Multi-Network Combiner: Product Code: PW-SMOC-10I4O-A
Multi-Network Combiner: Product Code: PW-SMOC-10I4O-A
Multi-Network Combiner
CDMA800 or GSM900
CDMA800 or GSM900
UMTS2100 BTS
GSM1800 BTS
UMTS2100 BTS
GSM1800 BTS
4 UMTS2100 Base Tranceiver Station It combine RF Signal from BTS to 4 antenna ports or split the signal to 10 BTS in the Receiving direction. This is a highly important function when designing shared antenna system wishing to connect multiple RBSs to the shared antenna.
Electrical Specification
Product Code Passband - Input port : Port 1, 2 : CDMA800-GSM900 806 - 960Mhz 1710 - 1880Mhz 1920 - 2170Mhz 4 Port (ANT1 to ANT4) < 1.5dB < 6.5dB < 6.5dB < 6.5dB >18dB > 80 dB > 80 dB > 80 dB > 20 dB < -140dBc 100watt 50 Ohm Port 5, 6, 7, 8 : GSM1800 Port 9,10,11,12 : UMTS2100 Number of Output Port Insertion Loss : Coupling Loss : Port 1,2,3,4 : CDMA800 to ANT 1-4 Port 5,6,7,8 : GSM1800 to ANT 1-4 Port 9,10,11,12: UMTS2100 to ANT 1-4 Input Return Loss Isolation between system : CDMA800 & GSM900 Vs GSM1800 CDMA800 & GSM900 Vs UMTS2100 GSM1800 Vs UMTS2100 Isolation between same system Inter-modulation 2 x +43dB Maximum input power/port Impedance in/out PW-SMOC-10I4O-A
Mechanical Specification
Dimension (WxLxD) Weight (Max) : Connector for input & output Connector for Monitoring Port 41x39x23 cm <20 Kg N-female N-female or SMA-female
Environmental Specification
Temperature Range (normal operation) Ingress Protection Class Humidity -30 to +65 0C IP40 for Indoor Relative 5-100%
Factory reserves the right to change product specification at any time (if found necessary). Customer should provide Band Pass Filter between CDMA 800Mhz & GSM 900Mhz if both frequency are used together.
Multi-Operator Combiner
CDMA800 or GSM900
CDMA800 or GSM900
UMTS2100 BTS
GSM1800 BTS
UMTS2100 BTS
GSM1800 BTS
5 UMTS2100 Base Tranceiver Station It combine RF Signal from BTS to 4 antenna ports or split the signal to 12 BTS in the Receiving direction. This is a highly important function when designing shared antenna system wishing to connect multiple RBSs to the shared antenna.
Electrical Specification
Product Code Passband - Input port : Port 1,2 : CDMA800-GSM900 Port 3, 4, 5, 6, 7 : GSM1800 Port 8,9,10,11,12 : UMTS2100 Number of Output Port Insertion Loss : Coupling Loss : Port 1,2 :CDMA800/GSM900 to ANT 1-4 < 6dB Port 3,4,5, : GSM1800 to ANT 1-4 Port 6,7 : GSM1800 to ANT 1-4 Port 8,9,10 : UMTS2100 to ANT 1-4 Port 11, 12 : UMTS2100 to ANT 1-4 Input Return Loss Isolation between system : CDMA800, GSM900 Vs GSM1800 CDMA800, GSM900 Vs UMTS2100 GSM1800 Vs UMTS2100 Isolation between same system Inter-modulation 2 x +43dB Maximum input power/port Impedance in/out > 80 dB > 80 dB > 80 dB >23 dB < -140dBc 100watt 50 Ohm < 6dB < 9dB < 6dB < 9dB >18dB 806 - 960Mhz 1710 - 1880Mhz 1920 - 2170Mhz 4 Port (ANT1 to ANT4) < 1.2dB PW-SMOC-12I4O-A
Mechanical Specification
Dimension (WxLxD) Weight (Max) : Connector for input & output Connector for Monitoring Port 41x39x23 cm < 21Kg N-female N-female or SMA-female
Environmental Specification
Temperature Range (normal operation) Ingress Protection Class -30 to +65 0C IP40 for Indoor
Factory reserves the right to change product specification at any time (if found necessary). Customer should provide Band Pass Filter between CDMA 800Mhz & GSM 900Mhz if both frequency are used together.
Multi-Operator Combiner
CDMA800 or GSM900
CDMA800 or GSM900
UMTS2100 BTS
GSM1800 BTS
UMTS2100 BTS
GSM1800 BTS
4 UMTS2100 Base Tranceiver Station It combine RF Signal from BTS to 4 antenna ports or split the signal to 12 BTS in the Receiving direction. This is a highly important function when designing shared antenna system wishing to connect multiple RBSs to the shared antenna.
Electrical Specification
Product Code Passband - Input port : Port 1, 2, 3, 4 : CDMA800-GSM900 Port 5, 6, 7, 8 : GSM1800 Port 9,10,11,12 : UMTS2100 Number of Output Port Insertion Loss : Coupling Loss : Port 1,2,3,4 : CDMA800 to ANT 1-4 Port 5,6,7,8 : GSM1800 to ANT 1-4 Port 9,10,11,12: UMTS2100 to ANT 1-4 Input Return Loss Isolation between system : CDMA800 & GSM900 Vs GSM1800 CDMA800 & GSM900 Vs UMTS2100 GSM1800 Vs UMTS2100 Isolation between same system Inter-modulation 2 x +43dB Maximum input power/port Impedance in/out > 80 dB > 80 dB > 80 dB >20 dB < -140dBc 100watt 50 Ohm < 6.5dB < 6.5dB < 6.5dB >18dB 806 - 960Mhz 1710 - 1880Mhz 1920 - 2170Mhz 4 Port (ANT1 to ANT4) < 1.5dB PW-SMOC-12I4O-B
Mechanical Specification
Dimension (WxLxD) Weight (Max) : Connector for input & output Connector for Monitoring Port To be Advise <18Kg N-female N-female or SMA-female
Environmental Specification
Temperature Range (normal operation) Ingress Protection Class Humidity -30 to +65 0C IP40 for Indoor Relative 5-100%
Factory reserves the right to change product specification at any time (if found necessary). Customer should provide Band Pass Filter between CDMA 800Mhz & GSM 900Mhz if both frequency are used together.
Multi-Operator Combiner
CDMA800 or GSM900
CDMA800 or GSM900
UMTS2100 BTS
GSM1800 BTS
UMTS2100 BTS
GSM1800 BTS
split the signal to 13 BTS in the Receiving direction. This is a highly important function when designing
Electrical Specification
Product Code Passband - Input port : Port 1,2 : CDMA800-GSM900 Port 3, 4, 5, 6, 7 : GSM1800 Port 8,9,10,11,12 : UMTS2100 Port 13 : WiMax-2300 Number of Output Port Insertion Loss : Port 1,2 :CDMA800/GSM900 to ANT 1-4 Port 3,4,5, : GSM1800 to ANT 1-4 Port 6,7 : GSM1800 to ANT 1-4 Port 8,9,10 : UMTS2100 to ANT 1-4 Port 11, 12 : UMTS2100 to ANT 1-4 Port 13 : Wimax 2300 to ANT 1-4 Return Loss Isolation between same system Isolation between system : Inter-modulation (2 x +43dB) Maximum input power/port Impedance in/out PW-SMOC-13I4O-A 806 - 960Mhz 1710 - 1880Mhz 1920 - 2170Mhz 2300 2390 Mhz 4 Port (ANT1 to ANT4) < 8 dB < 8 dB < 11,5 dB < 8 dB < 11,5 dB < 8 dB >18dB >21 dB > 80 dB < -140dBc 100watt 50 Ohm
Mechanical Specification
Dimension (WxLxD) Weight (Max) : Connector for Monitoring Port Connector for input & output 482.6x426.5x400mm <30Kg N-female or SMA-female N-female or DIN-female
Environmental Specification
Temperature Range (normal operation) Ingress Protection Class Humidity -30 to +65 0C IP40 for Indoor Relative 5-100%
Note : Factory reserves the right to change product specification at any time (if found necessary). Customer should provide Band Pass Filter between CDMA 800Mhz & GSM 900Mhz if both frequency are used together.
Multi-Operator Combiner
CDMA800 or GSM900
CDMA800 or GSM900
UMTS2100 BTS
GSM1800 BTS
UMTS2100 BTS
GSM1800 BTS
5 GSM1800 Base Tranceiver Station 5 UMTS2100 Base Tranceiver Station 1 WiFi 2400 Access Point Station It combine RF Signal from BTS to 4 antenna ports or split the signal to 13 BTS in the Receiving direction. This is a highly important function when designing shared antenna system wishing to connect multiple RBSs to the shared antenna.
Electrical Specification
Product Code Passband - Input port : Port 1,2 : CDMA800-GSM900 Port 3, 4, 5, 6, 7 : GSM1800 Port 8,9,10,11,12 : UMTS2100 Port 13 : WiFi - 2400 Number of Output Port Insertion Loss : Port 1,2 :CDMA800/GSM900 to ANT 1-4 Port 3,4,5, : GSM1800 to ANT 1-4 Port 6,7 : GSM1800 to ANT 1-4 Port 8,9,10 : UMTS2100 to ANT 1-4 Port 11, 12 : UMTS2100 to ANT 1-4 Port 13 : WiFi 2400 to ANT 1-4 Return Loss Isolation between same system Isolation between system : Inter-modulation (2 x +43dB) Maximum input power/port Impedance in/out PW-SMOC-13I4O-B 806 - 960Mhz 1710 - 1880Mhz 1920 - 2170Mhz 2400 2500 Mhz 4 Port (ANT1 to ANT4) < 8 dB < 8 dB < 11,5 dB < 8 dB < 11,5 dB < 9 dB >18dB >21 dB > 80 dB < -140dBc 100watt 50 Ohm
Mechanical Specification
Dimension (WxLxD) Weight (Max) : Connector for Monitoring Port Connector for input & output 482.6x426.5x400mm <30Kg N-female or SMA-female N-female or DIN-female
Environmental Specification
Temperature Range (normal operation) Ingress Protection Class Humidity -30 to +65 0C IP40 for Indoor Relative 5-100%
Note : Factory reserves the right to change product specification at any time (if found necessary). Customer should provide Band Pass Filter between CDMA 800Mhz & GSM 900Mhz if both frequency are used together.
Multi-Operator Combiner
CDMA800 or GSM900
CDMA800 or GSM900
UMTS2100 BTS
GSM1800 BTS
UMTS2100 BTS
GSM1800 BTS
5 UMTS2100 Base Tranceiver Station It combine RF Signal from BTS to 4 antenna ports or split the signal to 14 BTS in the Receiving direction. This is a highly important function when designing shared antenna system wishing to connect multiple RBSs to the shared antenna.
Electrical Specification
Product Code Passband - Input port : Port 1, 2, 3, 4 Port 5, 6, 7, 8, 9 : CDMA800-GSM900 : GSM1800 806 - 960Mhz 1710 - 1880Mhz 1920 - 2170Mhz 4 Port (ANT1 to ANT4) < 1.2dB PW-SMOC-14I4O-A
Port 10,11,12,13,14 : UMTS2100 Number of Output Port Insertion Loss : Coupling Loss :
Port 1,2,3,4 :CDMA800/GSM900 to ANT 1-4 < 6dB Port 5,6,7 Port 8, 9 : GSM1800 to ANT 1-4 : GSM1800 to ANT 1-4 < 6dB < 9dB < 6dB < 9dB >18dB > 80 dB > 80 dB > 80 dB >23 dB < -140dBc 100watt 50 Ohm
Port 10,11,12 : UMTS2100 to ANT 1-4 Port 13, 14 : UMTS2100 to ANT 1-4 Input Return Loss Isolation between system : CDMA800 & GSM900 Vs GSM1800 CDMA800 & GSM900 Vs UMTS2100 GSM1800 Vs UMTS2100 Isolation between same system Inter-modulation 2 x +43dB Maximum input power/port Impedance in/out
Mechanical Specification
Dimension (WxLxD) Weight (Max) : Connector for input & output Connector for Monitoring Port (-30dB) To be Advise <22Kg N-female N-female or SMA-female
Environmental Specification
Temperature Range (normal operation) Ingress Protection Class -30 to +65 0C IP40 for Indoor
Factory reserves the right to change product specification at any time (if found necessary). Customer should provide Band Pass Filter between CDMA 800Mhz & GSM 900Mhz if both frequency are used together.
Multi-Operator Combiner
CDMA800 or GSM900
CDMA800 or GSM900
UMTS2100 BTS
GSM1800 BTS
UMTS2100 BTS
GSM1800 BTS
1 WiFi Access Point 1 WiMax Base Tranceiver Station It combine RF Signal from BTS to 4 antenna ports or split the signal to 14 BTS in the Receiving direction. This is a highly important function when designing shared antenna system wishing to connect multiple RBSs to the shared antenna.
Electrical Specification
Product Code Frequency Range - Input port : Port 1,2 : CDMA800-GSM900 Port 3, 4, 5, 6, 7 : GSM1800 Port 8,9,10,11,12 : UMTS2100 Port 13 : WiMax-2300 Port 14 : WiFi-2400 Number of Output Port Insertion Loss : Port 1,2 :CDMA800/GSM900 to ANT 1-4 Port 3,4,5, : GSM1800 to ANT 1-4 Port 6,7 : GSM1800 to ANT 1-4 Port 8,9,10 : UMTS2100 to ANT 1-4 Port 11, 12 : UMTS2100 to ANT 1-4 Port 13 : Wimax 2300 to ANT 1-4 Port 14 : WiFi 2400 to ANT 1-4 Return Loss Isolation between same system Isolation between system : Port 1,2 Vs Port 3,4,5,6,7,8,9,10,11,12,13,14 Port 3,4,5,6,7 Vs Port 1,2,8,9,10,11,12,13,14 Port 8,9,10,11,12 Vs Port 1,2,3,4,5,6,7,13,14 Port 13 Vs Port 1,2,3,4,5,6,7,8,9,10,11,12 Port 14 Vs Port 1,2,3,4,5,6,7,8,9,10,11,12 Port 13 Vs Port 14 Inter-modulation (2 x +43dB) Maximum input power/port Impedance in/out > 80 dB > 80 dB > 80 dB > 80 dB > 80 dB > 50 dB < -140dBc 100watt 50 Ohm 482.6x426.5x400mm <30Kg N-female or SMA-female N-female or DIN-female -30 to +65 0C IP40 for Indoor Relative 5-100% PW-SMOC-14I4O-A 806 - 960Mhz 1710 - 1880Mhz 1920 - 2170Mhz 2300 - 2390 Mhz 2400 - 2500 Mhz 4 Port (ANT1 to ANT4) < 8 dB < 8 dB < 11,5 dB < 8 dB < 11,5 dB < 9 dB < 9 dB >18dB >21 dB
Mechanical Specification
Dimension (WxLxD) Weight (Max) : Connector for Monitoring Port Connector for input & output
Environmental Specification
Temperature Range (normal operation) Ingress Protection Class Humidity