Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Version 7.4.

PVsyst classroom
PVsyst - Simulation report
Standalone system

Project: Paradero Solar


Variant: Nueva variante de simulación
Standalone system with batteries

PVsyst classroom
System power: 455 Wp
Moquegua - Perú

PVsyst classroom

PVsyst classroom
Autor(a)
Ingeniería y Energía INEL (Peru)

PVsyst classroom
Project: Paradero Solar
Variant: Nueva variante de simulación

PVsyst V7.4.5 Ingeniería y Energía INEL (Peru)


VC0, Simulation date:
24/02/24 22:43

PVsyst classroom
with v7.4.5

Project summary
Geographical Site Situation Project settings
Moquegua Latitude -17.20 °S Albedo 0.20
Perú Longitude -70.92 °W
Altitude 1531 m
Time zone UTC-5

Meteo data
Moquegua
NREL NSRDB Typ. Met. Year PSMv3_1998 to 2020 - TMY

System summary

PVsyst classroom
Standalone system

PV Field Orientation
Fixed plane
Tilt/Azimuth 30 / 0 °
Standalone system with batteries

User's needs
Daily household consumers
Constant over the year
Average 2.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 1 unit Technology Lead-acid, sealed, AGM
Pnom total 455 Wp Nb. of units 2 units
Voltage 12 V
Capacity 478 Ah

Results summary

PVsyst classroom
Useful energy from solar 720.51 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
221.57 kWh/year
Specific production 1584 kWh/kWp/year Perf. Ratio PR
Available solar energy 1004.31 kWh/year

Table of contents
Solar Fraction SF
61.03 %
100.00 %

Project and results summary 2


General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst classroom

PVsyst classroom
24/02/24 PVsyst Classroom License, Ingeniería y Energía INEL (Peru) Page 2/7
Project: Paradero Solar
Variant: Nueva variante de simulación

PVsyst V7.4.5 Ingeniería y Energía INEL (Peru)


VC0, Simulation date:
24/02/24 22:43

PVsyst classroom
with v7.4.5

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Imported
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 2.0 kWh/Day

PVsyst classroom
PV module
Manufacturer
Model
PV Array Characteristics

Generic
JAM72-S20-455-MR
Battery
Manufacturer
Model
Generic
PVX-2580L
(Original PVsyst database) Technology Lead-acid, sealed, AGM
Unit Nom. Power 455 Wp Nb. of units 2 in parallel
Number of PV modules 1 unit Discharging min. SOC 20.0 %
Nominal (STC) 455 Wp Stored energy 4.6 kWh
Modules 1 strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 12 V
Pmpp 417 Wp Nominal Capacity 478 Ah (C10)
U mpp 38 V Temperature Fixed 20 °C

PVsyst classroom
I mpp 11 A

Controller Battery Management control


Manufacturer Generic Threshold commands as SOC calculation
Model SmartSolar MPPT 150/35 12V Charging SOC = 0.95 / 0.75
Technology MPPT converter approx. 14.3 / 12.5 V
Temp coeff. -2.7 mV/°C/Elem. Discharging SOC = 0.20 / 0.45
Converter approx. 11.8 / 12.2 V
Maxi and EURO efficiencies 98.0 / 96.0 %

Total PV power
Nominal (STC) 0.455 kWp
Total 1 modules
Module area 2.2 m²

PVsyst classroom
Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 58 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 1.7 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module Quality Loss Module mismatch losses


Loss Fraction -0.8 % Loss Fraction 0.0 % at MPP

IAM loss factor


Incidence effect (IAM): User defined profile

0° 30° 50° 65° 70° 75° 80° 85° 90°


1.000 1.000 0.992 0.943 0.898 0.813 0.677 0.426 0.000

PVsyst classroom
24/02/24 PVsyst Classroom License, Ingeniería y Energía INEL (Peru) Page 3/7
Project: Paradero Solar
Variant: Nueva variante de simulación

PVsyst V7.4.5 Ingeniería y Energía INEL (Peru)


VC0, Simulation date:
24/02/24 22:43

PVsyst classroom
with v7.4.5

Detailed User's needs


Daily household consumers, Constant over the year, average = 2.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Lámparas (LED o fluo) 5 30/lamp 13.0 1950
Consumidores en espera 24.0 24
Total daily energy 1974

PVsyst classroom

PVsyst classroom

PVsyst classroom

PVsyst classroom
24/02/24 PVsyst Classroom License, Ingeniería y Energía INEL (Peru) Page 4/7
Project: Paradero Solar
Variant: Nueva variante de simulación

PVsyst V7.4.5 Ingeniería y Energía INEL (Peru)


VC0, Simulation date:
24/02/24 22:43

PVsyst classroom
with v7.4.5

Main results
System Production
Useful energy from solar 720.51 kWh/year Perf. Ratio PR 61.03 %
Available solar energy 1004.31 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 221.57 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 85.9 %
Missing Energy 0.00 kWh/year Static SOW 80.0 %
Battery lifetime 5.0 years

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst classroom

PVsyst classroom
January
GlobHor
kWh/m²
220.5
GlobEff
kWh/m²
179.7
Balances and main results

E_Avail
kWh
70.93
EUnused
kWh
4.64
E_Miss
kWh
0.000
E_User
kWh
61.19
E_Load
kWh
61.19
SolFrac
ratio
1.000
February 184.8 164.9 64.74 5.80 0.000 55.27 55.27 1.000
March 202.9 204.6 79.85 13.70 0.000 61.19 61.19 1.000
April 194.0 223.4 87.32 22.81 0.000 59.22 59.22 1.000
May 176.2 227.5 89.76 23.09 0.000 61.19 61.19 1.000
June 159.4 218.3 86.45 21.58 0.000 59.22 59.22 1.000
July 173.2 230.8 91.09 24.01 0.000 61.19 61.19 1.000
August 195.1 235.5 92.62 25.81 0.000 61.19 61.19 1.000
September 218.0 231.6 90.79 26.35 0.000 59.22 59.22 1.000
October 249.5 230.6 90.70 24.39 0.000 61.19 61.19 1.000

PVsyst classroom
November
December
Year
252.1
254.1
2479.9
206.7
197.5
2551.2
81.61
78.45
1004.31
17.06
12.34
221.57
0.000
0.000
0.000
59.22
61.19
720.51
59.22
61.19
720.51
1.000
1.000
1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst classroom
24/02/24 PVsyst Classroom License, Ingeniería y Energía INEL (Peru) Page 5/7
Project: Paradero Solar
Variant: Nueva variante de simulación

PVsyst V7.4.5 Ingeniería y Energía INEL (Peru)


VC0, Simulation date:
24/02/24 22:43

PVsyst classroom
with v7.4.5

Loss diagram
2480 kWh/m² Global horizontal irradiation
+4.6% Global incident in coll. plane

-1.68% IAM factor on global

2551 kWh/m² * 2 m² coll. Effective irradiation on collectors

efficiency at STC = 20.48% PV conversion

1161 kWh Array nominal energy (at STC effic.)

PVsyst classroom
-0.55% PV loss due to irradiance level

-8.69% PV loss due to temperature

+0.75% Module quality loss

0.00% Module array mismatch loss

-3.15% Ohmic wiring loss

-21.54% Unused energy (battery full)

807 kWh Effective energy at the output of the array

PVsyst classroom
-3.00% Converter Loss during operation (efficiency)
-0.01% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
0.00% Converter Loss due to voltage threshold
783 kWh Converter losses (effic, overload)
Battery Storage
Direct use Stored +0.19% Battery Stored Energy balance
1.6% 98.4%

-3.09% Battery efficiency loss

-2.82% Charge/Disch. Current Efficiency Loss


-0.82% Gassing Current (electrolyte dissociation)
-0.08% Battery Self-discharge Current

PVsyst classroom 721 kWh


721 kWh

721 kWh
Energy from the sun
Energy supplied to the user

Energy need of the user (Load)

PVsyst classroom
24/02/24 PVsyst Classroom License, Ingeniería y Energía INEL (Peru) Page 6/7
Project: Paradero Solar
Variant: Nueva variante de simulación

PVsyst V7.4.5 Ingeniería y Energía INEL (Peru)


VC0, Simulation date:
24/02/24 22:43

PVsyst classroom
with v7.4.5

Predef. graphs
Diagrama entrada/salida diaria

PVsyst classroom

PVsyst classroom

PVsyst classroom

PVsyst classroom
24/02/24 PVsyst Classroom License, Ingeniería y Energía INEL (Peru) Page 7/7