Professional Documents
Culture Documents
Exon 4way Fan Coil Unit
Exon 4way Fan Coil Unit
Exon 4way Fan Coil Unit
energy consultants
200–2000
Ca
cfm
pac ge
it R a n
EXON
EXON EXON
2 warranty
years 200-2000CFM
EXON
Fan Coil Units: Cassette, Concealed,floor,Ducted
EXON
energy consultants
Features:
200-2000CFM
motor damper
2 and 4 pipe
low noise
low hight
AC & DC moto
EXON
energy consultants
EXON
Cassette
Fan Coil Unit
(for water AC system)
Yilaide’s cassette fan coil unit are terminals of a hydronic system for installation in ceiling.
They are suitable for chilled and/or hot water air conditioning system
Nomenclature
EX-68KM4-V/C-EC
68: Air flow volume, 68x10 CMH
EC: equipped with EC motor
Default AC motor)
1: 1-way
2: 2-way Desin Series:
4: 4-way A series / B series / C series
6: 6-way ACY series: for Marine Duty
Z series: for self-drainage units
V: 2-pipe system
P: 4-pipe system
Kinds of cassette units, including:
- 1-way cassette units (Normal Type)
- 1-way cassette units (Slim Type)
- 2-pipe 4-way cassette units
normal 1-way Slim type 1-way 2-pipe 4 way- A series 2-pipe 4 way- C series
- 4-pipe 4-way cassette units
- 2-pipe 2-way cassette units
- 2-pipe 6-way cassette units
- 2-pipe 4 way Cassette units
(self-drainage,drain by nature) 4-pipe 4-way-C series 4-pipe 4 way- A series 2-pipe 4 way- free pump 2-pipe 6-way
EXON
energy consultants
2-pipe 4-way cassette units
(A series)
Air Flow: 200 ~ 2000cfm
Cooling Capacity: 2.0~17.6KW
Model: EX-*KM4-V/A EX-34KM4-V/A EX-51KM4-V/A EX-68KM4-V/A EX-80KM4-V/A EX-85KM4-V/A EX-102KM4-V/A EX-136KM4-V/A EX-170KM4-V/A EX-204KM4-V/A EX-238KM4-V/A EX-289KM4-V/A EX-340KM4-V/A
CFM 200 300 400 450 500 600 800 1000 1200 1400 1700 2000
H m3/h 340 510 680 800 850 1020 1360 1700 2040 2380 2890 3400
Air Flow Rate M m3/h 280 390 520 580 640 790 1030 1290 1500 1800 2100 2600
L m3/h 180 260 350 390 430 520 690 860 1030 1200 1600 1900
H KW 2.0 2.7 3.7 4.2 4.5 5.6 7.0 9.1 10.8 12.6 15.3 17.6
Total Capacity M KW 1.8 2.3 3.1 3.8 4.2 4.3 5.7 7.9 8.6 10.0 11.7 13.5
L KW 1.6 1.8 2.6 2.8 3.0 3.6 4.5 6.0 6.8 8.0 9.3 9.9
Cooling
H KW 1.5 1.9 2.6 2.9 3.5 3.9 5.0 6.4 7.7 9.0 11.5 14.8
Sensible Capacity M KW 1.3 1.7 2.0 2.6 3.2 3.3 4.3 5.9 6.5 7.5 8.4 11.1
L KW 1.2 1.4 1.8 1.9 2.8 2.9 3.6 4.8 5.4 6.4 6.4 7.8
Water flow rate l/h 345 470 640 720 780 970 1260 1710 1920 2160 2640 3027
Water pressure drop kPa 7 9 11 14 16 18 19 17 19 22 36 48
H KW 2.8 4.2 5.6 6.3 7.0 8.4 11.2 13.9 16.7 19.5 23.7 25.5
Heat
Heating Capacity M KW 2.5 3.4 4.5 5.5 6.3 6.5 8.5 12.0 12.6 15.6 17.5 18.6
L KW 2.0 2.7 4.0 4.5 5.0 5.2 6.7 9.0 10.2 12.0 13.8 13
Power supply 220~240V/1PH/50Hz(or 60HZ)
Power Input W 39 52 62 68 76 96 132 152 189 220 330 340
Sound pressure dB(A) 37 39 41 42 43 45 46 47 50 52 57 65
Type Centrifugal Fan
Fan Model Ø315 Ø315 Ø315 Ø315 Ø380 Ø380 Ø380 Ø476 Ø476 Ø476 Ø530 Ø530
Quantity Nr. 1 1 1 1 1 1 1 1 1 1 1 1
Type 3-speed Motor
Motor
Quantity Nr. 1 1 1 1 1 1 1 1 1 1 1 1
Coil Rows Nr. 2
612
580
EX-85KM4-V/A
EX-102KM4-V/A
EX-136KM4-V/A
EX-34KM4-V/A EX-170KM4-V/A
A
B
EX-51KM4-V/A EX-204KM4-V/A
424
EX-68KM4-V/A EX-238KM4-V/A
EX-80KM4-V/A EX-289KM4-V/A
EX-85KM4-V/A EX-170KM4-V/A
EX-340KM4-V/A EX-289KM4-V/A
Dim. EX-102KM4-V/A EX-204KM4-V/A
EX-340KM4-V/A
EX-136KM4-V/A EX-238KM4-V/A
A 830 980 1140
B 338 416 488
C 737 864 992
D 705 832 960
(mm)
290
242
250
215
195
114
EXON
energy consultants
4-pipe 4-way cassette units
(A series)
Air Flow: 400~2000cfm
Cooling Capacity: 2.6KW~11.5KW
Model: EX-*KM4-P/A EX-68KM4-P/A EX-80KM4-P/A EX-85KM4-P/A EX-102KM4-P/A EX-136KM4-P/A EX-170KM4-P/A EX-204KM4-P/A EX-238KM4-P/A EX-289KM4-P/A EX-340KM4-P/A
CFM 400 450 500 600 800 1000 1200 1400 1700 2000
H m3/h 680 800 850 1020 1360 1700 2040 2380 2890 3400
Air Flow Rate M m3/h 520 580 640 790 1030 1290 1500 1800 2100 2600
L m3/h 350 390 430 520 690 860 1030 1200 1600 1900
H KW 2.6 2.8 3.1 3.6 4.8 6.0 7.0 8.4 10.3 11.5
Total Capacity M KW 2.0 2.2 2.4 2.8 3.7 4.7 6.0 6.5 7.5 8.3
L KW 1.4 1.6 1.8 2.1 3.0 3.6 4.6 5.0 5.7 6.3
Cooling
H KW 1.8 2.0 2.2 2.5 3.4 4.2 4.9 5.9 8.5 9.5
Sensible Capacity M KW 1.5 1.6 1.8 2.1 2.8 3.5 4.5 4.9 6.2 6.9
L KW 1.1 1.2 1.4 1.7 2.4 2.9 3.7 4.0 4.7 5.2
Water flow rate l/h 450 468 540 625 830 1050 1400 1500 1800 2000
Water pressure drop kPa 11 13 17 22 24 27 30 35 40 52
H KW 2.6 3.1 3.5 4.3 4.9 6.5 7.2 8.7 11.9 15.2
Heat
Heating Capacity M KW 2.0 2.3 2.7 3.2 4.3 5.4 5.6 7.6 8.7 11.3
L KW 1.4 1.7 2.1 2.5 3.5 4.2 4.3 5.8 6.6 8.7
Power supply 220~240V/1PH/50Hz(or 60HZ)
Power Input W 62 68 76 96 132 152 189 220 330 340
Sound pressure dB(A) 41 42 43 45 46 47 50 52 57 65
Type Centrifugal Fan
Fan Model Ø315 Ø315 Ø380 Ø380 Ø380 Ø476 Ø476 Ø476 Ø530 Ø530
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Type 3-speed Motor
Motor
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Coil Rows Nr. 2
www.exonholding.com
EXON
energy consultants
4-way cassette units
(Drain pump inside) - including A series & C series, for both 2-pipe & 4-pipe
--- for chilled/hot water AC system
Panel Assembly
Aesthetic panel design, in ABS material with synthetic washable and
removal air filter, auto-swing.
* In case of optional “h” and optional “i”, the control box will
be installed outside of the unit body for “C” series; Built-in
main board with no fuction of optional “h” and “i” for “C”
series.
www.exonholding.com
EXONenergy consultants
Network control module --- optional for cassette fan coil unit
The NCM module offers the possibility to control the fan coil unit together. There are two kinds of network control:
A. Master-slave network control. In this way, use wire wall pad and PCB together to control all the FCUs. One
group can control at most 32 pcs of FCU.
B. Host computer network control. In this way ,use computer , converter, data logger and PCB to control all
FCUs. The maximum network size is 64 data loggers x 32 FCUs = 2048 FCUs connected to a computer based
control system.
There are two methods to use the master-slave network control function, one is by remote controller, and the
other is using wire wall pad.
Computer
EXON EXON EXON EXON
RS232-RS485
Convecter
up to 32units
Data logger
up to 32units
Data logger
up to 64 group
www.exonholding.com
EXON
energy consultants
Sales t: 021-88552530 e: SALES@EXONHOLDING.COM
Service t: 021-88552530 e: SERVICE@EXONHOLDING.COM
Fax: 021-88552530
WWW.EXONHOLDING.COM
EXON
energy consultants
en
e r g y s a v i ng