LS ELS (Conductivity Type)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Good bye to age old float operated

Level switches…
The Nano is here…

ELS NANO
SINGLE POINT ELECTRONIC LEVEL SWITCH
For Steam / water interfaces
Reliable detection of water/steam level is essential for the safe operation of any water containing
device. Very high level may lead to an overflow whereas very low level may cause overheating
resulting in damage to collateral equipments as well.

Levelstate Electronic Level Switch (ELS) Nano provides a reliable and cost effective means of sensing
water/steam level in high pressure applications. ELS Nano is based on the conductivity probe principle
where resistivityy discrimination between water and steam is used to p
provide the required
q indication.

Levelstate ELS Nano is an effective and economical replacement to the float type level switch.

The system consists of an electronic unit, a conductivity probe, a probe insert/standpipe and a length of
probe cable. The conductivity probe can be mounted directly on the vessel through a probe insert or a
side arm standpipe.

Features of ELS Nano Applications

9Single point water/steam level detection 9Equipment drains (Desuperheaters, Control valves,
9Ideal for economic replacement of float type Soot blower systems)
level switches 9Receiver tanks (Condenser, Water tank, Deaerator)
9Both horizontal and vertical configurations 9Flash tanks, Feed water heaters
available 9Steam line drain pots
9Visual indication (LED) 9Mainstream header drains
9Universal power input supply 9Hot and cold reheat drains
9Adjustable time delay output 9Turbine water intrusion protection (TWIP)
9Available for pressure ratings upto 207 bar 9High pressure systems, where float type level
(3000 psi) switches are not feasible
9Explosion proof (optional)

ELS Nano advantages over Float Type Approvals


Level Switch
¾Quality system accredited to ISO 9001
¾No moving parts ¾Design approval of pressure parts, operational
¾No calibrations required and field testing of the system
¾Direct reading ¾Third party inspection, testing and certification
¾Avoid any nuisance alarm / trip by approved international agencies
¾Easier installation ¾Certification of explosion proof to international
¾Fit and forget standard for use in hazardous area
¾Reliable service for much longer period
¾Much more user friendly
TECHNICAL SPECIFICATIONS Electronic Unit:
Enclosure - Wall mounted glass-fibre reinforced polyester.
Protection : IP65/NEMA 4X.
Dims: 154H x 200W x 76D.
Inputs - Discrimination between water and steam/vacuum/no
water using conductivity probes. Switching threshold selected
for water conductivities of 0.5, 1 or 2microS/cm.
Outputs – Two pole change over contact. Selection for Relays
in either energized or de-energized condition.
Time delay settings to avoid nuisance trip
On delay 0 – 6 Sec and Off delay 0 – 63 sec
Contact Rating: Max Voltage - 250Vac, 220Vdc
Max Current - 8Amps
Load Switching - 240W / 2000 VA.
Display: Green / Red LED indication for normal water / steam
status respectively. Respective LED flash on process fault
condition.
Power Supply -
The system uses a single AC/DC SMPS source:
85 – 264 V AC @ 15VA, 48 - 63Hz
120 - 370V DC @ 25W
Temperature Rating: -10 to 65 °C Amb.
Conductivity Probes : -50 to 100 °C Storage.

Type : 801 802 Type 801


Rated pressure / : 150 bar (2176 psi) @ 207 bar (3000 psi) @
temperature saturated temperature saturated temperature
Material : SS with zirconia insulator SS with zirconia insulator
Connection type : Screwed type with M16 x Swagelok type with metal to
1.5mm thread and metal seal, compression
metaflex gasket seal fitted
Option : Probe Type 811 with non- Probe Type 812 with non- Type 802
wetting insulator available wetting insulator available
for pressure upto 23 bar for pressure upto 23 bar
(334 psi) @ saturated (334 psi) @ saturated
temperature temperature

Stand pipe :
Type : 501 (for Type 801/811 Probe) 502 (for Type 802/812 Probe)
Material : Carbon steel to ASTM A 106 Carbon steel to ASTM A 106
Design code : ASME B 31.1 Power Piping ASME B 31.1 Power Piping Code
Code / IBR / IBR
Steam & water : 25 NB SW Sch.160
25 NB SW Sch.160
connection
Drain connection : 15 NB SW Sch.80 15 NB SW Sch.80

Probe Insert Assembly : Probe Cable –Type Nano28-10:


Used for direct probe installation on to the PTFE insulated high temperature 4 – core cable of
existing vessel or stand pipe
pipe. Type 701 is used standard 10 m length provided for connecting probes
with Type 801 / 811 probes and Type 702 is to ELS Nano electronic unit
used with Type 802 / 812 probes.
System Cabling Diagram Electronic unit GA drawing

You might also like