June

WHRPP Generation: 8 MW Misc 1.6 MW


T. Plant Load LS Add CMRP VCM2 VCM3 Coal Mill RM Kiln Exis
Time Solar Power
(MW) 1.1 0.4 3.5 5.00 4.8 1.5 8.4 8.2
(MW)
6:00:00 21.2 1 1 0 0 0 1 1 1 0.81
7:00:00 26.2 1 1 0 1 0 1 1 1 4.06
8:00:00 29.7 1 1 1 1 0 1 1 1 8.816
9:00:00 34.5 1 1 1 1 1 1 1 1 12.917
10:00:00 34.5 1 1 1 1 1 1 1 1 16.034
11:00:00 34.5 1 1 1 1 1 1 1 1 17.845
12:00:00 34.5 1 1 1 1 1 1 1 1 18.163
13:00:00 34.5 1 1 1 1 1 1 1 1 17.525
14:00:00 34.5 1 1 1 1 1 1 1 1 16.034
15:00:00 34.5 1 1 1 1 1 1 1 1 13.290
16:00:00 34.5 1 1 1 1 1 1 1 1 9.560
17:00:00 34.5 1 1 1 1 1 1 1 1 5.046
18:00:00 34.5 1 1 1 1 1 1 1 1 1.354

Cost saved Avera


Lost Solar KWH

Proposed Additional MW? 4


SUMMARY March (1 day) June (1 day) Sep (1 day)
Cement Mills 109 Saving PKR 159,080 101,236 227,257
without Kiln days Suppression (31,168) (25,758) (15,165)
Cement Mills 256 Saving 663,197 687,262 539,866
with Kiln days Suppression - - -
Annual Solar Generation (KWH)
Annual Suppressed (KWH)
Annual Suppression (%)
Annual Saved Amount By WAPDA Load Reduction (MPKR)
Estimated Project Cost (MPKR)
Estimated payback period of proposed additional solar (Years)
Monthly WAPDA Consumption With Kiln (KWH)
Daily WAPDA Consumption With Kiln (KWH)
Monthly WAPDA Consumption Without Kiln (KWH)
Daily WAPDA Consumption Without Kiln (KWH)
WHRPP Generation (KWH)
Annual WAPDA Consumption (KWH)
Annual WAPDA Consumption with addition (KWH)
Total Plant Consumption (KWH)
Annual Contribution of existing Solar 24.7 MW (%)
Annual Contribution of Solar with additional capacity (%)
WAPDA Consumption
WHRPP Generation
Solar Generation
Suppression

Additional Solar
Additional Suppresion
WAPDA Consumption
WHRPP Generation
Solar Generation
Existing Data With Addition
Solar Energy WAPDA Load WAPDA Solar Solar Energy WAPDA
(KWH) (MW) Consumed KWH (MW) (KWH) Load
812.83 12.387 12,387 0.944 944 12.256
4064 14.136 14,136 4.722 4,722 13.478
8,816 12.884 12,884 10.244 10,244 11.456
12,917 13.583 13,583 15.009 15,009 11.491
16,034 10.466 10,466 18.630 18,630 7.870
17,845 8.655 8,655 20.735 20,735 5.765
18,163 8.337 8,337 21.105 21,105 5.395
17,525 8.975 8,975 20.363 20,363 6.137
16,034 10.466 10,466 18.630 18,630 7.870
13,290 13.210 13,210 15.442 15,442 11.058
9,560 16.940 16,940 11.109 11,109 15.391
5,046 21.454 21,454 5.863 5,863 20.637
1,354 25.146 25,146 1.573 1,573 24.927
141,461 176,639 164,370
Cost saved Average @ PKR 39.59/KWH
Lost Solar KWH due to suppression

Kiln Run Days 256


Dec (1 day) Average (1 day) Annual Projection
123,468 152,760 -
(15,339) (21,858) (2,382,482)
499,102 597,357 152,923,344
- - -
WH) 45,584,303
H) 1,232,171
) 3%
Reduction (MPKR) (0)
PKR) 680
ditional solar (Years) -
Kiln (KWH) 7,500,000
iln (KWH) 250,000
ut Kiln (KWH) 1,500,000
Kiln (KWH) 50,000
) 49,152,000
(KWH) 69,450,000
ddition (KWH) 69,450,000
WH) 157,835,303
r 24.7 MW (%) 24%
tional capacity (%) 24%
69,450,000
49,152,000
39,233,303
1,232,171

6,351,000
-
63,099,000
49,152,000
n Results
WAPDA WAPDA Difference Reduction on
Consumed KWH (MW) WAPDA (KWH)
12,256 0.13 132
13,478 0.66 658
11,456 1.43 1,428
11,491 2.09 2,092
7,870 2.60 2,597
5,765 2.89 2,890
5,395 2.94 2,941
6,137 2.84 2,838
7,870 2.60 2,597
11,058 2.15 2,152
15,391 1.55 1,548
20,637 0.82 817
24,927 0.22 219
153,730 22,909
906,957
0

181264.071199595
WHrPP 45,316,018

Solar 39233303
62500000
5800000
WAPDA 68300000

Total 152,849,321
25.67
152375489
473,832
June
WHRPP Generation: 8 MW Misc 1.6 MW
T. Plant Load LS Add CMRP VCM2 VCM3Coal M RM Kiln Existing Data
Time ✘ ✘ ✘ ✘ ✘ ✘
Solar Power Solar Energy
(MW) 1.1 0.4 3.5 4.7 4.7 1.5 8.4 8.2
(MW) (KWH)
6:00:00 20.8 1 0 0 0 0 1 1 1 0.81 812.83
7:00:00 25.5 1 0 0 1 0 1 1 1 4.06 4064
8:00:00 29 1 0 1 1 0 1 1 1 8.816 8,816
9:00:00 33.7 1 0 1 1 1 1 1 1 12.917 12,917
10:00:00 33.7 1 0 1 1 1 1 1 1 16.034 16,034
11:00:00 33.7 1 0 1 1 1 1 1 1 17.845 17,845
12:00:00 33.7 1 0 1 1 1 1 1 1 18.163 18,163
13:00:00 33.7 1 0 1 1 1 1 1 1 17.525 17,525
14:00:00 33.7 1 0 1 1 1 1 1 1 16.034 16,034
15:00:00 33.7 1 0 1 1 1 1 1 1 13.290 13,290
16:00:00 33.7 1 0 1 1 1 1 1 1 9.560 9,560
17:00:00 33.7 1 0 1 1 1 1 1 1 5.046 5,046
18:00:00 33.7 1 0 1 1 1 1 1 1 1.354 1,354
141,461
Cost saved @ PKR
Lost Solar KWH due to

Proposed Additional MW? 0


SUMMARY March (1 day) June (1 day) Sep (1 day) Dec (1 day)
Cement Mills 115 Saving PKR - (0) -
without Kiln days Suppression (17,149) (13,101) (6,517) (6,09

Cement Mills 250 Saving 663,197 687,262 539,866 499,10
with Kiln days Suppression - - -
Annual Solar Generation (KWH)
Annual Suppressed (KWH)
Annual Suppression (%)
Annual Saved Amount By WAPDA Load Reduction (MPKR)
Estimated Project Cost (MPKR)
Estimated payback period of proposed additional solar (Years)

WAPDA Consumption
WHRPP Generation
Solar Generation
Suppression

Additional Solar
Additional Suppresion
WAPDA Consumption
WHRPP Generation
Solar Generation
Existing Data With Addition
WAPDA Load WAPDA Solar Solar Energy WAPDA WAPDA
(MW) Consumed KWH (MW) (KWH) Load Consumed KWH
11.987 11,987 0.813 813 11.987 11,987
13.436 13,436 4.064 4,064 13.436 13,436
12.184 12,184 8.816 8,816 12.184 12,184
12.783 12,783 12.917 12,917 12.783 12,783
9.666 9,666 16.034 16,034 9.666 9,666
7.855 7,855 17.845 17,845 7.855 7,855
7.537 7,537 18.163 18,163 7.537 7,537
8.175 8,175 17.525 17,525 8.175 8,175
9.666 9,666 16.034 16,034 9.666 9,666
12.410 12,410 13.290 13,290 12.410 12,410
16.140 16,140 9.560 9,560 16.140 16,140
20.654 20,654 5.046 5,046 20.654 20,654
24.346 24,346 1.354 1,354 24.346 24,346
166,839 141,461 166,839
Cost saved @ PKR 30/KWH
Lost Solar KWH due to suppression

Kiln Run Days 250


Dec (1 day) Average (1 day) Annual Projection
- (0) (0)
(6,092) (10,715) (1,232,171)
499,102 597,357 149,339,203
- - -
39,233,303
1,232,171
3%
n (MPKR) (0)
-
olar (Years) -

68,250,000
48,000,000
39,233,303
1,200,000.00 1232170.6209

-
(2,432,171)
Results
WAPDA Difference Reduction on
(MW) WAPDA (KWH)
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
0.00 -
(0)
(0)
0

181264.071199595
WHrPP 45,316,018

25.67
152375489
473,832
March
WHRPP Generation: 8.3 MW Misc 1.6 MW
T. Plant Load LS Add CMRP VCM2 VCM3 Coal M RM Kiln
Time Solar Generation
(MW) 1.1 0.4 3.5 5 4.8 1.5 8.4 8.2
(MW)
6:00:00 21.2 1 1 0 0 0 1 1 1 0
7:00:00 26.2 1 1 0 1 0 1 1 1 0.5
8:00:00 29.7 1 1 1 1 0 1 1 1 3.874
9:00:00 34.5 1 1 1 1 1 1 1 1 7.225
10:00:00 34.5 1 1 1 1 1 1 1 1 9.797
11:00:00 34.5 1 1 1 1 1 1 1 1 11.304
12:00:00 34.5 1 1 1 1 1 1 1 1 11.96
13:00:00 34.5 1 1 1 1 1 1 1 1 11.698
14:00:00 34.5 1 1 1 1 1 1 1 1 10.387
15:00:00 34.5 1 1 1 1 1 1 1 1 8.683
16:00:00 34.5 1 1 1 1 1 1 1 1 6.078
17:00:00 34.5 1 1 1 1 1 1 1 1 2.465
18:00:00 34.5 1 1 1 1 1 1 1 1 0

Proposed Additional MW? 4


8.3 MW
Existing Data With
Solar Produced WAPDA Consumed Solar Generation
WAPDA Load
(KWH) KWH (MW)
0.00 0.00 12.900 12,900 0.000
0.81 812.83 17.087 17,087 0.944
6.298 6,298 15.102 15,102 7.318
11.745 11,745 14.455 14,455 13.647
15.927 15,927 10.273 10,273 18.506
18.376 18,376 7.824 7,824 21.352
19.443 19,443 6.757 6,757 22.592
19.017 19,017 7.183 7,183 22.097
16.886 16,886 9.314 9,314 19.620
14.116 14,116 12.084 12,084 16.402
9.881 9,881 16.319 16,319 11.481
4.007 4,007 22.193 22,193 4.656
- - 26.200 26,200 0.000
136,508 177,692
Cost saved @ PKR 30/KWH
Lost Solar KWH due to suppression
With Addition Results
Solar Produced WAPDA Consumed WAPDA Load Reduction on
WAPDA Load
(KWH) KWH Difference (MW) WAPDA (KWH)
- 12.900 12,900 - -
944 16.956 16,956 0 132
7,318 14.082 14,082 1 1,020
13,647 12.553 12,553 2 1,902
18,506 7.694 7,694 3 2,579
21,352 4.848 4,848 3 2,976
22,592 3.608 3,608 3 3,149
22,097 4.103 4,103 3 3,080
19,620 6.580 6,580 3 2,735
16,402 9.798 9,798 2 2,286
11,481 14.719 14,719 2 1,600
4,656 21.544 21,544 1 649
- 26.200 26,200 - -
158,615 155,585 22,107
663197
0
LS #REF!
Add #REF!
CMRP #REF!
CM2 #REF!
CM3 #REF!
Coal #REF!
RM #REF!
Kiln #REF!
June
WHRPP Generation: 8.3 MW Misc 1.6 MW
T. Plant Load LS Add CMRP VCM2 VCM3 Coal M RM Kiln
Time Solar Generation
(MW) 1.1 0.4 3.5 5 4.8 1.5 8.4 8.2
14.36 (MW)
6:00:00 21.2 1 1 0 0 0 1 1 1 0.5
7:00:00 26.2 1 1 0 1 0 1 1 1 2.5
8:00:00 29.7 1 1 1 1 0 1 1 1 5.423
9:00:00 34.5 1 1 1 1 1 1 1 1 7.946
10:00:00 34.5 1 1 1 1 1 1 1 1 9.863
11:00:00 34.5 1 1 1 1 1 1 1 1 10.977
12:00:00 34.5 1 1 1 1 1 1 1 1 11.173
13:00:00 34.5 1 1 1 1 1 1 1 1 10.78
14:00:00 34.5 1 1 1 1 1 1 1 1 9.863
15:00:00 34.5 1 1 1 1 1 1 1 1 8.175
16:00:00 34.5 1 1 1 1 1 1 1 1 5.881
17:00:00 34.5 1 1 1 1 1 1 1 1 3.104
18:00:00 34.5 1 1 1 1 1 1 1 1 0.833

Proposed Additional MW? 4


8.3 MW
Existing Data With
Solar Produced WAPDA Consumed Solar Generation
WAPDA Load
(KWH) KWH (MW)
0.81 812.83 12.087 12,087 0.944
4.06 4064.14 13.836 13,836 4.722
8.816 8,816 12.584 12,584 10.244
12.917 12,917 13.283 13,283 15.009
16.034 16,034 10.166 10,166 18.630
17.845 17,845 8.355 8,355 20.735
18.163 18,163 8.037 8,037 21.105
17.525 17,525 8.675 8,675 20.363
16.034 16,034 10.166 10,166 18.630
13.290 13,290 12.910 12,910 15.442
9.560 9,560 16.640 16,640 11.109
5.046 5,046 21.154 21,154 5.863
1.354 1,354 24.846 24,846 1.573
141,461 172,739
Cost saved @ PKR 30/KWH
Lost Solar KWH due to suppression
6/6/2023
With Addition Results
Solar Produced WAPDA Consumed WAPDA Load Reduction on
WAPDA Load
(KWH) KWH Difference (MW) WAPDA (KWH)
944 11.956 11,956 0 132
4,722 13.178 13,178 1 658
10,244 11.156 11,156 1 1,428
15,009 11.191 11,191 2 2,092
18,630 7.570 7,570 3 2,597
20,735 5.465 5,465 3 2,890
21,105 5.095 5,095 3 2,941
20,363 5.837 5,837 3 2,838
18,630 7.570 7,570 3 2,597
15,442 10.758 10,758 2 2,152
11,109 15.091 15,091 2 1,548
5,863 20.337 20,337 1 817
1,573 24.627 24,627 0 219
164,370 149,830 22,909
687262
0
LS #REF!
Add #REF!
CMRP #REF!
CM2 #REF!
CM3 #REF!
Coal #REF!
RM #REF!
Kiln #REF!
Sep
WHRPP Generation: 8.3 MW Misc 1.6 MW
T. Plant Load LS Add CMRP VCM2 VCM3 Coal M RM Kiln
Time Solar Generation
(MW) 1.1 0.4 3.5 5 4.8 1.5 8.4 8.2
(MW)
6:00:00 21.2 1 1 0 0 0 1 1 1 0.029
7:00:00 26.2 1 1 0 1 0 1 1 1 1.454
8:00:00 29.7 1 1 1 1 0 1 1 1 4.341
9:00:00 34.5 1 1 1 1 1 1 1 1 7.028
10:00:00 34.5 1 1 1 1 1 1 1 1 8.814
11:00:00 34.5 1 1 1 1 1 1 1 1 1.0321
12:00:00 34.5 1 1 1 1 1 1 1 1 10.911
13:00:00 34.5 1 1 1 1 1 1 1 1 10.452
14:00:00 34.5 1 1 1 1 1 1 1 1 9.404
15:00:00 34.5 1 1 1 1 1 1 1 1 7.618
16:00:00 34.5 1 1 1 1 1 1 1 1 5.095
17:00:00 34.5 1 1 1 1 1 1 1 1 2.154
18:00:00 34.5 1 1 1 1 1 1 1 1 0.0232

Proposed Additional MW? 4


8.3 MW
Existing Data With
Solar Energy WAPDA Solar
Solar Power (MW) WAPDA Load (MW)
(KWH) Consumed KWH (MW)
0.05 47.14 12.853 12,853 0.055
2.36 2363.71 15.536 15,536 2.746
7.057 7,057 14.343 14,343 8.200
11.425 11,425 14.775 14,775 13.275
14.329 14,329 11.871 11,871 16.649
1.678 1,678 24.522 24,522 1.950
17.738 17,738 8.462 8,462 20.610
16.991 16,991 9.209 9,209 19.743
15.288 15,288 10.912 10,912 17.763
12.384 12,384 13.816 13,816 14.390
8.283 8,283 17.917 17,917 9.624
3.502 3,502 22.698 22,698 4.069
0.038 38 26.162 26,162 0.044
111,122 203,078
Cost saved @ PKR 30/KWH
Lost Solar KWH due to suppression
With Addition Results
Solar Energy WAPDA WAPDA WAPDA Difference Reduction on
(KWH) Load Consumed KWH (MW) WAPDA (KWH)
55 12.845 12,845 0 8
2,746 15.154 15,154 0 383
8,200 13.200 13,200 1 1,143
13,275 12.925 12,925 2 1,850
16,649 9.551 9,551 2 2,320
1,950 24.250 24,250 0 272
20,610 5.590 5,590 3 2,872
19,743 6.457 6,457 3 2,752
17,763 8.437 8,437 2 2,476
14,390 11.810 11,810 2 2,006
9,624 16.576 16,576 1 1,341
4,069 22.131 22,131 1 567
44 26.156 26,156 0 6
129,118 185,082 17,996
539866
0
LS #REF!
Add #REF!
CMRP #REF!
CM2 #REF!
CM3 #REF!
Coal #REF!
RM #REF!
Kiln #REF!
Dec
WHRPP Generation: 8.3 MW Misc 1.6 MW
T. Plant Load LS Add CMRP VCM2 VCM3 Coal M RM Kiln
Time Solar Generation
(MW) 1.1 0.4 3.5 5 4.8 1.5 8.4 8.2
(MW)
6:00:00 21.2 1 1 0 0 0 1 1 1
7:00:00 26.2 1 1 0 1 0 1 1 1 0
8:00:00 29.7 1 1 1 1 0 1 1 1 1.241
9:00:00 34.5 1 1 1 1 1 1 1 1 5.947
10:00:00 34.5 1 1 1 1 1 1 1 1 8.683
11:00:00 34.5 1 1 1 1 1 1 1 1 9.994
12:00:00 34.5 1 1 1 1 1 1 1 1 10.518
13:00:00 34.5 1 1 1 1 1 1 1 1 9.994
14:00:00 34.5 1 1 1 1 1 1 1 1 8.372
15:00:00 34.5 1 1 1 1 1 1 1 1 5.947
16:00:00 34.5 1 1 1 1 1 1 1 1 2.498
17:00:00 34.5 1 1 1 1 1 1 1 1 0
18:00:00 34.5 1 1 1 1 1 1 1 1

Proposed Additional MW? 4


8.3 MW
Existing Data With
Solar Energy WAPDA Solar
Solar Power (MW) WAPDA Load (MW)
(KWH) Consumed KWH (MW)
0.00 0.00 12.900 12,900 0.000
0.00 0.00 17.900 17,900 0.000
2.017 2,017 19.383 19,383 2.344
9.668 9,668 16.532 16,532 11.233
14.116 14,116 12.084 12,084 16.402
16.247 16,247 9.953 9,953 18.878
17.099 17,099 9.101 9,101 19.868
16.247 16,247 9.953 9,953 18.878
13.610 13,610 12.590 12,590 15.814
9.668 9,668 16.532 16,532 11.233
4.061 4,061 22.139 22,139 4.719
- - 26.200 26,200 0.000
- - 26.200 26,200 0.000
102,732 211,468
Cost saved @ PKR 30/KWH
Lost Solar KWH due to suppression
With Addition Results
Solar Energy WAPDA WAPDA WAPDA Difference Reduction on
(KWH) Load Consumed KWH (MW) WAPDA (KWH)
- 12.900 12,900 0.00 -
- 17.900 17,900 0.00 -
2,344 19.056 19,056 0.33 327
11,233 14.967 14,967 1.57 1,566
16,402 9.798 9,798 2.29 2,286
18,878 7.322 7,322 2.63 2,631
19,868 6.332 6,332 2.77 2,769
18,878 7.322 7,322 2.63 2,631
15,814 10.386 10,386 2.20 2,204
11,233 14.967 14,967 1.57 1,566
4,719 21.481 21,481 0.66 658
- 26.200 26,200 0.00 -
- 26.200 26,200 0.00 -
119,369 194,831 16,637
499102
0
LS #REF!
Add #REF!
CMRP #REF!
CM2 #REF!
CM3 #REF!
Coal #REF!
RM #REF!
Kiln #REF!
March
WHRPP Generation: 8.3 MW Misc 1.6 MW
T. Plant Load LS Add CMRP VCM2 VCM3 Coal M RM Kiln Existing Dat
Time Solar Power
(MW) 1.1 0.4 3.5 4.7 4.7 1.5 8.4 8.2
(MW)
6:00:00 24.4 0 0 0 0 ✘1 1✘ 1
✘ ✘1 0.00
7:00:00 25.5 ✘ 1 0 0 0 ✘1 1✘ 1✘ ✘1
✘ 0.81
8:00:00 25.5 ✘1 0 0 0 ✘1 1✘ 1✘ ✘1 6.298
9:00:00 33.7 ✘1 0 1✘ 1✘ ✘1 1✘ 1✘ 1
✘ 11.745
10:00:00 34.1 ✘1 ✘1 1✘ 1✘ ✘1 1✘ 1✘ 1
✘ 15.927
11:00:00 34.1 ✘1 ✘1 1✘ 1
✘ ✘1 1✘ 1✘ ✘1 18.376
12:00:00 34.1 1
✘ 1
✘ 1✘ 1✘ ✘1 1✘ 1✘ 1✘ 19.443
13:00:00 33 0 ✘1 1✘ 1✘ ✘1 1✘ 1✘ 1
✘ 19.017
14:00:00 33.7 ✘1 0 1✘ 1✘ ✘1 1✘ 1✘ 1
✘ 16.886
15:00:00 33.7 ✘1 0 1✘ 1✘ ✘1 1✘ 1✘ 1
✘ 14.116
16:00:00 33.7 ✘1 0 1✘ ✘1 ✘1 1
✘ 1
✘ ✘1 9.881
17:00:00 33.7 ✘1 0 1✘ 1✘ ✘1 1✘ 1✘ 1
✘ 4.007
18:00:00 32.6 0 0 1✘ 1✘ ✘1 1✘ 1✘ 1
✘ -

Cost saved @ PK
Lost Solar KWH due

Proposed Additional MW? 4


March (1 day) June (1 day) Sep (1 day)
Saving PKR 159,080 - -
Cement Mills
Suppression (29,368) - -
Kiln with Cement Saving 663,197 687,262 -
Mills Suppression - - -
Total Saved Amount By WAPDA Load Reduction
With Kiln run factor 50% with all 03 cement mills kept operational during solar generatio

March (1 day) June (1 day) Sep (1 day)


Saving PKR 128,484 101,236 192,973
Cement Mills
Suppression 34,586 32,358 18,665
Kiln with Cement Saving 663,197 687,262 539,866
Mills Suppression - - -
Total Saved Amount By WAPDA Load Reduction
With Kiln run factor 50% with all 03 cement mills kept operational during solar generatio
8.3 MW
Existing Data With Addition
Solar Energy WAPDA Load WAPDA Solar Solar Energy WAPDA
(KWH) (MW) Consumed KWH (MW) (KWH) Load
0.00 16.100 16,100 0.000 - 16.100
812.83 16.387 16,387 0.944 944 16.256
6,298 10.902 10,902 7.318 7,318 9.882
11,745 13.655 13,655 13.647 13,647 11.753
15,927 9.873 9,873 18.506 18,506 7.294
18,376 7.424 7,424 21.352 21,352 4.448
19,443 6.357 6,357 22.592 22,592 3.208
19,017 5.683 5,683 22.097 22,097 2.603
16,886 8.514 8,514 19.620 19,620 5.780
14,116 11.284 11,284 16.402 16,402 8.998
9,881 15.519 15,519 11.481 11,481 13.919
4,007 21.393 21,393 4.656 4,656 20.744
- 24.300 24,300 0.000 - 24.300
136,508 167,392 158,615
Cost saved @ PKR 30/KWH
Lost Solar KWH due to suppression

Dec (1 day) Average (1 day) Annual Projection


- 39,770 4,613,324.88
- (7,342) (851,673) 68.306010929
499,102 462,390 115,597,604.08
- 0 -
Load Reduction 4,613,325 1,754,000
operational during solar generation time throughout the year

Dec (1 day) Average (1 day) Annual Projection


123,468 136,540 24,918,563
17,339 25,737 4,697,003
499,102 597,357 109,017,607 680000000
- 0 - 147.40
Load Reduction 133,936,170
operational during solar generation time throughout the year
tion Results
WAPDA WAPDA Difference Reduction on
Consumed KWH (MW) WAPDA (KWH)
16,100 0.00 - ✘

16,256 0.13 132 ✘


9,882 1.02 1,020 ✘


11,753 1.90 1,902 ✘


7,294 2.58 2,579 ✘


4,448 2.98 2,976 ✘


3,208 3.15 3,149 ✘


2,603 3.08 3,080 ✘


5,780 2.73 2,735 ✘


8,998 2.29 2,286 ✘


13,919 1.60 1,600 ✘


20,744 0.65 649 ✘


24,300 0.00 - ✘

145,285 22,107
663,197
0

You might also like