Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

ETAP Training

100+ Hours of live cohort - Base course on Power System Studies

Every electrical engineer wants to learn Power system studies at some point for the
career growth, many are not sure about how to get started with the software. ETAP is a
complex software that needs a thorough understanding of the basics of power system
studies. Our ETAP training will help you learn the ETAP software from the scratch and
to get the most of this software for Power system studies.

Our Training Focus on Seven major topics from Power System Studies
Load Flow Analysis | Short Circuit analysis | Motor Acceleration study
Relay coordination | Arc Flash Studies | Harmonic analysis
Transient Stability

Batch Timing and Price

Monday to Thrusday - 10 AM to 4.30 PM IST One to One Training


Monday to Friday - 10 AM to 4.30 PM IST
Customed training as per
Friday - 10 AM to 4.30 PM IST
the requirement with
Saturday and Sunday - 10 AM to 4.30 PM IST
participants available time
Sunday - 10 AM to 4.30 PM IST

₹40,000 / $550 ₹80,000 / $1050


Free Pre Recorded Course Bundle
By joining the Course you will added to a WhatsApp group from there you will get
multiple paid course for free for life time and we will provide a Pre recorded Course
bundle worth 70,000 INR for free some of course topics as below

Let us better understand series Advanced Topics on


Variable Frequency Drive Load flow analysis
Transformers Unbalanced load flow analysis
Generators Short Circuit Analysis
Motors Motor Acceleration Study
Switchgears Relay Coordination Study
Arc Flash Study
Instrument Transformers
Harmonic Analysis
Circuit Breakers
Transient Stability Study
Inverters Grid islanding Study
Cables
Real Time Case Study
Earthing
Industrial case study using ETAP
Power System equipment modelling
2 MW Solar Power Plant
Other Software Recordings 50 MW Solar Power Plant
PVsyst for Solar plant Design 300 MW Solar Power Plant
Dialux Evo for Lighting Design Advanced Protection coordination

Click here to know more Click here to enroll in course

Weekly Free Webinars

Click the icons to follow us


Course content

Sl.No Topic Morning session Afternoon Session

1 Introduction about Power System Analysis Introduction about Load Flow Analysis with IEEE 3002-2 and IEEE 399

Modelling of Bus, Grid, Transmission line, Transmission line


surge impedance loading simulation with manual calculation, Two winding,
2 equivalent circuit, Ferranti effect Simulation with manual
three winding and 3-1 phase winding transformer modelling
calculation
Load Flow Analysis
Transformer paralleling, transformer losses, Transformer OLTC
3 Power factor correction and Reactive Power Compensation
Selection

Control modes of generator with simulation, capability curve, Modelling and simulation of ZIP Loads, VFD, Wind Turbine Generator, Solar
4
Contingency analysis Inverter

Short circuit analysis ,Types of fault, Symmetrical and


Fault far from source and Faults near to source, Symmetrical components,
5 Asymmetrical short circuit current, Standards, IEC 60909-
Motor and Generator's contribution to short circuit calculations
Assumptions,C factor

Short circuit currents for various faults, Manual calculation, impact Types of Earthing, SLG Current, Earthing Transformer, Specification
6
of Transformer Winding configuration, Significance of X/R ratio requirements for Cables, CB and VT in resistance grounded Systems
Short Circuit Analysis
Breaking, Making and DC Current, IEC 61363, Maximum and
7 Short circuit study for grid connected systems and islanded systems
Minimum Fault Current

8 Real time challenges and case studies Methods of Limiting Short Circuit Current

Motors, Need of Starters, Starting Torque Requirements, Static and NEMA design, Input requirements of Static and Dynamic MAS studies, Types
9
Dynamic Motor starting study of starters,
Motor Acceleration
Studies
Various Motor starting methods, Star - Delta, Soft Starter, VFD, Case studies, Selection of transformer impedance, Motor starting in islanded
10
LRS systems

Introduction to Protection in LV. Introduction to MCB, MCCB,


11 LV Protection Setting calculations, Modelling of Releases, Coordination
ACB, Thermal Magnetic Release, Electronic Release,

MV and HV, Need of Over current and Earth Fault Protection,


Protection Setting calculations of Over Current (50 & 51) and Earth Fault
12 Protection Setting calculations of Over Current (50 & 51) and Earth
Relays (50N, 51N) for motor feeder
Relay Coordination Fault (50N, 51N) for transformer feeder
Studies
Protection Setting calculations of Over Current (50 & 51) and Earth Sensitive Earth Fault Protection, Earth fault coordination is solid & Resistance
13
Fault Relays (50N, 51N) for Bus coupler, Incomer, Tie feeder Earthed System

14 Directional Overcurrent Protection Directional Earth fault Protection

IEEE 1584-2018 requirements, Personal Protective Equipment's, Incident


15 Introduction and need of Arc Flash Studies
Energy, Arcing Current, Arc Flash Boundary, Different Electrode Configuration
Arc Flash Studies
NFPA 70E, PPE Selection, Manual Calculation of Incident Energy
16 Case study, Methods to reduce incident energy, Label Creation
and Arcing Current, Voltage Variation

THD,TDD,IEEE 519-Voltage and current distortion limits, Impact of Capacitor


17 Introduction to Power Quality issues, Harmonic Analysis
Bank on THD, Modelling of Harmonic loads (WTG, VFD, Inverters, UPS)
Harmonic Analysis

18 Impact of Source impedance, Needs of Filters, Passive filter design Case studies, real time projects

Critical Clearing, Three Phase Bolted Faults, Relative Angle, Equal Area
19 Introduction to Transient Stability
Criteria, Swing Equation, Significance of Inertia
Transient Stability
Studies
SMIB System Example, Multi Machine modelling, Modelling of
20 Grid Islanding and Load Shedding, Loss of Load, Loss of Generation
AVR and Governor

Total Duration 100 hours

You might also like