OIL ANALYSIS REPORT


1638 CONTAMINANTS SPECIFICATIONS
M/s. MINIMAC SYSTEM PRIVATE LIMITED
SITE NAME : DVC MEJIA THERMAL POWER STATION
LUBRICANT CONDITION : NORMAL
LUBRICANT USABILITY : OK

SLIDE No./ VISIT No. S1V1 REPORT DATE 21.03.2024


DEPARTMENT TMS-7&8 SAMPLE DATE 14.03.2024
EQUIPMENT MOT # 7 RECEIVED DATE 19.03.2024
SUMP CAPACITY 40000 Ltr. OIL GRADE SP-46
--
Particl Count Per 100 ml
SIZES NO. OF CONTAMINATION Unit
>5um 25136 Micron

>15um 3465 Micron

>25um 1507 Micron

>50um 167 Micron

> 100um 11 Micron

17/15/12 NORMAL LIMIT : ≤ 18/16/13


OIL CLEANLINESS : NORMAL ISO 4406
NAS CLASS-6 NAS CLASS - 7

REMARKS : Through particle quantifier, contamination level has been found NAS class 6.
Oil is fit for further use.

NAS TREND
10
9
8
7
6
NAS CLASS

5
4
3
2
1
0
VISIT V1

OIL ANALYSIS REPORT


Physio-Chemical Properties
Minimum Maximum ASTM
TEST PARAMETER : Test Value Result
Limit Limit Method
MOISTURE IN PPM : 135 NORMAL 500 D 1744

Prepared By:Rose Mala Bilung Checked By:Mani Tirkey