Pb-2 Schedule of Loads Pb-1 Schedule of Loads: To Service Entrance
Pb-2 Schedule of Loads Pb-1 Schedule of Loads: To Service Entrance
1 LIGHTING OUTLET 3 300 220 1.36 15A 2 - 2.0 mm² THHN STRANDED WIRE M MAIN 60A 2 - 14 mm² THHN STRANDED WIRE
2 LIGHTING OUTLET 4 400 220 1.82 15A 2 - 2.0 mm² THHN STRANDED WIRE 1 1.5 HP ACU OUTLET 1 1119 220 5.1 30A 2 - 5.5 mm² THHN STRANDED WIRE
3 CONVENIENCE OUTLET 5 900 220 4.1 20A 2 - 3.5 mm² THHN STRANDED WIRE 2 CONVENIENCE OUTLET 9 1620 220 7.36 20A 2 - 3.5 mm² THHN STRANDED WIRE
4 SPARE 220 20A 2 - 3.5 mm² THHN STRANDED WIRE 3 1.5 HP ACU OUTLET 1 1119 220 5.1 30A 2 - 5.5 mm² THHN STRANDED WIRE
5 SPARE 220 30A 2 - 5.5 mm² THHN STRANDED WIRE 4 LIGHTING OUTLET 11 1100 220 5 15A 2 - 2.0 mm² THHN STRANDED WIRE
6 SPARE 220 20A 2 - 3.5 mm² THHN STRANDED WIRE 5 1.5 HP ACU OUTLET 1 1119 220 5.1 30A 2 - 5.5 mm² THHN STRANDED WIRE
A S BU ILT ELECT RIC AL PLA N OF 1 S TORE Y R ESI DENTI AL BUIL DING E-2