Lutron Adaptive Power Module
Lutron Adaptive Power Module
LQSE-4A-D
Hi Temp Opt1 M
Prog Opt2 L
Features
Power Opt3
HomeWorks QS HomeWorks
Power Module QS Panel QS Contact
seeTouch Closure
QS Wallstation Interface GRAFIK
CCI QS Zone 1 Zone 2 Zone 3 Zone 4
Eye QS
COM
COM
MUX
MUX
Zones
CCI
Input
Def H
Z096
Hi Temp 0-10 V Power Module Opt1
Option M
Program LQSE-4T10-D Opt2
230 V~ 50/60 Hz 50 mA µ Up
Power www.lutron.com +44.(0)20.7680.4481 Opt3 L
1,2 N•m
L N 8 mm Mains Only Outputs 230 V~ 10 AX each 1 2 3 4
CCI
Zone 1 Zone 2 Zone 3 Zone 4
Option
DIN Rail Power Module
Input Def H
LQSE-4A-D
Hi Temp Opt1 M
Prog Opt2 L
Power Opt3
® S P E C I F I C AT I O N S U B M I T TA L Page 1
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 2 07.23.18
Specifications
Adaptive Power Module Output Zone Ratings (continued)
• Each zone has no minimum load requirement.
Power
• When programmed to "auto" mode, the unit starts in
• 220–240 V~ 50/60 Hz
trailing edge and if an incompatible load is detected, it
• 10 A maximum total input current will convert to leading edge.
• Lightning strike protection meets ANSI/IEEE standard
• Internal relay provides an air gap off when all zones
62.31-1980. Can withstand voltage surges of up to
are off.
6 000 V and current surges of up to 3 000 A.
• One load type per zone.
Standards • Output must not be used to control receptacles,
• RoHS Compliant including plug-in lamps.
• IEC/EN 60669-2-1 • Output must be directly connected to the load.
• CE marked Output breakers or switches must not be used.
• Lutron Quality Systems registered to ISO 9001.2015 • Run a separate neutral for each load circuit. A
common neutral connection is not recommended.
Environment
• Maximum wire length between the Energi Savr Node
• See Mounting on page 4 for thermal specifications
unit and the load must be less than 30.5 m.
• Relative humidity: less than 90% non-condensing
• Unit may be powered by Ground Fault Interrupter (GFI)
• For indoor use only
or Residual Current Circuit Breaker with Overload
Output Zone Ratings (RCBO) protected circuit if required. Load circuit wiring
(from breaker to unit to load) must be run in its own
• No Derating is required if all the conditions below are met:
non-metallic conduit, or nuisance tripping may occur.
– Calibration point maximum is 70 ºC
– Room ambient temperature is between 0 ºC and 30 ºC • For applications requiring 0–10 V- control, use Ten
– Panel ambient temperature is between 0 ºC and 50 ºC Volt Interface (GRX-TVI) or the LQSE-4T10-D.
• 100 W Derating is required on all zones for a single • For applications requiring higher wattage ratings, use a
module in a single non-ventilated DIN enclosure if: power booster (NGRX-PB, NGRX-ELVI, NGRX-FDBI).
– The room ambient temperature is between
30 ºC and 40 ºC.
• 200 W Derating is required on all zones for multiple
row non-ventilated DIN enclosure if:
–T he room ambient temperature is between 30 ºC and
40 ºC.
Each zone is rated for the following wattage and load typesA, B:
Zone 1 Rating Zone 2, 3 and 4 Rating (per zone)
Load Type 100 W 200 W 100 W 200 W
No Derating Derating Derating No Derating Derating Derating
Incandescent / Halogen 800 W 700 W 600 W 500 W 400 W 300 W
Electronic Low Voltage 800 W 700 W 600 W 500 W 400 W 300 W
Magnetic Low VoltageD 800 VA (600 WC) 700 VA (525 WC) 600 VA (450 WC) 500 VA (375 WC) 400 VA (300 WC) 300 VA (225 WC)
Neon / Cold CathodeD 800 VA (600 WC) 700 VA (525 WC) 600 VA (450 WC) 500 VA (375 WC) 400 VA (300 WC) 300 VA (225 WC)
A
Additional load type options are available in the HomeWorks QS software suite, some may require an interface. Contact Lutron for details.
B
Refer to Lutron P / N 048478 on www.lutron.com for compatibility with dimmable CFL / LED light sources.
C
Actual lamp wattage.
D
Only use iron core transformers intended for use with an electronic switch or dimmer per Clause 8.3 of IEC / EN 60669-2-1
® S P E C I F I C AT I O N S U B M I T TA L Page 2
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 3 07.23.18
® S P E C I F I C AT I O N S U B M I T TA L Page 3
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 4 07.23.18
Mounting
LQSE-4A-D
breaker panel with integrated DIN rail.
Hi Temp Opt1 M
Prog Opt2 L
Power Opt3
Mechanical Dimensions
Left Side View Front View
Calibration
point 800 W Max 500 W Max 500 W Max 500 W Max
CCI
Zone 1 Zone 2 Zone 3 Zone 4
90 mm
90 mm
Option
DIN Rail Power Module
Input Def H
LQSE-4A-D
Hi Temp Opt1 M
Prog Opt2 L
Power Opt3
55 mm 216 mm
70 mm
76 mm
® S P E C I F I C AT I O N S U B M I T TA L Page 4
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 5 07.23.18
CCI
Zone 1 Zone 2 Zone 3 Zone 4
Option
DIN Rail Power Module
Input Def H
LQSE-4A-D
Hi Temp Opt1 M
Prog Opt2 L
Power Opt3
® S P E C I F I C AT I O N S U B M I T TA L Page 5
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 6 07.23.18
Verify Wiring
LQSE-4A-D
• Unit ships with bypass connector pre-installed for load • To verify wiring:
wiring verification. Bypass connector is used to apply 1. Turn off power.
power to loads to identify any load or wiring faults prior 2. Wire loads to provided connector.
to wiring loads to unit. 3. Apply power, ensure the desired loads are
• Load wiring must be verified before wiring loads to unit. powered and properly wired.
4. Turn off power and wire loads to DL terminals
on unit.
CCI
Zone 1 Zone 2 Zone 3 Zone 4
Option
DIN Rail Power Module
Input Def H
LQSE-4A-D
Hi Temp Opt1 M
Prog Opt2 L
Power Opt3
c
Earth
Distribution
b
Panel
Live
(220–240 V~)
Neutral
® S P E C I F I C AT I O N S U B M I T TA L Page 6
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 7 07.23.18
CCI
Zone 1 Zone 2 Zone 3 Zone 4
Option
DIN Rail Power Module
Input Def H
LQSE-4A-D
Hi Temp Opt1 M
Prog Opt2 L
800
PowerW Max 500 W Max
Opt3
500 W Max 500 W Max
230 V~ 50 / 60 Hz 10 A www.lutron.com +44.(0)20.7702.0657
CCI
Zone 1 Zone 2 Zone 3 Zone 4
Option
DIN Rail Power Module
Def H
LQSE-4A-D
Opt1 M
Zone 1 Example
Opt2 L
Opt3
0 / 60 Hz 10 A www.lutron.com +44.(0)20.7702.0657
Dim Live
Earth
Distribution (220-240 V~)
Panel Live
Neutral Load
(220–240 V~) Neutral
® S P E C I F I C AT I O N S U B M I T TA L Page 7
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 8 07.23.18
Wiring: Emergency Contact Closure IEC PELV Emergency Contact Closure Input
Input • Contact Closure Input (CCI) wiring is
IEC PELV / NEC® Class 2.
Follow all applicable national and local codes for
Input
800
800 W
W Max
Max 500
500WWMax
Max 500
500WWMax
Max 500
500W
WMax
Max
proper circuit separation and protection.
S1 S2 S3 S4 CCI
CCI Zone 11 Zone
Zone 22 Zone
Zone 33 Zone
Zone44
Input
Input Def
Def HH
QSNE-4A-D
Hi T
Hi Temp
emp Opt1
Opt1 M
M
RailPower
Prog
Prog Opt2
Opt2 LL
DINRail
Power
Power Opt3
230 V~
230 V~ 50
50 // 60
60 Hz
Hz 10
10 A
A www.lutron.com +44.(0)20.7702.0657
www.lutron.com +44.(0)20.7702.0657
Opt3
www.lutron.com +44.(0)20.7702.0657
)Lutron, Lutron, HomeWorks, RTISS Equipped, GRAFIK Eye, seeTouch, and Quantum are registered trademarks of Lutron Electronics Co., Inc. registered in the U.S. and other countries.
RTISS-TE, Energi Savr Node are trademarks of Lutron Electronics Co., Inc.
® S P E C I F I C AT I O N S U B M I T TA L Page 8
Job Name: Model Numbers:
Job Number:
Adaptive Power Module HomeWorks QS Phase Adaptive Fixture Controller
369583f 9 07.23.18
Wiring: QS Link
QS Link IEC PELV Wiring
Option
DIN Rail Power Module
Hi Temp Opt1 M
Prog Opt2 L
(3) MUX
(4) MUX
H
02.0657
1
QSE-CI-DMX nit does not consume or supply PDUs on
U
the QS link. Do not connect the 24 V- wire
to unit.
Note: 24 V- wire must bypass the unit if other
devices on the link consume PDUs.
® S P E C I F I C AT I O N S U B M I T TA L Page 9
Job Name: Model Numbers:
Job Number: