45 H 12 108
DBN-15/10 104 DLP 114P+DLP198 P 91 ECON 106/2 45 H3 108
DBN-20/15 104 DLP 114P/133 86 ECON 108/1 45 H5 108
DBN-25/20 104 DLP114P/133+DLP114P/133 86 ECON 108/1 45 H8 108
DBN-30/25 104 DLP114P/133+DLP198P/231 ECON 108/2 45 HM 12 108
DBN-8/8 104 86 ECON 108/2 45 HM 24 108
DBNX-20/15 104 DLP 132 91 ECON 124/1 45 HM 24 C 108
DBNX-25/20 104 DLP 133 91 ECON 124/1 45 HM 36 108
DBNX-30/25 104 DLP 133+DLP 133 91 ECON 125/1 45 HM 36 C 108
DBNX-35/30 104 DLP 152 91 ECON 125/1 45 HMC 108
DBP 79 DLP 152+DLP 152 91 ECON 126/1 45 HS 300 128
DBX-20/15 M 104 DLP 152+DLP 264 91 ECON 126/1 45 ICL 1800 AG 124
DBX-25/20 M 104 DLP 165 91 ECON 126/2 45 ICL 15 AI 125
DBX-30/25 M 104 DLP 165/198 86 ECON 126/2 45 ICL 35 AI 125
DBX-35/30 M 104 DLP 171 91 ECON 128/1 45 ICL 35 AIN 125
DCOL 30 49 DLP 171+DLP 171 91 ECON 128/1 45 ICL 60 AI 125
DCOL 40 49 DLP 171+DLP 297 91 ECON 128/2 45 ICT 1800 AG 124
DCOL 50 49 DLP 198 91 ECON 128/2 45 ICT 50 AI 125
DCOL 60 49 DLP 198 P 91 ECON 45/1 45 JED-812/2 99
DL/PLM 18 77 DLP 198 P/231 86 ECON 46/1 45 JED-85/00 99
DLA-112 77 DLP 199 91 ECON 46/2 45 JED-86/0 99
DLA-112 78 DLP 231 91 ECON 64/1 45 JED-88/1 99
DLA-168 78 DLP 264 91 ECON 65/1 45 KPLM 23
DLA-24 77 DLP 297 91 ECON 66/1 45 KPLM 79
DLA-24 78 DLP 57 91 ECON 66/2 45 LC-7 23
DLA-240 77 DLP 57+DLP 57 91 ECON 68/1 45 LC-8 23
DLA-240 78 DLP 57+DLP 99 91 ECON 68/2 45 LDB 99
DLA-48 77 DLP 57/76 86 ECON 84/1 45 LT-27 70
DLA-48 78 DLP 57/76+DLP 57/76 86 ECON 85/1 45 LT-8 23
DLA-48 P 77 DLP 57/76+DLP 99/132 86 ECON 86/1 45 LT-8 99
DLA-48 P 78 DLP 76 91 ECON 86/2 45 MB-1010 19
DLA-66 77 DLP 76+DLP 132 91 ECON 88/1 45 MB-1010 20
DLA-66 78 DLP 76+DLP 76 91 ECON 88/2 45 MB-1012 19
DLA-84 77 DLP 95 91 F 130 63 MB-1012 20
DLA-84 78 DLP 95+DLP 165 91 F 460 63 MB-106 19
DLA-84 P 78 DLP 95+DLP 95 91 F 56 63 MB-106 20
DLA-88 78 DLP 95/114 86 F 130 117 MB-108 19
DLA-112 19 DLP 95/114+DLP 165/198 86 F 24 117 MB-108 19
DLA-24 19 DLP 95/114+DLP 95/114 86 F 460 117 MB-108 20
DLA-240 19 DLP 99/132 86 F 56 117 MB-108 77
DLA-48 19 DPC - 10/10 105 F 65 117 MB-108 77
DLA-48 P 19 DPC - 12/8 105 FCLIC 121 MB-1210 19
DLA-66 19 DPC - 15/10 105 FCLIC 125 MB-1210 20
DLA-84 19 DPC - 20/15 105 FE 42 59 MB-128 19
DLA-88 19 DPC - 25/20 105 FE 43 59 MB-128 19
DLM 112 19 DPC - 30/22 105 FE 62 59 MB-128 20
DLM 112 21 DPC - 40/30 105 FE 63 59 MB-2520 19
DLM 168 19 DPC - 65 105 FF 130 117 MB-2520 20
DLM 168 21 DPC - 8/8 105 FF 460 117 MB-3025 19
DLM 24 19 DPC - 80 105 FF 56 117 MB-3025 20
DLM 24 21 DPLA 320 90 FPLS 1827 69 MB-3025 77
DLM 240 19 DPLA 420 90 FPLS 2727 69 MB-3025 77
DLM 240 21 DPLM-200 77 FPLS 2736 69 MB-32 19
DLM 48 19 DPLM-250 77 FPLS 2754 69 MB-32 77
DLM 48 21 DPLM-300N 77 FPLS 3636 69 MB-32 77
DLM 48 P 19 DPLM-350 77 FPLS 3654 69 MB-33 19
DLM 48 P 21 DTH 12 108 FS 130 117 MB-33 20
DLM 66 19 DTH 4 108 FS 156 119 MB-34 19
HIMEL 137
reference
index
138 HIMEL
OLAF 188/40 PM 62 OLN 204/60 36 OLNP-186/60 43 OLPU-2212/2 41
OLAF 188/60 PM 62 OLN 206/40 36 OLNP-186/80 43 OLPU-226 41
OLAF 208/50 PM 62 OLN 206/40 KT 36 OLPO-126 40 OLPU-228 41
OLAF 208/60 PM 62 OLN 206/50 36 OLPO-128 40 OLSI-104 41
OLMV 12 40 OLN 206/50 KT 36 OLPO-146 40 OLSI-104 41
OLMV 14 40 OLN 206/60 36 OLPO-148 40 OLSI-105 41
OLMV 16 41 OLN 206/60 KT 36 OLPO-166 41 OLSI-105 41
OLMV 18 41 OLN 206/80 36 OLPO-166 41 OLSI-106 41
OLMV 18/2 P 41 OLN 206/80 KT 36 OLPO-168 41 OLSI-106 41
OLMV 20 41 OLN 208/40 36 OLPO-168 41 OLSI-108 41
OLMV 20/2 P 41 OLN 208/40 KT 36 OLPO-1810 41 OLSI-124 41
OLMV 22 41 OLN 208/50 36 OLPO-1810 41 OLSI-124 41
OLMV 22/2 P 41 OLN 208/50 KT 36 OLPO-1812 41 OLSI-125 41
OLN 126/40 36 OLN 208/60 36 OLPO-1812 41 OLSI-125 41
OLN 126/40 KT 36 OLN 208/60 KT 36 OLPO-186 41 OLSI-126 41
OLN 126/60 36 OLN 208/80 36 OLPO-186 41 OLSI-126 41
OLN 126/60 KT 36 OLN 208/80 KT 36 OLPO-188 41 OLSI-128 41
OLN 126/80 36 OLN-203/50 36 OLPO-188 41 OLSI-35 41
OLN 126/80 KT 36 OLN-203/60 36 OLPO-2010 41 OLSI-36 41
OLN 128/40 36 OLN-203/80 36 OLPO-2010 41 OLSI-38 41
OLN 128/40 KT 36 OLN-204/50 36 OLPO-2012 41 OLSI-45 41
OLN 128/60 36 OLN-204/60 36 OLPO-2012 41 OLSI-46 41
OLN 128/60 KT 36 OLN-1810/40 36 OLPO-203 41 OLSI-64 40
OLN 128/80 36 OLN-1810/40/2 P 36 OLPO-203 41 OLSI-64 41
OLN 128/80 KT 36 OLN-1810/50 36 OLPO-204 41 OLSI-64 41
OLN 146/40 36 OLN-1810/50/2 P 36 OLPO-204 41 OLSI-65 41
OLN 146/40 KT 36 OLN-1810/60 36 OLPO-206 41 OLSI-66 40
OLN 146/60 36 OLN-1810/60/2 P 36 OLPO-206 41 OLSI-66 41
OLN 146/60 KT 36 OLN-1812/50/2 P 36 OLPO-208 41 OLSI-66 41
OLN 146/80 36 OLN-1812/60/2 P 36 OLPO-208 41 OLSI-66 41
OLN 146/80 KT 36 OLN-1812/60/2 P 36 OLPO-2210 41 OLSI-68 40
OLN 148/40 36 OLN-2010/40 38 OLPO-2210 41 OLSI-68 41
OLN 148/40 KT 36 OLN-2010/40 KT 38 OLPO-2212 41 OLSI-68 41
OLN 148/60 36 OLN-2010/40/2 P 38 OLPO-2212 41 OLSI-84 40
OLN 148/60 KT 36 OLN-2010/50 38 OLPO-226 41 OLSI-84 41
OLN 148/80 36 OLN-2010/50 KT 38 OLPO-226 41 OLSI-84 41
OLN 148/80 KT 36 OLN-2010/50/2 P 38 OLPO-228 41 OLSI-85 41
OLN 166/60 36 OLN-2010/60 38 OLPO-228 41 OLSI-85 41
OLN 166/60 KT 36 OLN-2010/60 KT 38 OLPP-126 40 OLSI-86 40
OLN 166/80 36 OLN-2010/60/2 P 38 OLPP-128 40 OLSI-86 41
OLN 166/80 KT 36 OLN-2010/80 38 OLPP-146 40 OLSI-86 41
OLN 168/60 36 OLN-2010/80 KT 38 OLPP-148 40 OLSI-86 41
OLN 168/60 KT 36 OLN-2010/80/2 P 38 OLPU-126 40 OLSI-88 40
OLN 168/80 36 OLN-2012/40/2 P 38 OLPU-126 KT 40 OLSI-88 41
OLN 168/80 KT 36 OLN-2012/50/2 P 38 OLPU-128 40 P1T-27 E 72
OLN 1810/40 36 OLN-2012/60/2 P 38 OLPU-128 KT 40 PF/PLM 78
OLN 1810/40 KT 36 OLN-2012/80/2 P 38 OLPU-146 40 PF/PLM-32 78
OLN 1810/50 36 OLN-208/80 KT 38 OLPU-146 KT 40 PFI/PLM 78
OLN 1810/50 KT 36 OLN-2210/60 38 OLPU-148 40 PIL 166 37
OLN 1810/60 36 OLN-2210/60 KT 38 OLPU-148 KT 40 PIL 166 46
OLN 1810/60 KT 36 OLN-2210/80 38 OLPU-166 41 PIL 168 37
OLN 186/40 36 OLN-2210/80 KT 38 OLPU-168 41 PIL 168 46
OLN 186/40 KT 36 OLN-2210/80/2 P 38 OLPU-1810 41 PIL 1810 37
OLN 186/50 36 OLN-2212/60/2 P 38 OLPU-1810/2 41 PIL 1810 46
OLN 186/50 KT 36 OLN-2212/80/2 P 38 OLPU-1812 41 PIL 1810 46
OLN 186/60 36 OLN-226/60 38 OLPU-1812/2 41 PIL 186 37
OLN 186/60 KT 36 OLN-226/60 KT 38 OLPU-186 41 PIL 186 46
OLN 186/80 36 OLN-226/80 38 OLPU-188 41 PIL 188 37
OLN 186/80 KT 36 OLN-226/80 KT 38 OLPU-2010 41 PIL 188 46
OLN 188/40 36 OLN-228/60 38 OLPU-2010/2 41 PIL 2010 46
OLN 188/40 KT 36 OLN-228/60 KT 38 OLPU-2012 41 PIL 206 37
OLN 188/50 36 OLN-228/80 38 OLPU-2012/2 41 PIL 206 46
OLN 188/50 KT 36 OLN-228/80 KT 38 OLPU-203 41 PIL 208 37
OLN 188/60 36 OLNM-206/60 42 OLPU-204 41 PIL 208 46
OLN 188/60 KT 36 OLNM-206/80 42 OLPU-206 41 PIL 2210 46
OLN 203/50 36 OLNM-208/60 42 OLPU-208 41 PIN 106 19
OLN 203/60 36 OLNM-208/80 42 OLPU-2210 41 PIN 106 22
OLN 203/80 36 OLNP-166/60 43 OLPU-2210/2 41 PIN 108 19
OLN 204/50 36 OLNP-166/80 43 OLPU-2212 41 PIN 108 22
HIMEL 139
reference
index
140 HIMEL
PLA 15124 T 84 PLA 5104 TR 84 PLA 7103 85 PLA 773 R 84
PLA 15124 T 85 PLA 5104 TR 85 PLA 7103 KT 84 PLA 773 R 85
PLA 15124 TKT 85 PLA 5123 84 PLA 7103 KT 85 PLA 773 T 84
PLA 15124 TR 84 PLA 5123 85 PLA 7103 R 84 PLA 773 T 85
PLA 15124 TR 85 PLA 5123 KT 84 PLA 7103 R 85 PLA 773 TKT 85
PLA 1553 84 PLA 5123 KT 85 PLA 7103 T 84 PLA 773 TR 84
PLA 1553 85 PLA 5123 R 84 PLA 7103 T 85 PLA 773 TR 85
PLA 1553 KT 84 PLA 5123 R 85 PLA 7103 TKT 85 PLA 774 84
PLA 1553 KT 85 PLA 5123 T 84 PLA 7103 TR 84 PLA 774 85
PLA 1553 R 84 PLA 5123 T 85 PLA 7103 TR 85 PLA 774 KT 84
PLA 1553 R 85 PLA 5123 TKT 85 PLA 7104 84 PLA 774 KT 85
PLA 1553 T 84 PLA 5123 TR 84 PLA 7104 85 PLA 774 R 84
PLA 1553 T 85 PLA 5123 TR 85 PLA 7104 KT 84 PLA 774 R 85
PLA 1553 TKT 85 PLA 5124 84 PLA 7104 KT 85 PLA 774 T 84
PLA 1553 TR 84 PLA 5124 85 PLA 7104 R 84 PLA 774 T 85
PLA 1553 TR 85 PLA 5124 KT 84 PLA 7104 R 85 PLA 774 TKT 85
PLA 1554 84 PLA 5124 KT 85 PLA 7104 T 84 PLA 774 TR 84
PLA 1554 85 PLA 5124 R 84 PLA 7104 T 85 PLA 774 TR 85
PLA 1554 KT 84 PLA 5124 R 85 PLA 7104 TKT 85 PLD-812/2 97
PLA 1554 KT 85 PLA 5124 T 84 PLA 7104 TR 84 PLD-812/2 98
PLA 1554 R 84 PLA 5124 T 85 PLA 7104 TR 85 PLD-812/2 99
PLA 1554 R 85 PLA 5124 TKT 85 PLA 7123 84 PLD-812/2 C 97
PLA 1554 T 84 PLA 5124 TR 84 PLA 7123 85 PLD-85/00 97
PLA 1554 T 85 PLA 5124 TR 85 PLA 7123 KT 84 PLD-85/00 98
PLA 1554 TKT 85 PLA 553 84 PLA 7123 KT 85 PLD-85/00 99
PLA 1554 TR 84 PLA 553 85 PLA 7123 R 84 PLD-86/0 97
PLA 1554 TR 85 PLA 553 KT 84 PLA 7123 R 85 PLD-86/0 98
PLA 1573 84 PLA 553 KT 85 PLA 7123 T 84 PLD-86/0 99
PLA 1573 85 PLA 553 R 84 PLA 7123 T 85 PLD-88/1 97
PLA 1573 KT 84 PLA 553 R 85 PLA 7123 TKT 85 PLD-88/1 98
PLA 1573 KT 85 PLA 553 T 84 PLA 7123 TR 84 PLD-88/1 99
PLA 1573 R 84 PLA 553 T 85 PLA 7123 TR 85 PLM-108 77
PLA 1573 R 85 PLA 553 TKT 85 PLA 7124 84 PLM-108/KT 77
PLA 1573 T 84 PLA 553 TR 84 PLA 7124 85 PLM-3025 77
PLA 1573 T 85 PLA 553 TR 85 PLA 7124 KT 84 PLM-3025/KT 77
PLA 1573 TKT 85 PLA 554 84 PLA 7124 KT 85 PLM-32 77
PLA 1573 TR 84 PLA 554 85 PLA 7124 R 84 PLM-32/KT 77
PLA 1573 TR 85 PLA 554 KT 84 PLA 7124 R 85 PLM-43 77
PLA 1574 84 PLA 554 KT 85 PLA 7124 T 84 PLM-43/CME 77
PLA 1574 85 PLA 554 R 84 PLA 7124 T 85 PLM-43/KT 77
PLA 1574 KT 84 PLA 554 R 85 PLA 7124 TKT 85 PLM-43/KT/CME 77
PLA 1574 KT 85 PLA 554 T 84 PLA 7124 TR 84 PLM-54 77
PLA 1574 R 84 PLA 554 T 85 PLA 7124 TR 85 PLM-54/CME 77
PLA 1574 R 85 PLA 554 TKT 85 PLA 753 84 PLM-54/KT 77
PLA 1574 T 84 PLA 554 TR 84 PLA 753 85 PLM-54/KT/CME 77
PLA 1574 T 85 PLA 554 TR 85 PLA 753 KT 84 PLM-64 77
PLA 1574 TKT 85 PLA 573 84 PLA 753 KT 85 PLM-64/CME 77
PLA 1574 TR 84 PLA 573 85 PLA 753 R 84 PLM-64/KT 77
PLA 1574 TR 85 PLA 573 KT 84 PLA 753 R 85 PLM-64/KT/CME 77
PLA 5103 84 PLA 573 KT 85 PLA 753 T 84 PLM-75 77
PLA 5103 85 PLA 573 R 84 PLA 753 T 85 PLM-75/CME 77
PLA 5103 KT 84 PLA 573 R 85 PLA 753 TKT 85 PLM-75/KT 77
PLA 5103 KT 85 PLA 573 T 84 PLA 753 TR 84 PLM-75/KT/CME 77
PLA 5103 R 84 PLA 573 T 85 PLA 753 TR 85 PLM-86 77
PLA 5103 R 85 PLA 573 TKT 85 PLA 754 84 PLM-86/CME 77
PLA 5103 T 84 PLA 573 TR 84 PLA 754 85 PLM-86/KT 77
PLA 5103 T 85 PLA 573 TR 85 PLA 754 KT 84 PLM-86/KT/CME 77
PLA 5103 TKT 85 PLA 574 84 PLA 754 KT 85 PLROL206 38
PLA 5103 TR 84 PLA 574 85 PLA 754 R 84 PLROL208 38
PLA 5103 TR 85 PLA 574 KT 84 PLA 754 R 85 PLROL226 38
PLA 5104 84 PLA 574 KT 85 PLA 754 T 84 PLROL228 38
PLA 5104 85 PLA 574 R 84 PLA 754 T 85 PLS 1827 69
PLA 5104 KT 84 PLA 574 R 85 PLA 754 TKT 85 PLS 2727 69
PLA 5104 KT 85 PLA 574 T 84 PLA 754 TR 84 PLS 2727 A 69
PLA 5104 R 84 PLA 574 T 85 PLA 754 TR 85 PLS 2736 69
PLA 5104 R 85 PLA 574 TKT 85 PLA 773 84 PLS 2736 A 69
PLA 5104 T 84 PLA 574 TR 84 PLA 773 85 PLS 2754 69
PLA 5104 T 85 PLA 574 TR 85 PLA 773 KT 84 PLS 2754 A 69
PLA 5104 TKT 85 PLA 7103 84 PLA 773 KT 85 PLS 3636 69
HIMEL 141
reference
index
142 HIMEL
PMR 1512 86 PN-55/2 ML 72 S27 DL/48 70 TEC7/ML 23
PMR 155+PMR 155 86 PN-55/3 ML 72 SDCR 200 19 TEC7/PLD 79
PMR 155+PMR 157 86 PN-55/4 ML 72 SDCR 250 19 TEC8/ML 23
PMR 157 86 PN-55/A 72 SDCR 300 19 TEC8/PLD 79
PMR 22100 47 PN-55/ML 72 SDCR 400 19 TEDB/ML 23
PMR 22120 47 PN-57 72 SFP-300 77 TEDB/PLD 79
PMR 2260 47 PN-57/2 ML 72 SFP-300 79 TEL FAC/PL 79
PMR 2280 47 PN-57/3 ML 72 SFP-400 77 TEL JIS/PL 79
PMR 42100 58 PN-57/A 72 SFP-400 79 TEL/ML 23
PMR 42120 58 PPA-27 70 SFP-500 77 TEL/PL 79
PMR 4280 58 PPION-126 36 SFP-500 79 TEM/PL 79
PMR 45100 47 PPION-126 44 SFP-600 77 TEM/PLD 53
PMR 45120 47 PPION-128 36 SFP-600 79 TEM/PLD 79
PMR 4560 47 PPION-128 44 SFP-800 77 TER/ML 23
PMR 4580 47 PPION-146 36 SFP-800 79 TER/PL 79
PMR 510 86 PPION-146 44 SIMPA 3 43 TET7/ML 23
PMR 55 86 PPION-148 36 SIMPA 4 43 TET7/PL 79
PMR 55+PMB 55 86 PPION-148 44 ST/PN 73 TET8/ML 23
PMR 55+PMB 57 86 PPION-166 36 STD/CSX 23 TET8/PL 79
PMR 60100 47 PPION-166 44 TA 20 59 TFAC/OLN 52
PMR 60120 47 PPION-168 36 TA 40 59 TFAC/OLN 94
PMR 6060 47 PPION-168 44 TA 60 59 TFI/OLN 52
PMR 6080 47 PPION-1810 36 TAUSA/OLN 52 THS3000 128
PMR 67100 58 PPION-1810 44 TBENZ/OLN 52 TJ-10030 23
PMR 67120 58 PPION-1812 36 TC6/CRN 23 TJ-10030 CMO 34
PMR 6760 58 PPION-1812 44 TC6/CRN 79 TJ-10040 23
PMR 6780 58 PPION-186 36 TC6/CSX 23 TJ-10040 CMO 34
PMR 710 86 PPION-186 44 TC6/ML 23 TJ-10050 CMO 34
PMR 712 86 PPION-188 36 TC6/OLN 52 TJ-12030 CMO 34
PMR 75+PMR 75 86 PPION-188 44 TC6/OLN 94 TJ-12040 CMO 34
PMR 75+PMR 77 86 PPION-2010 38 TC6/PL 79 TJ-12050 CMO 34
PMR 77 86 PPION-2010 44 TC6H/OLN 52 TJ-12060 CMO 34
PMR 82100 47 PPION-2012 38 TC7/CRN 23 TJ-16040 CMO 34
PMR 82120 47 PPION-2012 44 TC7/CRN 79 TJ-16050 CMO 34
PMR 8260 47 PPION-204 36 TC7/CSX 23 TJ-16060 CMO 34
PMR 8280 47 PPION-204 44 TC7/ML 23 TJ-18050 CMO 34
PMR 67100 47 PPION-206 36 TC7/OLN 52 TJ-18060 CMO 34
PMR 67100 47 PPION-206 44 TC7/OLN 94 TJ-20050 CMO 34
PMR 67120 47 PPION-208 36 TC7/PL 79 TJ-20060 CMO 34
PMR 67120 47 PPION-208 38 TC8/CRN 23 TJ-2015 23
PMR 6760 47 PPION-208 44 TC8/CRN 79 TJ-2020 23
PMR 6760 47 PPION-2210 38 TC8/ML 23 TJ-24050 CMO 34
PMR 6780 47 PPION-2210 44 TC8/OLN 52 TJ-24060 CMO 34
PMR 6780 47 PPION-2212 38 TC8/OLN 94 TJ-3015 23
PMR 105 90 PPION-2212 44 TC8/PL 79 TJ-3020 23
PMR 105+PMBR 105 90 PPION-226 38 TCD-27/4 N 70 TJ-4015 23
PMR 105+PMR 107 90 PPION-226 44 TCD-27/6 N 70 TJ-4020 23
PMR 107 90 PPION-228 38 TCD-27/8 N 70 TJ-4025 23
PMR 125 90 PPION-228 44 TCL/PLD 79 TJ-5015 23
PMR 125+PMR 125 90 PPS-27 70 TCNOMO/OLN 52 TJ-5020 23
PMR 125+PMR 127 90 RC-10 126 TCNOMO/OLN 29 52 TJ-5025 23
PMR 127 90 RC-150 126 TCOR/OLN 52 TJ-6020 23
PMR 155 90 RC-20 126 TDB/PLA 94 TJ-6025 23
PMR 155+PMR 155 90 RC-250 126 TDB/PLD 79 TJ-6030 23
PMR 155+PMR 157 90 RC-400 126 TDB/PLD 99 TJ-6030 CMO 34
PMR 157 90 RC-55 126 TDB10/OLN 52 TJ-6040 23
PMR 55 90 RC-60V 200 126 TDB3/OLN 52 TJ-6040 CMO 34
PMR 55+PMR 55 90 RC-90 126 TDBM/PLA 94 TJ-6050 CMO 34
PMR 57 90 RCV-250 126 TE C6/ML 53 TJ-6060 CMO 34
PMR 57+PMR 57 90 RCV-400 126 TE C7/ML 53 TJ-8020 23
PMR 75 90 RPF15 AI 125 TE C8/ML 53 TJ-8025 23
PMR 75+PMR 75 90 RPF35 AI 125 TE DB/ML 53 TJ-8030 23
PMR 75+PMR 77 90 RPF70 AI 125 TE L/ML 53 TJ-8030 CMO 34
PMR 77 90 RV 156 119 TE R/ML 53 TJ-8040 23
PN-34 72 RV 35 119 TE T7/ML 53 TJ-8040 CMO 34
PN-34/2 ML 72 S27 DL/12 70 TE T8/ML 53 TJ-8050 CMO 34
PN-34/ML 72 S27 DL/24 70 TE/PL 79 TJ-8060 CMO 34
PN-53/ML 72 S27 DL/24-2 70 TEC6/ML 23 TJIS/OLN 52
PN-55 72 S27 DL/36 70 TEC6/PLD 79 TJIS/OLN 94
HIMEL 143
reference
index
144 HIMEL
ZUN 106/200 50 ZUN 166/200 33 ZUN 84/200 37
ZUN 123/100 37 ZUN 166/200 33 ZUN 84/200 50
ZUN 123/100 50 ZUN 166/200 37 ZUN 84/200 50
ZUN 123/200 37 ZUN 166/200 37 ZUN 84/200 50
ZUN 123/200 50 ZUN 166/200 50 ZUN 84/200 62
ZUN 124/100 33 ZUN 166/200 50 ZUN 85/100 33
ZUN 124/100 37 ZUN 63/100 33 ZUN 85/100 33
ZUN 124/100 37 ZUN 63/100 37 ZUN 85/100 37
ZUN 124/100 37 ZUN 63/100 50 ZUN 85/100 37
ZUN 124/100 50 ZUN 63/200 33 ZUN 85/100 50
ZUN 124/100 50 ZUN 63/200 37 ZUN 85/100 50
ZUN 124/100 50 ZUN 63/200 50 ZUN 85/100 62
ZUN 124/200 33 ZUN 64/100 33 ZUN 85/200 33
ZUN 124/200 33 ZUN 64/100 33 ZUN 85/200 33
ZUN 124/200 33 ZUN 64/100 33 ZUN 85/200 37
ZUN 124/200 37 ZUN 64/100 37 ZUN 85/200 37
ZUN 124/200 37 ZUN 64/100 37 ZUN 85/200 50
ZUN 124/200 37 ZUN 64/100 37 ZUN 85/200 50
ZUN 124/200 50 ZUN 64/100 50 ZUN 85/200 62
ZUN 124/200 50 ZUN 64/100 50 ZUN 86/100 33
ZUN 124/200 50 ZUN 64/100 50 ZUN 86/100 33
ZUN 125/100 33 ZUN 64/200 33 ZUN 86/100 37
ZUN 125/100 33 ZUN 64/200 33 ZUN 86/100 37
ZUN 125/100 37 ZUN 64/200 33 ZUN 86/100 50
ZUN 125/100 37 ZUN 64/200 37 ZUN 86/100 50
ZUN 125/100 50 ZUN 64/200 37 ZUN 86/100 62
ZUN 125/100 50 ZUN 64/200 37 ZUN 86/200 33
ZUN 125/200 33 ZUN 64/200 50 ZUN 86/200 33
ZUN 125/200 33 ZUN 64/200 50 ZUN 86/200 37
ZUN 125/200 37 ZUN 64/200 50 ZUN 86/200 37
ZUN 125/200 37 ZUN 65/100 33 ZUN 86/200 50
ZUN 125/200 50 ZUN 65/100 33 ZUN 86/200 62
ZUN 125/200 50 ZUN 65/100 37 ZUX 103/100 34
ZUN 126/100 33 ZUN 65/100 37 ZUX 105/100 33
ZUN 126/100 33 ZUN 65/100 50 ZUX 124/100 34
ZUN 126/100 37 ZUN 65/100 50 ZUX 125/100 33
ZUN 126/100 37 ZUN 65/200 33 ZUX 125/100 34
ZUN 126/100 50 ZUN 65/200 33 ZUX 65/100 33
ZUN 126/100 50 ZUN 65/200 37 ZUX 84/100 34
ZUN 126/200 33 ZUN 65/200 37 ZUX 85/100 33
ZUN 126/200 33 ZUN 65/200 50
ZUN 126/200 37 ZUN 65/200 50
ZUN 126/200 37 ZUN 66/100 33
ZUN 126/200 50 ZUN 66/100 37
ZUN 126/200 50 ZUN 66/100 50
ZUN 164/100 33 ZUN 66/200 33
ZUN 164/100 33 ZUN 66/200 37
ZUN 164/100 37 ZUN 66/200 50
ZUN 164/100 37 ZUN 83/100 33
ZUN 164/100 50 ZUN 83/100 37
ZUN 164/100 50 ZUN 83/100 50
ZUN 164/200 33 ZUN 83/200 33
ZUN 164/200 33 ZUN 83/200 37
ZUN 164/200 37 ZUN 83/200 50
ZUN 164/200 37 ZUN 84/100 33
ZUN 164/200 50 ZUN 84/100 33
ZUN 164/200 50 ZUN 84/100 33
ZUN 165/100 33 ZUN 84/100 37
ZUN 165/100 37 ZUN 84/100 37
ZUN 165/100 50 ZUN 84/100 37
ZUN 165/200 33 ZUN 84/100 50
ZUN 165/200 37 ZUN 84/100 50
ZUN 165/200 50 ZUN 84/100 50
ZUN 166/100 33 ZUN 84/100 62
ZUN 166/100 33 ZUN 84/200 33
ZUN 166/100 37 ZUN 84/200 33
ZUN 166/100 37 ZUN 84/200 33
ZUN 166/100 50 ZUN 84/200 37
ZUN 166/100 50 ZUN 84/200 37
HIMEL 145
notes
146 HIMEL
HISPANO MECANO ELECTRICA, S.A.
Export Department Based on the development of the rules and material,
we will not acept any liability for the features
Llobregat, 15 - Pol. Ind. El Pla described in the text and images of this document,
until our services confirm them.
08750 MOLINS DE REI (Barcelona) SPAIN
Tel.: +34 934 843 579
Fax: +34 934 843 489
http://www.himelenclosures.com
900058 K03