Scale parameters and functions

6.15 DR 14 SIMATIC interface parameters

6.14.9 Modbus RTU message frame delay


These parameters specify the delay time (in ms) expected by the module replying to a
master request for data.

6.15 DR 14 SIMATIC interface parameters

6.15.1 Overview
The parameters which define the response of the SIMATIC interface are specified in data
record DR 14. It is possible to define the process values to be output on the basis of the I/O
area.

Procedure
● Check the parameters and modify them as required
● Transfer the data record to the scales

Table 6- 12 Assignment of data record 14

Variable Note Type Length RW Default Min. Max. Modbus


(bytes) registers
Data record Contains no. of USHORT 2 r 14 - - 1570
number data record
Length Data record USHORT 2 r 16 - - 1571
length infor-
mation
Application Information USHORT 2 r 141 - - 1572
about which
application the
DR belongs to
Version ID Information USHORT 2 r 1 1 65635 1573
about the current
data record ver-
sion
Selection of Selection of USHORT 2 rw 4 0 10 1574
process value process value 1
1, 2 (S7 I/O inter-
(Page 105) face): Code for
selection of pro-
cess variable to
be updated

SIWAREX WP521/WP522
104 Manual, 04/2016, A5E36695225A