Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Project No.

: SSG-RA-G5-2024 Date : 16-Apr-2024


Doc No. : SSG-RA-P5-G5-2024 Prepared by : NFL
Equipment tag : E-201 Checked by : Vegapunk
Project Name :
Shell and Tube Heat Exchanger Rating Calculation Using
Tittle :
Effectiveness-NTU Method
Revision No. 0

1. CALCULATION OBJECTIVE
The objective of this calculation is to observe outlet temperature of the new hot
fluid from existing heat exchanger. This is a rating calculation and done using NTU-
Effectiveness analysis method.

2. GENERAL INFORMATION
Equipment name = Glycerol Cooler
Tag number = E-201
P&ID refference = SSG-RA-P1-G5-2024
P&ID sheet = 6 of 9

3. DESIGN CONDITION
3.1 Tube Side Data
Fluid name = Hot Propanol
Fluid allocation = Hot Fluid
Flowrate F = 15 m3/h
0
Inlet temperature T-in = 90 C
0
Outlet temperature T-out = 48 C
Average density ρ = 739,47 kg/m3
Average heat capacity Cp = 3.134 J/kg0C

3.2 Shell Side Data


Fluid name = Cooling Water
Fluid allocation = Cold Fluid
Flowrate F = 144 m3/h
0
Inlet temperature T-in = 32,0 C
0
Outlet temperature T-out = 36,5 C
Average density ρ = 996,39 kg/m3
Average heat capacity Cp = 4.200 J/kg0C

3.3 Heat Exchanger Data


Heat exchanger type = Shell and Tube
Shell material = SS-304
Tubes material = SS-316
Flow direction = Parallel-flow
Number of tube pass n_tube = 2 pass
Number of shell pass n_shell = 1 pass
Number of baffles n_bf = 5 pcs
Overall heat transfer coefficient U = 2.363 W/m2 0C
Heat transfer area A = 21 m2
0
Log mean temperature ΔT LMTD = 31,2 C
Heat duty Q = 1.549,5 kW
Project No. : SSG-RA-G5-2024 Date : 16-Apr-2024
Doc No. : SSG-RA-P5-G5-2024 Prepared by : NFL
Equipment tag : E-201 Checked by : Vegapunk
Project Name :
Shell and Tube Heat Exchanger Rating Calculation Using
Tittle :
Effectiveness-NTU Method
Revision No. 0

3.4 Schematic Diagram


Shell inlet
144 m3h
32,0 0C
Tube outlet
15 m3h
0
48 C

Tube inlet
15 m3h
0
90 C
Shell outlet
144 m3h
0
36,5 C

4. RATING CONDITION
4.1 Tube Side Data
Fluid name = HOT Triethylene Glycol 60%
Fluid allocation = Hot Fluid
Flowrate F = 20 m3/h
0
Inlet temperature T-in = 90 C
Average density ρ = 1.065,34 kg/m3
Average heat capacity Cp = 1.904 J/kg0C

4.2 Shell Side Data


Fluid name = Cooling Water
Fluid allocation = Cold Fluid
Flowrate F = 144 m3/h
0
Inlet temperature T-in = 32,0 C
0
Outlet temperature T-out = 36 C
Average density ρ = 996,39 kg/m3
Average heat capacity Cp = 4.200 J/kg0C

4.3 Heat Exchanger Data


Heat exchanger type = Shell and Tube
Shell material = SS-304
Tubes material = SS-316
Flow direction = Parallel-flow
Number of tube pass n_tube = 2 pass
Number of shell pass n_shell = 1 pass
Number of baffles n_bf = 5 pcs
Overall heat transfer coefficient U = 2.363 W/m2 0C
Heat transfer area A = 21 m2
Project No. : SSG-RA-G5-2024 Date : 16-Apr-2024
Doc No. : SSG-RA-P5-G5-2024 Prepared by : NFL
Equipment tag : E-201 Checked by : Vegapunk
Project Name :
Shell and Tube Heat Exchanger Rating Calculation Using
Tittle :
Effectiveness-NTU Method
Revision No. 0

4.4 Schematic Diagram


Shell inlet
144 m3h
32,0 0C
Tube outlet
20 m3h
0
x C

Tube inlet
20 m3h
0
90 C
Shell outlet
144 m3h
0
36,0 C

5. RATING CALCULATION
Calculation are started by determine minimum heat capacity rate. The minimum heat
capacity rate could be from hot fluid or cold fluid.

𝐶ℎ𝑜𝑡 = 𝑚ℎ𝑜𝑡 𝑐𝑝ℎ𝑜𝑡 and


𝐶𝑐𝑜𝑙𝑑 = 𝑚𝑐𝑜𝑙𝑑 𝑐𝑝𝑐𝑜𝑙𝑑

𝐶ℎ𝑜𝑡 , 𝑖𝑓 𝐶ℎ𝑜𝑡 < 𝐶𝑐𝑜𝑙𝑑


𝐶𝑚𝑖𝑛 = ቊ
𝐶𝑐𝑜𝑙𝑑 , 𝑖𝑓 𝐶𝑐𝑜𝑙𝑑 < 𝐶ℎ𝑜𝑡

Hot fluid mass flow rate m_hot = 5,9 kg/s


Cold fluid mass flow rate m_cold = 39,8 kg/s
Hot fluid heat capacity rate C_hot = 11,3 kW/0C
Cold fluid heat capacity rate C_hot = 167,3 kW/0C

Minimum heat capacity rate selected C_min = 11,3 kW/0C


Maximum heat capacity rate selected C_max = 167,3 kW/0C

Heat capacity ratio is dimensionless parameter which a ratio between minimum and maximum
heat capacity of correspond fluid
𝐶𝑚𝑖𝑛
𝐶𝑟 =
𝐶𝑚𝑎𝑥
Heat capacity ratio Cr = 0,1

Now introducing Number of Transfer Unit (NTU), which is also dimensionless parameter
that is widely used for heat exchanger analysis. NTU described as ratio UA from heat
exchanger to minimum heat capacity rate
Project No. : SSG-RA-G5-2024 Date : 16-Apr-2024
Doc No. : SSG-RA-P5-G5-2024 Prepared by : NFL
Equipment tag : E-201 Checked by : Vegapunk
Project Name :
Shell and Tube Heat Exchanger Rating Calculation Using
Tittle :
Effectiveness-NTU Method
Revision No. 0

𝑈𝐴
𝑁𝑇𝑈 =
𝐶𝑚𝑖𝑛

Number of transfer unit NTU = 4,4

Then calculate the effectiveness (ε), as the ratio of the actual heat transfer rate
for a heat exchanger to the maximum possible heat transfer rate. For counterflow
shell and tube heat exchanger with one shell pass is :
−1
1 + 𝑒𝑥𝑝 −𝑁𝑇𝑈 (1 + 𝐶𝑟2 )
ε = 2 1 + 𝐶𝑟 + (1 + 𝐶𝑟2 ) 𝑥
1 − 𝑒𝑥𝑝 −𝑁𝑇𝑈 (1 + 𝐶𝑟2 )
Maximum heat transfer rate is define as follow :

𝑞𝑚𝑎𝑥 = 𝐶𝑚𝑖𝑛 (𝑇ℎ𝑜𝑡 𝑖𝑛 − 𝑇𝑐𝑜𝑙𝑑 𝑖𝑛 )

And relationship between qmax and ε is :


𝑞
ε=
𝑞𝑚𝑎𝑥
`
Effectiveness ε = 1,0

Shell and Tube Effectiveness


1,0 0,96
Cr = 0
0,9
Cr = 0,25
0,8
Cr = 0,5
0,7
Effectiveness (ε)

Cr = 0,75
0,6
Cr = 1
0,5

0,4

0,3

0,2

0,1

0,0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6

Number of Transfer Unit (NTU) Cr = 0,07


Project No. : SSG-RA-G5-2024 Date : 16-Apr-2024
Doc No. : SSG-RA-P5-G5-2024 Prepared by : NFL
Equipment tag : E-201 Checked by : Vegapunk
Project Name :
Shell and Tube Heat Exchanger Rating Calculation Using
Tittle :
Effectiveness-NTU Method
Revision No. 0

Maximum heat transfer rate qmax = 653,6 kW


Actual heat transfer rate q = 624,2 kW

For outlet temperature are calculated with following formula :


𝑞
𝑇ℎ𝑜𝑡 𝑜𝑢𝑡 = 𝑇ℎ𝑜𝑡 𝑖𝑛 −
𝑚ℎ𝑜𝑡 𝐶𝑝ℎ𝑜𝑡
0
Hot fluid outlet temperature T out = 64,9 C

6. RESULTS

0
Hot fluid outlet temperature T out = 64,9 C
0
Log mean temperature ΔT LMTD = 42,6 C
Heat duty Q = 2.113,0 kW