Flowchart Revisi
READY 1 1
Mode Manual Mode Automatic
1
0 0
1
L1 : ON CYCLE ACTIVE
0 0
SS1 RIGHT SS1 LEFT
0
1
CYCLE STOP
1 1
0
All Outputs : OFF All Outputs : OFF
1 1
Mode Manual : ON Mode Manual : OFF Mode Manual : OFF Mode Manual : OFF
Mode Automatic : OFF Mode Automatic : ON Mode Automatic : ON Mode Automatic : ON
PL1 : Blink 1Hz PL1 : OFF PL1 : OFF PL1 : OFF
PL2 : OFF PL2 : Blink 0,5 Hz PL2 : ON PL2 : Blink 0,5 Hz
MODE-MANUAL MODE-AUTOMATIC
MODE-MANUAL
1 1 1
HMI_Button (B2) HMI_Button (B3) HMI_Button (B3)
0 0 0
0 0 0
HMI_Button (B1) HMI_Button (CW) HMI_Button(CCW)
1 1 1
0 0 0
MA1(CW) MA2(CW) MA2(CCW)
1 1 1
MA2(CW) : ON MA2(CCW) : ON
MA1(CW) : ON
MA2(CCW) : OFF MA2(CW) : OFF
MODE-MANUAL
0 0 0 0
S1 S12 S2 S22
1 1 1 1
0
HMI_Button (P1) 0
HMI_Button (P2)
0 0
4s 4s
1 1
1
1
A MA1(CW) : ON
Siklus : Aktif ALL OUTPUTS : OFF
SIKLUS : RESET
MA2(CW) : ON MA2(CCW) : ON
0
S1
0 0
LS1 LS2
1
1 1
MA1(CW) : OFF
TON : ON 0
2s
A
0
1 2s
SL1 : ON 1
SL2 : OFF
SL1 : ON
0
4s
0
1 4s
GR1 : ON 1
GR1 : OFF
GR2 : ON
0
2s
0
1 2s
SL1 : OFF 1
SL2 : ON
SL1 : OFF
SL2 : ON