TeSys Enclosed Starters

Let TeSys watch over


your machinery
Standard offer applications:
Fans, blowers, ventilators Pumps: water pumps, heat
pumps, etc. Compressors Elevators Automatic gates,
roof window openers Wood machines: fixed drilling
machines, saws, etc. Tool machines Conveyors

Standard offer
Manual motor starters Starters Switch disconnectors

TeSys GV TeSys LE TeSys Vario

Manual Direct On Line starters Direct On Line or reversing starters 3-pole switch disconnectors
IP55 or IP65 degree of protection IP65 degree of protection IP55 degree of protection
(according to the version)
Functions Functions
Functions >> Protection from overloads (thermal >> Local isolation,
>> Protection from short circuits and relay to be ordered separately) for maintenance
overloads >> Local control >> Padlockable rotary handle
>> Local manual control
>> Emergency stop switch
(special version)
>> Disconnection locking (option)
Check for the presence The motor control
of short-circuit and protection
protection in the main devices are located
electrical switchboard. in the main electrical
switchboard.
Circuit breaker
to be ordered
separately.
Safety offer applications: AS-Interface
Machines whose electrical equipment should comply with IEC 60204
(dangerous machines) offer applications:
Wood machines Metalworking machines Conveyors
Plastics machines Material handling machines,
including conveyors

Safety offer AS-Interface


Manual motor starters

TeSys GV
Safety starters

TeSys LG, LJ
offer
AS-Interface starters

TeSys LF

Manual Direct On Line starters Direct On Line or reversing starters


IP55 degree of protection IP55 degree of protection
Direct On Line or reversing starters
Functions Functions IP54 degree of protection
>> Protection from short circuits >> Protection from short circuits and
and overloads overloads Functions
>> Local manual control >> Protection from voltage drops >> Motor control and monitoring
>> Emergency stop switch (depending on the model, by AS-Interface
(special version) undervoltage release unit to be >> Protection from short circuits
>> Disconnection locking ordered separately) and overloads
>> Emergency stop switch >> Disconnection locking
>> Local manual control >> Local manual control
>> Disconnection locking (special version)

Circuit breaker
to be ordered
separately.
TeSys GV
Manual motor starters

Thermal-magnetic circuit breakers

Motor power AC-3 Max. motor For standard For high performances
400 V current Ie max applications applications
kW References
0.06 0.25 GV2ME02 GV2P02
0.09 0.4 GV2ME03 GV2P03
0.12 0.63 GV2ME04 GV2P04
0.18 0.63 GV2ME04 GV2P04
0.25 1 GV2ME05 GV2P05
0.37 1.6 GV2ME06 GV2P06
0.55 1.6 GV2ME06 GV2P06
0.75 2.5 GV2ME07 GV2P07
1.1 4 GV2ME08 GV2P08
1.5 4 GV2ME08 GV2P08
2.2 6.3 GV2ME10 GV2P10
3 9 GV2ME14 GV2P14
4 9 GV2ME14 GV2P14
5.5 13 GV2ME16 GV2P16
7.5 17 GV2ME20 GV2P20
9 21 GV2ME21 GV2P21
11 23 GV2ME22 GV2P22
15 29 GV3P32
18.5 35 GV3P40
22 41 GV3P50
30 55 GV3P65

Enclosures for GV2ME circuit breakers References


Degree of protection Mushroom head Emergency Stop Surface mounting Flush mounting
IP41 without GV2MC01 GV2MP01
IP55 without GV2MC02 GV2MP02
with - turn to release, padlockable GV2MCK04
IP55 < +5°C without GV2MC03

Enclosures for GV2P/GV3P circuit breakers References


Circuit-breaker Degree of protection Mounting Red Black
GV2P IP65 surface mounting GV2PC01 GV2PC02
GV3P IP65 surface mounting GV3PC01 GV3PC02

Add-on blocks
Description Mounting Voltage References
Undervoltage trips* right side 380…415 V 50 Hz GVAX385
60 Hz GVAX386
*Can be mounted only on GV2ME
TeSys LE
Starters

Enclosed starters Enclosed starters for high-performance applications


Direct Direct Thermal
Motor power Max. motor On Line Motor power Max. motor On Line Reversing overload relays
AC-3 400 V current Ie max starters(1) AC-3 400 V current Ie max starters starters (class 10 A)
kW References kW Ref. Ref. Ref.
0.25 0.8 LE1M35••05 0.06 0.25 LE1D09•• LE2D09•• LRD02
0.09 0.4 LE1D09•• LE2D09•• LRD03
0.37 1.2 LE1M35••06
0.12 0.63 LE1D09•• LE2D09•• LRD04
0.55 1.8 LE1M35••07 0.18 0.63 LE1D09•• LE2D09•• LRD04
0.75 2.6 LE1M35••08 0.25 1 LE1D09•• LE2D09•• LRD05
0.37 1.6 LE1D09•• LE2D09•• LRD06
1.1 3.7 LE1M35••10
0.55 1.6 LE1D09•• LE2D09•• LRD06
1.5 3.7 LE1M35••10 0.75 2.5 LE1D09•• LE2D09•• LRD07
1.1 4 LE1D09•• LE2D09•• LRD08
2.2 5.5 LE1M35••12
1.5 4 LE1D09•• LE2D09•• LRD08
3 8 LE1M35••14 2.2 6 LE1D09•• LE2D09•• LRD10
4 11.5 LE1M35••16 3 7 LE1D09•• LE2D09•• LRD12
4 9 LE1D09•• LE2D09•• LRD14
5.5 14 LE1M35••21
5.5 12 LE1D12•• LE2D12•• LRD16
7.5 16 LE1M35••22 7.5 16 LE1D18•• LE2D18•• LRD21

(1) Thermal relay included 11 22 LE1D25•• LE2D25•• LRD22


15 29 LE1D35•• LE2D35•• LRD32
18.5 40 LE1D40•• LE2D40•• LRD21
22 50 LE1D50•• LE2D50•• LRD22
30 65 LE1D65•• LE2D65•• LRD32

Dots must be replaced by the control circuit voltage code:


Control circuit voltages*
Volts ~ 50/60 Hz 220 230 240 380 400 415
Voltage code LE1M35, LE•D09… D35 M7 P7 U7 Q7 V7 N7
LE•D40A… D65A - P7 - Q7 - -
* Other voltages: please consult our catalogue
TeSys LG, LJ
Safety starters

Enclosed starters
Direct On Line starters Reversing starters
Motor power AC-3 Max. motor Emergency stop by Emergency stop by Emergency stop by
400 V current Ie max switch (rotary handle) mushroom head pushbutton mushroom head pushbutton
kW References
0.06 0.25 LG1K065••02 LG7K06••02 LG8K06••02
0.09 0.4 LG1K065••03 LG7K06••03 LG8K06••03
0.12 0.63 LG1K065••04 LG7K06••04 LG8K06••04
0.18 0.63 LG1K065••04 LG7K06••04 LG8K06••04
0.25 1 LG1K065••05 LG7K06••05 LG8K06••05
0.37 1.6 LG1K065••06 LG7K06••06 LG8K06••06
0.55 1.6 LG1K065••06 LG7K06••06 LG8K06••06
0.75 2.5 LG1K065••07 LG7K06••07 LG8K06••07
1.1 4 LG1K065••08 LG7K06••08 LG8K06••08
1.5 4 LG1K065••08 LG7K06••08 LG8K06••08
2.2 6 LG1K065••10 LG7K06••10 LG8K06••10
3 9 LG1K095••14 LG7K09••14 LG8K09••14
4 9 LG1K095••14 LG7K09••14 LG8K09••14
5.5 12 LG1D122••16 LG7D12••16 LG8D12••16
7.5 17 LG1D182••20 LG7D18••20 -
9 18 LG1D182••21 LG7D18••21 -

Dots must be replaced by the control circuit voltage code:


Control circuit voltages*
Volts ~ 50/60 Hz 220/230 380/400
Voltage code M7 Q7
* Other voltages: please consult our catalogue
TeSys LF TeSys Vario
AS-Interface starters Switch disconnectors

Enclosed starters Enclosed switch disconnectors


Motor power AC-3 Maximum motor Direct On Line Reversing Power AC-23 Thermal References
400 V current Ie max starters starters 400 V current Ithe
kW References kW A

0.06 0.25 LF3P02E LF4P02E 4 10 VCFN12GE


0.09 0.4 LF3P03E LF4P03E 5.5 16 VCFN20GE
0.12 0.63 LF3P04E LF4P04E
7.5 20 VCFN25GE
0.18 0.63 LF3P04E LF4P04E
11 25 VCFN32GE
0.25 1 LF3P05E LF4P05E
0.37 1.6 LF3P06E LF4P06E 15 32 VCFN40GE

0.55 1.6 LF3P06E LF4P06E


0.75 2.5 LF3P07E LF4P07E
1.1 4 LF3P08E LF4P08E
1.5 4 LF3P08E LF4P08E
2.2 6.3 LF3P10E LF4P10E
3 9 LF3P14E LF4P14E
4 9 LF3P14E LF4P14E
5.5 12 LF3P16E LF4P16E

TeSys
enclosed
starters:
Overview
TeSys range: TeSys GV, TeSys GK, TeSys GS, TeSys DF, TeSys K, TeSys D, TeSys F, TeSys B,
TeSys LR, TeSys LT, TeSys T, TeSys Vario, TeSys U, TeSys LE, TeSys LG.

To discover the TeSys range, go to:


www.schneider-electric.com/tesys

To download TeSys Enclosed Motor Starter Solution Guide

Make the most of your energy™


© 2014 - Schneider Electric - All rights reserved

www.schneider-electric.com

Schneider Electric Industries SAS


35, rue Joseph Monier As standards, specifications and designs change
CS 30323 from time to time, please ask for confirmation
F- 92506 Rueil Malmaison Cedex of the information given in this publication.
France

RCS Nanterre 954 503 439 Publication: Schneider Electric Industries SAS This document has been
Capital social 896 313 776 € Photo: © Fotosearch - Schneider Electric Industries SAS printed on ecological paper.
www.schneider-electric.com Printed:

EDCED114012EN 03-2014