SCS50
SCS50
Main Bearing
Gas Chamber
Bladder Accumulator
Outer Body
Pressure Chamber
Metering Orifices
Issue 4.2003 Specifications subject to change
140 20 Stroke 20
B Stroke
Hub B Hub
180 Amax Amax
∅ 22 35 35
72
62 72 40 Stroke 20
Hub
17,5
190 D Emax
225 Amax
Technical Data
Impact velocity range v: 0.6 to 4.6 m/s. In creep speed: The shock absorber can be pushed
Reaction force Q: At max. capacity rating = 160 kN max. through its stroke.
Energy capacity W3: At max side load angle do not exceed In creep speed conditions the shock absorber provides
80 % of rated max.energy capacity below. minimal resistance and there is no braking effect.
Return force: 1.0 to 1.2 kN. Calculation: For further details of calculation and selection
please consult ACE.
Filling pressure: Approx. 2 bar.
The calculation and selection of the correct ACE Stacker
Operating temperature range: -12°C to 66°C. Crane Shock Absorber for your application should be
(For lower temperatures please consult ACE). referred to ACE for approval and assignment of unique
Issue 4.2003 Specifications subject to change
identification number.
62 HYDNET ab: Stockholm tel:08-59 470 470 fax:08-59 470 479, Göteborg tel:031-499 490 fax:031-499 499 Malmö tel:040-66 44 511 fax:040-66 43 510