Download as pdf or txt
Download as pdf or txt
You are on page 1of 134

SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

03 19.03.2024 APPROVAL RVR PV RK


03 13.03.2024 APPROVAL RVR PV RK REV. REQ
02 31.01.2024 APPROVAL RVR PV RK REV. REQ
01 16.01.2024 APPROVAL RVR PV RK REV. REQ
00 29.12.2023 APPROVAL RVR PV RK REV. REQ
00 20.12.2023 APPROVAL RVR PV RK REV. REQ.
REV. DATE DESC. DRN. BY CHD. BY APPRD. BY LAST STATUS
REVISION HISTORY

DOCUMENT NUMBER 69-PC-36-01

DOCUMENT TITLE DATASHEETS FOR CAAQMS

CUSTOMER: MAHAGENCO

CONTRACTOR: BHARAT HEAVY ELECTRICALS LIMITED

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

CRS (Comments resolution sheet) sheet


AAAQMS Comments ( MAHAGENCO) (Dated: 22.01.2024)
SNO M/s MAHAGENCO POINT M/s SWAN Reply Reference Page No. in AAQMS
Documents
1 CRS (Comments resolution sheet) Confirm, Pointwise Page No : 2
sheet to be included with the replies are attached
revised document
2 For analysers SO2,NO2,CO,O3 and Confirmed and Enclosed Page No : 76-79
NH3-USEPA data-Latest
certification print to be provided
with documents

3 CO2 Analyser-USEPA Certification As per the USEPSA List of Manufacturer declaration


is not available Designated Reference and enclosed for the CO and CO2
Equivalent Methods, TUV analyser working principle and
and MCERTS, the carbon certificate confirmation.
dioxide (CO2) is not and we
hereby inform you that CO2 Page No:88
is not listed for any other
manufacturer.
4 PM2.5,PM10: Met One instruments : Confirmed and Enclosed page No : 89-90
after sales support certificate from
M/s Met One is required to be
submitted
5 BENZENE Analyser: Chromototech: Confirmed and Enclosed Page No :91-92
after sales support certificate from
M/s chromatotech is required to be
submitted.
6 For Benzene analyser-Latest Confirmed and Enclosed Page No : 82-87
MCERT certification to be provided
7 For PM-2.5 and PM-10 analyser the Confirm & compiled, PM2.5 Page No: 17 & 19
provision of 4-20 mA output also and PM-10 analyser
shall be provided Instrument have 0-1 V and
if provision is required we
can add the 4-20 mA
converter to provide the
same.
8 Please indicate software LT Version Confirm & complied, I.e. Page No: 28 & 31
Year duration also windows 13 (Latest ) and
Duration is perpetual.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

9 The UPS shall be 2X100% parallel As per the NIT, 6KVA with Page No : 41 & 42
redundant with 2 sets of battery 1 Hr for Local station and 3
shall be included. KVA with 6 hrs backup UPS
will be provided and
2X100% parallel redundant
with 2 sets of battery is not
required for the CAAQMS
application and we are
giving the assurance of the
UPS and batteries and we
accepted additional 2 years
warranty for the UPS.
10 Please ensure and confirm that Confirm & complied Page No : 33
analyser shelter shall be consider
as per spec clause ref no 3.0 (as per
the NIT)
11 3KVA UPS with 6 Hrs Backup : Incorporated as per the Page No : 42
As per the comments minimum 10 requirement
batteries of 12V/200 AH shall be
considered
12 Minimum 10 No’s of Batteries of Incorporated as per the Page No : 42
12V each shall be considered requirement.
13 Factor of 0.8 shall be conceded Incorporated as per the Page No : 134
instead of 0.7 requirement
14 As per IEEE Std.temperature Incorporated as per the Page No : 134
correction factor also considered in requirement
calculation
15 Earlier 100AH battery considered Incorporated as per the Page No : 134
for 85.68AH, Hence in the present requirement
case sae margin is to be considered
(minimum of 10% margin from
actual)

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

DATASHEETS FOR

1) CAAQMS ANALYZERS AND ASSOCIATED SYSTEMS (SO2, NOx, CO, CO2, O3, NH3, PM2.5,
PM10, BENZENE(BTEX) with all accessories

2) WEATHER SENSORS AND ASSOCIATED SYSTEM

NOTE:

1. Two years’ warranty from the date of installation and commissioning, meeting the contract specification is in
the scopeof M/s Swan Technical Services Pvt Ltd.

2. All consumables and replaceable as required during warranty period will be provided by M/s Swan Technical
Services Pvt Ltd.

3. We M/s swan Technical Services Pvt Ltd confirms that offered CAAQMS system fully meets the
requirement of technical specification of contract and fully comply the CPCB present requirements and
guidelines. In case of any deviation w.r.t. technical specification or non-suitability to process requirement.
We will take full responsibility andcorrective action without any cost implication to customer.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

INDEX
SNO DESCRIPTION
1 SULPHUR DIOXIDE (SO2) ANALYSER FOR CAAQMS
2 NITROGEN (NO-NO2-NOx) ANALYSER FOR CAAQMS
3 CO ANALYSER FOR CAAQMS
4 CO2 ANALYSER FOR CAAQMS
5 OZONE ANALYSER FOR CAAQMS
6 PM 2.5 ANALYSER FOR CAAQMS WITH INLET HEAD OF PM 2.5
7 PM 10 ANALYSER FOR CAAQMS WITH INLET HEAD OF PM 10
8 NH3 ANALYSER FOR CAAQMS
9 BENZENE ANALYSER FOR CAAQMS
10 DILUTION CALIBRATOR (MULTI GAS CALIBRATOR)
11 ZERO AIR GENERATOR
12 SAMPLE HANDLING SYSTEM & ACCESSORIES
13 CENTRAL DATA ACQUITISION SOFTWARE WITH PC & PRINTER
a SOFTWARE FOR CENTRAL SERVER
b CENTRAL SERVER COMPUTER
c CENTRAL SERVER PRINTER
14 LOCAL DATA ACQUITISION SOFTWARE WITH PC & PRINTER
a SOFTWARE FOR LOCAL STATION
b LOCAL STATION COMPUTER
c LOCAL STATION PRINTER
15 ANALYSER SHELTER FOR CAAQMS
16 METEOROLOGICAL MONITORING SYSTEM FOR CAAQMS
a WIND SPEED SENSOR
b WIND DIRECTION SENSOR
c AMBIENT TEMPERATURE SENSOR
d RELATIVE HUMIDITY SENSOR
e SOLAR RADIATION SENSOR
f RAIN GUAGE SENSOR
g METEOROLOGICAL MAST
17 UNINTERRUPTED POWER SUPPLY FOR CAAQMS & DAS
a 6KVA UPS FOR LOCAL STATIONS
b 3KVA UPS FOR CENTRAL SERVER
18 CALIBRATION GAS CYLINDERS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

19 NITROGEN GAS CYLINDERS


20 AIR CONDITIONERS
21 ELECTRONIC DISPLAY BOARD FOR CAAQMS
22 WIRELESS RF COMMUNICATION SYSTEM
23 BILL OF MATERIAL
24 CONSUMABLES FOR ROUTINE OPERATIONS OF AAQMS
25 TECHNICAL DRAWINGS OF CAAQMS
a Flow Schematic Diagram
b GA of Inside Shelter & Rack Arrangements of Analyzers
c GA of Shelter
d Earth Pit of CAAQMS
e CAAQMS Inter-Communication System
f Electrical Diagram of CAAQMS
g Electrical Diagram of 5KVA UPS
26 CERTIFICATIONS OF INSTRUMENTS
27 CATALOGUES OF INSTRUMENTS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

1. SULPHUR DIOXIDE (SO2) ANALYSER FOR CAAQMS

DESCRIPTION SPECIFICATION
Make Acoem Ecotech,
Model Serinus 50
Measurement Continuous Measurement of SO2 in Ambient Air
Technology Pulsed UV Fluorescent Radiation Technology
Range 0 - 20 ppm (auto ranging)
Concentration units mg/m3, μg/m3, ng/m3, ppm, ppb or ppt
Lower detectable limit < 0.3 ppb or 0.2 % of concentration whichever is greater
Response time 60 seconds to 95 %
Linearity < 1 % of full scale
Accuracy 0.5 ppb or 0.5 % of reading whichever is greater
Zero drift (24 Hours) 24 Hours: < 0.5 ppb
(At Lowest Range) Automatic Zero Compensation Available
Span drift (24 hours) 24 hours: < 0.5 % of reading or
(At Lowest Range) < 0.5 ppb whichever is greater
Sample flow rate 725 cc/min
Operating Temperature range 0 - 50 °C
Operating power 230 VAC, 50 - 60 Hz
Power consumption 255 VA (max at start-up) 180 VA (nominal)
Dimension (W) 429 x (H) 175 x (D) 638 mm
Mounting Rack Mounting
Weight: 18.1 kg
Approvals • US EPA approval (EQSA–0809–188)
• EN approval TÜV (936/21221977/B)
• EN approval MCERTS (MC100168/07)
Communication And Output Ports • #1 RS232 port (supports all protocols*)
Available • #2 RS232 port (supports all protocols* and multidrop)
• USB port (Advanced protocol only)
• Bluetooth (Advanced protocol only)
• TCP/IP network port (optional, supports all protocols*)
• *Avaliable protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or
Advanced

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Communication analog and digital • 3 x analog outputs (current or voltage), 12 bit resolution user definable
I/O port range (between two user specified points)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA Voltage range: 0 - 5 V, 0
- 10 V (voltage offset of 0 V, 0.25 V or 0.5 V)
• 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution
• 8 x logic level digital control inputs
Data logging 8 GB removable USB flash memory drive that scores the internal data
logger, event log, automatic/manual configuration backup,
automatic/manual parameter list save.
• Internal data logger (can log up to 12 of 200+ parameters)
• Logger interval (1 second to 24 hours)
• Storage capacity ~ 10 years (set to 1 minute interval)
Display LCD Type

Cycle Time Continuous Measurement

Power Switch On/Off Switch Available

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

2. NO-NO2-NOx ANALYSER FOR CAAQMS

DESCRIPTION SPECIFICATION
Make Aceom Ecotech
Model Serinus 40
Measurement Continuous Measurement of NO, NO2, NOx in Ambient Air
Technology Chemiluminescence Technology
Range (NO, NO2, NOx) 0 to 20 ppm (auto ranging)

Concentration units mg/m3, μg/m3, ng/m3, ppm, ppb or ppt


Lower detectable limit < 0.4 ppb
Response time 15 seconds to 95 %
Linearity ± 1 % of full scale
Zero drift (24 Hours) 24 hours: < 0.5 ppb
(At Lowest Range) Automatic Zero Compensation Available
Span drift (24 Hours) 24 hours: < 0.5 ppb
(At Lowest Range)
Sample flow rate 600 cc/min (total for 2 channels)
Operating Temperature range 0 - 50 °C
Operating power 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption 265 VA (max at start-up) 190 VA (nominal)
Dimension 429 x 175 x 638 mm
Mounting Rack Mounting
Weight: 21.9 kg
Approvals • US EPA approval (RFNA–0809–186)
• EN approval TÜV (936/21221977/A)
• EN approval MCERTS (MC100167/06)

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Communication And Output Ports • #1 RS232 port (supports all protocols*)


Available • #2 RS232 port (supports all protocols* and multidrop)
• USB port (Advanced protocol only)
• Bluetooth (Advanced protocol only)
• TCP/IP network port (optional, supports all protocols*).

*Avaliable protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or


Advanced
Communication analog and digital I/O • 3 x analog outputs (current or voltage), 12 bit resolution user
port definable range (between two user specified points)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V)
• 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution
• 8 x logic level digital control inputs
• 8 x open collector digital status outputs.
Data logging 8 GB removable USB flash memory drive that stores the internal
data logger, event log, automatic/manual configuration backup and
automatic/manual parameter
list save.
• Internal data logger (can log up to 12 of 200+ parameters)
• Logger interval (1 second to 24 hours)
• Storage capacity ~ 10 years (set to 1 minute interval).
Display LCD Type

Cycle Time Continuous Measurement


Controller Micro-Processor based Controller
Power Switch On/Off Switch Available

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

3. CO ANALYSER FOR CAAQMS

DESCRIPTION SPECIFICATION
Make Aceom Ecotech
Model Serinus 30
Measurement Continuous Measurement of CO in Ambient Air
Technology NDIR gas filter correlation technology
Range 0 to 200 ppm (auto ranging)

Concentration units mg/m3, μg/m3, ng/m3, ppm, ppb or ppt


Lower detectable limit < 0.04 ppm or 0.2 % of reading whichever is greater
Response time 60 seconds to 95 %
Linearity < 1 % of full scale
Accuracy 0.1 ppm or 0.1 % of reading whichever is greater
Zero drift (24 Hours) 24 hours: < 0.1 ppm
(At Lowest Range) Automatic Zero Compensation Available
Span drift (24 hours) 7 days: < 0.5 % of reading or 0.1 ppm whichever is greater
(At Lowest Range)
Sample flow rate 1000 cc/min
Operating Temperature range 0 - 50 °C
Operating power 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption 260 VA (max at start-up) 150 VA (nominal)
Dimension 429 x 175 x 638 mm
Mounting Rack Mounting
Weight: 17.8 kg
Approvals • US EPA approval (RFCA–0509–174)
• EN approval TÜV (936/21221977/D)
• EN approval MCERTS (MC100166/06)

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Communication And Output Ports • #1 RS232 port (supports all protocols*)


Available • #2 RS232 port (supports all protocols* and multidrop)
• USB port (Advanced protocol only)
• Bluetooth (Advanced protocol only)
• TCP/IP network port (optional, supports all protocols*).
*Avaliable protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800
orAdvanced
Communication analog and digital I/O • 3 x analog outputs (current or voltage), 12 bit resolution
port userdefinable range (between two user specified points)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V)
• 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution
• 8 x logic level digital control inputs
• 8 x open collector digital status outputs.
Data logging 8 GB removable USB flash memory drive that stores the internal
data logger, event log, automatic/manual configuration backup
andautomatic/manual parameter
list save.
• Internal data logger (can log up to 12 of 200+ parameters)
• Logger interval (1 second to 24 hours)
• Storage capacity ~ 10 years (set to 1 minute interval).
OPTIONS
Display LCD Type

Cycle Time Continuous Measurement

Controller Micro-Processor based Controller

Power Switch On/Off Switch Available

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

4. CO2 ANALYSER FOR CAAQMS

DESCRIPTION SPECIFICATION
Make Aceom Ecotech
Model Serinus 31
Measurement Continuous Measurement of CO2 in Ambient Air
Technology NDIR gas filter correlation technology
Range 0 to 3000 ppm (auto ranging)
Concentration units mg/m3, μg/m3, ng/m3, ppm, ppb or ppt
Lower detectable limit 0.5 PPM
Response time 60 seconds to 95 %
Linearity < 1 % of full scale
Accuracy 0.1 ppm or 0.1 % of reading whichever is greater
Zero drift (24 Hours) 24 hours: < 0.1 ppm for lowest range
(At Lowest Range)
Span drift (24 hours) 7 days: < 0.5 % of reading or 1 ppm whichever is greater
(At Lowest Range)
Sample flow rate 1000 cc/min
Operating Temperature range 0 - 50 °C
Operating power 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption 260 VA (max at start-up) 150 VA (nominal)
Dimension 429 x 175 x 638 mm
Mounting Rack Mounting
Weight: 21.3 kg
Communication And Output Ports • #1 RS232 port (supports all protocols*)
Available • #2 RS232 port (supports all protocols* and multidrop)
• USB port (Advanced protocol only)
• Bluetooth (Advanced protocol only)
• TCP/IP network port (optional, supports all protocols*).
*Avaliable protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or
Advanced
Communication analog and digital I/O • 3 x analog outputs (current or voltage), 12 bit resolution user
port definable range (between two user specified points)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V)
• 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Data logging 8 GB removable USB flash memory drive that stores the internal
data logger, event log, automatic/manual configuration backup and
automatic/manual parameter
list save.
• Internal data logger (can log up to 12 of 200+ parameters)
• Logger interval (1 second to 24 hours)
• Storage capacity ~ 10 years (set to 1 minute interval).
OPTIONS
Display LCD Type

Cycle Time Continuous Measurement

Controller Micro-Processor based Controller

Power Switch On/Off Switch Available

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

5. OZONE ANALYSER FOR CAAQMS

DESCRIPTION SPECIFICATION
Make Aceom Ecotech
Model Serinus 10
Measurement Continuous Measurement of O3 in Ambient Air
Technology Non-dispersive ultraviolet (UV) absorption technology(UV-Photometric)
Range 0 - 20 ppm (auto ranging)

Concentration units mg/m3, μg/ m3, ng/m3, ppm, ppb or ppt


Lower detectable limit < 0.5 ppb
Response time 30 seconds to 95 %
Linearity < 1 % of full scale
Accuracy 0.5 ppb or 0.2 % of reading whichever is greater
Zero drift (24 Hours) 24 hours: < 0.3 ppb
(At Lowest Range)
Span drift (24 hours) 7 days: < 0.5 % of reading
(At Lowest Range) or < 0.3 ppb whichever is greater
Sample flow rate 500 cc/min
Operating Temperature range 0 - 50 °C
Operating power 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption 260 VA (max at start-up)
150 VA (nominal)
Dimension 429 x 175 x 638 mm
Mounting Rack Mounting
Weight: 17.2 kg
Approvals • US EPA approval (EQOA–0809–187)
• EN approval TÜV (936/21221977/C)
• EN approval MCERTS (MC100165/06)

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Communication And Output Ports • #1 RS232 port (supports all protocols*)


Available • #2 RS232 port (supports all protocols* and multidrop)
• USB port (Advanced protocol only)
• Bluetooth (Advanced protocol only)
• TCP/IP network port (optional, supports all protocols*).
*Avaliable protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or
Advanced
Communication analog and digital • 3 x analog outputs (current or voltage), 12 bit resolution user
I/O port definable range (between two user specified points)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V)
• 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution
• 8 x logic level digital control inputs
• 8 x open collector digital status outputs.
Data logging • 8 GB removable USB flash memory drive that stores the internal data
logger, event log, automatic/manual configuration backup and
automatic/manual parameter list save
• Internal data logger (can log up to 12 of 200+ parameters)
• Logger interval (1 second to 24 hours)
• Storage capacity ~ 10 years (set to 1 minute interval).
Display LCD Type

Cycle Time Continuous Measurement

Controller Micro-Processor based Controller

Power Switch On/Off Switch Available

Note:
 M/s SWAN ensures that offered items are fully as per contract specification requirements.
 * Ozone Gas can’t be stored in cylinders, must be generated at site. Therefore, no calibration
cylinder of ozone available in the market. Ozone Analyzers are calibrated through Ozone Gas
Generator, so gas cylinders not required.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

6. PM 2.5 ANALYSER FOR CAAQMS WITH INLET HEAD OF PM 2.5


Particulate Matters (Spirant™ BAM 1100)
Description Technical Specifications
Make Aceom Ecotech
Model Spirant™ BAM 1100
Measurement Continuous Measurement of TSP and PM2.5 in Ambient Air
Principle /Technology Beta attenuation
Accuracy Exceeds US EPA Class III PM2.5 FEM standards for additive and
multiplicative bias
Measurement Resolution 0.1 μg/m3
Display Resolution 1 μg/m3
Detection limit (2σ) 24 hr: < 1.0 μg/m3
Range 1 mg (1000 μg) default setting. Settable from 0.1 mg to 10 mg
Optional ranges Available on request
Measurement cycle time 1 hour average or shorter
Flow rate 16.7 litres/minute adjustable 0 - 20 LPM range actual or standardised flow
Filter tape Continuous glass fiber filter tape, Roll Length Approx. 30m.
Span check Automatic 0.800 mg (typical) span foil, verified hourly
Beta source 14C (carbon - 14), 60 μCi ± 15 μCi (< 2.22 x 106 Beq), half-life 5730 years
Beta detector type Photomultiplier tube with organic plastic scintillator
Operating temperature 0 to + 50 °C
Ambient temperature - 40 to + 55 °C (BX - 596 AT sensor), - 30 to + 50 °C (BX - 592)
(Extended range of sensors available)
Ambient humidity 0 - 90 % RH, noncondensing
Sample humidity Control Active Smart Heater module,10 - 99 % RH setpoint
Power supply 100 - 230 VAC, 50/60 Hz. Factory configured
Power consumption 110 V: 262 W max with Medo pump and inlet heater running(642 W with
Gast pump), 230 V: 312 W max with Medo pump and inlet heater
running(717 W with Gast pump)
Dimensions 310 x 430 x 400 mm
Mounting Rack Mounting
Weight 24.5 kg without external accessories
Communication And Output Ports User interface:
Available
• Menu-driven interface, 8 line 40 character LCD display & keypad
Analog output:
• Isolated 0 - 1 VDC output standard
• 4-20 mA (With external )

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Serial interface: RS232 two-way serial port for PC or modem


communications
Printer output: Output only serial port for data or diagnostic output to a
PC or serial printer
Telemetry inputs: Clock reset (voltage or contact closure), telemeter fault
(contact closure)
Alarm contact closures: Data error, tape fault, flow error, power failure,
maintenance
Error reporting: User-configurable available through serial port, display,
and relay outputs
Memory: 4369 records (182 days at 1 record/hr)
Monitor Includes PM2.5 Sampling
Display LCD Type
Cycle Time Continuous Measurement
Calibration Built In Automatic Calibration System Available.
SHS / Accessories Advanced Smart Heater Technology comes with the analyser which
precisely controls the humidity of the sample.
Controller Micro-processor based Controller
Approvals • US EPA approval (EQPM-0715-266)

Power Switch On/Off Switch Available

Note:
1. M/s SWAN ensures that offered items are fully as per contract specification requirements.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

7. PM 10 ANALYSER FOR CAAQMS WITH INLET HEAD OF PM 10

Particulate Matters (Spirant™ BAM 1000)


Description Technical Specification
Make Aceom Ecotech
Model Spirant™ BAM 1000
Measurement Continuous Measurement of TSP and PM10 in Ambient Air
Principle /Technology Beta attenuation
Accuracy Exceeds US EPA Class III PM2.5 FEM standards for additive and
multiplicative bias
Measurement Resolution 0.1 μg/m3
Display Resolution 1 μg/m3
Detection limit (2σ) 24 hr: < 1.0 μg/m3
Range 1 mg (1000 μg) default setting. Settable from 0.1 mg to 10 mg
Measurement cycle time 1 hour average
Flow rate 16.7 litres/minute adjustable 0 - 20 LPM range actual or standardised
flow
Filter tape Continuous glass fiber filter tape, roll length Approx. 30m.
Span check Automatic 0.800 mg (typical) span foil, verified hourly
Beta source 14C (carbon - 14), 60 μCi ± 15 μCi (< 2.22 x 106 Beq), half-life 5730
years
Beta detector type Photomultiplier tube with organic plastic scintillator
Operating temperature 0 to + 50 °C
Ambient temperature - 40 to + 55 °C (BX - 596 AT sensor), - 30 to + 50 °C (BX - 592)
(Extended range of sensors available)
Ambient humidity 0 - 90 % RH, noncondensing
Sample humidity Control Active Smart Heater module,10 - 99 % RH setpoint
Power supply 100 - 230 VAC, 50/60 Hz.Factory configured
Power consumption 110 V: 262 W max with Medo pump and inlet heater running(642 W
with Gast pump), 230 V: 312 W max with Medo pump and inlet heater
running(717 W with Gast pump)
Dimensions 310 x 430 x 400 mm
Mounting Rack Mounting
Weight 24.5 kg without external accessories
Communication And Output Ports User interface:
Available • Menu-driven interface, 8 line 40 character LCD display & keypad
Analog output:
• Isolated 0 - 1 VDC output standard
• 4-20 mA (With external )

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Serial interface: RS232 two-way serial port for PC or modem


communications
Printer output: Output only serial port for data or diagnostic output to
a PC or serial printer
Telemetry inputs: Clock reset (voltage or contact closure), telemeter
fault (contact closure)
Alarm contact closures: Data error, tape fault, flow error, power
failure, maintenance
Error reporting: User-configurable available through serial port,
display, and relay outputs
Memory: 4369 records (182 days at 1 record/hr)
Monitor Includes PM10
Display LCD Type
Cycle Time Continuous Measurement
Calibration Built In Automatic Calibration System Available.
SHS / Accessories Advanced Smart Heater Technology comes with the analyser which
precisely controls the humidity of the sample.
Controller Micro-processor based Controller
Approvals • US EPA approval (EQPM-0798-122)
Power Switch On/Off Switch Available

Note:
1. M/s Swan ensures that offered items are fully as per contract specification requirements.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

8.NH3 ANALYSER FOR CAAQMS


DESCRIPTION SPECIFICATION
Make Aceom Ecotech
Model Serinus 44
Measurement Continuous Measurement of NH3 in Ambient Air
Technology Chemiluminescence Technology
Range (NH3 ) 0 to 20 ppm (auto ranging)

Concentration units mg/m3, μg/m3, ng/m3, ppm, ppb or ppt


Lower detectable limit < 0.4 ppb
Response time 60 seconds to 95 %
Linearity ± 1 % of full scale
Zero drift (24 Hours) 24 hours: < 0.5 ppb
(At Lowest Range) Automatic Zero Compensation Available
Span drift (24 Hours) 24 hours: < 0.5 ppb
(At Lowest Range)
Operating Temperature range 0 - 50 °C
Operating power 230 VAC, 50 - 60 Hz (auto ranging)
Power consumption 265 VA (max at start-up) 190 VA (nominal)
Dimension 429 x 175 x 638 mm
Mounting Rack Mounting
Weight: 21.85 kg
Approvals • US EPA approval (RFNA-0809-186)

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

9.BENZENE ANALYSER FOR CAAQMS

DESCRIPTION SPECIFICATION
Make Airmotech (Chromatotec)
Model A73022
Measurement Continuous Measurement of Benzene in Ambient Air
Technology GC/PID
Range 0 to 325 μg/m3

Concentration units mg/m3, μg/m3, ppb


Lower detectable limit < 0.01 ppb
Cycle time & Response time 15 min & 60 sec
Operating Temperature range 0 - 50 °C
Operating power 230 VAC, 50 - 60 Hz (auto ranging)
Power consumption 265 VA (max at start-up) 190 VA (nominal)
Mounting Rack Mounting
weight 18 kg
Approvals • MECRT (CSA MC130230/07)

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

10.DILUTION CALIBRATOR (MULTI GAS CALIBRATOR)

DESCRIPTION SPECIFICATIONS
Model AM-5800
Make STSPL
Source Gas Inputs 4 standard 100 - 200 kPa (g) (6 optional)
Dilution Mass Flow Controller 10 SLPM, 0 Deg, 1 ATM (std),
1 SLPM, 2 SLPM, 5 SLPM or 20 SLPM (optional), 2nd MFC (optional)
Flow Accuracy (Constant Temp) Within 1 % of full scale
Flow Repeatability Within 0.2 % of full scale
Linearity Within 0.5 % of full scale
Response Time < 15 seconds
Output Manifold 4 output ports standard
Mounting Rack Mounting
Operating Voltage 230 V VAC 50 / 60 Hz
Power Consumption • 165 VA maximum (typical at start-up) 95 VA after warm-up
Operating Conditions Ambient • 0 - 50°C
Temperature Range
User Interface • Via front panel keypad or computer
Flow Rate • Variable dependent on Dilution Mass Flow Controller installed

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

11. ZERO AIR GENERATOR

DESCRIPTION SPECIFICATION
Make STSPL
Model No SZAG-09
Zero air flow 0 - 500 ml/min
Zero air pressure 6 kg/cm2
Moisture < 0.5 ppm
Purity O2 ~ 20-21% , N2 ~ 79.0 %
Air Scrubbers Air Clean-Up Canister removes:
NOx, NO, NO2, O3, SO2, H2S,
Less < 0.2 ppb
Hydrogen Nil
Power 220 VAC 50 Hz (115 VAC 60 Hz optional)

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

12. SAMPLE HANDLING SYSTEM AND ACCESSORIES

DETAILS OF SHS AND ACCESSORIES


10 Port Sampling Glass Manifold with Heater
Heater Power Supply

PART DESCRIPTION OF SAMPLE Teflon Cap/Inlet


HANDLING SYSTEM SS Flange with SS rod
Sampling FAN with box
Exhaust Manifold

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

13.CENTRAL DATA ACQUITISION SOFTWARE WITH PC & PRINTER

a. SOFTWARE FOR CENTRAL SERVER


CENTRAL STATION SOFTWARE
NAME: Glens
⯃ Glens software is a Windows client-server and cloud application suite for supervisory control,
management and analysis of data from Environmental, Meteorological and Hydrological
monitoring networks.
Glens software allows users to view, analyze, report and distribute environmental quality
dataacross the full range of media.
The Glens software client application runs under Windows either locally or remotely. It provides
comprehensive access to information collected by the communication application and stored in a
Microsoft SQL database Server. Database information is available via standard reports and
displays.
custom reporting software and various third party applications.
Main Software Feature
⯃ Microsoft .NET C# programs for Windows 10 Pro
⯃ SQL Server
⯃ Maintain Historical Data without limitation.
⯃ Multi-threaded communication with data loggers and instruments.
⯃ Internet and intranet networking support.
⯃ Multi-lingual design
⯃ Multi-document interface
⯃ Multi Level Access authorization.
⯃ Multi Users access at the same time.
⯃ Interface entirely menu-driven.
⯃ Alert/Alarm transmission via SMS & email.
⯃ Collects data from remote stations at scheduled times or upon request.
⯃ Dynamic displays.
⯃ GIS dynamic map (ESRI and Google) viewer.
⯃ Automatic data backups
⯃ Data analysis and reporting
⯃ Optional equipment inventory and maintenance system
⯃ Optional custom reports
⯃ Optional Intranet or Internet web site

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Dynamic Displays
⯃ Tabular: Displays current data for one or more stations.
⯃ Multi-Sites Textual & Chart dynamic displays
⯃ Last Received: Date/Time of last data and calibration received from each station.
⯃ Dashboards dynamic displays.
⯃ Dynamic GIS Map Viewer: Data display on GIS layer map or Google map.
Reports and Analysis
By using this feature, the user can produce, print and export textual and graphical reports.
⯃ Station Data Report –Standard tabular and graphical reports for Station values. Day, week,
month and user defined (periodic) report intervals are supported. Stored data values may be
averaged before being reported. Values reported may be filtered.
⯃ Multi-Station – Similar in function to the "Station Data Report,” only designed for more than one
station. Also supports multiple parameters.
⯃ Group - Report that reflects a user defined group of monitors related to one or more stations.
⯃ Histogram - The frequency of occurrence of various ranges of a monitor’s value.
⯃ XY Time Plot – Correlation between two parameters.
⯃ 2Y Time Plot - Two parameters plotted against time.

Note:
1) M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

b. CENTRAL SERVER COMPUTER

DESCRIPTION SPECIFICATION
PROCESSOR INTEL i7
RAM 8 GB
OS Window 13 (latest version)
OS License type & Duration LT Version (Duration: perpetual)
HARD DISK 1 TB SSD OR BETTER
NETWORKING ETHERNET LAN ENABLE
INPUT PORTS USB PORTS
MONITOR 17 INCH
OS WINDOWS 10 OR LATEST
KEYBOARD STANDARD KEYBOARD
MOUSE MOUSE + Mouse pad

Note:
1) M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

c. CENTRAL SERVER PRINTER

DESCRIPTION SPECIFICATION
MAKE HP
MODEL Laser jet P1108 or equivalent
TYPE LASER PRINT
PRINT SIZE A4

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

14.LOCAL STATION DATA ACQUITISION SOFTWARE WITH PC & PRINTER

a. SOFTWARE FOR LOCAL STATION

LOCAL STATION SOFTWARE


NAME: GLens Software
⯃ GLens Software S is an intelligent, multi function, high–performance data acquisition and
reportingsystem. It is designed with affordability and versatility in mind.
⯃ GLens Software is a state-of-the-art system that uses nonproprietary desktop or industrial PC
computercomponents to run flexible, environmental data acquisition software. A wide variety of
data acquisition modules may be installed.
⯃ GLens software features pull-down windows based menus. Only basic knowledge of PC
software operations is required for system operation.
⯃ All hardware components are open stock items available from multiple suppliers.
⯃ As the name implies, GLens Software is designed to help you automate your environmental data
acquisition system projects and make your job easier.
⯃ The system requires an initial setup. Then it starts to run automatically, acquiring
measurements, controlling processes and transferring data to the central computer room.
The system has the capability of detecting errors and autonomously transmitting alarms to
the central. Data values can be filtered and collected according to user-defined criteria.
Local on screen display, printing and alerts transfer by e-mails and text messages (SMS)
supported.

Note:
1) M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

b. LOCAL STATION COMPUTER

DESCRIPTION SPECIFICATION
PROCESSOR INTEL i7
RAM 8 GB
OS Window 13 (latest version)
OS License type & Duration LT Version (Duration: perpetual)
HARD DISK 1 TB SSD OR BETTER
NETWORKING ETHERNET LAN ENABLE
INPUT PORTS USB PORTS
MONITOR 17 INCH
OS WINDOWS 10 OR LATEST
KEYBOARD STANDARD KEYBOARD
MOUSE MOUSE + Mouse pad

Note:
1) M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

c.LOCAL STATION PRINTER

DESCRIPTION SPECIFICATION
MAKE HP
MODEL Laserjet P1108 or equivalent
TYPE LASER PRINT
PRINT SIZE A4

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

15.ANALYSER SHELTER FOR CAAQMS

DESCRIPTION SPECIFICATION
Make STSPL
Accessories As per tender technical specification
External Dimension 3000mm (L) X 3000mm (W) X 2500mm (H)
Inner Sheet Material GI
Outer Sheet Material SS
Thickness of Inner Sheet 1.2 mm
Floor Type Aluminium Chequered Plate
Insulation Thickness 100 mm
Door Entry Dimension 900 mm X 2000 mm
Partition Available for Cylinder storage and UPS Batteries installation
Internal Surface Finish Painted
Electrical wiring As per the CAAQMS requirement.
19” Rack with accessories Included

Note:
1. M/s SWAN ensures that offered items are fully as per contract specification requirements
2. Door dimensions are adequate considering dimension of analyser rack

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

16.METEOROLOGICAL MONITORING SYSTEM FOR CAAQMS

a.WIND SPEED:

DESCRIPTION SPECIFICATIONS
Model Anemometer DWA 8600
Make Dynalab
Wind speed Sensor 3 Cup Anemometer.
Operating Temperature 0-50 deg C
Sensing 3 cup assembly mounted on friction free shaft and coupled to a
chopper.
Starting Threshold 0.3 meters/sec.
Range 0 to 65 meters/sec.
Distance constant 2.5 Meters
Output TTL pulses output proportional to wind speed Built in line driver to drive
long cable > 50 ohms loop resistance.
Accuracy Better than 0.5 m/s up to 10 m/s + 2% FSD
Diameter of cup 50 mm.
Diameter of cup assembly 165 mm.
Construction of sensor body Brass housing and stainless steel shaft
Principle Of Operation: Frequency is proportional to wind speed.
DYNALAB anemometer is a fast response, low threshold opto electronic
anemometer. When rotated by wind, a chopper on the anemometer
shaft interrupts an infra-red light source, generating pulses from a
photo transistor. The signal is amplified and fed through a line driver.
The frequency is proportional to wind speed. The anemometer is
provided with a 3 pin connector for easy replacement and comes with
10 meters of shielded cable.

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

b.WIND DIRECTION:

DESCRIPTION SPECIFICATIONS
Model Wind Vane DWD 8601
Make Dynalab
Wind Direction Sensor Wind Vane.
Sensing Vane coupled to linear endless potentiometer.
Starting threshold Better than 0.3 meters/sec.
Range 0 to 357 degrees (3 degrees electrical gap in the Potentiometer
Output 0 to 5 kilo ohm resistance ( 0 to 357 degrees).
Resolution 1 degree.
Accuracy +/ 3 degrees or better than 2% of the full scale.
Operating Temperature -40 to + 60 degree Celsius
Construction of sensor body Brass housing, stainless steel shaft and aluminium vane
Principle Of Operation: Potentiometric type sensor (Resistance proportional to wind
direction)
DWD 8601 wind vane is a counter balanced, low threshold wind vane.
A Linear, wire wound endless potentiometer is coupled to the vane by
an SS shaft. As the vane turns, it rotates a stainless steel shaft which is
coupled to the potentiometer. This potentiometer has excellent
linearity, very low starting torque.
The north of the wind vane is marked on its body. This line is to be
aligned with actual North with the help of prismatic compass, at the
time of installation. Sensor gives minimum resistance at North (i.e., 0
degree approximately 20 ohms ). The resistance output linearly
proportional to the position of the wind vane

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

c.AIR TEMPERATURE SENSOR:

DESCRIPTION SPECIFICATIONS
Model Air Temperature DWT 8102
Make Dynalab
Sensing Standard Platinum RTD element(PT1000,or PT100 mounted inside a weather
shield
Range - 40 degrees to + 60 degrees Celsius.

Resolution 0.1 degrees Celsius.


Accuracy + 0.2 degrees Celsius.
Output Resistance
Radiation Shield Non Aspirated Radiation Shield
Size of body 320(H) x 90 mm diameter (with weather shield).
Housing Nylon body with weather shield and brass stem to mount the sensor. The
sensor is fitted with a three pin MS connector for easy removal.
Principle Of Operation: RTD (Platinum) Resistance proportional to temperature.
The sensor used for measurement is an RTD (PT 1000). Here the resistance
of the element varies with temperature (increases with temperature),
approximately 3.9 ohms/degree Celsius. The weather shield Is provided to
avoid direct heating of the sensor by sun’s radiation and to protect it from
rain and snow.

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

d. RELATIVE HUMIDITY SENSOR


DESCRIPTION SPECIFICATIONS
Model Relative Humidity DTH 8103
Make Dynalab
Sensing Solid state capacity type sensor.
Sensitivity 0.2% RH
Resolution 0.1 %.
Range 0 to 100 % operating at -40 C to +50 C
Accuracy 3% of full scale reading
Operating Temperature -40 o C to +50 o C.
Power requirement + 5 volts DC.
Power consumption ~ 4 mA.
Output 0- 1V for 0 to 100% humidity
Radiation Shield Non Aspirated Radiation Shield
Size of body 250 (H) x 90 mm diameter. (with weather shield)
Principle Of Operation: Thin film capacitance type sensor.
Humidity sensor features an improved design to provide highly
accurate and rapid measurements. The humidity sensor is a thin film
capacitor element. A dielectric polymer absorbs water molecules from
the air through a thin metal electrode and this causes a capacitance
change proportional to humidity. The response is essentially linear. A
sintered filter is provided to protect the sensor element from dirt,
atmospheric pollutant and water condensation.

A solid state electronic circuit is built in each probe to produce 0 to 1000


M.Volts output signal corresponding to relative humidity value 0 to
100%. The output is single ended.

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

e.SOLAR RADIATION SENSOR

DESCRIPTION SPECIFICATIONS
Model Net Radiometer DWR 8101
Introduction The DYNALAB Net Radiometer measures the difference between the
incoming and outgoing Solar radiation on a horizontal surface.
Spectral response 0.3 to 60 microns.
Range 0-1500 watt/m2
Sensitivity 40 uV/watt/sq.m.
Accuracy + 3.5%
Operating Temperature 0-50 deg C
Sensing element Two blackened surfaces with a thermopile in between
Wind shield Polyethylene domes.
Carrying arm Approx. 1 m long aluminium tube.
Sensor Two thin metallic films blackened with a special paint ( which has about 98 %
absorption in the entire range ) stuck on the top and bottom of a former about
1 cm thick constitute the sensor. A multi element copper constantan
thermocouple precisely measures the difference of temperature between the
top and bottom surfaces. This difference of temperature is a measure of the
net solar radiation.
The blackened surfaces are protected from rain and dust by very thin molded
polyethylene domes which transmit all
Solar radiation in the 0.3 to 60 micron spectral range . A container with a
desiccant is provided to keep the insides of the domes dry.

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

f. RAIN GUAGE SENSOR:


DESCRIPTION SPECIFICATIONS
Model Rainfall Sensor DTR 8104
Make Dynalab
Sensor Type Tipping bucket rain gauge.

Sensing Magnet and reed switch (on-off output).

Resolution 0.5 mm.


Accuracy better than + 5%
Operating Temperature -40 o C to +50 o C. with built in heater(optional)
Rim diameter 203 mm.
Collecting area 325 mm2
Material Rain gauge shell made of FRP. Bucket made of stainless steel and
mounting assembly of powder coated brass. (SS316 body
optional)
Range 0 - Unlimited mm/Hr.
Sensitivity 0.5 mm (rainfall per pulse)
Principle Of Operation It uses a tipping bucket mechanism to produce a contact closure
every time it receives a predetermined quantity of rainfall. The
body and funnel are made of FRP (Fibre glass Reinforced Plastic),
rim is made of gun metal. All parts having contact with water are
made of stainless steel. Each tip of the bucket produces an on-off
output when the magnet passes over the reed switch.
Other features: Rain gauge is self-recording type with recording facility in
electronics. This has automatic function for computing rainfall for
pre-set time periods.

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

g.METEOROLOGICAL MAST

DESCRIPTION SPECIFICATIONS
MAKE STSPL
TYPE TELESCOPIC
EXTENDED HEIGHT 10M
MATERIAL ALUMINIUM
ACCESSORIES Necessary Hanger and Holders along with electrical grounding set
shall be provided for installation of all the sensors.

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

17. UNINTERRUPTED POWER SUPPLY FOR CAAQMS & DAS

a. 6KVA UPS:
DESCRIPTION SPECIFICATIONS
Model GXT MTX+ 6KVA or equivalent
Make VERTIV (Emerson)
CAPACITY 6000 VA
Phase 3 phase in / 1 phase out
INPUT CHARACTERISTIC
Nominal Voltage 230 VAC
Voltage Range 160 VAC-300 VAC ± 3% at 100% Load
Frequency Range 46~54 Hz or 56~64Hz
OUTPUT CHARACTERISTICS
Output Voltage 220/230/240VAC
AC Voltage Regulation ± 1%
(Batt. Mode)
Frequency Range 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
(Synchronized Range)
Harmonic Distortion ≤3 % @ 100% Linear Load : ≤7% @100% Non-Linear Load
BATTERY CHARACTERISTICS
Battery Type SMF
Battery Capacity 12V/42AH
Numbers 16
Charging Current (max.) Max.: 6A ± 10% (settable)
Charging Current Voltage 13.65 V ±1%
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input / Output voltage,
Discharge timer, and Fault conditions
PHYSICAL
Dimension, D X W X H (mm) 369x190x630
Net Weight (kgs) 75
ENVIRONMENT
Operation Humidity <95% and non-condensing
Noise Level Less than 65dBA @ 1 Meter

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements.
COPYRIGHT AND CONFIDENTIAL
THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

b.3 KVA UPS FOR CENTRAL SERVER: AC room controlled temperature is recommended as 25 Deg.C for UPS batteries.

DESCRIPTION SPECIFICATIONS
DESCRIPTION SPECIFICATIONS
Model GXT MTX+ 3KVA or equivalent
Make VERTIV (Emerson)
Phase 1 phase in / 1 phase out
CAPACITY 3000 VA
INPUT CHARACTERISTIC
Nominal Voltage 230 VAC
Voltage Range 160 VAC-300 VAC ± 3% at 100% Load
Frequency Range 46~54 Hz or 56~64Hz
OUTPUT CHARACTERISTICS
Output Voltage 220/230/240VAC
AC Voltage Regulation ± 1%
(Batt. Mode)
Frequency Range 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
(Synchronized Range)
Harmonic Distortion ≤3 % @ 100% Linear Load : ≤7% @100% Non-Linear Load
BATTERY CHARACTERISTICS
Battery Type SMF
Battery Capacity 12V/200AH
Numbers 10
Charging Current (max.) Max.: 6A ± 10% (settable)
Charging Current Voltage 13.65 V ±1%
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input / Output voltage,
Discharge timer, and Fault conditions
PHYSICAL

Dimension, D X W X H (mm) *369x190x630


ENVIRONMENT
Operation Humidity <95% and non-condensing
Noise Level Less than 65dBA @ 1 Meter

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements.
COPYRIGHT AND CONFIDENTIAL
THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

18. CALBRATION GAS CYLINDERS

DESCRIPTION SPECIFICATIONS
Make CHEMTRON SCIENCE
Calibration Gas SO2 ,NO,CO,CO2,NH3,BTEX
Filling Pressure 10L /130Kg/ cm2
Preparation Tolerance PT/ 20, CA/ 3
Cylinder Material Aluminium
Capacity 10Ltr.Water Capacity
Regulator (LH/RH) Size LH For CO Gas & RH For NO, SO2
Stability Period 12 MONTHS
Method of Preparation Gravimetric
Analytical Method IR ANALYSER/ NIST TRACABILITY
Accuracy 3%
Cylinder Basis Outright
Concentration(Range) *SO2 45 ppm Balance N2
*NO 45 PPM Balance N2
*CO 500 ppm Balance N2
*CO2 3050 ppm Balance N2
*NH3 45 PPM Balance N2
*BENZENE-5PPM, M+P XYLENE-5PPM, ETHYL BENZENE-

5PPM, TOLUENE-5PPM, O-XYLENE-5PPM,Balance N2

Note:
1. M/s SWAN ensures that offered items are fully as per contract specification requirements.
2. Selected concentrations are suitable for the span calibration of the corresponding analyzer through Multi
Gas Dilution Calibrator.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

19. N2 GAS CYLINDER

DESCRIPTION SPECIFICATIONS
Make CHEMTRON SCIENCE
Gas N2
Filling Pressure 47L /140Kg/cm2
Preparation Tolerance PT/ 20, CA/ 3
Cylinder Material CS
Capacity 47 Ltr.Water Capacity
Regulator (LH/RH) Size RH
Stability Period 12 MONTHS
Method of Preparation Gravimetric
Analytical Method IR ANALYSER/ NIST TRACABILITY
Accuracy 3%
Cylinder Basis Outright

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

20. AIR CONDITIONERS

DESCRIPTION SPECIFICATIONS
Capacity 1.5 Ton
Energy Star Rating 3 Star
Compressor Inverter Compressor
Cooling Capacity 5100 W or Better
Power Features AC 230 V/50 Hz
Indoor noise level (dB) 29 - 60 db or Better
Power Consumption 1400 W or More Efficient
Gas R 32

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

21. ELECTRONIC DISPLAY BOARD FOR CAAQMS

DESCRIPTION SPECIFICATIONS
TYPE LED DISPLAY
NO. OF LINES MULTI LINES
SIZE 4 FEET(H) x 8 FEET (L)
VISIBILITY 80- 100M DURING DAY TIME
COLOUR MULTI
LANGUAGE ENGLISH

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

22. Wireless RF Communication System

DATASHEETS FOR WIRELESS COMMUNICATION SYSTEM


FOR AAQMS

NOTES:

1. One-year warranty, meeting the contract specification is in the scope of M/s Swan.

2. All consumables and replaceable as required during warranty period will be provided by M/s Swan.

3. M/s. Swan will be responsible for installation, commissioning of the wireless communication system
and M/s Swan will also cover RF survey, system design, frequency liasoning, frequency license &
royalty charges for 1 year from the date of commissioning. M/s BHEL/MAHAGENCO has to provide
necessary documents from respective department for the issuance of license.

INDEX:
. No. Description
Technical Details / Datasheets for AAQMS Wireless System
BOM for AAQMS Wireless System

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

Technical Details / Datasheet:


DESCRIPTION SPECIFICATIONS
TYPE Wireless communication system
Wireless QCA9882 5GHz
802.11ac, 2x RP-SMA
connectors, Dual chain
Extras beeper, signal and status
LEDs, voltage and
temperature sensors
Supported channels 20/40/80MHz
Power options PoE: 8-30V DC on Ether1
(Non 802.3af).
Consumption: 12W at
24V
OS MikroTik RouterOS,
Level4 license
Kit includes Netbox outdoor unit,
PoE injector, mounting
loop, DIN rail mount,
mounting ring
Dimensions 246x135x50mm; Weight:390g
Electrical &other Specifications
Frequency Range 4.7-5.875 GHz
Gain 30 dBi typically
Polarization Dual (Vertical and
Horizontal)
Power Rating 100 watts
Physical/Environmental Specifications
Diameter x Depth 70 x 45cm (27.5 x 17.8in)
Reflector Aluminum
Operating Temperature -50°C to 80°C(-49°F to 158°F)

Note: M/s SWAN ensures that offered items are fully as per contract specification requirements.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA SHEET FORCAAQMS DOC No.: 69-PC-36-01 REVISION: 03

BOM for AAQMS Wireless System:

BILL OF MATERIALS- WIRELESS COMMUNICATION SYSTEM


Central Server
Item Description Make Model Nos Total Quantity Station 1 Station 2 Station 3

RF WIRLES AP WITH ANTINA


MIKRO TIK
Antennas MTAD-5G- Nos 4 1 1 1 1
30D3
MIKRO TIK
RF WIRLES AP RB911G Nos 4 1 1 1 1
Dlink
*outdoor Armored CAT6 Cable CAT6 Mtr 145 15 15 15 100
MIKRO TIK
Accessories ---- Lot 4 1 1 1 1
*6 mtr Self supported Pole ---- ----- Nos 4 1 1 1 1
mast along with supporting
structure, civil foundation,
fabrication etc.

1) Note:
2) All mounting arrangements for Antenna will be in M/s Swan scope.
3) At AAQMS stations Radio modem & SMPS shall be mounted on AAQMS PC desk. No separate cabinet is envisaged. At central station Radio & SMPS shall be mounted
inside IP 65 JB & JB shall be installed as per actual site condition.
4) Required Pole mast at all the stations with civil foundation, earthing shall be in M/s Swan Scope.
5) *Cable quantities & Self-supported Pole mast length mentioned are indicative only and M/s swan will supply all the accessories to complete the RF communication
system.
6) M/s SWAN ensures that offered items are fully as per contract specification requirement.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT
BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA SHEET FORCAAQMS DOC No.: 69-PC-36-01 REVISION: 03

23. BILL OF MATERIALS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE
USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA SHEET FORCAAQMS DOC No.: 69-PC-36-01 REVISION: 03

BILL OF MATERIALS –
MAIN SUPPLY
Central
SL No. Item Description Make Model Total Quantity Station 1 Station 2 Station 3
Server
1 Sulphur Dioxide (SO2) Analyser for CAAQMS ACEOM ECOTECH SERINUS 50 3 1 1 1 0

2 Nitrogen Analyser for CAAQMS ACEOM ECOTECH SERINUS 40 3 1 1 1 0

3 CO Analyser for CAAQMS ACEOM ECOTECH SERINUS 30 3 1 1 1 0

4 CO2 Analyser for CAAQMS ACEOM ECOTECH SERINUS 31 3 1 1 1 0

5 Ozone Analyser for CAAQMS ACEOM ECOTECH SERINUS 10 1 1 0 0 0

6 NH3 Analyser for CAAQMS ACEOM ECOTECH SERINUS 44 3 1 1 1 0


PM 2.5 Analyser for CAAQMS WITH SAMPLE PUMP & INLET HEAD OF ACEOM ECOTECH
7 SPIRANT BAM 1100 3 1 1 1 0
PM 2.5
PM 10 Analyser for CAAQMS WITHSAMPLE PUMP & INLET HEAD OF PM ACEOM ECOTECH
8 SPIRANT BAM 1000 3 1 1 1 0
10
BENZENE Analyser CHROMATOTEC
9 A73022 3 1 1 1 0
(AIRMOTEC)
10 DILUTION CALIBRATOR (MULTI GAS CALIBRATOR) STSPL AM-5800 3 1 1 1 0

11 CENTRAL DATA ACQUITISION SOFTWARE WITH PC & PRINTER DELL 1 0 0 0 1

12 LOCAL STATION DATA ACQUITISION SOFTWARE WITH PC & PRINTER DELL 3 1 1 1 0

13 ZERO AIR GENERATOR STSPL 3 1 1 1 0

14 Analyser Shelter for CAAQMS with All Accessories STSPL 3 1 1 1 0


FURNITURE

CHAIR

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE
USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA SHEET FORCAAQMS DOC No.: 69-PC-36-01 REVISION: 03

CUPBOARD

TABLE
Other Accessories as per NIT
15 ELECTRONIC DISPLAY BOARD FOR CAAQMS AT MAIN GATE STSPL 1 0 0 0 1

METEOROLOGICAL MONITORING SYSTEM FOR CAAQMS


 WIND SPEED DYNALAB
 WIND DIRECTION
 AIR TEMPERATURE SENSOR
 RELATIVE HUMIIDTY SENSOR
 SOLAR RADIATION SENSOR
16  RAIN GUAGE SENSOR 1 1 0 0 0
 METEOROLOGICAL MAST
17 DATA LOGGER FOR WEATHER MONITORINGS STATIONS DYNALAB 1 1 0 0 0

18 UNINTERRUPTED POWER SUPPLY FOR CAAQMS & LOCAL DAS VERTIV (Emerson) 3 1 1 1 0

19 UNINTERRUPTED POWER SUPPLY FOR CENTRAL DAS VERTIV (Emerson) 1 0 0 0 1


GAS SAMPLE HANDELING SYSYTEM WITH GLASS MANIFOLD, HEATERS,
20 STSPL 3 1 1 1 0
EXHAUST FAN & GLASS INLET
21 SO2 GAS CYLINDER CHEMTRON SCIENCE 3 1 1 1 0

22 NO GAS CYLINDER CHEMTRON SCIENCE 3 1 1 1 0

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE
USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA SHEET FORCAAQMS DOC No.: 69-PC-36-01 REVISION: 03

23 CO GAS CYLINDER CHEMTRON SCIENCE 3 1 1 1 0

24 CO2 GAS CYLINDER CHEMTRON SCIENCE 3 1 1 1 0

25 NH3 GAS CYLINDER CHEMTRON SCIENCE 3 1 1 1 0

26 BTEX GAS CYLINDER CHEMTRON SCIENCE 3 1 1 1 0

27 N2 GAS 47 LITRE CYLINDER CHEMTRON SCIENCE 3 1 1 1 0

28 EARTHING SYSTEM AT SITE STSPL 3 1 1 1 0

29 OTHER INSTALLATION ACESSORIES AS PER THE REQUIRMENT STSPL 3 1 1 1 0


30 WIRELESS RF COMMUNICATION SYSTEM WITH ALL ACCESSORIES MIKRO TIK
4 1 1 1 1

31 CONSUMABLES FOR CAAQMS ANALYSERS STSPL 3 1 1 1 0

 Note:

 M/s Swan will bear all the initial cost and bill for one year for telephone connections, M/s Swan will obtain necessary approval for licenses
authorizing the use of wireless communication equipment with specified frequencies.

 M/s Swan will supply the wireless RF communication system as per the site requirement for successful as per contract specification requirements.

 M/s Swan ensures that offered items are fully as per contract specification requirements.

 All the Instruments will be fully calibrated and tested before supply.

 M/s swan ensure that offered O & M contract for one year after commissioning of stations as per tender specifications.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE
USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA SHEET FORCAAQMS DOC No.: 69-PC-36-01 REVISION: 03

24. CONSUMABLES FOR ROUTINE OPERATIONS OF AAQMS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE
USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA SHEET FORCAAQMS DOC No.: 69-PC-36-01 REVISION: 03

CONSUMABLES FOR ROUTINE OPERATION OF EACH AAQMS


Offered Replacement
Part Description
Frequency
Filter Tape Roll, Glass Fiber for PM Analysers 12 2 months
Filter element, 5 micron, consumable (24 per pack) for Gas Analysers 1 15 days

Annual Maintenance Kit, SO2 Analyser 1 1 Year

Annual Maintenance Kit, NOx Analyser 1 1 Year

Annual Maintenance Kit, CO Analyser 1 1 Year

Annual Maintenance Kit, CO2 Analyser 1 1 Year

Annual Maintenance Kit, Ozone Analyser 1 1 Year

Annual Maintenance Kit, NH3 Analyser 1 1 Year

Annual Maintenance Kit, Benzene Analyser 1 1 Year

Molecular Sieve 13X - 1 Kg Refill, Zero Air Generator, 1KG 1 1 Year

Purafil, 0.5kg, Zero Air Generator 1 1 Year


Disposable Filter Unit, Zero Air Generator

Note

 Replacement frequency of consumables also depends upon the local conditions and may change as per atmospheric conditions like dust, humidity etc.

 Any other item not covered above but require for operation of AAQMS would be supplied as part of contract.

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE
USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

25.TECHNICAL DRAWINGS OF CAAQMS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

LIST OF DRAWINGS
S.NO TITLE DRAWING NUMBER
a Flow Schematic Diagram DWG-VA-20231212-SFD
b GA of Inside Shelter && Rack Arrangements DWG-VA-20231212-SHTLINSD
of Analyzers
c GA of Shelter DWG-VA-20231212-SHTLD
d Earth Pit of CAAQMS DWG-VA-20231212-EP
e CAAQMS Inter-Communication System DWG-VA-20231212-ICS
f Electrical Diagram of CAAQMS DWG-VA-20231212-ED
g Electrical Diagram of 6KVA UPS DWG-VA-20231212-UPS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

a) Flow Schematic Diagram

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
Flow Schematic
Meteorological Sensors
PM10 Inlet PM2.5 Inlet
Air Inlet
PM10 Analyser PM2.5 Analyser
Meteorological Data Logger
DATA LOGGER
T I M E / DATA
SO2 Analyser
Pump Pump
VENT
Display Board
Sampling
Manifold NOx Analyser
Pump AMBIENT AIR QUALITY
RSPM 10: 95 µg/M3 RSPM 2.5: 95 µg/M3
SO2: 95 µg/M3 NOx: 95 µg/M3
CO2: 95 µg/M3 CO: 95 µg/M3
Pump
NH3 Analyser O3: 95 µg/M3 NH3: 95 µg/M3
BTEX: 95 µg/M3 TEMP: 38 OC
Local PC
WS: 28 m/sec WD: 285O
Pump
NH3 Converter
Central PC
CO Analyser
Pump
CO2 Analyser
Pump
O3 Analyser
Pump
BTEX Analyser
Multi-Point Calibrator
Zero/Cal Gas Cylinders
AIR IN
SO2 NO NH3 CO CO2 N2 BTEX TITLE:
Flow Schematic
SWAN TECHNICAL SERVICES PVT. LTD., BHARAT HEAVY ELECTRICALS LIMITED., DATE NAME
MADHAPUR, HYDERABAD HARIDWAR DRAWN 14.12.2023 D. J. N. CHARY
CHECKED 16.12.2023 D. J. N. CHARY
MATERIAL: VARIOUS APPROVED
PROJECT NAME:
SCALE: NTS SHEET: 3 OF 4 AMBIENT AIR QUALITY MONITORING STATIONS
ALL DIMENSIONS ARE IN MM
PROJECTION:
CUSTOMER: BHEL, HARIDWAR
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

b) GA of Inside Shelter & Rack Arrangements of Analysers

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
Analyser Placement
A.C Outdoor Unit A.C Outdoor Unit
22
23 1
4 Battery Bank
Maintenance
Tube Light Socket 32A
5 5
Timer
UPS 6 KVA 21
3 12
19" Rack 20
1 32U 800D 13
19
14
Tube Light 26 2
DATA LOGGER
18
15 T IME / DATA
D
A
PLAN 16 17
10
6 7 8
9
5 5
Controlled temperature is 19" x 36U Analyser Racks
recommended as 25 Deg.C
for UPS Batteries.
25
2
DAT A LO GGER
TITLE:
11 Analyser Placement
SWAN TECHNICAL SERVICES PVT. LTD., BHARAT HEAVY ELECTRICALS LIMITED., DATE NAME
3 MADHAPUR, HYDERABAD HARIDWAR 14.12.2023 D. J. N. CHARY
1 DRAWN
CHECKED 16.12.2023 D. J. N. CHARY
24 MATERIAL: VARIOUS APPROVED
PROJECT NAME:
SCALE: NTS SHEET: 2 OF 4 AMBIENT AIR QUALITY MONITORING STATIONS
ELEVATION VIEW - A ALL DIMENSIONS ARE IN MM
PROJECTION:
CUSTOMER: BHEL, HARIDWAR
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

c) GA of Shelter

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
Shelter 10' X 10' X 9'
3000
A.C Outdoor Unit A.C Outdoor Unit
Electrical Wiring - Shelter
50

Lifting Hooks - 4 Nos.


Timer
CONTINUOUS AMBIENT AIR QUALITY MONITORING STATION
Installed & commissioned by
Maintenance AC Unit - 1 AC Unit - 2
Tube Light Socket 32A SWAN TECHNICAL SERVICES PVT. LTD., HYDERABAD
Ventilators - 2 Nos.
Verticle Posts Mains Input
Timer
M.S RHS
4Nos 6A & 2 Nos. 16A Sockets

415 V AC
450 mm height from Floor

Split type A/C UPS


Analyser Rack
2700

2650
UPS Power

Y
Al. Windows - 2 nos.
3000

B
Tube Light 300 X 300 mm
N
G
PC Table
B
Battery Bank
4Nos 6A & 2 Nos. 16A Sockets
450 mm height from Floor

A.C Outdoor Unit


UPS Power

Tube Light Bulk Head Light - 2 Nos.


5 mm thick Grouting Plate Maintenance
3000 Socket
Tube Lights - 3 Nos.
D ELEVATION VIEW - B
A
Rear side

35 mm
PLAN

50 mm
3000 3000

100

100

80 mm
Suatable Stiffners

600

35 mm
1200
AIR QUALITY MONITORING STATION

533
600 40 x 80 Box
600 600 600 600

40
Steel Door
2700

900 x 2100mm
2100

3000

3000
500

534
50 x 100 Box 100
100 ISMB

533
100 75 mm

1200
600 510 600 510 600 6 mm thick Grouting Plate
welded to I-Beam

600

150 mm
3000
2X18 mm dia holes

50 mm
for M 16 J-Bolts
ELEVATION VIEW - A TOP FRAME PLAN BASE FRAME PLAN
Front side
TITLE:
Shelter 10' X 10' X 9'
SWAN TECHNICAL SERVICES PVT. LTD., BHARAT HEAVY ELECTRICALS LIMITED., DATE NAME
MADHAPUR, HYDERABAD HARIDWAR DRAWN 14.12.2023 D. J. N. CHARY
CHECKED 16.12.2023 D. J. N. CHARY
MATERIAL: VARIOUS APPROVED
PROJECT NAME:
SCALE: NTS SHEET: 1 OF 4 AMBIENT AIR QUALITY MONITORING STATIONS
ALL DIMENSIONS ARE IN MM
PROJECTION:
CUSTOMER: BHEL, HARIDWAR
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

d) Earth Pit of CAAQMS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

e) CAAQMS Inter-Communication System

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
3 AAQMS with Central PC Meteorological
Sensors
Meteorological
Sensors
DISPLAY BOARD
AMBIENT AIR QUALITY
RSPM 10: 95 µg/M3 RSPM 2.5: 95 µg/M3
SO2: 95 µg/M3 NOx: 95 µg/M3
CO2: 95 µg/M3 CO: 95 µg/M3
O3: 95 µg/M3 NH3: 95 µg/M3
BTEX: 95 µg/M3 TEMP: 38 OC
WS: 28 m/sec WD: 285O
s
GS em
M od AAQMS - 3
/ GP SM
AAQMS - 1 RS PR
M /G
od M
em GS
s
Meteorological
Sensors
CENTRAL PC
s
em
od
SM
PR
/G
M
GS
TITLE:
3 AAQMS with Central PC
SWAN TECHNICAL SERVICES PVT. LTD., BHARAT HEAVY ELECTRICALS LIMITED., DATE NAME
MADHAPUR, HYDERABAD HARIDWAR 14.12.2023 D. J. N. CHARY
DRAWN
CHECKED 16.12.2023 D. J. N. CHARY
AAQMS - 2 MATERIAL: VARIOUS APPROVED
PROJECT NAME:
SCALE: NTS SHEET: 4 OF 4 AMBIENT AIR QUALITY MONITORING STATIONS
ALL DIMENSIONS ARE IN MM
PROJECTION:
CUSTOMER: BHEL, HARIDWAR
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

f) Electrical Diagram of CAAQMS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

g) Electrical Diagram of 6KVA UPS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

26. CERTIFICATIONS OF INSTRUMENTS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FOR CAAQMS

Link for USEPA Authorization Certificate:


https://www.epa.gov/system/files/documents/2023-
12/list_of_frm_fem_-december_2023_final.pdf

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
List of Designated Reference and Equivalent Methods, December 15, 2023 Page 1

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY


CENTER FOR ENVIRONMENTAL MEASUREMENTS & MODELING
AIR METHODS & CHARACTERIZATION DIVISION (MD-D205-03)
Research Triangle Park, NC 27711

Office of
Research and Development

LIST OF DESIGNATED REFERENCE AND EQUIVALENT METHODS

Issue Date: December 15, 2023


(www.epa.gov/ttn/amtic/criteria.html)

These methods for measuring ambient concentrations of specified air pollutants have been designated as
"reference methods" or "equivalent methods" in accordance with Title 40, Part 53 of the Code of Federal
Regulations (40 CFR Part 53). Subject to any limitations (e.g., operating range or temperature range) specified in
the applicable designation, each method is acceptable for use in state or local air quality surveillance systems under
40 CFR Part 58 unless the applicable designation is subsequently canceled. Automated methods for pollutants other
than PM10 are acceptable for use only at shelter temperatures between 20°C and 30°C and line voltages between
105 and 125 volts unless wider limits are specified in the method description.
Prospective users of the methods listed should note (1) that each method must be used in strict accordance
with its associated operation or instruction manual and with applicable quality assurance procedures, and (2) that
modification of a method by its vendor or user may cause the pertinent designation to be inapplicable to the method
as modified. (See Section 2.8 of Appendix C, 40 CFR Part 58 for approval of modifications to any of these methods
by users.)
Further information concerning particular designations may be found in the Federal Register notice cited
for each method or by writing to the Center for Environmental Measurements and Modeling, Air Methods and
Characterization Division (MD-D205-03), U.S. Environmental Protection Agency, Research Triangle Park, North
Carolina 27711. Technical information concerning the methods should be obtained by contacting the source listed
for each method. Source addresses are listed at the end of the listing of methods, except for the addresses for lead
method sources, which are given with the method. New analyzers or PM10 samplers sold as reference or equivalent
methods must carry a label or sticker identifying them as designated methods. For analyzers or PM10 samplers sold
prior to the designation of a method with the same or similar model number, the model number does not necessarily
identify an analyzer or sampler as a designated method. Consult the manufacturer or seller to determine if a
previously sold analyzer or sampler can be considered a designated method or if it can be upgraded to designation
status. Analyzer users who experience operational or other difficulties with a designated analyzer or sampler and
are unable to resolve the problem directly with the instrument manufacturer may contact EPA (preferably in writing)
at the above address for assistance.
This list will be revised as necessary to reflect any new designations, modifications of existing designations,
or any cancellation of a designation currently in effect. The most current revision of the list will be available for
inspection at EPA's Regional Offices, and copies may be obtained at the Internet site identified above or by writing
to the Center for Environmental Measurements and Modeling at the address specified above.
SO2 List of Designated Reference and Equivalent Methods, December 15, 2023 Page 25

Dasibi Model 4108 U.V. Fluorescence SO2 Analyzer


Automated Equivalent Method: EQSA-1086-061
“Dasibi Model 4108 U.V. Fluorescence SO2 Analyzer,” operated with a range of 0-100 ppb1, 0-200 ppb1, 0-500 ppb, or 0-1000
ppb, with a Teflon-coated particulate filter and continuous hydrocarbon removal system, with or without any of the following
options: Rack Mounting Brackets and Slides; RS-232-C Interface; Temperature Correction.
Federal Register: Vol. 51, page 32244, 09/10/1986

DKK-TOA Corp. Model GFS-32 U.V. Fluorescent SO2 Analyzer


Automated Equivalent Method: EQSA-0701-115
“DKK-TOA Corporation Model GFS-32 Ambient Air SO2 Ultraviolet Fluorescent Analyzer,” operated within the 0.000 to
0.500 ppm range in the temperature range of 20°C to 30°C.
Federal Register: Vol. 62, page 44007, 08/18/1997

DKK-TOA Corp. Model GFS-112E U. V. Fluorescent SO2 Analyzer


Automated Equivalent Method: EQSA-0100-133
“DKK-TOA Corporation Models GFS-112E and GFS-112E-1 U.V. Fluorescence SO2 Analyzer,” operated at any temperature
ranging from 15oC to 35oC, on any of the following measurement ranges: 0-0.05 ppm1, 0-0.100 ppm1, 0-0.200 ppm1, 0-0.5
ppm, or 0-1.000 ppm, and with or without the optional Internal zero air supply and permeation tube oven.2
Federal Register: Vol. 65, page 2610, 01/18/2000

DKK-TOA Corp. Model GFS-312E, GFS-390 Ambient SO2 Analyzer


Automated Equivalent Method: EQSA-1107-168
“DKK-TOA Corporation Model GFS-312E or GFS-390 Ambient SO2 Analyzer,” operated at any environmental temperature
in the range of 20oC to 30oC on any of the following measurement ranges1: 0-0.1 ppm, 0-0.2 ppm and 0-0.5 ppm.2
Federal Register: Vol. 72, page 63176, 11/08/2007
Latest Modification: 05/2022

Ecotech or Acoem Australasia Serinus 50 Sulfur Dioxide Analyzer or Opsis AB OPS50 Sulfur Dioxide Analyzer or Teledyne
Analytical Instruments 6400E Sulfur Dioxide Analyzer or Tisch Environmental TE 2.0 Sulfur Dioxide Analyzer or Met
One Instruments GAS-1050 Sulfur Dioxide Analyzer or Met One Instruments GAS-1050-TL Sulfur Dioxide Analyzer
Automated Equivalent Method: EQSA-0809-188
“Ecotech or Acoem Australasia Serinus 50 Sulfur Dioxide Analyzer” or “Opsis AB OPS50 Sulfur Dioxide Analyzer” or
“Teledyne Analytical Instruments 6400E Sulfur Dioxide Analyzer” or “Tisch Environmental TE 2.0 Sulfur Dioxide
Analyzer,” operated in the range of 0–0.5 ppm, with a five-micron Teflon® filter element installed, with or without trace option
and with the following selected: Background-Enabled, Control Loop-Enabled, Diagnostic Mode-Operate, Pres/Temp/Flow
Compensation-Enabled, Span Compensation-Disabled, with concentration automatically corrected for temperature and
pressure changes, and operated according to the Serinus 50 Sulfur Dioxide Analyzer User Manual or the Opsis OPS50 Sulfur
Dioxide Analyzer User Manual or the Teledyne Analytical Instruments 6400E Sulfur Dioxide Analyzer Instruction Manual or
the Tisch Environmental TE 2.0 Sulfur Dioxide Analyzer Instruction Manual or Met One Instruments GAS-1050 Sulfur
Dioxide Analyzer Instruction Manual or Met One Instruments GAS-1050-TL Sulfur Dioxide Analyzer Instruction Manual, as
appropriate.
Federal Register: Vol. 74, page 38184, 07/31/2009
Latest Modifications: 05/2010, 05/2011, 05/2012, 8/2014, 12/2019, 11/2021; 07/2022

Environnement S.A. or ENVEA Model AF21M SO2 Analyzer


Automated Equivalent Method: EQSA-0292-084
“Environnement S.A. or ENVEA Model AF21M Sulfur Dioxide Analyzer,” operated on a range of 0-0.5 ppm with a response
time coefficient setting of 01, a Teflon filter installed in the rear-panel filter assembly, and with or without any of the following
options: Rack Mount/Slides; RS-232-C Interface.
Federal Register: Vol. 57, page 5444, 02/14/1992
Latest Modifications: 08/2020
NO2 List of Designated Reference and Equivalent Methods, December 15, 2023 Page 49

DKK-TOA Corporation Model GLN-314E or GLN-390 Nitrogen Oxides Analyzer


Automated Reference Method: RFNA-0508-171
“DKK-TOA Corporation Model GLN-314E or GLN-390 Nitrogen Oxides Analyzer,” operated at any temperature in the range
of 20oC to 30oC, on any of the following measurement ranges:1 0-0.100 ppm, 0-0.200 ppm, 0-0.500 ppm.2
Federal Register: Vol. 73, page 28819, 05/19/2008
Latest modification: 12/2022

Ecotech or Acoem Australasia Serinus 40 Oxides of Nitrogen Analyzer or Ecotech or Acoem Australasia Serinus 44
NO/NO2/NOx/NH3 Analyzer or Opsis AB OPS40 Oxides of Nitrogen Analyzer or Teledyne Analytical Instruments 9110E
Oxides of Nitrogen Analyzer or Tisch Environmental TE 4.0 Oxides of Nitrogen Analyzer or Met One Instruments GAS-
1040 Oxides of Nitrogen Analyzer or Met One Instruments GAS-1044 Oxides of Nitrogen Analyzer or Met One Instruments
GAS-1040-TL Oxides of Nitrogen Analyzer
Automated Reference Method: RFNA-0809-186
“Ecotech or Acoem Australasia Serinus 40 Oxides of Nitrogen Analyzer” or “Ecotech or Acoem Australasia Serinus 44
NO/NO2/NOx/NH3 Analyzer” “Opsis AB OPS40 Oxides of Nitrogen Analyzer” or “Teledyne Analytical Instruments 9110E
Oxides of Nitrogen Analyzer” or “Tisch Environmental TE 4.0 Oxides of Nitrogen Analyzer,” operated in the range of 0–0.5
ppm, with a five-micron Teflon® filter element installed, with or without trace option, with either a molybdenum or a vitreous
carbon NO2 to NO catalyst, and with the following selected: Control Loop-Enabled, Diagnostic Mode-Operate, Pres/Temp/Flow
Compensation-Enabled, Span Compensation-Disabled, with concentration automatically corrected for temperature and pressure
changes, and operated according to the Serinus 40 Oxides of Nitrogen Analyzer User Manual or the Serinus 44 NO/NO2/NOX/NH3
Analyzer User Manual or the OPS40 Oxides of Nitrogen Analyzer User Manual or the Teledyne Analytical Instruments 9110E
Oxides of Nitrogen Analyzer Instruction Manual or Tisch Environmental TE 4.0 Oxides of Nitrogen Analyzer Instruction Manual
or Met One Instruments GAS-1040 Oxides of Nitrogen Analyzer Instruction Manual or Met One Instruments GAS-1044 Oxides
of Nitrogen Analyzer Instruction Manual or Met One Instruments GAS-1040-TL Oxides of Nitrogen Analyzer Instruction Manual
as appropriate.
Federal Register: Vol. 74, page 38184, 07/31/2009
Latest Modifications: 05/2010; 05/2011; 05/2012; 03/2013; 08/2014; 7/2017; 12/2019; 11/2021; 07/2022

Ecotech or Acoem Australasia Serinus 60 or Met One Instruments GAS-1060 NO2 CAPS (Cavity Attenuated Phase Shift)
Analyzer
Automated Reference Method: EQNA-0217-242
“Ecotech or Acoem Australasia Serinus 60 NO2 CAPS (Cavity Attenuated Phase Shift) Analyzer” operated at temperatures
between 20°C and 45°C, a line voltage between 80V and 260V, and with or without any of the following options: rack mounts,
internal pump, internal permeation device, high pressure calibration ports, Ethernet output. The following menu choices must
be selected: Control Loop - Enabled; Diagnostic Mode - Operate; Pres/Temp/Flow Compensation - Enabled; Span
Compensation – Disabled; and operated according to the Serinus 60 or Met One Instruments GAS-1060 User Manual.
Federal Register: Vol. 82, page 27816, 6/19/2017
Latest Modifications: 11/2021; 07/2022

Environnement S. A. or ENVEA Model AC31M NO2 Analyzer


Automated Reference Method: RFNA-0795-104
“Environnement S. A. or ENVEA Model AC31M Chemiluminescent Nitrogen Oxide Analyzer,” operated with a full scale range
of 0 - 500 ppb, at any temperature in the range of 15°C to 35°C, with a 5-micron PTFE sample particulate filter, with the following
software settings: Automatic response time ON; Minimum response time set to 60 seconds (RT 2); and with or without any of the
following options:2 Internal Permeation Oven; Connection for Silica Gel Dryer; RS232-422 interface; EV3 valve; Internal Printer.
Federal Register: Vol. 60, page 38326, 07/26/1995
Latest Modifications: 08/2020
CO List of Designated Reference and Equivalent Methods, December 15, 2023 Page 42

Ecotech or Acoem Australasia Serinus 30 Carbon Monoxide Analyzer or Opsis AB OPS 30 Carbon Monoxide Analyzer or
Teledyne Analytical Instruments GFC7001E Carbon Monoxide Analyzer or Tisch Environmental TE 3.0 or Met One
Instruments GAS-1030 or Met One Instruments GAS-1030-TL Carbon Monoxide Analyzer
Automated Reference Method: RFCA-0509-174
“Ecotech or Acoem Australasia Serinus 30 Carbon Monoxide Analyzer” or “Opsis AB OPS30 Carbon Monoxide Analyzer”
or “Teledyne Analytical Instruments GFC7001E Carbon Monoxide Analyzer” or ”Tisch Environmental TE 3.0 Carbon
Monoxide Analyzer,” operated in the range of 0-50 ppm without the trace option, or 0-40 ppm range with the trace option
(Firmware 4.20 or later required for trace), with a five-micron Teflon® filter element installed, and with the following selected:
Background–Enabled, Control Loop–Enabled, Diagnostic Mode–Operate, Pres/Temp/Flow Compensation–Enabled, Span
Compensation–Disabled, with concentration automatically corrected for temperature and pressure changes, and operated
according to the Serinus 30 Carbon Monoxide Analyzer User Manual or the OPS 30 Carbon Monoxide Analyzer User Manual
or the Teledyne Analytical Instruments GFC7001E Carbon Monoxide Analyzer Instruction Manual, or the Tisch
Environmental TE 3.0, or the Met One Instruments GAS-1030 or Met One Instruments GAS-1030-TL Carbon Monoxide
Analyzer Instruction Manual as appropriate.
Federal Register: Vol. 74, page 26395, 06/02/2009
Latest Modifications: 05/2010; 05/2011; 05/2012; 08/2014; 11/2021, 07/2022, 08/2022

Environnement S.A. or ENVEA Model CO11M CO Analyzer


Automated Reference Method: RFCA-0995-108
“Environnement S.A. or ENVEA Model CO11M Ambient Carbon Monoxide Analyzer,” operated on a full scale range of 0 -
50 ppm, at any temperature in the range of 15°C to 35°C, with a 5-micron PTFE sample particulate filter, with the following
software settings: Automatic response time ON; Minimum response time set to 40 seconds (RT 13); Automatic ZERO-REF
cycle programmed every 24 hours; and with or without any of the following options: 2 RS232-422 Serial Interface; Internal
Printer.
Federal Register: Vol. 60, page 54684, 10/25/1995
Latest Modifications: 08/2020

Environnement S.A. or ENVEA Model CO12M CO Analyzer


Automated Reference Method: RFCA-0206-147
“Environnement S.A. or ENVEA Model CO12M Gas Filter Correlation Carbon Monoxide Analyzer,” operated with a full-
scale range of 0 - 50 ppm, at any temperature in the range of 10°C to 35°C, with a 5-micron PTFE sample particulate filter,
with response time ON, and with the automatic “ZERO-REF” cycle either ON or OFF.2
Federal Register: Vol. 67, page 42557, 06/24/2002
Latest Modifications: 08/2020

Environnement S.A. or ENVEA Model CO12e CO Analyzer


Automated Reference Method: RFCA-0915-228
“Environnement S.A. or ENVEA Model CO12e Carbon Monoxide Analyzer”, an infrared absorption spectroscopy technique
operated on a full scale range of 0 - 50 ppm, at any temperature in the range of 10°C to 35°C, with a teflon sample particulate
filter with the following software settings: Automatic response time ON; Automatic “ZERO-REF” cycle either ON or OFF,
with or without the solar panel option installed and with or without the following options: ESTEL Analog Input/Output Board,
LCD color touch screen and Carbon Dioxide CO2 sensor. Analyzer operated and maintained in accordance with the Model
CO12e Technical Manual, and operating from a 115V/ 60Hz, 230V/50Hz or 24Vdc power source.
Federal Register: Vol. 80, page 72432, 11/19/2015
Latest Modifications: 08/2020, 06/2022

Focused Photonics Inc. (FPI) Model AQMS-400 CO Analyzer


Automated Reference Method: RFCA-0419-252
“Focused Photonics Inc. AQMS-400 CO Analyzer” non-dispersive infrared (NDIR) analyzer operated in the range of 0–50
ppm, with 5 µm, 47 mm diameter Teflon® (PTFE) filter installed, operated at temperatures between 20°C and 30°C, at nominal
input line voltage of 220±10% VAC and frequency of 50 Hz, at a nominal sampling flow rate of 800±80 cc/min, and operated
according to the FPI AQMS-400 User Manual.
Federal Register: Vol. 84, page 24508, 5/28/2019
O3 List of Designated Reference and Equivalent Methods, December 15, 2023 Page 34

Ecotech or Acoem Australasia Serinus 10 Ozone Analyzer or Opsis AB OPS10 Ozone Analyzer or Tisch Environmental TE
1.0 or Met One Instruments Gas 1010 Ozone Analyzer
Automated Equivalent Method: EQOA-0809-187
“Ecotech or Acoem Australasia Serinus 10 Ozone Analyzer” or “Opsis AB OPS10 Ozone Analyzer” or “Tisch Environmental
TE 1.0 Ozone Analyzer,” operated in the range of 0–0.5 ppm, with a five-micron Teflon® filter element installed, and with the
following selected: Control Loop-Enabled, Diagnostic Mode-Operate, Pres/Temp/Flow Compensation-Enabled, Span
Compensation-Disabled, with concentration automatically corrected for temperature and pressure changes, and operated
according to the Serinus 10 Ozone Analyzer User Manual, or the Opsis AB OPS10 Ozone Analyzer User Manual, or the Tisch
Environmental TE 1.0 Ozone Analyzer Instruction Manual or the Met One Instruments GAS-1010 User Manual, as appropriate.
Federal Register: Vol. 74, page 38184, 07/31/2009
Latest Modifications: 05/2010; 05/2012; 8/2014; 11/2021, 07/2022

Environics Series 300 Ozone Analyzer


Automated Equivalent Method: EQOA-0990-078
“Environics Series 300 Computerized Ozone Analyzer,” operated on the 0-0.5 ppm range, with the following parameters
entered into the analyzer's computer system: Absorption Coefficient = 308 4; Flush Time = 3; Integration Factor = 1; Offset
Adjustment = 0.025 ppm; Ozone Average Time = 4; Signal Average = 0; Temp/Press Correction = On; and with or without the
RS-232 Serial Data Interface.
Federal Register: Vol. 55, page 38386, 09/18/1990

Environnement S.A. or ENVEA Model O3 41M UV Ozone Analyzer


Automated Equivalent Method: EQOA-0895-105
“Environnement S.A. or ENVEA Model O341M UV Photometric Ozone Analyzer,” operated on a full scale range of 0 - 500
ppb, at any temperature in the range of 15°C to 35°C, with the response time set to 50 seconds, and with or without any of the
following options:2 Internal Ozone Generator; Span External Control; RS232-422 Serial Interface; Internal Printer.
Federal Register: Vol.60, page 39382, 08/02/1995
Latest Modifications: 08/2020

Environnement S.A. or ENVEA Model O3 42M UV Ozone Analyzer


Automated Equivalent Method: EQOA-0206-148
“Environnement S.A. or ENVEA Model O342M UV Photometric Ozone Analyzer,” operated with a full scale range of 0 - 500
ppb, at any temperature in the range of 10°C to 35°C, with a 5-micron PTFE sample particulate filter, with response time setting
of 11 (Automatic response time), and with or without any of the following options:2 a) Internal ozone generator, b) Span
external control (zero/span solenoid valve).
Federal Register: Vol.67, page 42557, 06/24/2002
Latest Modifications: 08/2020

Environnement S.A. or ENVEA SANOA Multigas Longpath Monitoring System


Automated Equivalent Method: EQOA-0400-137
“Environnement S.A. or EVNEA Model SANOA Multigas Longpath Air Quality Monitoring System, consisting of a receiver,
one or more projectors, interface unit, a user-provided control unit computer running the SANOA VisionAIR software, and
associated incidental equipment; configured for measuring O3, with the temperature control and internal calibration cell options
installed, operated with a measurement range of 0 to 0.5 ppm, over an installed monitoring path length of between 27 and 500
meters, within an ambient air temperature range of -30 to +45°C, with a measurement (integrating) time of 180 seconds, and
with or without external temperature and barometric pressure sensors or any of the following options: external (meteo) input
connection, series 1M bus connection, OGR type projector, analog outputs. A high-concentration ozone generator, part # 80-
231-03, or the SONIMIX 7121B calibration system is recommended for calibration or accuracy auditing.
Federal Register: Vol.65, page 26603, 05/08/2000
Latest Modifications: 08/2020
PM2.5 List of Designated Reference and Equivalent Methods, December 15, 2023 Page 14

Met One Instruments, Inc. BAM-1020 Monitor – PM2.5 FEM Configuration, Horiba APDA-371– PM2.5 Configuration, or
Ecotech or Acoem Australasia Spirant BAM1100
Automated Equivalent Method: EQPM-0308-170
“Met One Instruments, Inc. BAM-1020 Beta Attenuation Mass Monitor – PM2.5 FEM Configuration, Horiba Instruments
APDA-371 Beta Attenuation Mass Monitor – PM2.5 FEM Configuration, or Ecotech or Acoem Australasia Spirant BAM1100”,
configured with the standard BX-802 EPA PM10 inlet (or alternative louvered PM10 inlet meeting 40 CFR 50 Appendix L
specifications) and with a BGI VSCC™ Very Sharp Cut Cyclone or Tisch TE-PM2.5C particle size separator, operated for 24
1-hour average measurements with firmware revision 3.2.4 or later, with or without an inlet tube extension (BX-823), with or
without external enclosures BX-902 or BX-903 and equipped with BX-596 ambient temperature and barometric pressure
combination sensor, or BX-597 ambient temperature, barometric pressure, relative humidity combination sensor, internal BX-
961 automatic flow controller operated in Actual (volumetric) flow control mode, the standard BX-802 EPA PM10 inlet head
and a BGI Very Sharp Cut Cyclone (VSCC™ -A) or Tisch TE-PM2.5C cyclone, BX-827 (110V) or BX-830 (230V) Smart Inlet
Heater, with the heater RH set to 35% and the temperature control set to "off", the 8470-1 revision D or later tape control
transport assembly with close geometry beta source configuration, used with standard glass fiber filter tape (460130 or 460180),
COUNT TIME parameter set for 8 minutes, the SAMPLE TIME parameter set for 42 minutes, BX-302 zero filter calibration
kit required and with or without BX-965 report processor board, or with or without BX-970 touch-screen display with USB
interface. Instrument must be operated in accordance with the BAM 1020 Particulate Monitor operation manual, revision F or
later, the Horiba APDA-371 Monitor operation manual or the Ecotech or Acoem Australasia Spirant BAM Manual (rev. A or
later), as appropriate, and the VSCC™ or Tisch TE-PM2.5C supplemental manual and may employ either the standard or
advanced leak test procedure. For instruments running firmware V9.0.0 or later, P/N BX-597A (digital temperature, pressure,
humidity) must be used.
Federal Register: Vol. 73, page 13224, 03/12/2008
Latest modifications: 7/2010; 8/2010; 8/2012; 3/2015; 9/2015; 4/2017; 12/2018; 08/2020; 11/2021

Met One Instruments, Inc. BAM-1020 Beta Attenuation Mass Monitor- PM2.5 FEM Configuration, or Ecotech or Acoem
Australasia Spirant BAM1100
Automated Equivalent Method: EQPM-0715-266
“Met One Instruments, Inc. BAM-1020 Beta Attenuation Mass Monitor – PM2.5 FEM Configuration or Ecotech or Acoem
Australasia Spirant BAM1100,” configured for 24 1-hour average measurements of PM2.5 by beta attenuation, using a glass
fiber filter tape roll (460130 or 460180) and a sample flow rate of 16.67 liters/min and with the standard EPA PM10 inlet
(meeting 40 CFR 50 Appendix L specifications) and with a URG-2000-30EGN PM2.5 (BX-809) cyclonic separator, BX-596
combo T/BP sensor or BX-597 combo T/BP/RH sensor, BX-827 (110V) or BX-830 (230 V) and with or without BX-965 report
processor board and with or without BX-970 touch screen display. Instrument must be operated in accordance with the BAM
1020 Particulate Monitor operation manual, revision L or later or with Ecotech or Acoem Australasia Spirant BAM1100
Operators Manual and may employ either the standard or advanced leak test procedure. Instrument must be operated with
firmware revision 3.2.4 or later. This PM2.5 equivalent method designation only applies to the BAM-1020 or BAM1100
configured with the URG-2000-30EGN cyclone. For instruments running firmware V9.0.0 or later, P/N BX-597A (digital
temperature, pressure, humidity) must be used.
Federal Register: Vol. 80, page 51802, 8/26/2015
Latest modification: 04/2017; 10/2018; 12/2018; 08/2020; 11/2021

Met One Instruments, Inc. BAM-1022 Real Time Beta Attenuation Mass Monitor-Outdoor PM2.5 FEM Configuration
Automated Equivalent Method: EQPM-1013-209
“Met One Instruments, Inc. BAM-1022 Beta Attenuation Mass Monitor – Outdoor PM2.5 FEM Configuration,” configured for
24 1-hour average measurements of PM2.5 by beta attenuation, using a glass fiber filter tape roll (460130 or 460180) and a
sample flow rate of 16.67 liters/min and with the standard (BX-802) EPA PM10 inlet (meeting 40 CFR 50 Appendix L
specifications) and with a BGI VSCC™ Very Sharp Cut Cyclone (BX-808) or Tisch TE-PM2.5C particle size separator, and
equipped with external enclosure BX-922 and BX-592 ambient temperature sensor or BX-596 ambient temperature/barometric
combination sensor or BX-597 ambient temperature/barometric pressure/relative humidity combination sensor. Instrument
must be operated in accordance with the BAM 1022 Particulate Monitor operation manual, revision B or later and may employ
either the standard or advanced leak test procedure. This designation applies to PM2.5 measurements only.
Federal Register: Vol. 78, page 67360, 11/12/2013
Latest modifications: 7/2014; 10/2015; 3/2016; 12/2018; 10/2019
PM10 List of Designated Reference and Equivalent Methods, December 15, 2023 Page 7

Met One or Sibata Models BAM/GBAM 1020, BAM/GBAM 1020-1, Horiba APDA-371, or Ecotech or Acoem Australasia
Spirant BAM1000
Automated Equivalent Method: EQPM-0798-122
“Met One Instruments or Sibata Scientific Technology Models BAM 1020, GBAM 1020, BAM 1020-1, GBAM 1020-1, Horiba
APDA-371 PM10 Beta Attenuation Monitor, or Ecotech or Acoem Australasia Spirant BAM1000 Spirant BAM1000” including
the BX-802 EPA PM10 inlet (or alternative louvered PM10 inlet meeting 40 CFR 50 Appendix L specifications), operated for
24-hour average measurements, with a filter change frequency of one hour, with glass fiber filter tape (460130 or 460180), and
with or without any of the following options: BX-823, tube extension; BX-825, heater kit; BX-826, 230 VAC heater kit; BX-
-828, roof tripod; BX-902,
exterior enclosure; BX-903, exterior enclosure with temperature control; BX-961, mass flow controller; BX-967, internal
calibration device, BX-965 Report Processor Board, BX-970 touch-screen display with USB interface. For software (firmware)
versions V3.0 or higher, a user-selectable measurement time (COUNT TIME) of 4, 6, 8 or 10 minutes selected, along with
appropriate sample time (BAM SAMPLE) setting of 50, 46, 42 or 38 minutes, respectively, to maintain a 60-minute
measurement cycle. For software (firmware) versions V3.5 or higher, user-selectable option to sample under actual conditions
(Flow Type: ACTUAL) and report under standard conditions (Reporting: STD), which requires the use of P/N BX-592 external
temperature sensor or P/N BX-596 external temperature/barometric pressure sensor, or BX-597 external
temperature/barometric pressure/relative humidity sensor. The user may also sample under standard conditions (Flow Type:
STD) and report under standard conditions (Reporting: STD) with any software/firmware 2.0 or higher. For instruments running
firmware V9.0.0 or later, P/N BX-598 (digital temperature) or P/N BX-597A (digital temperature, pressure, humidity) must be
used. Instrument must be operated in accordance with the appropriate instrument manual and may employ either the standard
or advanced leak test procedure.
Federal Register: Vol. 63, page 41253, 08/03/1998
Latest modifications: 06/2009; 07/2010; 8/2010; 8/2012; 4/2017; 12/2018; 08/2020; 11/2021

Met One Instruments, Inc. E-BAM PLUS Beta Attenuation Mass Monitor- PM10 FEM Configuration
Automated Equivalent Method: EQPM-1215-226
“Met One Instruments, Inc. E-BAM PLUS Beta Attenuation Mass Monitor – PM10 FEM Configuration,” configured for 24 1-
hour average measurements of PM10 by beta attenuation, using a glass fiber filter tape roll (460130 or 460180), a sample flow
rate of 16.67 liters/min, with the standard (BX-802) EPA PM10 inlet (meeting 40 CFR 50 Appendix L specifications) and
equipped with 9250 ambient temperature sensor or BX-597 T/BP/RH combination sensor. Instrument must be operated in
accordance with the E-BAM PLUS Particulate Monitor operation manual, revision 1 or later and may employ either the
standard or advanced leak test procedure. This designation applies to PM10 measurements only.
Federal Register: Vol. 81, page 4294, 01/26/2016
Latest modification: 04/2017; 12/2018

Met One Instruments, Inc. E-FRM– PM10 or E-FRM-DC-PM10


Manual Reference Method: RFPS-0216-231
“Met One Instruments, Inc. E-FRM,” configured for filter sampling of ambient particulate matter using the US EPA PM10 inlet
specified in 40 CFR 50 Appendix L, Figs. L-2 thru L-19, equipped with an external sampling pump (E-FRM–PM2.5) or internal
sampling pump (E-FRM-DC-PM2.5), with a flow rate of 16.67 L/min, using 47 mm PTFE membrane filter media, and operating
with firmware version R2.0.1 and later, and operated in accordance with the Met One E-FRM PM10 operating manual. This
designation applies to PM10 measurements only.
Federal Register: Vol. 81, page 25397, 04/28/2016
Latest modification: 11/14/2017

Met One Instruments, Inc. E-SEQ-FRM PM10 Sampler


Manual Reference Method: RFPS-0717-246
“Met One Instruments, Inc. E-SEQ-FRM,” sequential sampler configured for multi-event filter sampling of ambient particulate
matter using the US EPA PM10 inlet specified in 40 CFR 50 Appendix L, Figs. L-2 thru L-19, with a flow rate of 16.67 L/min,
using 47 mm PTFE membrane filter media, and operating with firmware version R1.1.0 and later, and operated in accordance
with the Met One E-SEQ-FRM PM10 operating manual. This designation applies to PM10 measurements only.
Federal Register: Vol. 82, page 44613, 09/25/2017
Latest modification: 08/2019
PRODUCT CONFORMITY CERTIFICATE
This is to certify that the

Manufactured by:

airmotec AG
(Chromatotec Group)
-Antoine
33240 Val de Virvée
France

has been assessed by CSA Group


and for the conditions stated on this certificate complies with:

MCERTS performance standards for


- Published 6 December 2022
EN 15267-1:2009, EN 15267-2:2009 & EN 14662-3:2015

Certification ranges:

Airborne Benzene Vapour : 0 to 50 µg/m3

Project number: 80172261


Certificate number: CSA MC130230/07
Initial certification: 26 July 2013
This certificate issued: 28 June 2023 Andrew Young
Renewal date: 25 July 2028 Environmental Team Manager
MCERTS is operated on behalf of the Environment Agency by
CSA Group Testing UK Ltd
Unit 6, Hawarden Industrial Park
Hawarden, Deeside, CH5 3US
Tel: +44 (0)1244 670 900

The MCERTS certificate consists of this document in its entirety.


For conditions of use, please consider all the information within.
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 1 of 6
Form 1335
Issue 11
Certificate Contents
Approved Site Application........................................................................................................ 2
Basis of Certification ............................................................................................................... 2
Product Certified..................................................................................................................... 3
Certified Performance ............................................................................................................. 4
General Notes ........................................................................................................................ 6

Approved Site Application

Any potential user should ensure, in consultation with the manufacturer, that the monitoring system
is suitable for the intended application. For general guidance on monitoring techniques refer to the
Environment Agency Monitoring Technical Guidance Notes available at www.mcerts.net

All tests have been conducted in accordance with BS EN 14662-3:2015.


11 lab tests
4 field tests over 3 months

The field trial was conducted on an urban background site for 3 months Marylebone Road in
Central London.

Test data for other VOCs can be found in the NPL test report listed below, contact Chromatotec
directly for details.

MCERTS Manufacturing Audit based on EN 15267-2 and ISO 9001 was conducted on 5th May
2018, Report number 70172875

Basis of Certification

This certification is based on the following test report(s) and on CSA Group
ongoing surveillance of the product and the manufacturing process (annual audit):

The tests has been performed by National Physical Laboratory (UKAS 002 accredited for Benzene
(EN 14662-3) and VOC in compliance with ISO 17025)

NPL report number: E09040018 dated 14th June 2013 v2


CSA report number: 70072766 dated 2nd June 2016

Certificate No: CSA MC130230/07


This Certificate issued: 28 June 2023

Page 2 of 6
Form 1335
Product Certified

The Chromatotec® GC 866 PID airToxic (Model A73022) benzene measuring system consists of
the following parts:

Pneumatic valve: 6 ports


Analytical column: capillary metallic column
Detector: Photo ionisation detector (PID)

Vistachrom software version 1.49

This certificate applies to all instruments fitted with software version Vistachrom 1.49 (serial number
20190309) onwards.

Certificate No: CSA MC130230/07


This Certificate issued: 28 June 2023

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 3 of 6
Form 1335
Certified Performance

The instrument was evaluated for use under the following conditions:

Ambient Temperature Range: +18°C to +24°C

Note: If the instrument is supplied with an enclosure then the ambient temperature shall be monitored inside
the enclosure to ensure that it stays within the above ambient temperature range.
Two identical instruments tested in parallel, the worst result is reported below:
Test Test result MCERTS
specification

Laboratory tests

Repeatability standard deviation at 10% of limit value 0.03 µg/m3 g/m3

Repeatability standard deviation at limit value 0.18 µg/m3 g/m3

Lack of fit (residual from linear regression function) 4.60%

Sensitivity coefficient to sample gas pressure at span 0.013 µg/m3/kPa g/m3/kPa


value
Sensitivity coefficient to sample gas temperature 0.008 µg/m3/K g/m3/K
Sensitivity coefficient to electrical voltage 0.0015 µg/m3/V g/m3/V
Short term drift at span level 0.38 µg/m3 2.0 µg/m3

Response to organic compound mixture 0.14 µg/m3 g/m3


Effect of H2O at concentration of 19 mmol/mol 0.003 µg/m3
µg/m3/(mmol/mol)
Carry over (memory effect) 0.37 µg/m3 g/m3

Field tests Note 1


Reproducibility standard deviation under field 0.08 µg/m3 g/m3
conditions
Long term drift at span level 7.52%
maximum of the
certification range
Maintenance interval 90 days
Availability 99.9%
Expanded uncertainty (laboratory and field tests) 19.5%

Note 1: In the shelter during the three month field tests, another instrument emitted punctual N Butanol at
consistent concentrations that may have disturbed the zero air generator. The N Butanol emitted
was analysed in ambient air and did not interfere with the benzene measurement of the GC 866
PID airToxic.

Certificate No: CSA MC130230/07


This Certificate issued: 28 June 2023

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 4 of 6
Form 1335
Description

GC 866 PID airToxic (Model A73022)

Rack dimensions : 5 U monitor built as a 19" unit Width 483mm x Height 220mm 5U x Depth 660mm
(730mm with rear face connections)

Pneumatic Valve : 6 ports. High speed injection system (up to 350°C) with 'zero dead volume'
sample transfer to the column

Analytical column : Metallic capillary column

Detector : Photo Ionisation Detector (PID), lamp 10.6 eV, electrometer and 0-1 V analogue output,
Self-cleaning lamp for high stability

Sampling system : Gas flow control unit (sample volume calculated) with one critical orifice, linked
to a sampling pump

Trapping system : Enrichment unit with a drum equipped with 1 adsorbent tube packed with
CARBOTRAP, trapping at ambient temperature, thermo desorption up to 350°C

Carrier gas : N2 cylinder or generator. One electronic pressure control and one valve for N2 as carrier
gas that gives consistent retention time.

Calibration : Internal or external calibration with permeation tubes or cylinder, in order to perform
auto-calibration of the instrument.The permeation tube is regulated in temperature and in flow.
Method: Calib, Measure and Blank available in a sequence. It is possible to start a Calibration by
clicking on a button or starting automatic method in the sequence

Power supply : 110V, 60Hz or 230V, 50Hz.

Power consumption : 150 VA and peak to 360 (24 VDC power supply is available in option XXX005)

6 LEDs in front panel (running/sampling/stand by/ OK/ warning/error)

Software : Vistachrom version 1.49 onwards

Communication interface : Ethernet, RS 232, RS 485, USB, analogic/digital output

Communication protocol : Modbus RTU, Gesytec 1 (Bayer Essen), Gesytec 2, others possible on
request

Certificate No: CSA MC130230/07


This Certificate issued: 28 June 2023

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 5 of 6
Form 1335
General Notes

1. This certificate is based upon the equipment tested. The Manufacturer is responsible for
ensuring that on-going production complies with the standard(s) and performance criteria
defined in this certificate. The manufacturer is required to maintain an approved quality
management system controlling the manufacture of the certified product. Both the product
and the quality management system shall be subject to regular surveillance according to
CSA Group Testing UK Ltd

2. The design of the product certified is defined in the CSA Group design schedule V07 for
certificate No. CSA MC130230/07.

3. If a certified product is found not to comply, CSA Group should be notified immediately at the
address shown on this certificate.

4. The certification marks that can be applied to the product or used in publicity material are
CSA Group Testing UK Ltd Certificat

5. This document remains the property of CSA Group and shall be returned when requested by
CSA Group.

Certificate No: CSA MC130230/07


This Certificate issued: 28 June 2023

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 6 of 6
Form 1335
e

Declaration

This is to certify that we M/s. Acoem (formerly known as Ecotech Pty Ltd & Metone Instruments),
a manufacturer of ambient air quality monitoring gas analysers/Instruments, have supplied
numerous CO2 (Carbon Dioxide) Analyzers and CO (Carbon Monoxide) analysers. Currently the
same upgraded analyser for measuring CO2 is known as Serinus 31 and CO is known as Serinus
30. The Serinus 31 carbon dioxide (CO2) is manufactured based on the Serinus 30 CO (Carbon
Monoxide) analyser and both use Non-Dispersive Infrared Spectrophotometry (NDIR) technology
to provide accurate, stable, and repeatable measurements of gaseous CO2 and CO of ambient air.
As per the USEPSA List of Designated Reference and Equivalent Methods, TUV and MCERTS, the
carbon dioxide (CO2) is not and we hereby inform you that CO2 is not listed for any other
manufacturer.

Thanking you and assuring

For M/s. Acoem (formerly known as Ecotech Pty Ltd & Metone Instruments)

For Acoem Ecotech Industries Pvt. Ltd.,

Arun Nair
Manager Contracts & Commercial
Mobile +91 990 992 0384
E-mail: arun.nair@acoem.com
Manufacturer Authorization letter And
Confirmations from OEM towards PQR Points of Tender

Date: 06-06-2023

To, To,
Mr. Shashi Pal, Dy. Engineer(Project) Mr. Deshraj Yadav, Dy. Manager (PCRI-BOI)
Department of Heavy Industry Department of Heavy Industry
1x660MW Bhusawal Thermal Power Station 1x660MW Bhusawal Thermal Power Station
Unit 6, Unit 6
Bharat Heavy Electricals Limited(BHEL), Bharat Heavy Electricals Limited(BHEL),
MSPGCL, Bhusawal, HEEP, Haridwar, MSPGCL, Bhusawal, HEEP, Haridwar,
Dist Jalgaon, Dist Jalgaon,
Maharashtra-27, Pin-425307 Maharashtra-27, Pin-425307
Email ID: palsh@bhel.in
Tel : +91 1334 28 1941

Sub: Manufacturer Authorization letter for tender


AAQMS Analyzers and Accessories of AAQMS Analyzers at Chief/Deputy Engineer(Project) office, 1x660MW
Bhusawal Thermal Power Station Unit 6, Bharat Heavy Electricals Limited(BHEL), MSPGCL, Bhusawal,
HEEP, Haridwar, Jalgaon Dist, Maharashtra- for 3 against Tender Ref No: GEM Bid No.:
GEM/2023/B/3426349, Dt: 23.05.2023, Last date of Submission 13.06.2023

Dear Sir s,

This is to certify that, we M/s. ACOEM Ecotech Industries Pvt. Ltd (owned subsidiary of Ecotech, Australia & Met One
Instruments, USA) part of ACOEM Group, France; official manufacturers of SO2, NO-NO2-NOx, NH3, O3, CO, CO2
Gas Analysers and PM10 and PM2.5 Particulate Monitor / Analyzers for Continuous Ambient Air Quality Monitoring
application, having its corporate head office located 200 chem. Des Ormeaux, 69760 Limonest, FRANCE, and in India
M/s. ACOEM operates through its Indian operations / 100% subsidiary company M/s. ACOEM Ecotech Industries Pvt
Ltd., having its registered office / factory at Plot no.57, Sector 2, Dist.: Dhar, Pithmapur 454775, Madhya Pradesh and
is responsible for conduct of its operations in India on behalf of ACOEM Group of Companies and its global subsidiaries.
Please note that globally ACOEM Group is represented through its brands namely Ecotech, MetOne, Dynoptic, 01dB,
Oneprod, Fixturlaser, Meax and Metravib.

This is further to confirm that we M/s. ACOEM Ecotech Industries Pvt Ltd.,hereby authorize our distributor M/s. Swan
Technical Services Pvt. Ltd, a subsidiary company of Swan Environmental Private Limited (SWAN) existing under the
laws of India with its principle place of business at Plot No: 922 &935, Swamy Ayyappa Co-Operative Society,
Madhapur, Hyderabad-500081 to submit the bid with our make of Analyzers Proposal Supply, Installation, Testing
and Commissioning of AAQMS Analyzers and Accessories of AAQMS Analyzers at Chief/Deputy Engineer(Project)
office, 1x660MW Bhusawal Thermal Power Station Unit 6, Bharat Heavy Electricals Limited(BHEL), MSPGCL,
Bhusawal, HEEP, Haridwar, Jalgaon Dist, Maharashtra- for 3 along with Guaranty / Warranty Three
as per tender requirement and to subsequently negotiate and sign the contract.

Creating environments of possibility

Acoem Ecotech Industries Pvt. Ltd. *Registered Office & Factory: Plot No.57, Pithampur, Sector 2, Dist. Dhar 454775
Madhya Pradesh * +91 72 9242 6400 * CIN : U29190M2013PTC031610 * info.in@acoem.com * acoem.com
No Company or firm or individual other than M/s. Swan Technical Services Pvt. Ltd. Hyderabad are authorized to bid,
and conclude the contract for the above goods manufactured by us against this specific tender enquiry, without a
written authorization letter from us.

M/s. Swan Technical Services Pvt. Ltd. Hyderabad has experienced engineers trained at our premises and is capable
to install and maintain our equipment. We hereby extend our full guarantee and warranty (03) three years for the
Goods and Services offered by the above firm on our behalf. We hereby Declare and confirm the availability of
spare parts and consumables for at least ten (10) years following the initial supply of the instruments from the date
of placement of order.

We shall be providing our techno-commercial support, warranty support, maintenance support and spares support
through M/s. Swan Technical Services Pvt. Ltd for our make of instruments in India for 1x660MW Bhusawal Thermal
Power Station Unit 6, Bharat Heavy Electricals Limited(BHEL), MSPGCL, Bhusawal, HEEP, Haridwar, Jalgaon-Dist
towards the above referred tender enquiry.

Yours Faithfully
For ACOEM Ecotech Industries Pvt. Ltd.,

Arun Nair,
Manager Contracts & Commercial
Mobile +91 990 992 0384
E-mail: arun.nair@acoem.com

Creating environments of possibility

Acoem Ecotech Industries Pvt. Ltd. *Registered Office & Factory: Plot No.57, Pithampur, Sector 2, Dist. Dhar 454775
Madhya Pradesh * +91 72 9242 6400 * CIN : U29190M2013PTC031610 * info.in@acoem.com * acoem.com
Manufacturer Authorization letter And
Confirmations from OEM towards PQR Points of Tender

Date: 06-06-2023

To, To,
Mr. Shashi Pal, Dy. Engineer(Project) Mr. Deshraj Yadav, Dy. Manager (PCRI-BOI)
Department of Heavy Industry Department of Heavy Industry
1x660MW Bhusawal Thermal Power Station 1x660MW Bhusawal Thermal Power Station
Unit 6, Unit 6
Bharat Heavy Electricals Limited(BHEL), Bharat Heavy Electricals Limited(BHEL),
MSPGCL, Bhusawal, HEEP, Haridwar, MSPGCL, Bhusawal, HEEP, Haridwar,
Dist Jalgaon, Dist Jalgaon,
Maharashtra-27, Pin-425307, India, Maharashtra-27, Pin-425307, India,
Email ID: palsh@bhel.in
Tel : +91 1334 28 1941

Sub: Manufacturer Authorization letter cum confirmation from OEM towards PQR Points for providing
Certificate for Guarantee & Warranty Services and supply of spare parts for the work
Installation, Testing and Commissioning of AAQMS Analyzers and Accessories of AAQMS Analyzers at
Chief/Deputy Engineer(Project) office, 1x660MW Bhusawal Thermal Power Station Unit 6, Bharat
Heavy Electricals Limited(BHEL), MSPGCL, Bhusawal, HEEP, Haridwar, Jalgaon Dist, Maharashtra-
for 3
Submission 13.06.2023.

Dear Sir s,

We, Airmotec Ag (a Group company of CHROMATOTEC Inc.), a manufacturer of BTEX Analysers duly
organized and existing under the laws of France with its principle office of business at 15 Rue d, Artigue
longue, 33240 Saint-Antoine-France hereby authorize our distributor M/s. Swan Technical Services Pvt. Ltd, A
subsidiary company of Swan Environmental Private Limited., 922 &935, Swami Ayyappa Co-operative Society,
Madhapur, Hyderabad-500081 to submit a bid the purpose of which is to provide the above Goods,
manufactured by us and to subsequently negotiate and sign the Contract.

No Company or firm or individual other than M/s. Swan Technical Services Pvt. Ltd. Hyderabad are
authorized to bid, and conclude the contract for the above goods manufactured by us against this specific
tender enquiry, without a written authorization letter from us.

M/s. Swan Technical Services Pvt. Ltd. Hyderabad has experienced engineers trained at our premises
and is capable to install and maintain our equipment. We hereby extend our full guarantee and warranty (03)
three years for the Goods and Services offered by the above firm on our behalf. We confirm the availability of
spare parts and consumables for at least ten (10) years following the initial supply of the instruments from the
date of placement of order.
Airmotec Ag (a Group company of CHROMATOTEC Inc.) hereby confirms that offering analyzers
models are upgraded / latest and meets all PQR points of tender. Our technical support to Swan Technical
Services Pvt. Ltd. Hyderabad, as and when required during Warranty and AMC for the equipment supplied by
us for this tender against.

Yours Sincerely,

Jean-Philippe AMIET
M.Sc. Sales and Customer Service Manager
AIRMOTEC AG S.A / CHROMATOTEC

33240 Saint Antoine, France


Tel: +33 (0) 5 57 94 95 09
E-mail: jean-philippe.amiet@chromatotec.com
SWAN TECHNICAL SERVICES PVT LTD BHARAT HEAVY ELECTRICALS LIMITED MAHAGENCO

DOCUMENT TITLE: DATA DOC No.: 69-PC-36-01 REVISION: 03


SHEET FORCAAQMS

27.CATALOGUES OF INSTRUMENTS

COPYRIGHT AND CONFIDENTIAL


THE INFORMATION ON THIS DOCUMENT IS THE PROPERTY OF MAHAGENCO, BHARAT HEAVY ELECTRICALS MITED AND SWAN
TECHNICAL SERVICES PVT LTD IN ALLIANCE. IT MUST NOT BE USED DIRECTLY OR NDIRECTLY IN ANY WAY DETRIMENTAL TO
THE INTEREST OF THE COMPANY
Serinus 50 ®
Sulfur Dioxide Analyser

The Serinus® 50* sulfur dioxide (SO2) analyser


delivers precise and reliable performance at
excellent value.
It uses proven pulsed UV fluorescent radiation
technology to measure SO2 in ambient air
(LDL < 0.3 ppb, range 0 to 20 ppm).

* Acoem Serinus 50 formerly known as Ecotech Serinus 50.

acoem.com
Approvals
•   US EPA approval (EQSA-0809-188) •   French approval LSCQA

•   EN approval TÜV (0000040205-02) •   Ukraine approval (12/3/B/24/295-17)

•   Australian Standard (AS 3580.5.1-2011) •   Chinese Pattern Approval (JJF1361-2012)

•   Russian approval (56263-14) •   Korean approval NIER (AACMS-2017-04)

Benefits
The Serinus® range of analysers have been designed •  Latest firmware updates can easily be installed
using our experience & knowledge gained from using the USB flash memory drive
operating large air quality monitoring networks for
•  Programming, viewing, downloading & emailing of
more than 45 years. The result, instruments that
data is made even simpler using optional Bluetooth
integrate seamlessly into continuous monitoring
connectivity combined with the Serinus Remote
networks.
Android App
•  Reliable performance complemented with a two
•  Built-in digital display measuring values & having
year warranty
function of measuring values transferred to
•  Minimise time spent on site performing graphical trend display
maintenance through superior remote instrument
•  Enhanced operator safety through the use of
control, diagnostic viewing & calibration
12 VDC internal voltages
•  Comprehensive data logging & remote viewing of
•  Reduced cost of spare parts, accessories &
over 200 operational parameters
consumable items through extensive use of
•  Versatile interfacing through RS232, analog & standard components across the Serinus range
digital I/O & optional TCP/IP & Bluetooth
•  Rack slide design makes accessing internal
•  Easy setup through an intuitive menu system, components & removing the analyser from a rack
advanced GUI & a large alphanumeric keypad with cabinet easy
tactile keys
•  AQMS power usage can be reduced due to the
•  Instant status indication via illuminated instrument instrument’s low power demand & its ability to
status light buttons on the front panel operate over a wide temperature range.

•  Removable flash memory stores ~ 10 years of


data, including up to 12 individual parameters &
event logs. Operational parameters can also be
transferred to memory for easy retrieval

acoem.com | 2
Specifications
Range: 0 - 20 ppm (autoranging)
Concentration units: mg/m3, μg/ m3, ng/m3, ppm, ppb or ppt
Noise: < 0.15 ppb
Lower detectable limit: < 0.3 ppb 0.2 % of concentration whichever is greater
Linearity: < 1 % of full scale
Precision: 0.5 ppb or 0.5 % of reading whichever is greater
Zero drift: 24 hours: < 0.5 ppb
7 days: < 0.5 ppb
Span drift: 24 hours: < 0.5 % of reading or < 0.5 ppb whichever is greater
Response time: 60 seconds to 95 %
STP reference: 0 °C, 20 °C, 25 °C at 101.3 kPa
Sample flow rate: 725 cc/min
Temperature range: 0 - 40 °C
Power: 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption: 255 VA (max at start-up)
180 VA (nominal)
Dimensions: 429 x 175 x 638 mm
Rack spacing: 3.5 RU
Weight: 18.1 kg

Measurement Cell

Calibration Valve Manifold

Zero Air Scrubber

Sample Filter Holder

Reaction Cell

Hydrocarbon Kicker

Lamp Driver

acoem.com | 3
Communication Data logging
• #1 RS232 port (supports all protocols*) • 8 GB removable USB flash memory drive that
• #2 RS232 port (supports all protocols* & stores the internal data logger, event log,
multidrop) automatic/manual configuration backup &
• USB port (Advanced protocol only) automatic/manual parameter list save
• Bluetooth (Advanced protocol only) • Internal data logger (can log up to 12 of
• TCP/IP network port (optional, supports all 200+ parameters)
protocols*). • Logger interval (1 second to 24 hours)
• Storage capacity ~ 10 years
* Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or Advanced
(set to 1 minute interval).

Communication analog & Options & accessories


digital I/O port: • TCP/IP Network Port
• Bluetooth
• 3 x analog outputs (current or voltage),
• Dual Sample (particulate) Filter
12 bit resolution user definable range
• High Pressure Span (for direct cylinder calibration)
(between two user specified points)
• High Pressure Zero (for direct cylinder calibration)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA
• Test Lamp (for PMT diagnostics)
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset
• Internal DC Pump (long life, low power, minimal
of 0 V, 0.25 V or 0.5 V)
maintenance)
• 3 x analog inputs (scalable), 0 - 5 V,
• Metric Fitting Kit (to connect 6 mm tube to
16 bit resolution
rear ports)
• 8 x logic level digital control inputs
• 19” Rack Mount Kit
• 8 x open collector digital status outputs.
• External Pump (240 or 110 VAC)
• Annual Maintenance Kit
• Printed User Manual (a soft copy of the user
manual is supplied on USB with each analyser).

Specifications subject to change without notice. Images used are for illustrative purposes
only. All trademarks and registered trademarks are the property of their respective owners.

© 2023 Acoem and all related entities. All rights reserved. 20230220

acoem.com
Serinus 40 ®
Oxides of Nitrogen Analyser

The Serinus® 40* Oxides of Nitrogen (NOx) analyser


delivers precise and reliable performance at
excellent value.

It uses proven chemiluminescence technology to


measure NO, NO2 and NOx in ambient air
(LDL < 0.4 ppb, range 0 to 20 ppm).

* Acoem Serinus 40 formerly known as Ecotech Serinus 40.

acoem.com
Approvals
•   US EPA approval (RFNA–0809–186) •   French approval LSCQA

•   EN approval TÜV (0000040204 -02) •   Ukraine approval (12/3/B/24/295-17)

•   Australian Standard (AS 3580.5.1-2011) •   Chinese Pattern Approval (JJF1361-2012)

•   Russian approval (56263-14) •   Korean approval NIER (AACMS-2017-01)

Benefits
The Serinus® range of analysers have been designed •  Latest firmware updates can easily be installed
using our experience & knowledge gained from using the USB flash memory drive
operating large air quality monitoring networks for
•  Programming, viewing, downloading & emailing of
more than 45 years. The result, instruments that
data is made even simpler using optional Bluetooth
integrate seamlessly into continuous monitoring
connectivity combined with the Serinus Remote
networks.
Android App
•  Reliable performance complemented with a two
•  Built-in digital display measuring values & having
year warranty
function of measuring values transferred to
•  Minimise time spent on site performing graphical trend display
maintenance through superior remote instrument
•  Enhanced operator safety through the use of
control, diagnostic viewing & calibration
12 VDC internal voltages
•  Comprehensive data logging & remote viewing of
•  Reduced cost of spare parts, accessories &
over 200 operational parameters
consumable items through extensive use of
•  Versatile interfacing through RS232, analog & standard components across the Serinus range
digital I/O & optional TCP/IP & Bluetooth
•  Rack slide design makes accessing internal
•  Easy setup through an intuitive menu system, components & removing the analyser from a rack
advanced GUI & a large alphanumeric keypad with cabinet easy
tactile keys
•  AQMS power usage can be reduced due to the
•  Instant status indication via illuminated instrument instrument’s low power demand & its ability to
status light buttons on the front panel operate over a wide temperature range.

•  Removable flash memory stores ~ 10 years of


data, including up to 12 individual parameters &
event logs. Operational parameters can also be
transferred to memory for easy retrieval

acoem.com | 2
Specifications
Range: 0 - 20 ppm (autoranging)
Concentration units: mg/m3, μg/ m3, ng/m3, ppm, ppb or ppt
Noise: < 0.2 ppb
Lower detectable limit: < 0.4 ppb
Linearity: ± 1 % of full scale
Precision: 0.4 ppb or 0.5 % of reading, whichever is greater
Zero drift: 24 hours: < 0.5 ppb,
7 days: < 0.5 ppb
Span drift: 7 days: < 1 % of reading or 0.5 ppb whichever is greater
Response time: 15 seconds to 95 %
STP reference: 0 °C, 20 °C, 25 °C at 101.3 kPa
Sample flow rate: 600 cc/min (total for 2 channels)
Temperature range: 0 - 40 °C
Power: 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption: 265 VA (max at start-up)
190 VA (nominal)
Dimensions: 429 x 175 x 638 mm
Rack Spacing: 3.5 RU
Weight: 21.9 kg

Measurement Cell

Reaction Cell

Calibation Valve Manifold

Sample Filter Holder

Delay Loop

Ozone Generator

Dryer
Auxiliary Valve Manifold

NO2 to NO Converter

acoem.com | 3
Communication Data logging
•  #1 RS232 port (supports all protocols*) •   8 GB removable USB flash memory drive that
•  #2 RS232 port (supports all protocols* & stores the internal data logger, event log,
multidrop) automatic/manual configuration backup &
•  USB port (Advanced protocol only) automatic/manual parameter list save
•  Bluetooth (Advanced protocol only) •  Internal data logger (can log up to 12 of
•  TCP/IP network port (optional, supports all 200+ parameters)
protocols*). •  Logger interval (1 second to 24 hours)
•  Storage capacity ~ 10 years (set to 1 minute
* Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or Advanced
interval).

Communication analog & Options & accessories


digital I/O port
•  Internal Sample Dryer
•  3 x analog outputs (current or voltage), •  TCP/IP Network Port
12 bit resolution user definable range •  Bluetooth
(between two user specified points) •  Dual Sample (particulate) Filter
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA •  High Pressure Span (for direct cylinder calibration)
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset •  High Pressure Zero (for direct cylinder calibration)
of 0 V, 0.25 V or 0.5 V) •  Test Lamp (for PMT diagnostics)
•  3 x analog inputs (scalable), 0 - 5 V, •  Metric Fitting Kit (to connect 6 mm tube to
16 bit resolution rear ports)
•  8 x logic level digital control inputs •  19” Rack Mount Kit
•  8 x open collector digital status outputs. •  External Pump (240 or 110 VAC)
•  External Charcoal Scrubber
•  Annual Maintenance Kit
•  High Level Option
•  Printed User Manual (a soft copy of the user
manual is supplied on USB with each analyser).

Specifications subject to change without notice. Images used are for illustrative purposes
only. All trademarks and registered trademarks are the property of their respective owners.

© 2022 Acoem and all related entities. All rights reserved. 20221214

acoem.com
Serinus 30 ®
Carbon Monoxide Analyser

The Acoem Serinus 30* carbon monoxide (CO)


analyser delivers precise and reliable performance
at excellent value.

It uses proven NDIR gas filter correlation technology


to measure CO in ambient air (LDL < 40 ppb, range
0 to 200 ppm).

* Acoem Serinus 30 formerly known as Ecotech Serinus 30.

acoem.com
Approvals
•   US EPA approval (RFCA–0509–174) •   French approval LSCQA

•   EN approval TÜV (0000040203-02) •   Ukraine approval (12/3/B/24/295-17)

•   Australian Standard (AS 3580.7.1-2011) •   Chinese Pattern Approval (JJF1364-2012)

•   Russian approval (56262-14) •   Korean approval NIER (AACMS-2017-02)

Benefits
The Serinus range of gas analysers have been •  Programming, viewing, downloading & emailing of
designed using our experience and knowledge data is made even simpler using optional Bluetooth
gained from operating large air quality monitoring connectivity combined with Serinus Remote
networks for more than 40 years. The result, Android App
instruments that integrate seamlessly into
•  Built-in digital display measuring values & having
continuous monitoring networks.
function of measuring values transferred to
•  Reliable performance complemented with a two graphical trend display
year warranty
•  Enhanced operator safety through the use of
•  Minimise time spent on site performing 12 VDC internal voltages
maintenance through superior remote instrument
•  Reduced cost of spare parts, accessories &
control, diagnostic viewing and calibration
consumable items through extensive use of
•  Comprehensive data logging and remote viewing of standard components across the Serinus gas
over 200 operational parameters analyser range

•  Versatile interfacing through RS232, USB, analog & •  Rack slide design makes accessing internal
digital I/O & optional TCP/IP & Bluetooth components & removing the analyser from a rack
cabinet easy
•  Easy setup through an intuitive menu system,
advanced GUI and a large alphanumeric keypad •  AQMS power usage can be reduced due to the
with tactile keys instrument’s low power demand & its ability to
operate over a wide temperature range.
•  Instant status indication via illuminated instrument
status light buttons on the front panel

•  Removable flash memory stores ~10 years of


data, including up to 12 individual parameters and
event logs. Operational parameters can also be
transferred to memory for easy retrieval

•  Latest firmware updates can easily be installed


using the USB flash memory drive

acoem.com | 2
Specifications
Range: 0 to 200 ppm (autoranging)
Concentration units: mg/m3, μg/m3, ng/m3, ppm, ppb or ppt
Noise: < 0.02 ppm or 0.2 % of concentration reading whichever is greater
Lower detectable limit: < 0.04 ppm
Linearity: < 1 % of full scale (0 - 50 ppm)
Precision: 0.1 ppm or 0.1 % of reading whichever is greater
Zero drift: 24 hours: < 0.1 ppm
7 days: < 0.1 ppm
Span drift: 7 days: < 0.5 % of reading or 0.1 ppm whichever is greater
Response time: 60 seconds to 95 %
STP reference: 0 °C, 20 °C, 25 °C at 101.3 kPa
Sample flow rate: 1000 cc/min
Temperature range: 0 to 40 °C
Power: 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption: 260 VA (max at start-up)
150 VA (nominal)
Dimensions: 429 x 175 x 638 mm
Rack Spacing: 3.5 RU
Weight: 17.8 kg

DFU

CO-CO2 Converter

Calibration Valve Manifold

Sample Filter Holder

Detector Assembly

Source Timing Assembly

Measurement Cell

acoem.com | 3
Communication Data logging
•  #1 RS232 port (supports all protocols*) •  8 GB removable USB flash memory drive that
•  #2 RS232 port (supports all protocols* stores the internal data logger, event log,
and multidrop) automatic/manual configuration backup and
•  USB port (Advanced protocol only) automatic/manual parameter list save
•  Bluetooth (Advanced protocol only) •  Internal data logger (can log up to 12 of 200+
•  TCP/IP network port (optional, supports parameters)
all protocols*). •  Logger interval (1 second to 24 hours)
•  Storage capacity ~10 years (set to 1 minute
* Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or Advanced
interval).

Communication analog & Options & accessories


digital I/O port: •  TCP/IP Network Port
•  3 x analog outputs (current or voltage), 12 bit •  Bluetooth
resolution user definable range (between two user •  Dual Sample (particulate) Filter
specified points) •  High Pressure Span (for direct cylinder calibration)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA •  High Pressure Zero (for direct cylinder calibration)
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of •  Internal DC Pump (long life, low power, minimal
0 V, 0.25 V or 0.5 V) maintenance)
•  3 x analog inputs (scalable), 0 - 5 V, 16 bit •  Integrated CO2 Sensor (range: 0 - 2000 ppm,
resolution accuracy: ± 2 %)
•  8 x logic level digital control inputs •  Metric Fitting Kit (to connect 6 mm tube to
•  8 x open collector digital status outputs. rear ports)
•  19” Rack Mount Kit
•  External Pump (240 or 110 VAC)
•  Annual Maintenance Kit
•  Printed User Manual (a soft copy of the user
manual is supplied on USB with each analyser).

Specifications subject to change without notice. Images used are for illustrative purposes
only. All trademarks and registered trademarks are the property of their respective owners.

© 2022 Acoem and all related entities. All rights reserved. 20221005

acoem.com
Serinus® 31 B EN EF I T S
The Serinus range of analysers has been designed using our

Carbon Dioxide Analyser experience and knowledge gained from operating large air
quality monitoring networks for nearly 50 years. The result
is instruments that integrate seamlessly into continuous
monitoring networks.

• Guaranteed performance with a 2 year warranty


• Superior remote instrument control, diagnostic viewing &
calibration minimise on-site maintenance requirements
• Comprehensive data logging & remote viewing of over 200
operational parameters
• Versatile interfacing through RS232, USB, Bluetooth, analog &
digital I/O & optional TCP/IP
• Easier setup through an intuitive menu system with ‘Quick
Menu’, advanced GUI & a large keypad with tactile keys
• Instant display of operational status using illuminated traffic
lights on the front panel
• Removable flash memory stores 10 years of data, including
The Acoem Serinus 31 carbon dioxide (CO2) up to 12 individual parameters & event logs. Operational
parameters can also be transferred to memory for easy
analyser (previously known as the Ecotech retrieval
Serinus 31) uses non-dispersive infrared (IR) gas • Install latest firmware updates via the USB flash memory drive
correlation spectroscopy to provide accurate, • Easily program, view, download & email data using Bluetooth
stable & repeatable measurements of gaseous CO2. connectivity combined with the ‘Serinus Remote’ app from the
Google Play store
The Serinus 31 can be configured to operate in absolute or
differential mode providing flexibility within the analyser, • 12 VDC internal voltages for enhanced operator safety
making it well suited for ambient CO2 measurements in addition • Standard components across the Serinus range reduces the
to applications such as dilution extractive stack monitoring. cost of spare parts, accessories & consumables
• Rack slide design makes accessing internal components &
APPROV AL S removing the analyser from a rack cabinet easy
Based on the Serinus 30 which has the following approvals: • Choose either an external sample pump suitable for use by
multiple analysers or the optional low power internal pump for
• US EPA approval (RFCA–0509–174) greater sample versatility
• EN approval (TÜV 936/21221977/D) • Lower power demand & ability to operate over a wide
• Non Dispersive I.R. Spectrometry method EN1426 temperature range reduce AQMS power usage.
• Russian approval (56262-14)
• French approval LSCQA
• Ukraine approval (12/3/B/24/295-17)
• Chinese Pattern Approval (JJF1364-2012)
• Korean approval NIER (AACMS-2017-02)
S P ECI FICATIO N S I N P UT S & O UTP UT S
Range: 0 - 3000 ppm (autoranging) • 3 x analog outputs, menu selectable, current or voltage
Concentration display: User selectable mg/m , μg/m 3 3
• Menu selectable current output of 0 - 20 mA,
ppm & ppb 2 - 20 mA or 4 - 20 mA
Noise: 0.1 ppm • Voltage output of 0 - 5 V, with menu selectable zero offset
Lower detectable limit: 0.2 ppm (200 ppb), with Kalman of 0 V, 0.25 V or 0.5 V
filter active • Voltage output of 0 - 10 V configured using jumpers (JP3)
on rear panel PCA
Linearity: < 1 % of full scale
• Autoranging from 0 - 50 ppb to 0 - 3000 ppm
Precision: 0.2 ppm or 0.5 % of reading
(between 2 user specified full scale values)
whichever is greater
• 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution
Zero drift: 24 hours: < 1 ppm
Span drift: 7 days: < 0.5 % of reading or 1 ppm • 8 x logic level digital control inputs
whichever is greater • 8 x open collector digital status outputs.
Response time: 60 seconds to 95 %
STP reference: 0 °C, 20 °C, 25 °C at 101.3 kPa DATA LO GG I NG
Sample flow rate: 1000 cc/min Removable USB flash memory drive stores data in the
following formats:
Temperature range: 0 to 40 °C
• Instantaneous data from: 1, 3, 5, 10, 30 or 60 minute intervals
Power: 100 - 240 VAC, 50 - 60 Hz
& 2, 5, 10, 30 seconds
(autoranging)
• Average data from: 1, 3, 5, 10, 15, 30 minutes, 1, 4, 8, 12
Power consumption: 190 W max (typical at start-up)
or 24 hours
150 VA after warm-up
• Data storage of 10 years of 12 parameters, 1 minute data
Dimensions: 429 x 175 x 638 mm (W x H x L) on 8 GB memory.
Rack spacing: 4 RU
Weight: 21.3 kg O P TI O N S & AC CES S O R I ES
• Extended measurement ranges
C OM MU N ICATION
• External AC powered pump
• RS232 Port 1: Digital communication (capable of operating 3 analysers, excluding NOX)
• RS232 Port 2: Multidrop port • Internal long-life, low power maintenance-free pump
• USB port (digital communication) (Max 6 watts)
• Bluetooth (digital communication via Android app) • Dual filter (particulate)
• TCP/IP Ethernet network connection • High pressure zero/span valves
(optional) • Rack slides
• Protocols: Modbus RTU/TCP, Bayern-Hessen, • TCP/IP network port
EC9800, Advanced.
• Printed manual (electronic manual supplied)

CALIBRATION VALVE MANIFOLD

SAMPLE FILTER HOLDER

DETECTOR ASSEMBLY
SOURCE TIMING ASSEMBLY

MEASUREMENT CELL

SAMPLE DRYER ASSEMBLY

1492 Ferntree Gully Road Knoxfield VIC 3180 Melbourne Australia


+61 3 9730 7800 email@acoem.com acoem.com

Specifications subject to change without notice. All images used are for illustrative purposes only.
All trademarks and registered trademarks are the property of their respective owners.
© 2022 Acoem and all related entities. All rights reserved. 20220730
Serinus 10 ®
Ozone Analyser

The Serinus® 10* Ozone (O3) analyser delivers precise


and reliable performance at excellent value.

It uses proven non-dispersive ultraviolet (UV)


absorption technology to measure O3 in ambient air
(LDL < 0.5 ppb, range 0 to 20 ppm).

* Acoem Serinus 10 formerly known as Ecotech Serinus 10.

acoem.com
Approvals
•   US EPA approval (EQOA-0809-187) •   French approval LSCQA

•   EN approval TÜV (936/21221977/C) •   Ukraine approval (12/3/B/24/295-17)

•   Australian Standard (AS 3580.6.1-2011) •   Korean approval NIER (AACMS-2017-03)

•   Russian approval (56053-13)

Benefits
The Serinus range of analysers have been designed •  Latest firmware updates can easily be installed
using our experience & knowledge gained from using the USB flash memory drive
operating large air quality monitoring networks for •  Programming, viewing, downloading & emailing of
more than 45 years. The result, instruments that data is made even simpler using optional Bluetooth
integrate seamlessly into continuous monitoring connectivity combined with the Serinus Remote
networks. Android App
•  Reliable performance complemented with a two •  Built-in digital display measuring values & having
year warranty function of measuring values transferred to
•  Minimise time spent on site performing graphical trend display
maintenance through superior remote instrument •  Enhanced operator safety through the use of
control, diagnostic viewing & calibration 12 VDC internal voltages
•  Comprehensive data logging & remote viewing of •  Reduced cost of spare parts, accessories &
over 200 operational parameters consumable items through extensive use of
•  Versatile interfacing through RS232, analog & standard components across the
digital I/O & optional TCP/IP & Bluetooth Serinus range

•  Easy setup through an intuitive menu system, •  Rack slide design makes accessing internal
advanced GUI & a large alphanumeric keypad with components & removing the analyser from a rack
tactile keys cabinet easy

•  Instant status indication via illuminated instrument •  AQMS power usage can be reduced due to the
status light buttons on the front panel instrument’s low power demand & its ability to
operate over a wide temperature range.
•  Removable flash memory stores ~ 10 years of
data, including up to 12 individual parameters &
event logs. Operational parameters can also be
transferred to memory for easy retrieval

acoem.com | 2
Specifications
Range: 0 - 20 ppm (autoranging)
Concentration units: mg/m3, μg/m3, ng/m3, ppm, ppb or ppt
Noise: < 0.25 ppb
Lower detectable limit: < 0.5 ppb
Linearity: < 1 % of full scale
Precision: 0.5 ppb or 0.2 % of reading whichever is greater
Zero drift: 24 hours: < 0.3 ppb
7 days: < 0.3 ppb
Span drift: 7 days: < 0.5 % of reading or < 0.3 ppb whichever is greater
Response time: 30 seconds to 95 %
STP reference: 0 °C, 20 °C, 25 °C at 101.3 kPa
Sample flow rate: 500 cc/min
Temperature range: 0 - 40 °C
Power: 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption: 260 VA (max at start-up)
150 VA (nominal)
Dimensions: 429 x 175 x 638 mm
Rack spacing: 3.5 RU
Weight: 17.2 kg

Calibration Valve Manifold

Ozone Scrubber

Sample Filter Holder

Detector Assembly

Measurement Cell

Optical Bench

Lamp Driver

Measurement Lamp

acoem.com | 3
Communication Data logging
•  #1 RS232 port (supports all protocols*) •  8 GB removable USB flash memory drive that
•  #2 RS232 port (supports all protocols* & stores the internal data logger, event log,
multidrop) automatic/manual configuration backup &
•  USB port (Advanced protocol only) automatic/manual parameter list save
•  Bluetooth (Optional, Advanced protocol only) •  Internal data logger (can log up to 12 of
•  TCP/IP network port (optional, supports all 200+ parameters)
protocols*) •  Logger interval (1 second to 24 hours)
•  Storage capacity ~ 10 years
* Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or Advanced
(set to 1 minute interval)

Communication analog & Options & accessories


digital I/O port:
•  TCP/IP Network Port
•  3 x analog outputs (current or voltage), 12 bit •  Bluetooth
resolution user definable range (between two •  Dual Sample (particulate) Filter
user specified points) •  High Pressure Zero (for direct cylinder calibration)
Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA •  Internal Zero & Span (for instrument precision
Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of checks)
0 V, 0.25 V or 0.5 V) •  Internal DC Pump (long life, low power, minimal
•  3 x analog inputs (scalable), 0 - 5 V, maintenance)
16 bit resolution •  Metric Fitting Kit (to connect 6 mm tube to
•  8 x logic level digital control inputs rear ports)
•  8 x open collector digital status outputs •  19” Rack Mount Kit
•  External Pump (240 or 110 VAC)
•  Annual Maintenance Kit
•  Printed User Manual (a soft copy of the user
manual is supplied on USB with each analyser)

Specifications subject to change without notice. Images used are for illustrative purposes
only. All trademarks and registered trademarks are the property of their respective owners.

© 2023 Acoem and all related entities. All rights reserved. 20230728

acoem.com
Spirant TM
BAM
Particulate Monitor

The Spirant™ BAM automatically measures and


records airborne particulate concentrations using
the beta ray attenuation method.

It is designated by the US EPA as Federal Equivalent


Method for PM10 and PM2.5 monitoring.

* Acoem Serinus 30 formerly known as Ecotech Serinus 30.

acoem.com
Designations Operations
The Spirant™ BAM uses the beta ray attenuation
•   Spirant™ BAM 1000
method to measure particulate concentration.
PM10: FEM (EQPM-0798-122) AS/NZS
3580.9.11:2008
Every hour, a small 14C (carbon - 14) element emits
•   Spirant™ BAM 1100:
a constant source of high-energy electrons (known
PM2.5: Class III FEM, (EQPM-0308-170) AS/NZS
as beta rays) through a spot of clean filter tape.
3580.9.12:2013
These beta rays are detected and counted by a
sensitive scintillation detector to determine a zero
reading.

Features
The instrument automatically advances this spot of
•  Long term unattended remote operation of up to
tape to the sample nozzle, where a vacuum pump
60 days between site visits
then pulls a measured and controlled amount of
•  Concentration units: mg/m3, μg/m3 dust-laden air through the filter tape, loading it with
ambient dust.
•  Automatic hourly span checks

•  Fast and easy field audits using common audit


At the end of the hour, the dust laden spot is placed
tools
back between the beta source and the detector,
•  Rugged anodised aluminium, stainless steel, and thereby causing an attenuation of the beta ray
baked enamel construction signal. This is then used to determine the mass of

•  Highly accurate, reliable, and mechanically simple


particulate matter on the filter tape and volumetric
flow system
concentration of particulate matter in ambient air.
•  Hourly filter advances minimise effects on volatile
compounds
Measurement data, configuration files, error logs,
•  Real-time particulate monitoring option and flow statistics are stored in its internal data
logger and are available via RS232 using common
•  Advanced Smart Heater technology precisely
terminal programs and ECOTECH Airodis™ software.
controls sample relative humidity

•  Integrated datalogger allows the connection of up


Digital dataloggers may obtain data from the unit
to six additional meteorological sensors with 182
using serial port commands or by recording the
days of data storage.
automatic hourly serial output.

The Spirant™ BAM performs continuous user


selected evaluation of a variety of criteria for
data validation including flow statistics and a
comprehensive set of error codes such as power,
flow, hardware, tape, nozzle, beta count and span
check errors.

acoem.com
Specifications
Accuracy: Exceeds US EPA Class III PM2.5 FEM standards
for additive and multiplicative bias
Measurement resolution: 0.1 μg/m3
Display Resolution: 1 μg/m3
Detection limit: (2σ) 1 hr: < 4.8 µg/m3
(3.6 μg/m3 typical)
(2σ) 24 hr: < 1.0 µg/m3
Range: 1 mg (1000 μg) default setting.
Settable from 0.1 mg to 10 mg
Optional ranges: Available on request
Measurement cycle time: 1 hour
Flow rate: 16.7 litres/minute adjustable 0 - 20 LPM range actual or standardised flow
Filter tape: Continuous glass fiber filter tape
Span check: Automatic 0.800 mg (typical)
span foil, verified hourly
Beta source: 14C (carbon - 14), 60 µCi ± 15 µCi
(< 2.22 x 106 Beq), half-life 5730 years
Beta detector type: Photomultiplier tube with organic plastic scintillator
Operating temperature: 0 to + 50 °C
Ambient temperature: - 40 to + 55 °C (BX - 596 AT sensor)
- 30 to + 50 °C (BX - 592)
Extended range of sensors available
Ambient humidity: 0 - 90 % RH, noncondensing
Sample humidity control: Active Smart Heater module, 10 - 99 % RH setpoint
Sampling Head: Dynamic Heated Sampling head measurement of PM2.5
with adjustable temperature 20-70 Deg C
Power supply: 100 - 230 VAC, 50/60 Hz.
Factory configured
Power consumption: 110 V: 262 W max with Medo pump and inlet heater running
(642 W with Gast pump)
230 V: 312 W max with Medo pump and inlet heater running
(717 W with Gast pump)
Dimensions: Weight: 310 x 430 x 400 mm
24.5 kg without external accessories

acoem.com
Communication Options
User interface RTPM
•  Menu-driven interface, 8 line 40 character LCD •  Real-time particulate monitor provides one minute
display & keypad measurements
Analog output Aurora™ Interface
•  Isolated 0 - 1 VDC output standard •  Enables interfacing of Spirant™ with Aurora™ 2000
•  0-1 V, 0 - 10 V,2-20 mA 4 - 20 mA, 0 - 16 mA switch Nephelometer for one minute measurements
selectable (requires Aurora™ 2000 Integrating Nephelometer)
Serial interface Sample inlets
•  Multi Drop RS232 two-way serial port for PC or •  PM10, PM2.5 & TSP available
modem communications
•  USB Port/TCP/IP, Ethernet
Printer output
•  Output only serial port for data or diagnostic
output to a PC or serial printer
Telemetry inputs
•  Clock reset (voltage or contact closure), telemeter
fault (contact closure)
Alarm contact closures
•  Data error, tape fault, flow error, power failure,
maintenance
Error reporting
•  User-configurable available through serial port,
display, and relay outputs
Memory
•  4369 records (182 days at 1 record/hr)

Specifications subject to change without notice. Images used are for illustrative purposes
only. All trademarks and registered trademarks are the property of their respective owners.

© 2022 Acoem and all related entities. All rights reserved. 20230208
ACOEM Ecotech Industries Private Limited
Plot no 57, Sector II, Pithampur Industrial Area, Dhar, Madhya Pradesh, 454775. INDIA acoem.com
Serinus 44 ®
Ammonia Analyser
NO, NO2, NOx, NH3 Analyser

The Acoem Serinus 44* analyser delivers precise and


reliable performance at excellent value.

It uses proven chemiluminescence technology and


an external thermal catalytic converter to measure
NO, NO2, NOX and NH3 in ambient air.

* Acoem Serinus 44 formerly known as Ecotech Serinus 44.

acoem.com
Approvals
•   US EPA approval (RFNA–0809–186)

Based on the Serinus 40 which has the following approvals:

•   EN approval TÜV (0000040204 -02) •   Ukraine approval (12/3/B/24/295-17)

•   Australian Standard (AS 3580.5.1-2011) •   Chinese Pattern Approval (JJF1361-2012)

•   Russian approval (56263-14) •   Korean approval NIER (AACMS-2017-01)

•   French approval LSCQA

Benefits
The Serinus range of analysers have been designed •  Removable flash memory stores ~10 years of
using our experience & knowledge gained from data, including up to 12 individual parameters &
operating large air quality monitoring networks for event logs. Operational parameters can also be
more than 45 years. The result, instruments that transferred to memory for easy retrieval
integrate seamlessly into continuous monitoring
networks. •  Latest firmware updates can easily be installed
using the USB flash memory drive
•  Guaranteed performance with a two year warranty
•  Programming, viewing, downloading & emailing
•  Minimise time spent on site performing
of data is made even simpler using Bluetooth
maintenance through superior remote instrument
connectivity combined with the Serinus Remote
control, diagnostic viewing & calibration
Android App
•  Comprehensive data logging & remote viewing of
over 200 operational parameters •  Enhanced operator safety through the use of
12 VDC internal voltages
•  Versatile interfacing through RS232, analog &
digital I/O & optional TCP/IP & Bluetooth •  Reduced cost of spare parts, accessories &
consumable items through extensive use of
•  Easier setup through an intuitive menu system with
standard components across the Serinus range
“Quick Menu”, advanced GUI & a large keypad with
tactile keys •  Rack slide design makes accessing internal

•  Instant display of operational status using components & removing the analyser from

illuminated traffic lights on the front panel a rack cabinet easy.

acoem.com | 2
Specifications
Range: 0 - 20 ppm (autoranging)
(analog ranges 0 - 50 ppb to 0 - 20 ppm)
(NH3 range dictated by external converter; usually ~2 ppm)
Concentration display: User selectable mg/m³, μg/m³, ppm, ppb or ppt
Noise: < 0.2 ppb
Lower detectable limit: < 0.4 ppb or 0.5 % of reading whichever is greater
Linearity: < 1 % of full scale
Precision: 0.4 ppb or 0.5 % of reading whichever is greater
Zero drift: 24 hours: < 0.4 ppb
7 days: < 0.4 ppb
Span drift: 7 days: < 1 % of reading or 0.4 ppb whichever is greater
STP reference: 0 °C, 20 °C, 25 °C at 101.3 kPa
Sample flow rate: 900 cc/min (total for 3 channels)
Temperature range: 0 - 40 °C
Power: 100 - 240 VAC, 50 - 60 Hz (autoranging)
Power consumption: 265 VA (max at start-up)
190 VA (after warm-up)
Dimensions: 429 x 175 x 638 mm
Rack spacing: 3.5 RU
Weight: 21.85 kg

acoem.com | 3
Communication Data logging
•  USB port (digital communication) Removable USB flash memory that stores data in
•  Bluetooth (digital communication via Android App) the following formats:
•  TCP/IP Ethernet network connection (optional) •  Instantaneous data from 1, 3, 5, 10, 30, or 60
•  RS232 Port 1: Digital communication minute intervals
•  RS232 Port 2: Multidrop port •  Average data from 1, 3, 5, 10, 15, 30 minutes,
•  Modbus RTU/TCP protocol, advanced 1, 4, 8, 12, or 24 hours
•  25 pin I/O port (analog outputs, analog inputs, •  Data storage of 10 years of 12 parameters,
digital status inputs, digital status outputs). 1 minute data on 8 GB memory.

Inputs / outputs Options & accessories


•  25 pin I/O port •  HTO-1000N NH3 converter
•  Menu selectable current or voltage output 0 - 20 •  External AC powered pump
mA, 4 - 20 mA or 0 - 5 VDC (opt 0 - 10 VDC) •  TCP/IP network port
•  Menu selectable offset of 0, 5 or 10 % •  Bluetooth
•  Autoranging from 0 - 50 ppb to 0 - 20 ppm •  Rack slide kit
(between 2 user specified full scale values) •  Dual filter (particulate)
•  3 scalable analog inputs, 0 - 5 V, 160 μV resolution •  High pressure zero/span valves
•  8 logic level inputs/8 open collector outputs. •  Printed manual - electronic manual supplied
with analyser.

Specifications subject to change without notice. Images used are for illustrative purposes
only. All trademarks and registered trademarks are the property of their respective owners.

© 2022 Acoem and all related entities. All rights reserved. 20221216

acoem.com
TSP A73 / TSP A74 / TSP A76
Experts in gaz analysis

Gas Analyser GC866


z ene
Ben airTOXICBTX PID
a GC/PID for automatic monitoring of BTEX.
In air, water or soils

u ene
T ol Approved and installed by National US EPA*

z ene
lb en
Ethy

es
(m,p)
en
Xy l

Model A73022
s (o)
ene
Xyl Environment:

BTEX: 5 or 7 compounds
In non urban area 0.032 to 32.5 µg/m3 0-10 PPB
In urban area 0.32 to 325 µg/m3 0-100 PPB
In Fence line refinery 3.25 to 3250 µg/m3 = 0-1 PPM
e
xan
Indoor air

o h e Outdoor air
C ycl
BTEX + CALIB standard +(Styrene + cyclohexane)= A73022
BTEX (without calib) = A74022
BTEX + 1,3 -butadiene = A76022

Compliant with EN 14662: No interferences with BENZENE


ene
Styr Pattern Approval Certificate of the Measuring Instruments of PR China

Process:
Industrial Hygiene
Fence line

d i ene
ta
-
Option Purge & Trap (method 502-2) for water quality surveillance
3 bu A76022
1, Opti
:
on

* U.S Environmental Protection Agency: www.epa.gov

WWW.CHROMATOTEC.COM
airTOXICBTX PID
a GC/PID for automatic monitoring of BTEX.
In air, water or soils
Technical specifications
Principle of the airTOXICPID BTEX analysis: up to 8 compounds
- Benzene
• This instrument uses a port valve with a single absorbent trap, and a
- Toluene
30 meter metallic 0.28 mm ID column.
- Ethylbenzene
• Minimum detection level as low as 10 ppt for Benzene or 1.3.Butadiene - Xylenes : Ortho, meta, para
(A76022) in ambient air. - Butadiene (model A76022)
- Cyclohexane
• Miniaturization, sensitivity, mobility and flexibility are its main features. - Styrene
Everything from the sample port up to the data storage is integrated in a Lower detection limit (LDL) in automatic mode :
19"-rack 5U.
≤ 0.01 ppb = 0.0325 µg/m3
Detection range and linearity: BENZENE
• Programmed gradient temperature up to 202°c for the column oven
and pressure/flow control of the carrier gas . 3.25 to 3250 µg/m3 = 0-1000 ppb
0.32 to 325 µg/m3 = 0-100 ppb
• Linearity on area with R2 > 0.995 0.032 to 32.5 µg/m3 =0-10 ppb
European range : 0,45 to 45 µg/m3 =0.1 to 14.5 ppb Relative standard variation : PRECISION
Better than 0.3 % over 48h (Retention Time)
• Before delivery the analyser is tested for one week by our Better than 2 % over 48 h on 1 ppb (Concentration)
quality control department. Results on LCD :
- Data storage
• Photo ionisation detector (PID), 10,6 eV lamp.
- 4 or 8 x 4-20 mA or 0/10 V output in option
• Self-cleaning of the lamp for high stability - MODBUS RTU / JBUS or Bayern Hessen protocol .
Cycle time:
• Bi-directionnal RS-232 C to transfer data and results to the internal 15 or 20 or 30 min
computer. Gas supply:
Nitrogen: 4 ml/min (inlet 3 bars; 1/8’’ swagelok)
• Vistachrom software enables the user to view and store data on a indus- Air or nitrogen for CALIB: 50 ml/min continuously
trial computer. It provides comfortable user friendly utilities to recalculate, and 180 ml/min in CALIB method
calibrate and export data and to configure the measurement.
Detector cleaning : 3 ml/min
15ml/min , Sample inlet (vacuum pump) ¼’’swagelok,
• The software allows the calculation of retention time, area, mass or
concentration profiles, in any measuring unit. Sample volume:
20 to 400 ml or more (programmable)
• CALIB standard in A73022 / Flow=50ml/min N2 or air Operation Temperature:
continuously and 180 ml/min for 6 minutes in calibration method (one per Room with air conditioning: 10 to 35°c
day) Computerized Electronic
CPU: Pentium III
• Valve for external gas cylinder calibration in A74022
4xUSB Connecting Port
• LCD DISPLAY
• Digital output: communication protocol. Two RS-232 ports
Display: 10’’ TFT Color LCD
Legally authorized software: Windows XP embeded
Theory Power supply:
- main 230V 50Hz or 115V 60 Hz
- battery 24V (option)
Photoionization is initiated by the absorption of short wavelength ultravio-
Electrical consumption:
let light by a molecule. This can lead to ionization as follows:
Average 150 VA, Peak 360 VA
R + hv => R+ + e-
Dimensions:
If the ionization potential of R is less than or equal to the energy of the Rack 482 mm (19")Height 222 mm (5U), depth 600 mm
photon, hv, then the species are ionized Weight:
The sensor consists of a sealed interchangeable ultraviolet lamp that emits a 18 kg =analyser ( 37 kg with packaging )
selected energy line.
Lamps with energies of 8.3, 9.5, 10.6 and 11.7 eV are available.
Part information : Model
PID is linear.

BTEX + CALIB standard +(Styrène + cyclohéxane) A7302


Options BTEX (without calib) A74022
BTEX + 1.3 butadiène A76022
• MODBUS RTU
• CALIB for A74022 To contact us : info@chromatotec.com
• Automatic validation and autocalibration
• Nitrogen generator up to 200 ml/min AMERICA EUROPE Asia
• Modem support and remote control CHROMATOTEC Inc. AIRMOTEC ag SA Room 1301, Building 8,
• 4 or 8 Analog outputs 4-20 mA or 0-10 V. 1833 Egret Bay Blvd, Suite 270, 15 rue d’Artiguelongue Tianshuixiyuan Chaoyang
1.3.Butadiene ( A76022 ) HOUSTON TX 77058 - USA 33240 Saint Antoine FRANCE District 100026 Beijing, China
Phone: + (281) 335 4944 Tél: +33 (0)557 940 626 Ph: +86 10 85 96 76 59
Due to Chromatotec’s continuing program of product improvements, Fax: +1 (281) 335 4944 Fax: +33 (0)557 940 620 Fax: +86 10 85 96 55 35
specifications are subject to change without notice.

WWW.CHROMATOTEC.COM
AM-5800 Dynamic Dilution Calibrator
Overview
Based on microprocessor technology, the Dynamic Dilution Calibrator is developed for calibrating the gas analyzer and it
supports multi-path calibration. Equipped with high-accuracy mass flow controller and standard gas, this system can
provide calibration gas for zero point and span inspection of multiple gas components such as O 3 , NO, NO 2 , CO, SO 2 ,
Benzene, Toulene, Ethyl benzene, Xylene etc. Upto 4 gas sources can be provided.
Built-in programmable ozone generator is available optionally with the dynamic dilution calibrator. It can be used to calibrate
O 3 accurately and reliably. Also it can be used in GPT to produce NO 2 . Linear drive of multi-point section is adopted for ozone
generator to ensure the repeatability and accuracy of O 3 concentration; optional photometer can improve high-level of
accuracy control for ozone generator. Instrument is designed for fast response, high repeatability, high accuracy and ease of
operation. Using the ozone generator, quality control of lab & gas analyzer can be ensured.

Features
R Continuous self-checking with alarm function R High precise mass flow controller
R Bidirection RS232 port for remote control R Large dilution ratio and fast response
R Digital output working parameter R Quartz GPT chamber, multi interfaces for calibration gas
R USB and Ethernet interface R Ozone generator and ozone photometer are optional
R Colorful display and screen touch operation R Multi-functional operation by microprocessor
R Large memory and history data saved automatically R Task software is allowed to monitor test data in operation

Specifications
Item Parameter Specifications
Flow range of diluent gas (0~5) SLPM, (0~10) SLPM, (0~20) SLPM optional
Flow range of standard gas (0~50) sccm, (0~100)sccm, (0~200) sccmoptional
Accuracy of flow control ± 1%F.S.
Linearity ± 0.5%F.S.
Repeatability of flow control ± 0.2%F.S.

Dilution system Requirement of zero gas 10SLPM@30psi


Standard gas inlet 4
Diluent gas inlet 1
Response time T98<60 s
Max. output 6 μmol/mol(ppm)
Ozone generator Min. output 100 nmol/mol(ppb)
(Optional) Stability ±1%/7 days
Response time T98<180 s
Range (0.1~10) μmol/mol(ppm)
Response time 1.0 nmol/mol(ppb)
Linearity 1%F.S.
Ozone photometer Up-down time <20 s
(Optional) Response time 180 s(98%)
Zero drift <1.0 nmol/mol(ppb)/7days
Span drift <2%/7 days
Sample gas flow 800 sccm
Volume Size 107cm3
Inside Chamber diameter 3.20cm
Glass Oven
Usable length 13.4cm

Permeation Oven Operating Range 2~60 o C


Option Volume Size 123.6cm3
Teflon Coated Inside chamber diameter 3.09cm
Oven Usable Length 12.7cm
Operating Range 2~60 o C
Power supply 200~240V, 50/60 Hz, 200W
Dimensions(H×W×D) 178 mm×432 mm×600 mm
Weight <15 kg
Whole System Working temperature (5~40) ℃
Working humidity (0~95)% RH
I/O method RS232, RS485 and Ethernet (optional)
Protocol Modbus

SWAN TECHNICAL SERVICES PVT.LTD.


Plot No: 922 & 935, Swami Ayyappa Co-op Society, Madhapur, Hyderabad, Telangana - 500081
Mob: 9642225204 ; Tel: (040) 40216184/85 ; Fax: (040) 40216183
Email: info@swanenviron.com ; Website: www.swanenviron.com
Regional Offices: Ahmedabad, Bengaluru, Bhubaneswar, Chandigarh, Chennai,
Delhi, Guwahati, Indore, Kolkata, Mumbai, Raipur & Visakhapatnam
WIND SPEED SENSOR MODEL - DWA 8600M.
Wind speed Sensor : 3 Cup Anemometer.
Sensing : 3 cup assembly mounted on friction free shaft and
coupled to a chopper.
Starting threshold : 0.2 meters/sec .
Range : 0 to 70 meters/sec .
Operating temp : -50 Degrees C to +65 Degrees C **
Output : TTL pulses output proportional to wind speed
. Built in line driver to drive long cable > 50 ohms
loop resistance. (Optional output 0-1V or 0-5V full scale)
Accuracy : +/- 1% of full scale
Diameter of cup : 50 mm.
Diameter of cup assembly : 165 mm.
Construction of sensor body : Brass housing and stainless steel shaft .
PRINCIPLE OF OPERATION:
DYNALAB anemometer is a fast response, low threshold opto electronic anemometer. When rotated by wind, a
chopper on the anemometer shaft interrupts an infra red light source , generating pulses from a photo transistor.
The signal is amplified and fed through a line driver . The frequency is proportional to wind speed. The
anemometer comes with 10 meters of shielded cable.

SUITABLE MOUNTING ASSEMBLY PROVIDED


** SUITABLE HEATING ARRANGEMENT REQUIRED FOR SENSOR TO OPERATE
FROM -50 DEGREES C TO +65 DEGREES C ( EXTERNAL 24 V/50AH POWER FOR HEATER TO BE PROVIDED BY USER)
WIND DIRECTION SENSOR MODEL -DWD 8601M.
Wind Direction Sensor : Wind Vane.
Sensing : Vane coupled to linear endless potentiometer.
Starting threshold : Better than 0.5 meters/sec.
Range : 0 – 359 degrees (360 degrees)
Output : 0 to 5 kilo-ohm resistance ( 0 to 359 degrees).
: (Optional 0 –1V 0r 0 – 5V please specify)
Resolution : 1 degree.
Accuracy : +/- 3 degrees.
Operating Temperature : -40 to + 60 degree Celsius
Construction of sensor body : Brass housing, stainless steel shaft and aluminum vane
PRINCIPLE OF OPERATION:
DWD 8601 wind vane is a counter balanced, low threshold wind vane. A Linear, wire wound endless potentiometer
is coupled to the vane by an SS shaft. As the vane turns, it rotates a stainless steel shaft which is coupled to the
potentiometer. This potentiometer has excellent linearity, very low starting torque.
The north of the wind vane is marked on its body. This line is to be aligned with actual North with the help of a
prismatic compass, at the time of installation. Sensor gives minimum resistance at North (i.e., 0 degree
approximately 20 ohms ). The resistance output is linearly proportional to the position of the wind vane

Ordering information :
Dynalab Wind Vane DWD 8601MX
B --- Brass epoxy coated body
A --- Aluminum epoxy coated body
S --- SS 316 body
AIR TEMPERATURE SENSOR MODEL -DWT 8102
Sensing : Standard Platinum RTD element PT1000,
mounted inside a weather shield
Range : - 40 degrees to + 60 degrees Celsius.
Resolution : 0.1 degrees Celsius.
Accuracy : + 0.2 degrees Celsius.
Output : Resistance
Weather Shield : ABS plastic molded Non Aspirated weather shield coated
with weather proof reflective white paint.
Size of body : 200(H) x 150 mm diameter(with weather shield).
Housing : Sensor mounted in a slotted tube on a Brass stem
Inside a weathershield. The sensor is supplied with
10 Meters shielded cable
Power requirement : 5V
PRINCIPLE OF OPERATION :
The sensor used for measurement is an RTD ( PT 1000). Here the resistance of the element varies with
temperature (increases with temperature), approximately 3.9 ohms/degree Celsius. The weather shield Is
provided to avoid direct heating of the sensor by sun’s radiation and to protect it from rain and snow.

Ordering Information :
Dynalab Temp Sensor with Shield DWT8102X

Brass Epoxy coated stem B


SS316 Stem S
HUMIDITY SENSOR MODEL DTH8103
Sensing : Solid state capacity type sensor.
Resolution : 0.1 %.
Range : 0 to 100 % operating at -40 C to +50 C
Accuracy : ± 3% of full scale reading.
Response time : 50 sec to 1 Min
Operating Temperature : -40 o C to +50 o C.
Power requirement : + 7 to 12 volts DC.
Power consumption : ~ 4 mA.
Output : 0- 1V for 0 to 100% humidity
Weather Shield (optional) : Non AspiratedABS plastic molded weather shield with weather proof
reflective white paint coating.
Size of body :200(H) x 150 mm diameter. (with weather shield)
PRINCIPLE OF OPERATION:
Humidity sensor features an improved design to provide highly accurate and rapid measurements. The
humidity sensor is a thin film capacitor element. A dielectric polymer absorbs water molecules from the air
through a thin metal electrode and this causes a capacitance change proportional to humidity. The response is
essentially linear. A sintered filter is provided to protect the sensor element from dirt, atmospheric pollutant
and water condensation.A solid state electronic circuit is built in each probe to produce 0 to 1000 M.Volts
output signal corresponding to relative humidity value 0 to 100 %. The output is single ended.
Ordering Information:
Dynalab Humidity Sensor with Shield DTH 8103 X
B—Brass Epoxy coated Stem
S SS 316 Stem
SOLAR RADIATION SENSOR MODEL - DWR 8101.
Sensor : 72 element thermopile.
Spectral range : 0.3 to 3 µ meters (300 to 3000 nm)
Sensitivity : 15- 20 micro volts/W/M ².
Time constant : < 25 seconds.
Range : 0 – 2000 W/ Sq.m
Output : 15 to 25 millivolts Fullscale
Calibration factor : 15 to 20 micro Volts/Watt/Sq.Meter
Accuracy : +3%
Stability : 1 % per year
Operating temperature : -10 to 80 deg C
Zero offset : < 7W/Sq.M
Field of view : 180 degrees
Dynalab Solar radiation sensor DWR 8101 is class II pyranometer as per WMO specifications
PRINCIPLE OF OPERATION:
The pyranometer measures radiation received on a horizontal surface from both the sun and the sky. When
exposed to radiation, the temperature of the blackened horizontal surface rises. The equilibrium temperature
reached by this blackened surface is a measure of the radiation. This temperature is measured by a thermopile.
A thin metallic film blackened with a special paint (which is the sensor. A multi element copper constantan
thermopile is in thermal contact with this thin metal film. Alternate junctions of this thermopile are in thermal
contact with the massive body of the instrument at ambient temperature which serves as the cold junction. This
way a millivolt output proportional to the radiation received develops across the thermopile. the instrument has
a time constant less than 25 seconds.The Pyranometer is calibrated against a secondary standard whose
accuracy can be traced to international standards

Ordering information : Dynalab Pyranometer model DWR 8101


DYNALAB WEATHERTECH RAINFALL SENSOR MODEL NO.DTR8104

Sensor : Tipping bucket rain gauge.


Sensing : Magnet and reed switch (on-off output).
Resolution : 0.2 mm or 0.5 mm per tilt
Accuracy : + 2%
Operating Temperature : -40 o C to +60 o C. (heater required for –ve temperatures)
Rim diameter : 203 mm.
Collecting area : 325 mm².
Material : Raingauge shell made of FRP. Bucket and mounting
made of stainless steel SS316
Capacity : Unlimited.
Sensitivity : 0.5 mm or, 0.2 mm (rainfall per pulse)
PRINCIPLE OF OPERATION:
It uses a tipping bucket mechanism to produce a contact closure every time it receives a predetermined
quantity of rainfall . The body and funnel are made of FRP (Fiber glass Reinforced Plastic), rim is made of gun
metal. All parts having contact with water are made of stainless steel. Each tip of the bucket produces an on-off
output when the magnet passes over the reed switch.
Optional heater can be provided for operation below freezing point.

Ordering Information Dynalab Tipping Bucket Raingauge : Model DTR 8104X


0 to 70 ° C : O
-40 to 70 ° C : H
DATALOGGER DWL 1002
DWL 1002 is Microprocessor based Weather Monitoring System with built-in clock and Calendar.
Power requirement : 12V DC.
Outputs : One parallel port for connecting a memory module or 80
Column Dot Matrix Printer (Centronics comptible).
One serial port for serial data transfer (RS 232)
One Alphanumeric two line Liquid Crystal Display for
indicating real time data and time & Calendar.

Keyboard : 20 Key keyboard for setting clock, calendar, averaging


interval and Manual operation.

Input Channels : 1,2.4,8,16, 24 or as specified by customer


Analog Digital conversion : 12 bit double slope ADC
Mechanical dimensions : 250 mm(L) X 80mm (W) X 180 mm (H)
Built in signal conditioners for Dynalab Sensors.
Features :
* Very low power consumption using CMOS IC’s
* Long battery back-up time (works for approximately 7 days on 12V,7 AH battery).
* Minimum power up programming
* Built-in sensor interface
* Atmospheric discharge transient protection provided.
 20 Key, membrane type keyboard for easy programming and setting.

Optional : Table top model
The Datalogger samples sensor data every 5 seconds(other sampling times possible) and
stores the same in the Datalogger. The same is averaged over a preset interval ( set from keyboard from 1
Min to 60 Min or more). This data can be downloaded from the Datalogger through the serial port provided.
It is possible top connect a radio modem
or a normal telephone modem to the serial port. The data can be downloaded to a PC at the base station by
sending message with an address.
The data also can be stored in a memory module (min 256 K battery backed) through the
parallel port. The transmitted data can be directly imported in to an Excel file.
The sensors are mounted on a mast as per the requirement of the user. We provide cross arms for mounting
the sensors.
The Datalogger and the modem , memory module and the battery (12 V 7,5 AH MF)
can be mounted inside a weather proof enclosure .
A solar cell charger can be provided for the system so that the system can work unattended.
NetBox
The NetBox is a dual chain outdoor AP/CPE/Point-to-Point device with
RP-SMA connectors for antennas, and a cable hood for protection against
moisture. This device supports the new 802.11ac standard for increased
wireless speed (866Mbit datarate, and 20/40/80MHz channels).

The case can be opened with one hand, and is protected against the
elements. Ethernet and a Grounding wire exits are provided on the bottom,
behind a protective door.

Comes with a mounting loop for tower/pole mounting, and a separate DIN
rail mount is also provided. Package also includes a PoE injector and power
supply unit.

Order code RB911G-5HPacD


CPU QCA9557 720MHz network processor
Memory 128MB DDR onboard memory
Ethernet One Gigabit port with Auto-MDI/X
Wireless QCA9882 5GHz 802.11ac, 2x RP-SMA connectors, Dual chain
Connector type RP-SMA Female (outside thread)
Extras beeper, signal and status LEDs, voltage and temperature sensors
Supported
20/40/80MHz
channels
Power options PoE: 8-30V DC on Ether1 (Non 802.3af). Consumption: 12W at 24V
Dimensions 246x135x50mm; Weight: 390g
OS MikroTik RouterOS, Level4 license
Kit includes Netbox outdoor unit, PoE injector, mounting loop, DIN rail mount, monting ring

Wireless transmit/receive specifications


TX/RX at MCS0 30dBm / -96dBm
TX/RX at MCS7 27dBm / -77dBm
Metal ring
TX/RX at MCS9 22dBm / -72dBm
TX/RX at 6Mbit 31dBm / -96dBm
TX/RX at 54Mbit 27dBm / -81dBm
Frequency range 4920-6100 MHz, Operating range limited by Country Regulations

Gigabit PoE injector DIN mount

Using the optionally available Flexguide cable, you


can use the NetBox with any 3rd party antenna

NetBox
mANT30 series
mANT30 is a professional class 5 GHz 30dBi dish antenna, built to the highest industry
standards. Built to seamlessly accomodate our Basebox series products, but can be used for
any pole mounted wireless device due to the adequate length of the included FlexGuide cable.

Two antennas are available, with a standard type mount (MTAD-5G-30D3), and with a
precision alignment mount (MTAD-5G-30D3-PA). The antennas come packaged with all
necessary accessories and cables.

Electrical Specifications
Frequency Range 4.7-5.875 GHz Horizontal polarization
Gain 30 dBi typically
MTAD-5G-30D3 Polarization Dual (Vertical and Horizontal)
(With standard type mount) 3dB Beamwidth +/-2.5 deg
Standards Complies with EN 302 326 DN1, DN2, DN3, DN5
VSWR ≤ 1.4 typ, ≤ 1.8 max
Port to Port Isolation >40dB min
Front-to-Back Ratio >30 dB
Cross Polarization >40 dB
Power Rating 100 watts
Impedance 50 ohms
+/- 20 deg (MTAD-5G-30D3),
Elevation adjustment range
+/- 15 deg (MTAD-5G-30D-PA)

Physical/Environmental Specifications
Diameter x Depth 70 x 45cm (27.5 x 17.8in)
5.7kg (12.6 lbs) PA and 4.8kg (10.7 lbs)
Weight neto
standard version
Reflector Aluminum
Outdoor Rating ETSI EN 300 019-2-4
Wind Survivability 201kph (125mph)
Vertical polarization
Wind Load (125 mph) 181.4kg (400 lbs)
Operating Temperature -50°C to 80°C(-49°F to 158°F)
(MTAD-5G-30D3): 3 to 7cm (1.2 to 2.75in)
FlexGuide Pole Mount Diameter Range
(MTAD-5G-30D-PA): 3 to 10cm (1.2 to 3.9in)
Connector (2) RP-SMA Female (outside thread)
Packaged size 73x73x20cm (29x29x8in)
(MTAD-5G-30D3): 7.5 kg (16.5 lbs),
Packaged weight
(MTAD-5G-30D3-PA): 8.4 kg (18,5)
Can directly mount Basebox and other future
Compatible with RouterBOARD devices, or accept any pole-
mounted device
FlexGuide RPSMA RF Cables (RP-SMA-male
to RP-SMA-male) x 2pcs; Bracket for mounting
MTAD-5G-30D3-PA BASEBOX series radio; Self-Bonding Tape for
(With precision alignment mount) Package includes
insulating the RF cables x 2 slices; Precise
alignment mechanisms
(PA Version only)
Note: Basebox radio not included, available separately.

mANT30
13th MAR 2024,
Our Ref: SBA-JC/SEPL/UPS SALE-EMERSON-VERTIV/181/2023-24

To,
M/s. Swan Environmental Pvt Ltd,
Plot No: 922 & 935, SACS,
Madhapur, Hyderabad. TS.

BATTERY CALUCULATION

UPS KVA * POWER FACTOR OF UPS


END BATT VOLTAGE * NUMB OF BATTERIES

FOR 3KVA UPS(3KVA/192VDC)-16 BATTERIES

Now This model is not available

1) 3000 *0.8 = 2400 = 14.28 * 6 hrs = 85.68AH or 100AH (6 HR Backup)


10.5 * 16 168

************************************************************************************

So we are suggesting below


2) 3000 *0.8 = 2400 = 22.85 *10%= 25.13* 6 hrs = 150.811AH or 200AH (6 HR Backup)
10.5 * 10 105

3KVA/200AH-10 BATTERIES AC room controlled temperature is recommended as 25 Deg.C for UPS batteries.

We hope above are in line with your requirements and please don’t hesitate to contact us for any
further clarifications pls feel free to contact on 9849750976, vsrishylam@sbatechnologies.co.in,

Note: Happy to Announce Our New Service Station Opened at Ayyappa Society,
Madhapur, Hyd.

Thanking you and looking forward for your positive response.


Yours cordially,

For SBA TECHNOLOGIES.

Raju
Support In Sales
Mobile No: 7680099302

You might also like