Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

El Dorado Truss Company, Inc.

300 Industrial Drive - Placerville, CA 95667


Tel: (530) 622-1264
Fax: (530) 622-0242

Truss Calculations

Customer : Ù·²¦¾«®¹

Project : îëçð ß³»®·½¿² ߪ»


Í¿½®¿³»²¬±ô Ýß

Date : ïðñìñîðîí

Job # îíïðíê
30-00-00
17-00-00

B5

Vaulted Ceiling

B4(12)
B3(4)

FAU Platform

B2

B2

B1

A2

A2

A1

18-11-08

ROOF TRUSS LAYOUT


Ginzburg
Scale: NTS
2590 American Ave
Job#: 231036 Date: 10/4/2023 Sacramento, CA
MiTek, Inc.
400 Sunrise Ave., Suite 270
Roseville, CA 95661
916.755.3571

Re: 231036A
Ginzburg - 2590 American Ave

The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by El Dorado Truss Co., Inc..

Pages or sheets covered by this seal: R78717049 thru R78717055


My license renewal date for the state of California is June 30, 2024.

October 4,2023
Baxter, David

IMPORTANT NOTE: The seal on these truss component designs is a certification


that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek or TRENCO. Any project specific information included is for MiTek's or
TRENCO's customers file reference purpose only, and was not taken into account in the
preparation of these designs. MiTek or TRENCO has not independently verified the
applicability of the design parameters or the designs for any particular building. Before use,
the building designer should verify applicability of design parameters and properly
incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.
Job Truss Truss Type Qty Ply Ginzburg - 2590 American Ave
R78717049
231036A A1 GABLE 1 1
Job Reference (optional)
El Dorado Truss Co., Inc., Placerville, CA - 95667, 8.720 s Aug 11 2023 MiTek Industries, Inc. Tue Oct 3 16:10:35 2023 Page 1
ID:UPdGXpAJb39Ey2EyBB7F_kydPBZ-Y1bMeslTpfk0XGNW?4GFWn48A1joP4anQBf4zLyX40o
-2-0-0 9-5-12 18-11-8 20-5-8
2-0-0 9-5-12 9-5-12 1-6-0

Scale = 1:36.0

3x8

8 9 10

7 11

5.00 12 6 12

5 13
4-3-7

4 14

3 15
31
30
2 16
0-4-1

0-4-1
17
1
3x4 29 28 27 26 25 24 23 22 21 20 19 18 3x4

18-11-8
18-11-8
Plate Offsets (X,Y)-- [9:0-4-0,Edge]

LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.15 TC 0.22 Vert(LL) -0.01 17 n/r 120 MT20 220/195
TCDL 14.0 Lumber DOL 1.15 BC 0.06 Vert(CT) -0.01 17 n/r 120
BCLL 0.0 * Rep Stress Incr NO WB 0.03 Horz(CT) 0.00 16 n/a n/a
BCDL 10.0 Code IBC2021/TPI2014 Matrix-S Weight: 96 lb FT = 20%

LUMBER- BRACING-
TOP CHORD 2X4 DF No.1&Btr G TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2X4 DF No.1&Btr G BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2X4 DF Std G

REACTIONS. All bearings 18-11-8.


(lb) - Max Horz 2=63(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 16, 19, 20, 21, 22, 28, 27, 26, 25 except 2=-102(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 16, 24, 23, 18, 19, 20, 21, 22, 29, 28, 27, 26, 25 except
2=305(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES- (11)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat.
II; Exp C; Enclosed; MWFRS (directional) and C-C Corner(3E) -2-0-0 to 1-0-0, Exterior(2N) 1-0-0 to 9-5-12, Corner(3R) 9-5-12 to
12-3-8, Exterior(2N) 12-3-8 to 20-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide
will fit between the bottom chord and any other members.
9) A plate rating reduction of 20% has been applied for the green lumber members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 19, 20, 21,
22, 28, 27, 26, 25 except (jt=lb) 2=102.
11) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.

October 4,2023

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 400 Sunrise Ave., Suite 270
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Roseville, CA 95661
and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 916.755.3571 / MiTek-US.com
Job Truss Truss Type Qty Ply Ginzburg - 2590 American Ave
R78717050
231036A A2 Common 2 1
Job Reference (optional)
El Dorado Truss Co., Inc., Placerville, CA - 95667, 8.720 s Aug 11 2023 MiTek Industries, Inc. Tue Oct 3 16:10:36 2023 Page 1
ID:UPdGXpAJb39Ey2EyBB7F_kydPBZ-0E9krCm5azst9QyjZonU2?dJ0R?88UqxerPdVnyX40n
-2-0-0 5-0-12 9-5-12 13-10-12 18-11-8 20-5-8
2-0-0 5-0-12 4-5-0 4-5-0 5-0-12 1-6-0

Scale = 1:36.0

4x6

5.00 12 18
17
2x4 2x4
3 5
4-3-7

19
16
2 6
0-4-1

0-4-1
7
1 9 8
3x4 3x4
3x4 3x4

6-6-7 12-5-1 18-11-8


6-6-7 5-10-10 6-6-7
Plate Offsets (X,Y)-- [2:0-1-6,0-0-4], [6:0-1-6,0-0-4]

LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.15 TC 0.22 Vert(LL) -0.04 8-9 >999 360 MT20 220/195
TCDL 14.0 Lumber DOL 1.15 BC 0.30 Vert(CT) -0.15 8-15 >999 240
BCLL 0.0 * Rep Stress Incr NO WB 0.22 Horz(CT) 0.04 6 n/a n/a
BCDL 10.0 Code IBC2021/TPI2014 Matrix-AS Weight: 78 lb FT = 20%

LUMBER- BRACING-
TOP CHORD 2X4 DF No.1&Btr G TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2X4 DF No.1&Btr G BOT CHORD Rigid ceiling directly applied.
WEBS 2X4 DF Std G

REACTIONS. (size) 2=0-5-8, 6=0-5-8


Max Horz 2=63(LC 11)
Max Uplift 2=-117(LC 12), 6=-97(LC 12)
Max Grav 2=973(LC 1), 6=933(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1608/272, 3-4=-1420/259, 4-5=-1433/259, 5-6=-1612/273
BOT CHORD 2-9=-168/1438, 8-9=-64/980, 6-8=-182/1455
WEBS 4-8=-56/492, 5-8=-329/142, 4-9=-48/473, 3-9=-319/139

NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -2-0-0 to 1-0-0, Interior(1) 1-0-0 to 9-5-12, Exterior(2R) 9-5-12 to
12-5-12, Interior(1) 12-5-12 to 20-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide
will fit between the bottom chord and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) H1 Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 6. This connection
is for uplift only and does not consider lateral forces.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
8) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.

October 4,2023

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 400 Sunrise Ave., Suite 270
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Roseville, CA 95661
and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 916.755.3571 / MiTek-US.com
Job Truss Truss Type Qty Ply Ginzburg - 2590 American Ave
R78717051
231036A B1 GABLE 1 1
Job Reference (optional)
El Dorado Truss Co., Inc., Placerville, CA - 95667, 8.720 s Aug 11 2023 MiTek Industries, Inc. Tue Oct 3 16:10:38 2023 Page 1
ID:UPdGXpAJb39Ey2EyBB7F_kydPBZ-ycHUGunM6a6aOj65hCqy8QieXEhjcDuD69ukZgyX40l
-1-6-0 5-11-8 11-3-4 15-0-0 18-8-12 24-0-8 30-0-0 31-6-0
1-6-0 5-11-8 5-3-12 3-8-12 3-8-12 5-3-12 5-11-8 1-6-0

Scale = 1:57.0
4x8

3x4
3x4
5
4x4
3x6
54 55 3x4
5.00 12 4 6
3x4

3x4 4x12
6-7-1

6-5-2
6-3-4

3 7

53 56
2 8
0-4-1

0-4-1
1 9

11
3x8 12 10
19 18 17 16 15 14 13 3x8 3x4
4x8
3x4

5-11-8 11-3-4 18-8-12 24-0-8 30-0-0


5-11-8 5-3-12 7-5-8 5-3-12 5-11-8
Plate Offsets (X,Y)-- [2:0-1-14,0-0-2], [6:0-5-0,0-1-4], [21:0-1-13,0-1-0], [22:0-1-9,0-1-0], [36:0-1-14,0-1-0]

LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.15 TC 0.28 Vert(LL) -0.05 12-13 >999 360 MT20 220/195
TCDL 14.0 Lumber DOL 1.15 BC 0.30 Vert(CT) -0.17 12-13 >999 240
BCLL 0.0 * Rep Stress Incr NO WB 0.89 Horz(CT) 0.02 8 n/a n/a
BCDL 10.0 Code IBC2021/TPI2014 Matrix-AS Weight: 221 lb FT = 20%

LUMBER- BRACING-
TOP CHORD 2X4 DF No.1&Btr G TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2X4 DF No.1&Btr G BOT CHORD Rigid ceiling directly applied.
WEBS 2X4 DF Std G *Except*
20-21,21-22,13-22: 2X6 DF SS G
OTHERS 2X4 DF Std G

REACTIONS. All bearings 11-6-0 except (jt=length) 8=0-5-8.


(lb) - Max Horz 2=-98(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 2, 13, 18, 14, 8 except 16=-110(LC 24)
Max Grav All reactions 250 lb or less at joint(s) 2, 16, 19, 18, 17, 15, 14, 2 except 13=1523(LC 1), 8=804(LC
1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=0/550, 4-5=0/508, 5-6=-620/166, 6-7=-636/108, 7-8=-1248/116
BOT CHORD 10-12=-41/1112, 8-10=-41/1112
WEBS 5-12=-85/841, 6-12=-313/120, 7-12=-650/82, 5-13=-1027/73, 4-13=-353/118,
3-13=-348/75

NOTES- (12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-6-0 to 1-6-0, Interior(1) 1-6-0 to 15-0-0, Exterior(2R) 15-0-0 to
18-0-0, Interior(1) 18-0-0 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide
will fit between the bottom chord and any other members.
8) A plate rating reduction of 20% has been applied for the green lumber members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13, 18, 14, 2
except (jt=lb) 16=110.
10) N/A

11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
12) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.
October 4,2023

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 400 Sunrise Ave., Suite 270
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Roseville, CA 95661
and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 916.755.3571 / MiTek-US.com
Job Truss Truss Type Qty Ply Ginzburg - 2590 American Ave
R78717052
231036A B2 Common 2 1
Job Reference (optional)
El Dorado Truss Co., Inc., Placerville, CA - 95667, 8.720 s Aug 11 2023 MiTek Industries, Inc. Tue Oct 3 16:10:40 2023 Page 1
ID:UPdGXpAJb39Ey2EyBB7F_kydPBZ-u?PFhZpceBMId1GUodsQDrnzF2NE4E1WZTNreZyX40j
-1-6-0 5-11-8 11-3-4 15-0-0 18-8-12 24-0-8 30-0-0 31-6-0
1-6-0 5-11-8 5-3-12 3-8-12 3-8-12 5-3-12 5-11-8 1-6-0

Scale = 1:52.9

4x4

2x4 2x4
22 23
5.00 12 4 6

3x4 3x4
6-7-1

3 7

21 24

2 8
0-4-1

0-4-1
1 9
25 26 11
14 13 12 10
4x8 3x8 3x4
3x4 2x4 4x8 2x4

5-11-8 11-3-4 18-8-12 24-0-8 30-0-0


5-11-8 5-3-12 7-5-8 5-3-12 5-11-8

LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.15 TC 0.33 Vert(LL) -0.07 12-13 >999 360 MT20 220/195
TCDL 14.0 Lumber DOL 1.15 BC 0.29 Vert(CT) -0.19 12-13 >999 240
BCLL 0.0 * Rep Stress Incr NO WB 0.40 Horz(CT) 0.02 8 n/a n/a
BCDL 10.0 Code IBC2021/TPI2014 Matrix-AS Weight: 142 lb FT = 20%

LUMBER- BRACING-
TOP CHORD 2X4 DF No.1&Btr G TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2X4 DF No.1&Btr G BOT CHORD Rigid ceiling directly applied.
WEBS 2X4 DF Std G WEBS 1 Row at midpt 5-13

REACTIONS. (size) 2=0-5-8, 13=0-5-8, 8=0-5-8


Max Horz 2=-101(LC 10)
Max Uplift 2=-71(LC 12), 13=-92(LC 12), 8=-94(LC 12)
Max Grav 2=420(LC 23), 13=1704(LC 1), 8=796(LC 24)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-269/161, 3-4=-8/651, 4-5=0/626, 5-6=-593/161, 6-7=-610/98, 7-8=-1223/107
BOT CHORD 10-12=-33/1089, 8-10=-33/1089
WEBS 5-12=-90/844, 6-12=-316/123, 7-12=-659/84, 5-13=-1122/79, 4-13=-322/124,
3-13=-668/85

NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-6-0 to 1-6-0, Interior(1) 1-6-0 to 15-0-0, Exterior(2R) 15-0-0 to
18-0-0, Interior(1) 18-0-0 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) H1 Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2, 13, and 8. This
connection is for uplift only and does not consider lateral forces.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
8) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.

October 4,2023

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 400 Sunrise Ave., Suite 270
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Roseville, CA 95661
and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 916.755.3571 / MiTek-US.com
Job Truss Truss Type Qty Ply Ginzburg - 2590 American Ave
R78717053
231036A B3 Common 4 1
Job Reference (optional)
El Dorado Truss Co., Inc., Placerville, CA - 95667, 8.720 s Aug 11 2023 MiTek Industries, Inc. Tue Oct 3 16:10:41 2023 Page 1
ID:UPdGXpAJb39Ey2EyBB7F_kydPBZ-NByduvpEOVU9FBrgMLNfl2K3iScIphRgo76OA?yX40i
-1-6-0 7-9-14 12-0-0 15-0-0 18-0-0 22-2-2 30-0-0 31-6-0
1-6-0 7-9-14 4-2-2 3-0-0 3-0-0 4-2-2 7-9-14 1-6-0

Scale = 1:53.8

4x4

5
3x4 3x4
4 6
5.00 12
15
3x4 3x4
2x4
3 7
6-7-1

22 23

2 8
0-4-1

0-4-1
0-3-8
1 9
24 25 11
14 13 12 10
4x4 4x4 4x8 3x8
3x8 2x4 4x12 4x12 2x4

7-9-14 12-0-0 15-0-0 18-0-0 22-2-2 30-0-0


7-9-14 4-2-2 3-0-0 3-0-0 4-2-2 7-9-14
Plate Offsets (X,Y)-- [2:0-4-2,0-1-8], [8:0-4-2,0-1-8], [12:0-3-8,0-2-4], [13:0-3-8,0-2-4]

LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.15 TC 0.67 Vert(LL) -0.20 13-14 >999 360 MT20 220/195
TCDL 14.0 Lumber DOL 1.15 BC 0.69 Vert(CT) -0.46 13-14 >776 240
BCLL 0.0 * Rep Stress Incr NO WB 0.39 Horz(CT) 0.13 8 n/a n/a
BCDL 10.0 Code IBC2021/TPI2014 Matrix-AS Weight: 145 lb FT = 20%

LUMBER- BRACING-
TOP CHORD 2X4 DF No.1&Btr G TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2X4 DF No.1&Btr G *Except* BOT CHORD Rigid ceiling directly applied.
12-13: 2X6 DF SS G JOINTS 1 Brace at Jt(s): 15
WEBS 2X4 DF Std G

REACTIONS. (size) 2=0-5-8, 8=0-5-8


Max Horz 2=-101(LC 10)
Max Uplift 2=-29(LC 12), 8=-29(LC 12)
Max Grav 2=1522(LC 1), 8=1522(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2950/0, 3-4=-2378/0, 4-5=-508/94, 5-6=-508/94, 6-7=-2378/0, 7-8=-2950/0
BOT CHORD 2-14=0/2648, 13-14=0/2648, 12-13=0/2133, 10-12=0/2646, 8-10=0/2646
WEBS 7-12=-799/96, 7-10=0/280, 3-13=-799/96, 3-14=0/280, 4-13=0/644, 6-12=0/644,
4-15=-1723/0, 6-15=-1723/0

NOTES- (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-6-0 to 1-6-0, Interior(1) 1-6-0 to 15-0-0, Exterior(2R) 15-0-0 to
18-0-0, Interior(1) 18-0-0 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) 200.0lb AC unit load placed on the bottom chord, 15-0-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) H1 Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 8. This connection
is for uplift only and does not consider lateral forces.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
9) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.

October 4,2023

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 400 Sunrise Ave., Suite 270
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Roseville, CA 95661
and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 916.755.3571 / MiTek-US.com
Job Truss Truss Type Qty Ply Ginzburg - 2590 American Ave
R78717054
231036A B4 Roof Special 12 1
Job Reference (optional)
El Dorado Truss Co., Inc., Placerville, CA - 95667, 8.720 s Aug 11 2023 MiTek Industries, Inc. Tue Oct 3 16:10:42 2023 Page 1
ID:UPdGXpAJb39Ey2EyBB7F_kydPBZ-rNW?6Fqs9pd0tLQsw2uuIGtHsswNY1Tp1nsxiRyX40h
-1-6-0 4-9-10 8-8-12 15-0-0 17-0-0 23-2-2 30-0-0 31-6-0
1-6-0 4-9-10 3-11-2 6-3-4 2-0-0 6-2-2 6-9-14 1-6-0

Scale = 1:53.8

6x6

5
2x4
6
22 23
5.00 12
4x6
4 3x4
7
6-7-1

3x4
3

21 24

1-8-11
13
2 8
8x16
0-4-1

0-4-1
14 12 9
1
2x4 3x8
11 10
4x8
6x8 2x4 3x6
2.50 12

4-9-10 8-8-12 12-10-6 17-0-0 23-2-2 30-0-0


4-9-10 3-11-2 4-1-10 4-1-10 6-2-2 6-9-14
Plate Offsets (X,Y)-- [2:0-2-5,0-0-9], [4:0-2-0,0-2-0], [8:0-0-6,0-0-0], [11:0-5-12,0-3-0], [13:0-8-0,0-3-9]

LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.15 TC 0.45 Vert(LL) -0.26 13 >999 360 MT20 220/195
TCDL 14.0 Lumber DOL 1.15 BC 0.83 Vert(CT) -0.88 13-14 >411 240
BCLL 0.0 * Rep Stress Incr NO WB 0.85 Horz(CT) 0.41 8 n/a n/a
BCDL 10.0 Code IBC2021/TPI2014 Matrix-AS Weight: 140 lb FT = 20%

LUMBER- BRACING-
TOP CHORD 2X4 DF No.1&Btr G TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2X4 DF No.1&Btr G BOT CHORD Rigid ceiling directly applied.
WEBS 2X4 DF Std G WEBS 1 Row at midpt 4-12

REACTIONS. (size) 2=0-5-8, 8=0-5-8


Max Horz 2=101(LC 11)
Max Uplift 2=-129(LC 12), 8=-129(LC 12)
Max Grav 2=1422(LC 1), 8=1422(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4890/316, 3-4=-4605/331, 4-5=-2372/239, 5-6=-1968/268, 6-7=-2039/223,
7-8=-2781/222
BOT CHORD 2-14=-230/4529, 13-14=-231/4547, 12-13=-204/4333, 11-12=-28/1742, 10-11=-133/2503,
8-10=-133/2503
WEBS 3-13=-274/28, 4-13=-43/1919, 4-12=-2576/206, 5-12=-32/1107, 5-11=-87/454,
6-11=-282/111, 7-11=-778/90, 7-10=0/282

NOTES- (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-6-0 to 1-6-0, Interior(1) 1-6-0 to 15-0-0, Exterior(2R) 15-0-0 to
18-0-0, Interior(1) 18-0-0 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide
will fit between the bottom chord and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) H1 Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 8. This connection
is for uplift only and does not consider lateral forces.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
9) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.

October 4,2023

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 400 Sunrise Ave., Suite 270
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Roseville, CA 95661
and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 916.755.3571 / MiTek-US.com
Job Truss Truss Type Qty Ply Ginzburg - 2590 American Ave
R78717055
231036A B5 GABLE 1 1
Job Reference (optional)
El Dorado Truss Co., Inc., Placerville, CA - 95667, 8.720 s Aug 11 2023 MiTek Industries, Inc. Tue Oct 3 16:10:44 2023 Page 1
ID:UPdGXpAJb39Ey2EyBB7F_kydPBZ-nmelXxs6hQtk6eZF1TwMNhyjVfoJ08Q6U5L2nKyX40f
-1-6-0 15-0-0 30-0-0 31-6-0
1-6-0 15-0-0 15-0-0 1-6-0

Scale = 1:53.8
PER ICC CODES (IRC/IBC), TPI 1 AND REFERENCED BCSI, 3x8
FLAT BOTTOM CHORD GABLE TRUSSES ARE NOT TO BE
INSTALLED ADJACENT TO SCISSOR TRUSSES UNLESS
SPECIAL OUT OF PLANE WALL BRACING IS SPECIFIED 12 13 14
BY THE ENGINEER OF RECORD. 15
11
10 16
5.00 12
9 17
8 18
7 19
6-7-1

6 20
5 21
4 22
3 23
47 48

2 24
0-4-1

0-4-1
1 25

3x4 3x4
46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26
3x8

30-0-0
30-0-0
Plate Offsets (X,Y)-- [13:0-4-0,Edge]

LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.15 TC 0.12 Vert(LL) -0.01 25 n/r 120 MT20 220/195
TCDL 14.0 Lumber DOL 1.15 BC 0.03 Vert(CT) -0.01 25 n/r 120
BCLL 0.0 * Rep Stress Incr NO WB 0.05 Horz(CT) 0.00 24 n/a n/a
BCDL 10.0 Code IBC2021/TPI2014 Matrix-S Weight: 181 lb FT = 20%

LUMBER- BRACING-
TOP CHORD 2X4 DF No.1&Btr G TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2X4 DF No.1&Btr G BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2X4 DF Std G

REACTIONS. All bearings 30-0-0.


(lb) - Max Horz 2=-101(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 2, 27, 28, 29, 30, 31, 33, 34, 35, 45, 44, 43, 42, 41, 40, 39,
38, 24
Max Grav All reactions 250 lb or less at joint(s) 2, 37, 36, 26, 27, 28, 29, 30, 31, 33, 34, 35, 46, 45, 44,
43, 42, 41, 40, 39, 38, 24

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES- (11)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=2ft; Cat.
II; Exp C; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-6-0 to 1-6-0, Exterior(2N) 1-6-0 to 15-0-0, Corner(3R) 15-0-0 to
18-0-0, Exterior(2N) 18-0-0 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) A plate rating reduction of 20% has been applied for the green lumber members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 27, 28, 29, 30,
31, 33, 34, 35, 45, 44, 43, 42, 41, 40, 39, 38, 24.
11) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.

October 4,2023

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 400 Sunrise Ave., Suite 270
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Roseville, CA 95661
and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 916.755.3571 / MiTek-US.com
PLATE LOCATION AND ORIENTATION
1/
6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property
Center plate on joint unless x, y
2 L offsets are indicated. (Drawings not to scale) Damage or Personal Injury
Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g.
Apply plates to both sides of truss 1
Joint ID diagonal or X-bracing, is always required. See BCSI.
2 3 typ.
and fully embed teeth.
TOP CHORDS 2. Truss bracing must be designed by an engineer. For
1 C1-2 C2-3 wide truss spacing, individual lateral braces themselves
0- / 16" 4
may require bracing, or alternative Tor I
WEBS C3
-4 bracing should be considered.
TOP CHORD

TOP CHORD
W2-7

W3-6
C1-8

7 3. Never exceed the design loading shown and never


1-

3-
7

W stack materials on inadequately braced trusses.

C4-5
6
4-
W
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
C7-8 C6-7 C5-6 all other interested parties.
For 4 x 2 orientation, locate
BOTTOM CHORDS
plates 0- 1/16" from outside 5. Cut members to bear tightly against each other.
edge of truss. 8 7 6 5
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE locations are regulated by ANSI/TPI 1.
This symbol indicates the
required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
7. Design assumes trusses will be suitably protected from
connector plates. THE LEFT. the environment in accord with ANSI/TPI 1.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 8. Unless otherwise noted, moisture content of lumber
* Plate location details available in MiTek NUMBERS/LETTERS. shall not exceed 19% at time of fabrication.
software or upon request.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
PLATE SIZE
10. Camber is a non-structural consideration and is the
The first dimension is the plate responsibility of truss fabricator. General practice is to
ICC-ES Reports:
4x4 width measured perpendicular
to slots. Second dimension is ESR-1988, ESR-2362, ESR-2685, ESR-3282
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
the length parallel to slots. ESR-4722, ESL-1388 indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
LATERAL BRACING LOCATION in all respects, equal to or better than that
specified.
Indicated by symbol shown and/or 13. Top chords must be sheathed or purlins provided at
by text in the bracing section of the Trusses are designed for wind loads in the plane of the spacing indicated on design.
output. Use T or I bracing truss unless otherwise shown. 14. Bottom chords require lateral bracing at 10 ft. spacing,
if indicated. or less, if no ceiling is installed, unless otherwise noted.
Lumber design values are in accordance with ANSI/TPI 1
BEARING section 6.3 These truss designs rely on lumber values 15. Connections not shown are the responsibility of others.
established by others. 16. Do not cut or alter truss member or plate without prior
Indicates location where bearings approval of an engineer.
(supports) occur. Icons vary but © 2023 MiTek® All Rights Reserved 17. Install and load vertically unless indicated otherwise.
reaction section indicates joint
number/letter where bearings occur. 18. Use of green or treated lumber may pose unacceptable
Min size shown is for crushing only. environmental, health or performance risks. Consult with
project engineer before use.
Industry Standards: 19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
ANSI/TPI1: National Design Specification for Metal is not sufficient.
Plate Connected Wood Truss Construction.
DSB-22: Design Standard for Bracing. 20. Design assumes manufacture in accordance with
BCSI: Building Component Safety Information, ANSI/TPI 1 Quality Criteria.
Guide to Good Practice for Handling, 21. The design does not take into account any dynamic
Installing, Restraining & Bracing of Metal or other loads other than those expressly stated.
Plate Connected Wood Trusses. MiTek Engineering Reference Sheet: MII-7473 rev. 1/2/2023

You might also like